Important information
This appliance conforms to the relevant safety regulations.
Repairs should only be carried out by qualified specialists.
Improperly executed repairs can give rise to significant hazards for the user.
Note down the type designation of the
external fan in the extractor hood operating instructions.
The appliance should only be
connected up to the mains and taken into use by a qualified specialist.
Before carrying out repairs or
maintenance, isolate the fan. To do this, disconnect the plug-and-socket connection of the electric cable which is connected to the extractor hood or disconnect the extractor hood power cord from the power supply.
If the connecting cable for this
appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user.
Old appliances are not worthless
rubbish. If they are disposed of in an environment-friendly manner, valuable raw materials can be recovered for use again. Before you dispose of an old appliance, make sure that it has been rendered inoperative.
This appliance conforms to the relevant safety regulations.
Repairs should only be carried out by qualified specialists.
Improperly executed repairs can give rise to significant hazards for the user.
Your new appliance was protected on
its way to you by the packaging. None of the materials cause pollution to the environ­ment and all can be recycled for use again. Please help to protect the environment and dispose of the packaging in an environment-friendly manner.
You can obtain information about the best method disposing of old appliances and packaging from your dealer or local municipal council.
3
Prior to installation
Observe the official and statutory regulations for the removal of exhaust air (e.g. Landesbauordnungen).
D
If the extractor hood is operating in
exhaust-air mode at the same time as a flue-type heater (e.g. gas, oil or solid-fuel
heater, instantaneous water heater, boiler),
there must be an adequate air supply
which the fireplace requires for combusti­on.
Safe operation is possible if the partial vacuum in the installation room of the fire­place does not exceed 4 Pa (0.04 mbar).
This can be achieved if the combustion air is able to flow through non-lockable ope­nings, e.g. in doors, windows and in con­junction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlocking.
If the air supply is inadequate, there is a risk of poisoning caused by combustion gases being drawn back into the room.
Note: When assessing the air supply, always take into account the entire ventila­tion system in the house. This rule does not apply when using cooking appliances, e.g. hob or gas cooker.
Do not attach the outer wall fan near
windows, doors or patios.
When attaching the outer wall fan,
ensure that – residents and neighbours are not
disturbed by noise and odours,
– it is accessible for maintenance and
repairs.
The plug-and-socket connections of
the electric cables must be located inside the building.
Preparing the wall
RISK OF INJURY,
DAMAGE TO PROPERTY
Before drilling the holes for the designated installation location, check for concealed electrical cables and other lines.
K The wall must be level and vertical. K The enclosed screws and wall plugs are
suitable for solid brickwork. Use the appropriate fixing materials for other wall structures (e.g. plaster board, porous concrete, poroton bricks). Ensure that the wall has adequate load bearing capacity.
K Ensure that the depth of the drilled holes
corresponds with the length of the scr­ews.
K Ensure that the wall plugs are secure.
Weight: 7,0 kg.
We reserve the right to construction changes within the context of technical development.
4
Installation
1. Wall opening
Diameter at least 8
17
/64”.
Distance to floor at least 39
1
/2” to ensure
an unobstructed air outlet.
2. Drill 4x
5
/16” ø holes for the mounting plate and press in wall plugs flush with the wall.
3. Drill
15
/32” ø hole for the electric cable.
The fan is connected to the extractor
hood with the Z 197” extension cable enclosed with the extractor hood. Ensure that the cables are fed through properly.
4. Seal mounting plate and screw on tight.
Risk of electric shock
The mounting plate must be sealed to the outer wall with a suitable material to prevent water from entering the
appliance.
Please follow application instructions and observe use-by date for the enclo­sed silicone.
4x
A
B
5. Screw the fan onto the mounting plate.
(210mm)
Ø (8mm)
1
/2
949/64
(248mm)
15
Ø (12mm)
17
Ø8
/
64
5
/16
4x
/32
31
7
/64
(190mm)
33
2
/64
(64mm)
13/16
(30mm)
47
3
/64
(95mm)
min 39
(1.000mm)
4x
5
User information
Safety instructions
Regularly check that air can flow freely
out of the fan. Do not obstruct the air outlet grille or cover with plants.
If the connecting cable for this
appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified per­son in order to prevent serious injury to the user.
Cleaning and care
K Use a mild non-abrasive stainless steel
cleaner.
Do not use any of the following to clean
stainless steel surfaces: abrasive sponges, cleaning agents containing sand, soda, acid or chloride!
K Apply a little stainless steel cleaner from
time to time in order to maintain the appearance of the appliance.
6. Connect the pipe and cable from the fan to the extractor hood.
The additional cover on the plug
must always be attached and closed for safety reasons.