Gaggenau VL414111 Datasheet

Color Variants VL414111
Stainless steel Width 11 cm
Installation Accessories VA420000
Connection strip for combination with other Vario appliances of the 400 series for flush installation
VA420001 Connection strip for combination with other Vario appliances of the 400 series for flush installation with appliance cover/adjustment strip
VA420010 Connection strip for combination with other Vario appliances of the 400 series for surface installation
VA420011 Connection strip for combination with other Vario appliances of the 400 series for surface installation with appliance cover/adjustment strip
Characteristics Product name/family Color chimney Typology Approval certificates
Australia Standards, CE, Eurasian, G­Mark, Ukraine, VDE
Length of electrical supply cord (cm) Required niche size for installation
(HxWxD)
170mm x 90mm x 492mm
Height of the chimney (mm) Height of product, without chimney
(mm) Minimum distance above an electric
hob Minimum distance above a gas hob Net weight (kg)
2.167
Type of control
Electronic
Number of speed settings Maximum output air extraction (m3/h)
540
Boost position output recirculating (m3/h)
Maximum output recirculating air (m3/ h)
470
Boost position air extraction (m³/h) Number of lights (Stck) Noise level (dB(A) re 1 pW)
68
Diameter of air outlet (mm)
150
Grease filter material
Washable stainless steel
EAN code
4242006258528
Consumption and connection features Connection rating (W) Current (A) Voltage (V) Frequency (Hz)
60; 50
Plug type Installation type
Built-in
created on 2019-08-05 Page 1
VL414111 Vario downdraft ventilation 400 series
Stainless steel Width 11 cm Air extraction/recirculation Without motor and control knob
Highly efficient ventilation system close to the cooktop Flexible power distribution, precise extraction of cooking vapours only at the open ventilation elements Can be combined perfectly with other Vario appliances of the 400 series Precision crafting of 3 mm stainless steel For surface installation with a visible edge or for flush installation Motorless, can be combined with Gaggenau BLDC remote fan units
Output
Power levels depend on the remote fan unit, see table on page XX.
Features
Manual opening of the ventilation element. Closing element made of stainless steel, dishwasher-safe. Metal grease filter, dishwasher-safe. Sensor-controlled operation of the extractor fan if at least one ventilation element VL 414 is open. No duct connection piece included.
Product rating
Energy efficiency class A. Energy consumption xxx. Ventilation efficiency class A. Grease filter efficiency class C. Sound level min. 56 dB / max. 68 dB normal mode.
Planning notes
Refer to the table on page XX for the matching remote fan units for air recirculation or air extraction mode. Appliance can be snapped into the worktop from above. Additional fixing by clamps accessible from above, clamping range 30-50 mm. If installing with the appliance cover VA 440 or adjustement strip VA 450 take into account the additional space required for the depth. If combining several appliances with at least one appliance cover, the adjustment strip VA 450 is required to compensate for the depth of the appliance without the appliance cover. If combining several Vario appliances of the 400 series, a connection strip VA 420 must be placed between the appliances. Depending on the type of installation, the corresponding connection strip must be provided. In the cut-out, the installation system requires the side edge to be at least 10 mm for surface installation and at least 13 mm for flush installation. Ensure a continuous cut surface of 90°. The bearing capacity and stability, in the case of thin worktops in particular, must be supported using suitable substructures. Take into account the appliance weight and additional loads. Additional instructions for flush installation: Installation is possible in worktops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the cut edges must be observed. Concerning other materials please consult the worktop manufacturer.
The groove must be continuous and even, so that uniform placing of the appliance on the gasket is ensured. Do not use discontinuous lining. The joint width may vary due to size tolerances of the combinations and of the worktop cut-out. If installing several appliances in individual cut-outs allow for a division bar of minimum 50 mm between the individual cut-outs. Maximum cooktop width between two VL: 60 cm. If operated next to gas appliances, the air baffle AA 414 010 is recommended to ensure maximum performance of the cooktop. If installed next to gas appliances, flat ducts must not be used for the piping up to the fan unit. If installed next to VP 414, the flat duct must not be positioned underneath the VP 414.
Connection
Connection cable 2.0 m between ventilation element VL 414 and control knob AA 490.
VL414111 Vario downdraft ventilation 400 series
Stainless steel Width 11 cm Air extraction/recirculation Without motor and control knob
created on 2019-08-05 Page 2
Loading...
+ 3 hidden pages