Characteristics
Product name/family
Color chimney
Typology
Approval certificates
Australia Standards, CE, Eurasian, GMark, Ukraine, VDE
Length of electrical supply cord (cm)
Required niche size for installation
(HxWxD)
170mm x 90mm x 492mm
Height of the chimney (mm)
Height of product, without chimney
(mm)
Minimum distance above an electric
hob
Minimum distance above a gas hob
Net weight (kg)
2.167
Type of control
Electronic
Number of speed settings
Maximum output air extraction (m3/h)
540
Boost position output recirculating
(m3/h)
Maximum output recirculating air (m3/
h)
470
Boost position air extraction (m³/h)
Number of lights (Stck)
Noise level (dB(A) re 1 pW)
68
Diameter of air outlet (mm)
150
Grease filter material
Washable stainless steel
EAN code
4242006258528
Consumption and connection features
Connection rating (W)
Current (A)
Voltage (V)
Frequency (Hz)
60; 50
Plug type
Installation type
Built-in
created on 2019-08-05
Page 1
VL414111
Vario downdraft ventilation 400 series
Stainless steel
Width 11 cm
Air extraction/recirculation
Without motor and control knob
Highly efficient ventilation system
close to the cooktop
Flexible power distribution, precise
extraction of cooking vapours only at
the open ventilation elements
Can be combined perfectly with other
Vario appliances of the 400 series
Precision crafting of 3 mm stainless
steel
For surface installation with a visible
edge or for flush installation
Motorless, can be combined with
Gaggenau BLDC remote fan units
Output
Power levels depend on the remote fan
unit, see table on page XX.
Features
Manual opening of the ventilation
element.
Closing element made of stainless
steel, dishwasher-safe.
Metal grease filter, dishwasher-safe.
Sensor-controlled operation of the
extractor fan if at least one ventilation
element VL 414 is open.
No duct connection piece included.
Product rating
Energy efficiency class A.
Energy consumption xxx.
Ventilation efficiency class A.
Grease filter efficiency class C.
Sound level min. 56 dB / max. 68 dB
normal mode.
Planning notes
Refer to the table on page XX for
the matching remote fan units for air
recirculation or air extraction mode.
Appliance can be snapped into the
worktop from above. Additional fixing
by clamps accessible from above,
clamping range 30-50 mm.
If installing with the appliance cover
VA 440 or adjustement strip VA 450
take into account the additional space
required for the depth.
If combining several appliances with
at least one appliance cover, the
adjustment strip VA 450 is required
to compensate for the depth of the
appliance without the appliance cover.
If combining several Vario appliances
of the 400 series, a connection strip
VA 420 must be placed between the
appliances. Depending on the type
of installation, the corresponding
connection strip must be provided.
In the cut-out, the installation system
requires the side edge to be at least 10
mm for surface installation and at least
13 mm for flush installation. Ensure a
continuous cut surface of 90°.
The bearing capacity and stability, in
the case of thin worktops in particular,
must be supported using suitable
substructures. Take into account the
appliance weight and additional loads.
Additional instructions for flush
installation:
Installation is possible in worktops
made of stone, synthetics or solid
wood. Heat resistance and watertight
sealing of the cut edges must
be observed. Concerning other
materials please consult the worktop
manufacturer.
The groove must be continuous and
even, so that uniform placing of the
appliance on the gasket is ensured. Do
not use discontinuous lining.
The joint width may vary due to size
tolerances of the combinations and of
the worktop cut-out.
If installing several appliances in
individual cut-outs allow for a division
bar of minimum 50 mm between the
individual cut-outs.
Maximum cooktop width between two
VL: 60 cm.
If operated next to gas appliances, the
air baffle AA 414 010 is recommended
to ensure maximum performance of the
cooktop.
If installed next to gas appliances, flat
ducts must not be used for the piping
up to the fan unit.
If installed next to VP 414, the flat duct
must not be positioned underneath the
VP 414.
Connection
Connection cable 2.0 m between
ventilation element VL 414 and control
knob AA 490.
VL414111
Vario downdraft ventilation 400 series
Stainless steel
Width 11 cm
Air extraction/recirculation
Without motor and control knob