Furuno IC-307, FELCOM 15, FELCOM 16, FELCOM 18, FELCOM 19 Operator's Manual

OPERATOR'S MANUAL
SHIP SECURITY
ALERT SYSTEM (SSAS)
USCG Version
Model
IC-307
(For FELCOM 15/16/18/19)
www.furuno.com

TABLE OF CONTENTS

SYSTEM CONFIGURATION ..................................................................................... ii
1. OVERVIEW OF SSAS .......................................................................................... 1
2. INSTALLATION .................................................................................................... 3
2.1 Mounting ........................................................................................................................... 3
2.1.1 Junction box (for FELCOM 16/19) ........................................................................... 3
2.1.2 SSAS alert unit ......................................................................................................... 4
2.2 Wiring ................................................................................................................................ 6
2.2.1 Junction box (for FELCOM 16/19) ........................................................................... 6
2.2.2 SSAS alert unit ......................................................................................................... 7
2.3 Enabling USCG Version ................................................................................................... 8
3. OPERATION ......................................................................................................... 9
3.1 Operation Mode ................................................................................................................ 9
3.1.1 Changing the password............................................................................................ 9
3.1.2 SSAS manager mode ............................................................................................ 10
3.2 Setting SSAS Report Destination and Message Contents .............................................. 11
3.3 Transmitting SSAS Report .............................................................................................. 15
3.4 Testing the Button ........................................................................................................... 16
3.5 SSAS Report Test ........................................................................................................... 20
4. WATERPROOFING KIT ...................................................................................... 21
OUTLINE DRAWINGS ........................................................................................... D-1
INTERCONNECTION DIAGRAMS ......................................................................... S-1
i

SYSTEM CONFIGURATION

Regulations require at least two SSAS alert units.
FELCOM 15
ANTENNA
UNIT
IC-115
DGPS
100-115/200-230 VA C 1, 50/60 Hz
24 VDC
12-24 VDC
24 VDC
SSAS Alert Unit
IC-307
SSAS Alert Unit
IC-307
FELCOM 16
AC-DC Power Supply
PR-240-CE*1
Printer PP-510
Mini Keyboard
SSAS Alert Unit
IC-307
(Max. 3 units)
TERMINAL UNIT
IC-215
GPS receiver
OP16-24
JUNCTION
BOX
IC-315
*1 Any AC-DC power supply fulfilling requirements of IEC 60945 may be used.
ANTENNA
UNIT
IC-116
EGC Printer
PP-505
Personal
Computer
(PC/AT compatible)
Shipboard LAN (Ethernet)
Distress Alert/
Received Call Unit
IC-305
Alarm Unit
IC-306
Navigator
: Standard Supply : Option : Local Supply
24 VDC
Printer
100-115/200-230 VA C 1, 50/60 Hz
24 VDC
12-24 VDC
SSAS Alert Unit
IC-307
SSAS Alert Unit
AC-DC
Power Supply
PR-240-CE*1
IC-307
INMARSAT MINI-C MOBILE EARTH STATION
FURUNO
POWER
I
O
SSAS Alert Unit
IC-307
COMMUNICATION UNIT IC-216
(with internal GPS receiver)
LOGIN
POWER
TX
ERROR
PERSONAL
COMPUTER
(PC/AT compatible)
JUNCTION BOX
IC-315
PRINTER
: Standard : Option : Local Supply
(Max. 3 units)
ii
FELCOM 18
12/24 VDC
For 12 VDC power, DC-DC converter is required to use PP-510.
SSAS Alert Unit
IC-307
SSAS Alert Unit
IC-307
AC-DC Power Supply
PR-240
Printer PP-510**
Mini keyboard 5139U
SSAS Alert Unit
IC-307
Max. 3 units
TERMINAL
UNIT
IC-218
GPS Board
OP16-62
(built-in)
JUNCTION BOX
IC-318
ANTENNA
UNIT
IC-118
DGPS
PC
Shipboard LAN (Ethernet)
Navigator
Distress Alert/
Received Call Unit
IC-305/IC-350
Alarm Unit
IC-306
FELCOM 19
SHIP'S MAINS 12-24 VDC
AC-DC
Power Supply
PR-240
COMMUNICATION UNIT IC-219
(with internal GPS receiver)
ANTENNA
JUNCTION BOX
IC-318
SSAS ALERT UNIT
IC-307*
SSAS ALERT UNIT
IC-307*
UNIT
IC-119
PERSONAL
COMPUTER
(Windows OS)
* At least two SSAS Alert Units are required.
NAVIGATOR
(GLONASS
compliant)
iii

1. OVERVIEW OF SSAS

The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES FELCOM 15/18 or the Inmarsat Mini-C FELCOM 16/19 for the purpose of alerting specified addresses (for example, your ship’s company) that your ship is under attack by intruders. The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed before 01 July 2004 to install an SSAS.
When your ship is under attack an SSAS report, which contains your ship’s name, MMSI No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized personnel. No audible or visible alarm is generated while the SSAS report is being transmitted, to prevent discovery of the report by the intruders.
The SSAS is protected with a password to prevent unauthorized setting or testing of it by other than the ship’s captain or authorized personnel.
Inmarsat System
Ship Name, MMSI No., Ship Position, etc.
USCG station
1
SSAS operation flow
1. Open the cover and press button one second.
SSAS report is immediately transmitted.
2. An LES sends acknowledgement to your ship.
3. SSAS report is automatically sent to multiple addresses if applicable.
4.Repeated transmission of the SSAS report begins. The interval at
which to transmit the SSAS report to each address can be specifed. The SSAS report is continuously transmitted at the interval selected.
5. To cancel repeated transmission:
Terminal unit: Turn off the communication unit. Press and hold down the button on the SSAS unit while turning on the communication unit. Release the button when the test mode starts. (The FELCOM 16 goes into the button test mode.) Note that if there are any unsent messages they are sent and then the system goes into normal operation; namely, the test mode is not activated.
PC: Open the SSAS manager (see page 10) and input the command TERMINATE SSAS ALERT.
2

2. INSTALLATION

2.1 Mounting

2.1.1 Junction box (for FELCOM 16/19)

The junction box IC-315 is required when installing the SSAS on the FELCOM 16/19; it is already installed on the FELCOM 15/18.
Separate the junction box from a magnetic compass by the distances shown below to prevent deviation to a magnetic compass.
IC-315 Standard compass: 1.0 m Standard compass: 0.90 m Steering compass: 0.70 m Steering compass: 0.90 m
1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.
IC-318
120 0.5
0.5
70
Junction box IC-315/318
The junction box is connected to the communication cnit with a 2 meter cable, with D-sub connector (at the communication unit). Therefore, locate the junction box within two meters of the communication unit.
3

2.1.2 SSAS alert unit

Separate the junction box from the SSAS alert unit by the distances shown below to prevent deviation to a magnetic compass.
Standard compass: 0.70 m Steering compass: 0.45 m
Locate the SSAS alert unit where it cannot be found by intruders. The location should be known only by ship’s captain and authorized personnel.
Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (supplied).
3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance, change the clamp orientation as follows:
a) Unfasten three screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.
Unfasten three screws.
Clamp
Rotate
Fasten three screws.
4. Run the cable thru one of the cable entrances and connect it to terminal board.
4
5. Attach the switch cover as shown below. Note that the cover may also be rotated 180 degrees.
Switch cover
Flush mounting
The optional flush mount kit OP16-28 (Code No. 004-448-010) is required.
Fixture 16-018-7201-1 100-317-931 1 Pan head screw M3x6 000-800-362 4 Self-tapping screw 4x16 000-802-080 4
Name Type Code No. Qty Remarks
1. Cut out the mounting position referring to the outline drawings at the back of this manual.
2. Fix the unit to the fixture with four pan head screws (supplied).
3. Fasten the fixture with the unit to the mounting location with four self-tapping screws (supplied).
4. Attach switch cover as shown above.
5

2.2 Wiring

2.2.1 Junction box (for FELCOM 16/19)

Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16, or the junction box IC-318 to connect the SSAS alert unit to the FELCOM 19. Unfasten four screws to remove the cover to connect cables to terminal board. For detailed wiring information see the interconnection diagram.
For connecting the SSAS alert unit IC-307, use the JIS cable TTYCS-4 (or equivalent, see next page for sectional view of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp 16-018-6008-1, supplied with the junction box. For connecting the communication unit IC-216, use cable 16S0344.
IC-315 IC-318
Communication Unit
Cable clamp
Terminal board
16S0344
Vcc
1
GND
2
TD/RD-A
3
TD/RD-B
4
NC
Cover
Cable clamp (top)
5
TD-A(NAV)
6
TD-B(NAV)
7
RD-A(NAV)
8
RD-B(NAV)
9
GND
10
DMC OUT-H
11
DMC OUT-C
12
DMC IN-H
13
DMC IN-C
14
DMC CTR
15
Cable clamp (bottom)
Fold back braided shield onto sheath and fix by cable clamp.
Vcc
1
GND
2
TD/RD-A
3
IC-305/306
TD/RD-B
4
NC
5
ALM-H
6
ALM-C
7
RD-A(NAV)
8
RD-B(NAV)
9
GND
10
SSAS OUT-H
11
SSAS OUT-C
12
SSAS IN-H
13
SSAS IN-C
14
SSAS CTR
15
IC-305/306
1
2
3
Core 7 mm
Procedure
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
90mm15mm 7mm
Connect the drain wire of the TTYCSLA cables with the screw and crimp-on lugs provided.
Screw, crimp-on lug (pre-fitted at factory)
3. Insert cable core to 3 .
Note 1: Do not insert the cable too deeply, to prevent pinching the sheath.
Note 2: Pull each cable slightly to con- firm that they are in their holes securely.
IC-318 (inside)
6

2.2.2 SSAS alert unit

Three SSAS alert units can be connected. For wiring, see the illustrations below and the interconnection diagram at the back of this manual. For the terminal unit (FELCOM 15/18) and the communication unit (FELCOM 16/19), the wiring of the SSAS is monitored and if in error “TROUBLE: SSAS UNIT connection abnormality.” is displayed. Further the ERROR lamp (FELCOM 16) flashes.
Junction
Box
IC-307
(No.1)
IC-307 (No. 2)
IC-307 (No. 3)
Connect wiring to the terminal board 16P0229 inside the SSAS alert unit. To differentiate between units in case of multiple unit installation, change jumper block settings as shown below, in accordance with how many units are installed.
Jumper settings for two IC-307
Unit
Jumper
JP1 JP2
No. 1 unit: Unit with two cables connnected to it. No. 2 unit: Unit with one cable connnected to it.
Two IC-307: No. 2 unit
Three IC-307: No. 3 unit
16P0229
JP1
12345
No.1 unit* No. 2 unit
No Yes
JP2
Yes No
Three IC-307: No. 1 and No. 2 units
6
*: Default setting
Two IC-307: No. 1 unit
16P0229
Jumper settings for three IC-307
Unit
Jumper
JP1 JP2
No. 1 and No. 2 units: Units with two cables connnected to them. No. 3 unit: Unit with one cable connnected to it.
JP2
JP1
12345
No.1 unit*
No Yes
6
No. 2 unit*
No Yes
No. 3 unit
Yes No
Clamp for cable CO-SPEVV-SB-C
0.2x5P
Clamp for cable TTYCS-4 or equivalent
IC-307
IC-307
Cable Fabrication
Twist shield.
CO-SPEVV-SB-C 0.2X5P or TTYCS-4
Cut and tape unused wires to prevent short.
= 16.3
mm
Conductor
Sectional view of cable TTYCS-4
Wiring inside the SSAS alert unit
7
15 mm 40 mm 10 mm
Armor
Sheath
Shield
S = 0.75 mm = 1.11 mm
2

2.3 Enabling USCG Version

1. FELCOM 15: Press [F8], [2] to show the System Setup menu. FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu.
2. Press [] to choose Command Window and then press the [Enter] key.
Command Window
RFCONCPU *** [ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup Enter JOB No. :
[Main menu]
1. Remote Box Setup
2. External Alarm Setup
3. AMS Setup
4. Management Profile Setup Enter JOB No.:
Command Window
FELCOM 15/16
FELCOM 18/19
3. Type “furunoservice” (without quotation marks) in the Enter JOB No. field and then press
the [Enter] key. The prompt PASSWORD appears.
4. Enter password (see FURUNO Information for SSAS) then press the [Enter] key. Then,
the item Main Menu is displayed in reverse video.
5. Press [1], [Enter], [1], [Enter]. One of the following windows appears.
[ DMC ]
1. SSAS(IC-307)
2. DMC
3. OFF 4: SSAS(Momentary SW) E: Exit Enter No.:
[ SSAS ]
1. ON(IC-307)
2. OFF 3: Momentary SW (for USCG) E: Exit Enter No.:
FELCOM 16FELCOM 15
[ SSAS ]
1. OFF
2. IC-307 (Standard SSAS) 3: IC-307 (Russia SSAS) 4: SSAS (Momentary SW) E: Exit Enter No.:
[ SSAS]
1. OFF
2. IC-307(Standard) 3: IC-307(Russian) 4: Momentary SW (for USCG) E: Exit Enter No.:
FELCOM 18 FELCOM 19
6. Press [4] (FELCOM 15/18/19) or [3] (FELCOM 16) to enable the USCG version.
7. Press the [Esc] key several times to close the menu.
8

3. OPERATION

3.1 Operation Mode

There are two menu operating modes:
Normal mode: Menus other than SSAS-related menus are displayed. SSAS manager mode: The mode is activated by the password entered by the ship’s
captain or authorized personnel. The indication “SSAS Manager Mode” is shown at the top of the screen when this mode is activated, and it is flashing. All SSAS-related menus are available. Transmission of the SSAS report may be cancelled in this mode. The equipment starts up in the normal mode, regardless of the mode in use when the power is turned off.

3.1.1 Changing the password

The default password is “ship security alert”. Ship’s captain or authorized personnel may change the password as follows:
1. FELCOM 15: Press [F8], [2] to show the System Setup menu. FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu.
2. Press [] to choose Command Window and then press the [Enter] key.
Command Window
RFCONCPU *** [ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup Enter JOB No. :
FELCOM 15/16
[Main menu]
1. Remote Box Setup
2. External Alarm Setup
3. AMS Setup
4. Management Profile Setup Enter JOB No.:
Command Window
FELCOM 18/19
3. On the Enter JOB No. field, type “ssas password” (without quotation marks) and then press the [Enter] key. The prompt OLD PASSWORD appears.
4. Type your current password and then press the [Enter] key. The prompt NEW PASSWORD appears.
5. Enter new password, using at least six characters, and then press the [Enter] key. The prompt RETYPE NEW PASSWORD appears.
Note: If less than six characters are entered, the message “Please use a longer
password.” appears. Enter a longer password.
6. Enter new password again and then press the [Enter] key. The message “Password changed” appears.
7. Press the [Esc] key several times to close the menu.
Note: The SSAS manager mode cannot be accessed without the correct password.
9

3.1.2 SSAS manager mode

All SSAS-related settings are set in the SSAS manager mode. Do the following to access this mode.
1. FELCOM 15: Press [F8], [2] to show the System Setup menu. FELCOM 16/18.19: Press [F8], [1] to show the System Setup menu.
2. Press [] to choose Command Window and then press the [Enter] key.
Command Window
RFCONCPU *** [ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup Enter JOB No. :
FELCOM 15/16
[Main menu]
1. Remote Box Setup
2. External Alarm Setup
3. AMS Setup
4. Management Profile Setup Enter JOB No.:
Command Window
FELCOM 18/19
3. On the Enter JOB No. field, type “ssas manager” (without the quotation marks) and then
press the [Enter] key.
Note: If there is no SSAS equipment connected, the message "Command Ignored: No SSAS button is installed." appears.
4. Type password and then press the [Enter] key to go into the “SSAS Manager Mode”.
The indication “SSAS Manager Mode” is shown at the top of the screen when this mode is activated, and it is flashing.
CAUTION 04-04-20 05:37 (UTC) SSAS Manager Mode enabled.
<Press ESC key to continue>
5. Press the [Esc] key several times to close the menu. This enables the SSAS manager mode, which allows you to execute the procedure in paragraph 3.2.
Note: Turn the power off and on again whenever changing SSAS-related settings.
10

3.2 Setting SSAS Report Destination and Message Contents

When the SSAS is activated, the SSAS report is sent according to the addresses (max. 5 for FELCOM 15/16, 10 for FELCOM 18/19) and message content set with SSAS Report 1 – SSAS Report 5 for FELCOM15/16 or SSAS Report 10 for FELCOM 18/19 on the SSAS Report menu.
Note 1: The destination and message content of an SSAS report vary according to
Administration. Therefore, set them as requested by ship’s authorities. For information other than ship’s name, MMSI no. and IMN no., set it manually with “Other Inf.”
Note 2: The equipment must be in the SSAS manager mode to execute this procedure.
See paragraph 3.1.2.
1. Press the [F5] to open the Reports menu.
Reports
1. Data Report
2. Message Report
3. Data Network ID
4. SSAS Report
1. Data Report
2. Message Report
3. Enhanced Pre-Assigned Data Report (EPADR)
4. Data Network ID
5. SSAS Report
Reports
FELCOM 15/16
FELCOM 18/19
2. Press the [4] key to show the SSAS Report menu.
SSAS Report
1. SSAS Report 1
2. SSAS Report 2
3. SSAS Report 3
4. SSAS Report 4
5. SSAS Report 5
6. Message Contents
FELCOM 15/16
SSAS Report
1. SSAS Report Destination
2. Message Contents
FELCOM 18/19
3. For FELCOM 18/19, press the [1] key to show the SSAS Report Destination menu.
For FELCOM 15/16, select the appropriate report number to show the SSAS Report Destination menu.
SSAS Report Desitnation
Enter: Report Entry ESC: Quit
Mode
No
01
Test Only
02
03
Real+Test 04
05 06
07
08
09 10
Selected mode (Real+Test,
Real Only, Test Only) is
Destination
test@test
123456789
Destination ID or mail address
displayed here
Interval
00:10
02:00
Interval is displayed in the hh:mm format. Setting range: 00:10 to 99:59
11
4. Press the [] or [] key to choose the report number desired and then press the [Enter] key to display the window shown on the following page.
Status Mode Station Name
Destination Type Prefix Code Country/Ocean Code Station ID Modem Type Address Subject
LES ID
Report Interval
SSAS Report
ON Real+Test
TELEX
02:00 (hh: mm)
Status Mode Station Name
Destination Type Prefix Code Country/Ocean Code Destination Modem Type Address Subject
LES ID
Report Interval
SSAS Report ON
Real+Test
TELEX/MES
02:00
FELCOM 15/16 FELCOM 18/19
5. Press the [↓] key to choose Mode and then press the [Enter] key.
Real+Test
Real Only Test Only
6. Press the [] or [] key to choose mode desired and then press the [Enter] key.
“Mode” defines what SSAS report(s) a station is to receive:
Real+Test: Actual SSAS report and test SSAS report. Real Only: Actual SSAS report only. Test Only: Test SSAS report only.
7. Press the [↓] key to choose Station Name and then press the [Enter] key.
8. Press the [] or [] key to choose appropriate station and then press the [Enter] key. You may sort the list by group name, station name or communication type as follows:
Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending or descending order. Station name: Each press of [Ctrl] + [N] sorts the list by station name, in ascending or descending order. Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in ascending or descending order.
9. Press the [] key to choose LES ID and then press the [Enter] key.
10. Press the [] or [↓] key to choose LES and then press the [Enter] key.
Note: Change the LES whenever sea area has changed. However, the equipment automatically searches for an LES with which you can communicate and the SSAS report is transmitted to that LES.
11. Press the [] key to choose Report Interval and then press the [Enter] key.
12. Enter time interval (00:10-99:59) to transmit the SSAS report and then press the [Enter] key.
13. Press the [Esc] key to open the Update window.
Update
Yes
No
14. Yes is selected; press the [Enter] key to close the SSAS report window.
12
15. Press the [2] key to display the SSAS Message Contents menu.
SSAS Message Contents
Vessel Name :
MMSI : IMN : Other Inf. :
LAT: LON: Time: COURSE: SPEED: Time:
Vessel Name :
Call Sign : MMSI IMN IMO : Other Inf. :
LAT: LON: Time: COURSE: SPEED: Time:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 34: 44. 46N 135: 21. 26E 02/04/2012 04:31:48 (UTC) 071 deg 00 kt 02/04/2012 04:31:48 (UTC)
FELCOM 15/16
SSAS Message Contents
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
:
_ _ _ _ _ _ _ _ _
:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 34: 44. 46N 135: 21. 26E 02/04/2012 04:31:48 (UTC) 071 deg 00 kt 02/04/2012 04:31:48 (UTC)
FELCOM 18/19
16. Press the [Enter] key to open the Vessel Name window.
17. Enter vessel’s name and then press the [Enter] key.
18. Press the [] key to choose MMSI and then press the [Enter] key.
19. Enter MMSI number and then press the [Enter] key.
20. Press the [] key to choose IMN and then press the [Enter] key.
21. Enter IMN and then press the [Enter] key.
22. Press the [] key to choose Other Inf. and then press the [Enter] key
23. Enter appropriate message (for FELCOM15/16: three lines, for FELCOM18/19: six lines) and then press the [Enter] key.
Note: To shift between lines, use the [] or [↓] key.
24. Press the [Esc] key to open the Update window.
25. Yes is selected; press the [Enter] key to close the SSAS Message Contents menu.
26. Press the [Esc] key twice to return to the standby display.
Note 1: To delete entered subscriber’s data, choose “Remove” from “Status.” Note 2: SSAS report settings may be saved to a floppy disk for backup.
FELCOM 15: [F8], [9], [6] to show the Save/Load window. FELCOM 16: [F8], [8], [6] to show the Save/Load window. FELCOM 18/19: [F8], [8], [6] to show the Export/Import window.
13
Save to FD
1. ALL
2. Station List
3. LES List
4. E-Mail Service List
5. SSAS Report*
6. Other
Load from FD
1. ALL
2. Station List
3. LES List
4. E-Mail Service List
5. SSAS Report*
6. Other
*: Availlable only in SSAS manager mode
("5.SSAS Report" is added in the SSAS manager mode and item numbers are shifted.)
FELCOM15/16
Export
1. Sent Message
2. Received Message
3. EGC Message
4. Station List
5. LES List
6. E-Mail/SMS Service List
7. Test
8. Maintenance
9. Settings
1. Station List
2. LES List
3. E-Mail/SMS Service List
4. Settings
Import
FELCOM 18/19
Note 3: To confirm the settings, follow paragraph 3.5.
14

3.3 Transmitting SSAS Report

The SSAS report is sent one second after the button on the SSAS is pressed. Repeated transmission can only be stopped from the SSAS manager mode.
1. Open the cover of the SSAS alert button.
Cover
2. Push the button one second. The button is a momentary switch, meaning it is activated
as soon as it is pressed one second.
3. The SSAS report is transmitted after the button is pushed one second. Below are the
contents of the SSAS report.
- - -
SSAS ALERT MESSAGE Vessel Name: Queen Elizabeth 2 MMSI: 111660000 IMN: 443100000 Help me! LAT: 34:44.46N LON: 135:21.26E Time: 02/04/2004 04:31:48 (UTC) COURSE: 071 deg SPEED: 00 kt Time: 02/04/2004 04:31:48 (UTC)
- - -
FELCOM 15/16
- - - SSAS ALERT MESSAGE - - ­Vessel Name: Queen Elizabeth 2 MMSI: 111660000 IMN: 443100000 IMO: 123456789 Help me! LAT: 34:44.46N LON: 135:21.26E Time: 02/04/2004 04:31:48 (UTC) COURSE: 071 deg SPEED: 00 kt Time: 02/04/2004 04:31:48 (UTC)
Ship's Name MMSI No. IMN No. Desired message Own ship postion in latitude Own ship position in longitude Time of position data Course Speed Time of course and speed data
Ship's Name MMSI No. IMN No. IMO No. Desired message Own ship postion in latitude Own ship position in longitude Time of position data Course Speed Time of course and speed data
FELCOM 18/19
15
Note: If you accidentally push the button in, push it again within 30 seconds to cancel the report.
The button pops out ( SSAS UNIT activation has been canceled.” appears on the display. Additionally, for the FELCOM 16/19, the POWER lamp on the communication unit flashes 30 seconds.
) and the report is not transmitted. When this is done, the message “INF:
4. An LES sends acknowledgement to your ship.
5. For multiple destinations, steps 3 and 4 are automatically repeated (it is not necessary to push the button again).
Cancelling repeated transmission
Terminal Unit: Turn off the communication unit. Press and hold down the button on the
SSAS unit while turning on the communication unit. Release the button when the test mode starts. (The FELCOM 16/18/19 goes into the button test mode.) Note that if there are any unsent messages they are sent and then the system goes into normal operation; namely, the test mode is not activated.
PC: Open the SSAS manager (see page 12) and input the command TERMINATE SSAS ALERT.

3.4 Testing the Button

The SSAS buttons can be tested as below.
Note 1: An actual SSAS report cannot be transmitted during the testing. Note 2: The equipment must be in the SSAS manager mode to conduct the test.
FELCOM 15/18
1. Press the [F7] key to display the Options menu.
2. Press one of the following keys to display the Test menu:
Operating mode is Inmarsat-C: [7] key FELCOM 18: [8] key Operating mode is EGC receiver: [6] key
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. Distress/SSAS Button Test
Test
3. Press the [4] key.
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
6. Test
Test
Distress/SSAS Button Test
Yes
Start
No
4. Press the [Enter] key to start the test.
16
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
Distress/SSAS buttons are under test mode.
3. Self Test
5. Ocean Region
INF: SSAS Buttons entered into TEST MODE.
4. Distress Alarm Button Test
6. Test
Test
Distress/SSAS Button Test
Press any key to escape.
CAUTION
<Press ESC key to continue>
The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel the test mode if a real distress/SSAS needs to sent.” appears.
5. Open the button cover on the No.1 SSAS.
6. Push the button. The CAUTION window displays the message “SSAS UNIT works correctly.” appears if the unit is functioning properly.
7. Five seconds after pressing the button the SSAS test report is automatically sent to
station whose Mode set on the SSAS Report window is “Real+Test” or “Test Only”.
Note: To test the No. 2 and No. 3 SSAS press appropriate button.
8. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has been restored.
CAUTION
INF: Distress/SSAS Buttons returned to NORMAL OPERATION.
<Press ESC key to continue>
9. Press the [Esc] key three times to return to the standby display.
17
FELCOM 16/19, no PC
Turn off communication unit.
Turn on button of No. 1 SSAS.
Turn on communication unit.
30 s
POWER, LOGIN and TX lamps flash in that order.
Send SSAS test report?
Yes (after 30 s)
SSAS report is sent to station(s) whose mode is "Real+Test" or "Test Only". (See paragraph 3.2.) Lamps flash rapidly during TX. It takes 2 to 5 minutes to send one message.
No
Test
successful?
Yes
POWER, LOGIN and TX lamps flash in that order. ERROR lamp also flashes.
Turn off button of No. 1 SSAS.
The POWER, LOGIN and TX lamps flash in that order.
ERROR lamp flashes rapidly.
No (within 30 s)
T est TX
Turn on button of No.2 SSAS.
T est TX
Turn off button of No.2 SSAS.
Turn communication unit off and on again.
Note: If a 3rd SSAS unit is installed
test it by procedure used to test No.2 unit.
18
FELCOM 16/19, PC version
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display
the Test menu. For FELCOM 19, press the [8] key.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. SSAS Button Test
3. Press the [4] key.
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
6. Test
Test
SSAS Button Test
Yes
Start
No
4. Press the [Enter] key to start the test.
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
Distress/SSAS buttons are under test mode.
3. Self Test
5. Ocean Region
INF: Distress/SSAS Buttons entered into TEST MODE.
4. Distress Alarm Button Test
6. Test
Test
Distress/SSAS Button Test
Press any key to escape.
CAUTION
<Press ESC key to continue>
The display shows the message (in red) “SSAS buttons are under test. Cancel the test mode if a real SSAS alert needs to sent.” appears.
5. Open the button cover on the No. 1 SSAS.
6. Push the button. The CAUTION window displays the message “SSAS UNIT works
correctly.” appears if the unit is functioning properly.
7. Five seconds after the button is pushed the SSAS test report is automatically sent to the
station(s) whose Mode set on the SSAS Report window is “Real+Test” or Test Only”.
Note: To test the No. 2 and No. 3 SSAS press appropriate button.
8. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has been restored.
CAUTION
INF: SSAS Buttons returned to NORMAL OPERATION.
<Press ESC key to continue>
9. Press the [Esc] key three times to return to the standby display.
19

3.5 SSAS Report Test

You can test for successful transmission of the SSAS report to the address you specify, without using the button. The test report message states “!!! Test Call !!!” to alert the receiver of the message that it is a test call.
Note: This function is only available in the SSAS manager mode. Switch to this mode (see
paragraph 3.1.2) and then follow this procedure.
1. Access the Report Destination Menu, referring to section 3.2.
2. Set destination where to transmit the test.
3. Press the [] key to choose Status and then press the [Enter] key.
4. Press the [] key to choose TEST and then press the [Enter] key.
5. Press the [Esc] key to open the Update window.
6. Yes is selected; press the [Enter] key. The test report is transmitted. After it is transmitted, “Status” is automatically set to ON.
7. Press the [Esc] key twice to return to the standby display.
20

4. WATERPROOFING KIT

To mount the IC-305 and IC-307 on a bulkhead, use the optional waterproofing kit to keep water splash out of the units.
Note: This kit cannot be used if the IC-305 or IC-307 is mounted face upward. OP-xx (For IC-305)
Name Type Code No. Qty
Fixing Tape 24-009-1225 100-366-200-10 2
OP-xx (For IC-307)
Name Type Code No. Qty
Waterproofing Cover 16-023-5501 100-374-950-10 1 Fixing Tape 24-009-1225 100-366-200-10 2
1. Unfasten four screws to remove cover of IC-305/IC-307.
2. Attach supplied fixing to the underside of the cover as shown in the illustration below.
Fixing tape
3. Attach the cover.
4. For IC-307, remove the seal from the waterproofing cover and attach the cover as
shown in the illustration below.
21
17/May/2012 Y.NISHIYAMA
D-2
6/Oct/2010 Y. NISHIYAMA
D-3
16/Jun/2014H.MAKI
D-4
アンテナユニット
S-1
ANTENNA UNIT IC-115
RW-4747
0.3m TPA5FB0.4NJ5
FBA-5DFB,0.4m
A
船内LAN (HUB) パソコンなど LAN(HUB) OR PC, ETC.
B
24 VDC
C
VCTF-0.75x3C,5m,φ7
(16S0084)
12-24 VDC
100-115/ 200-230 VAC 1φ,50/60Hz
24 VDC
DPYC-2.5
*1
DPYC-4
PE IV-2sq. 保護アース
注記
*1)造船所手配。 *2)オプション。
D
*3)工場にて取付済み。 *4)コネクタクランプでアースに落とす。 *5)TB基板(16P0116)が必要。 *6)終端のIC-307はジャンパー設定を変更する。
*7)アンテナケーブルは切断して使用しないこと。
RH12BPG-3S
*1
AC IN
+
DC IN
-
*1
E
ケーブル/コネクタは選択 SELECT CABLE & CONNECTOR
12D-SFA-CV,100m,φ20: N-P-12DSFA 8D-FB-CV,50m,φ14.3: N-P-8DFB 5D-FB-CV,30m,φ10.7: N-P-5DFB
*7
TP5FBAW-5DFBB,30m,φ7.7
キーボード KEYBOARD
STP CABLE(CAT5) *1 PC: CROSS CABLE
HUB: STRAIGHT CABLE
プリンタ
24VDC
+24V 0V GND
24VDC
OUT
PRINTER PP-510
*2
+
-
1
REDアカ
2
BLKクロ
3
WHTシロ
MJ-A3SPF0018-050ZC,5m,φ11
AC/DC 電源ユニット AC/DC POWER SUPPLY UNIT PR-240
*2
1.6m
57-3036
1
36
FUSE 15A(12V) 7A(24V)
*3
*4
シロ クロ
RJ-45
P
P
17JE-23250
-02(D8C)
*4
16S0184,3m,φ8
*3
MJ-A3SPF
WHT BLK
ターミナルユニット TERMINAL UNIT
TNCP-NJ
IC-215
ANT
16P0208A
2B02
KEYBOARD
1
KDAT
2
NC
3
GND
4
+5V
5
KCLK
6
NC
LAN
1
E_TD_P
2
E_TD-N
3
E_RD_P
4
NC
5
NC
6
E_RD_N
7
NC
8
NC
*3
PRINTER
1
25
2B03 16P0209
12-24VDC
1
DC(+)
2
DC(-)
3
GND
2B10 16P0214
銅板 COPPER STRAP W=30,1.2m
JUNCTION
Vcc(ALM)
GND TD/RD-A TD/RD-B
TD-A TD-B RD-A RD-B
GND
DMC_OUT-H DMC_OUT-C DMC_CHECK
DMC_IN-C DMC_CTRL
RXD
TXD
GND
DGPS
BNC PLUG
Dsub15P
1 2 3 4 5
NC
6 7 8
9 10 11 12 13 14 15
17JE-23090 17JE-13090
-02(D8C) -02(D8C)
DTE
1
2
3
4
5
6
7
8
9
COAX. CABLE(50Ω)
*3
2m
17JE-573-10,5m,φ8 CO-0.2x5P,MAX.15m
*4
17JE-23090
DTE
-02(D8C) 1 2
RXD
3
TXD
4 5
GND
6 7 8
9
接続箱 JUNCTION BOX IC-315
*2
CO-0.2x2P,MAX.15m
*4
*1
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
*2
DGPSデコーダー DGPS DECODER
TTYCS-4
TTYCS-1(*1) OR CO-0.2x2P(*2)
TTYCS-4(*1) OR CO-0.2x5P(*2)
パソコン
1
NC
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
NC
*4
FM14-7P
*4
FM14-5P
*4
1 2 3
7
1 2 3 4 5
*1
PC
RXD TXD 0V
NC
RXD TXD NC NC 0V
I/F BOX OP16-14
航法装置 NAV EQUIPMENT
EGCプリンタ EGC PRINTER PP-505
(+)
*2
(-)
FM14-7P
1 2 3 4 5
*2
6 7
アラームユニット ALARM UNIT
P
P
遭難警報器 DISTRESS ALERT/ RECEIVED CALL UNIT
P
P
保安警報発呼器 SSAS ALERT UNIT IC-307 (No.1)
P
P
08S0157,3m
1 2
GND 08S0087
*2
CO-0.2x5P,MAX.100m
*4
16P0213D
1
VCC
2
GND
3
TD/RD-A
4
TD/RD-B
5
FG
IC-305
16P0213C
1
VCC
2
GND
3
TD/RD-A
4
TD/RD-B
5
FG
1
SSAS_OUT-H
2
NC
3
SSAS_CHECK
4
SSAS_IN-C
5
SSAS_CTRL
6
GND
TTYCS-4(*1) OR CO-0.2x5P(*2)
24VDC
FM14-7P
P
P
*4
IC-306
*2 *6
1 2 3 4 5 6 7
54321
6
IC-350を接続するとき(IC-305との共用不可) CONNECTION FOR IC-350 (DO NOT USE W/ IC-305)
選択 SELECT
P P
PP
合計 :最大200m TOTAL: UP TO 200m
EGCプリンタ
RXD-H
EGC PRINTER
TXD-H
PP-505
FG TXD-C RXD-C +9V NC
IC-315
3 4
保安警報発呼器 SSAS ALERT UNIT IC-307 (No.2)
*2 *5
(+) (-)
*2 *6
1 2 3 4 5 6
1 2
TTYCS-1
P
08S0157,3m
GND 08S0087
*1
1 2 3
保安警報発呼器 SSAS ALERT UNIT IC-307 (No.3)
1 2 3 4 5 6
最大3台まで接続可能。 MAX.3 SETS AVAILABLE.
24VDC
INMARSAT No.1/2
TR-A
アラームユニット
TR-B
ALARM UNIT
FG
IC-350
*2 *6
*2
NOTE
*1. SHIPYARD SUPPLY. *2. OPTION. *3. FITTED AT FACTORY. *4. GROUND THRU CONNECTOR CLAMP. *5. TB BOARD (16P0116) REQUIRED. *6. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.
*7. DO NOT SHORTEN ANTENNA CABLE.
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
DRAWN
20/Nov/2012
CHECKED
20/Nov/2012
APPROVED
20/Nov/2012Y.NISHIYAMA
SCALE
DWG No.
C5635-C01- T
T.YAMASAKI
T.TAKAHASHI
MASS
kg
TITLE
名称
FELCOM 15
インマルサットC船舶地球局
相互結線図
NAME
INMARSAT-C MES
INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
*2 *5
1/Apr/2010 Y.NISHIYAMA
S-2
12345
SSAS ALERT UNIT
保安警報発呼器
IC-307 (No.3)
*4 *5
12345
SSAS ALERT UNIT
保安警報発呼器
IC-307 (No.2)
43
*4
SSAS_OUT-H
NC
12345
IC-307 (No.1)
SSAS ALERT UNIT
保安警報発呼器
RXD
TXDNCDTR
DSR
CTS
RTS
パソコン
PC
123456789
-02(D8C)-02(D8C)
17JE-23090
*2
17JE-573-10,5m,φ8
*3 *3
GND
NC
*4
IC-315
接続箱
JUNCTION BOX
*3
Vcc 123
2m
GND
TD/RD-A
TD/RD-BNCTD-A
TD-B
45678
RD-A
RD-B
9
1011121314
DMC_OUT-H
GND
DMC_OUT-C
P
P
P
P
SSAS_IN-C
SSAS_CHECK
P
P
DMC_IN-C
DMC_IN-H
6
最大3台まで接続可能
6
SSAS_CTRL
GND
6
DMC_CTR 15
MAX. 3 UNITS AVAILABLE
合計:最大200m
TOTAL: UP TO 200m
TTYCS-4(*1) OR CO-0.2x5P(*2)
FELCOM 16
インマルサットMINI-C携帯移動地球局
相互結線図
INMARSAT MINI-C MES
名称
TITLE
NAME
INTERCONNECTION DIAGRAM
kg
17JE-13090
231
45678
DTE
RXD
TXD
GND
2
IC-216
通信制御ユニット
COMMUNICATION UNIT
TNCP-NJ
ケーブル/コネクタは選択
8D-FB-CV,50m,φ14.3: N-P-8DFB
12D-SFA-CV,100m,φ20: N-P-12DSFA
SELECT CABLE & CONNECTOR
5D-FB-CV,30m,φ10.7: N-P-5DFB
1
*6
ANT
TP58A15W-RG58,15m,φ5
TP5FBAW-5DFBB,30m,φ7.7
9
2B02 16P0208B
D-sub15P
SSAS
*3
FUSE
10A:12VDC
123
GND
TX/RX-A
Vcc(6.5V)
DC(-)
DC(+)
12-24VDC
123
FM-C3FP
BLKクロ
アカ RED
5A:24VDC
FM-C3FPS-002,3.5m,φ7.5
45678
NCNCNCNCNCNCNC
TX/RX-B
16P0227
GND
2B10
9
+
-
24VDC
OUT
AC/DC*2電源ユニット
ACINDC
*1
*1
DPYC-2.5
1011121314
SSAS_OUT-H
SSAS_CHECK
*1
PE
SUPPLY UNIT
AC/DC POWER
PR-240
IN
+
-
DPYC-4
15
SSAS_IN-C
SSAS_CTRL
IV-2sq.
保護アース
銅板 COPPER STRAP
W=30,1.2m
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
T.YAMASAKI
30/Mar/2010
DRAWN
CHECKED
T.TAKAHASHI
30/Mar/2010
APPROVED
MASS
SCALE
C5638-C01- L
DWG No.
TPA5FB0.4NJ5
FBA-5DFB,0.4m
ANTENNA UNIT
アンテナユニット
IC-116
RW-4747
0.3m
12-24 VDC
100-115/
A
1φ,50/60Hz
200-230 VAC
B
24 VDC
注記
*1)造船所手配。
*2)オプション。
*3)工場にて取付済み。
*4)SSAS仕様時標準支給。
*5)終端のIC-307はジャンパー設定を変更する。
*6)アンテナケーブルは切断して使用しないこと。
C
NOTE
*2. OPTION.
*1. SHIPYARD SUPPLY.
*3. FITTED AT FACTORY.
*4. STANDARD SUPPLY FOR SSAS SPEC.
*6. DO NOT SHORTEN ANTENNA CABLE.
*5. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.
12 456
S-3
3
アラームユニット
ALARM UNIT
VCC
1
P
2 3
P
アンテナユニット ANTENNA UNIT IC-118
A
TPA5FB0.4NJ5 FBA-5DFB,0.4m
DGPSデコーダー
12D-SFA-CV,100m,φ20: N-P-12DSFA 8D-FB-CV,40/50m,φ14.3: N-P-8DFB 5D-FB-CV,30m,φ10.7: N-P-5DFB
TP5FBAW-5DFBB,30m,φ7.7
COAX. CABLE(50Ω)
DGPS DECODER
17JE-23250
-02(D8C)
MJ-A3SPF
シロクロWHT
BLK
A TYPE
ORまたは
キーボード KEYBOARD
*1
AC/DC
AC IN
電源ユニット
+
AC/DC POWER
DC IN
-
SUPPLY UNIT
E
PR-240
RH12BPG-3S
MJ-A3SPF0018-050Z 5m,φ11
24 VDC
B
12 VDC
クロシロBLK
(-)
WHT
GND
DC/DCコンバータ DC/DC CONVERTER
アカ
RED
(+)
VCTF-0.75x3C,5m,φ7 (16S0084)
12-24VDC
100-115/ 200-230 VAC 1φ,50/60Hz
24 VDC
DPYC-2.5
*1
DPYC-4
PE IV-2sq. 保護アース
*1
*1
3
24VDC
OUT
*2
プリンタ PRINTER PP-510
+
-
*2
57-3036
36
15A(12V) 7A(24V)
1.5m
16S0184 3m,φ8
H230817-1(*2) 防水仕様ケーブル WATERPROOF CABLE
ターミナルユニット TERMINAL UNIT IC-218
TNCP-NJ
ANT
DGPS
BNC
USB
4
PRINTER
25
DC IN
1 DC+ 2
DC-
3
GND
JUNCTION
Vcc(ALM)
GND TD/RD-A TD/RD-B
ALM-H ALM-C
RD-A RD-B
GND 10
SSAS_OUT-H SSAS_OUT-C SSAS_CHECK
SSAS_IN-C SSAS_CTRL
LAN
銅板
COPPER STRAP
W=30,1.2m
NC
17JE-23150
-02(D8C)
1 2 3 4 5 6 7 8 9
11 12 13 14 15
RJ45
8
2m
*1
STP(CAT5)
接続箱 JUNCTION BOX IC-318
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
IV-2sq.
パソコン/HUB PC OR HUB
TTYCSLA-4(*1) OR CO-0.2x5P(*2)
TTYCSLA-1(*1) OR CO-0.2x2P(*2)
TTYCSLA-1(*1) OR CO-0.2x2P(*2)
アラームシステム ALARM SYSTEM
航法装置 NAV EQUIPMENT
TTYCSLA-4(*1) OR CO-0.2x5P(*2)
*1
P
P
4 5
遭難警報器
DISTRESS ALERT/ RECEIVED CALL UNIT
1
P
2 3
P
4 5
保安警報発呼器
SSAS ALERT UNIT
IC-307
C
IC-306
GND TD/RD-A TD/RD-B GND
VCC GND TD/RD-A TD/RD-B GND
1 2 3 4 5 6 GND
*2
*2
IC-305
*2 *3 *4 SSAS_OUT-H NC SSAS_CHECK SSAS_IN-C SSAS_CTRL
TTYCSLA-4(*1) OR CO-0.2x5P(*2)
合計 :最大200m TOTAL: UP TO 200m
IC-350を接続するとき(IC-305との共用不可) CONNECTION FOR IC-350 (DO NOT USE W/ IC-305)
選択 SELECT
P
IC-318
P
3 4
IC-307
TTYCSLA-1(*1) OR CO-0.2x2P(*2)
(No.2)
*2 *3 *4
1 2 3 4 5 6
IC-218
JUNCTION
INMARSAT No.1/2
1
TR-A
アラームユニット
2
TR-B
3
FG
IC-307(No.3)
1
P
最大3台まで接続可能 MAX. 3 UNITS AVAILABLE.
2 3 4
P
5 6
防水仕様ケーブル WATERPROOF CABLE
XM-FD-361,2m 1 2 3 4 5 6 7 8 9
10 11 12 13 14 15
アオ チャ ムラサキ ハイ
ミドリ キ ダイ モモ ウスミドリ シロ/クロ シロ/アカ クロ アカ ミズ
ALARM UNIT IC-350
*2 *3
*2
BLU BRN PPL GRY
GRN YEL ORG PNK L-GRN WHT/BLK WHT/RED BLK RED L-BLU
接続箱 JUNCTION BOX IC-318
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
D
注記
*1)造船所手配。 *2)オプション。 *3)終端のIC-307はジャンパー設定を変更する。
*4)SSAS仕様のとき標準構成。
NOTE
*1: SHIPYARD SUPPLY. *2: OPTION. *3: CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.
*4: STANDARD CONFIGURATION FOR SSAS.
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
DRAWN
12/Dec/2012
CHECKED
12/Dec/2012
APPROVED
18/Dec/2012Y.NISHIYAMA
SCALE
DWG No.
C5674-C01- D
T.YAMASAKI
H.MAKI
MASS
kg
REF.No.
16-023-3001-1
TITLE
名称
NAME
FELCOM 18 インマルサット-C 船舶地球局 相互結線図 INMARSAT-C MES INTERCONNECTION DIAGRAM
*2 *3
S-4
IC-307(No.3)
3
21456
P
P
接続箱
MAX. 3 UNITS AVAILABLE.
最大3台まで接続可能
JUNCTION BOX
*2
IC-318
BLU
3
2145678
BRN
PPL
GRY
GRN
YEL
9
1011121314
ORG
PNK
L-GRN
WHT/BLK
WHT/RED
BLK
RED
15
L-BLU
アオチャムラサキハイミドリキダイモモウスミドリ
XM-FD-361,2m
防水仕様ケーブル
合計 :最大200m
TOTAL: UP TO 200m
WATERPROOF CABLE
IC-219
2145678
JUNCTION
3
*2 *3 *4
(No.2)
3
21456
43
IC-307
*2 *3 *4
NC
SSAS_OUT-H
21456 GND
P
SSAS_CHECK 3
P
SSAS_CTRL
SSAS_IN-C
CO-0.2x5P(*2)
TTYCSLA-4(*1) OR
シロ/クロ
シロ/アカクロアカ
9
1011121314
ミズ
15
FELCOM 19
TITLE
名称
インマルサットMINI-C携帯移動地球局
相互結線図
INMARSAT MINI-C MES
NAME
INTERCONNECTION DIAGRAM
16-023-4001-1
保安警報発呼器
SSAS ALERT UNIT
IC-307
CO-0.2x5P(*2)
TTYCSLA-4(*1) OR
9
1011121314
REF.No.
H.MAKI
31/May/2012
APPROVED
SCALE MASS
kg
C5675-C01- D
DWG.No.
P
P
T.YAMASAKI
*1
IV-2sq.
15
PC OR HUB
パソコン/HUB
*1
STP(CAT5)
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
DRAWN
31/May/2012
CHECKED
*2 *4
JUNCTION BOX
IC-318
接続箱
航法装置
NAV EQUIPMENT
TTYCSLA-1(*1) OR
CO-0.2x2P(*2)
3
2145678
2m
アラームシステム
ALARM SYSTEM
TTYCSLA-1(*1) OR
CO-0.2x2P(*2)
2
1
17JE-23150
-02(D8C)
JUNCTION
Vcc(ALM)
通信制御ユニット
COMMUNICATION UNIT
IC-219
8D-FB-CV,50m,φ14.3: N-P-8DFB
12D-SFA-CV,100m,φ20: N-P-12DSFA
FBA-5DFB,0.4m
TPA5FB0.4NJ5
アンテナユニット
ANTENNA UNIT
IC-119
3
2145678
NC
GND
ANT
TNCP-NJ
5D-FB-CV,30m,φ10.7: N-P-5DFB
TD/RD-A
TD/RD-B
TP5FBAW-5DFBB,30m,φ7.7
ALM-H
A
RD-A
ALM-C
9
1112131415
GND 10
RD-B
SSAS_OUT-H
SSAS_CTRL
SSAS_IN-C
SSAS_CHECK
SSAS_OUT-C
RJ45
8
LAN
DC-
DC IN
10A(12V)
GND
321DC+
MJ-A3SPF
WHT
BLK
シロ
クロ
5A(24V)
MJ-A3SPF0016-035
3.5m
12-24VDC
B
COPPER STRAP
銅板
*1
DPYC-2.5
100-115/
200-230 VAC
W=30,1.2m
+
-
OUT
24VDC
AC/DC
AC/DC POWER
電源ユニット
IN
AC
DC
+
*1
DPYC-4
24 VDC
1φ,50/60Hz
SUPPLY UNIT
IN
-
*2
PR-240
E
*1
PE
IV-2sq.
保護アース
注記
*1)造船所手配。
*2)オプション。
C
*3)終端のIC-307はジャンパー設定を変更する。
*4)SSAS仕様のとき標準構成。
NOTE
*1: SHIPYARD SUPPLY.
*2: OPTION.
*3: CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.
*4: STANDARD CONFIGURATION FOR SSAS.