Gaggenau AR400740 PRODUCT SPECIFICATIONS

Inline blower
4x ∅ 6" (∅ 150)
AR 400
– AR 400 740 for maximum output
for downdraft ventilation and blowerless hoods
– Installation in a separate room
reduces noise level in the kitchen
– To be combined with blowerless
hoods or downdrafts
2 connecting pieces included Additional connection piece must be ordered serarately. Part #653556
AR 400 740
Metal housing 810 CFM Inside installation
Air extraction
Installation accessories
AA 009 910
Ceiling installation set
Additional ø 6" connection piece Required when installing up to 3 or 4 VL 414 downdraft with AR 400 inline blower.
Output
810 CFM unobstructed air flow. Noise level depends on the built-in
situation.
Features
Metal housing, zinc-plated. Duct connections air intake: (1) ø 8" round, (4) ø 6"round.
Duct connection pressure side:
(1) ø 8" round. Spare cover for closing air intake.
Planning notes
Inline blower for use with
Vario 400/
200, VL downdraft, AL 400 retractable downdraft or AI/ AW 402 720 island/wall hood. Up to 4 Vario 400 VL 414 downdraft units can be used with AR 400 inline blower with one AA 490 control knob. Installations using extraction with a chimney-vented furnace require a circuit breaker for the hoods power supply line. Installation in the drawer area with double height or on the floor with cut-out in the cabinet base. Air intake with duct max. (2) ø 6" behind the drawers requires countertop depth of min. 27". Cabinets without toe-kick possible. If second AR 400 blower is added in combination with Vario 400/200 series VL downdraft or AL 400 retractable downdraft, circuit amplifier AA 090 700 is required.
AA 009 910 ceiling installation set
Rating
Total rating: 520 W. Total Amps: 6. 120V / 60 Hz Plan for a 41⁵⁄₁₆" connecting cable without plug.
Numbers indicated inside parenthesis ( ) = mm
Ventilation 141