COLOR LCD SOUNDER
FCV-1100L
9-52 Ashihara-cho, 9-52 Ashihara-cho,
*00080922000* *00080922000*
*00080922000* *00080922000*
*IME23670C20* *IME23670C20*
Nishinomiya, Japan Nishinomiya, Japan
Telephone : Telephone : 0798-65-2111 0798-65-2111
faxfa
ll rights reserved.
ll rights reserved.
PUB.No. PUB.No. IME-23670-C2 IME-23670-C2
0798-65-4200 0798-65-4200
::
Printed in Japan Printed in Japan
Your Local Agent/Dealer Your Local Agent/Dealer
IRST EDITION :
IRST EDITION :AUG.AUG. 2001 2001
C2 C2 :: DEC. DEC. 10,2003 10,2003
(( TENI TENI ))
FCV-1100L FCV-1100L
* 0 0 0 8 0 9 2 2 0 0 0 * * 0 0 0 8 0 9 2 2 0 0 0 *
*IME23670C20* *IME23670C20*
* I M E 2 3 6 7 0 C 2 0 * * I M E 2 3 6 7 0 C 2 0 *
SAFETY INSTRUCTIONS
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment
unless totally familiar with
electrical circuits and
service manual.
Only qualified personnel
should work inside the
equipment.
Turn off the power at the switchboard
before beginning the installation.
Fire or electrical shock can result if the
power is left on.
Do not install the equipment where it
may get wet from rain or water splash.
Water in the equipment can result in fire,
electrical shock or equipment damage.
WARNING
Install the transducer according
to the installation instructions.
Failure to install the transducer correctly
may result in water leakage and damage to
the ship's hull.
For wooden or FRP vessel using a steel
tank, attach a zinc plate to the hull to
prevent electrolytic corrosion.
Electrolytic corrosion can, in the worst
case, result in loss of the transducer.
Be sure no water leaks in at the transducer mounting location.
Water leakage can sink the vessel. Also,
confirm that the transducer will not loosen
by ship's vibration. The installer of the
equipment is solely responsible for the
proper installation of the equipment.
FURUNO will assume no responsibility for
any damage associated with improper
installation.
Be sure that the power supply is
compatible with the voltage rating of
the equipment.
Connection of an incorrect power supply
can cause fire or equipment damage. The
voltage rating of the equipment appears
on the label above the power connector.
i
CAUTION
Ground the equipment to
prevent mutual interference.
Observe the following compass safe
distances to prevent interference to a
magnetic compass:
Standard
compass
CV-1100L
Do not allow warm water or any other
liquid other than seawater or freshwater
to contact the transducer.
Damage to the transducer may result.
0.7 m 0.5 m
Steering
compass
CAUTION
The transducer cable must he handled
carefully, following the guidelines
below.
• Keep fuels and oils away from the
cable.
• Locate the cable where it will not be
damaged.
• The cable sheath is made of chloro phrene or polychloride vinyl, which
are easily by damaged plastic solvents
such as toulene. Locate the cable
well away from plastic solvents.
Do not install the transducer where
noise or air bubbles is present.
Performance will be affected.
ii
TABLE OF CONTENTS
SYSTEM CONFIGURATION................................................................................iv
EQUIPMENT LISTS ..............................................................................................v
1. MOUNTING ...................................................................................................1-1
1.1 Display Unit...............................................................................................................1-1
1.2 Transducer.................................................................................................................1-4
1.3 Water Temperature Sensor (option)...........................................................................1-4
2. WIRING..........................................................................................................2-1
2.1 Wiring Standard Equipment.......................................................................................2-2
2.2 Wiring Optional Equipment........................................................................................2-3
2.3 Input/Output Sentences.............................................................................................2-3
3. INITIAL SETTING..........................................................................................3-1
3.1 Language Setting.......................................................................................................3-1
3.2 Transducer Data........................................................................................................3-2
3.3 Water Temperature Sensor Setting............................................................................3-7
3.4 Nav Data, Heading Sensor Setting ............................................................................3-9
3.5 Propagation Velocity................................................................................................ 3-11
3.6 Demonstration Mode................................................................................................3-12
3.7 Restoring Default Settings.......................................................................................3-13
APPENDIX 1 TRANSDUCER 50BL-12/50BL-24H ........................................AP-1
APPENDIX 2 NEW BLT TRANSDUCERS......................................................AP-2
PACKING LISTS ............................................................................................... A-1
OUTLINE DRAWINGS...................................................................................... D-1
SCHEMATIC DIAGRAM ....................................................................................S-1
iii
SYSTEM CONFIGURATION
iv
EQUIPMENT LISTS
Standard supply
Name Type Code No. Qty Remarks
Display unit CV-1100L - 1
Spare Parts SP02-04401 001-402-100 1 set Fuse
Accessories FP02-05300 000-012-509 1 set Hood
EQUIPMENT LISTS
Installation Materials
CP02-06900 000-012-508
1 set
MJ-A3SPF0013-035 (3.5 m),
CP02-06901
Options
Name Type Code No. Qty Remarks
Transducer Transducer available in 1, 2 and 3 kW models. See page vi – xiii for
details. No selection also available.
MJ-A6SPF0012-050 000-134-424 1
MJ-A6SPF0012-100 000-133-817 1
Cable Assy
Water Temperature
Sensor
Sensor
Rectifier PR-62
MJ-A6SPF0011-050 000-132-244 1
MJ-A6SPF0011-100 000-132-336 1
NCS255AD-254P-L500 000-142-518 1
T-02MSB 000-040-040 1 Thru-hull mount
T-02MTB 000-040-026 1 Transom mount
T-03MSB 000-040-027 1 Thru-hull mount
ST-02MSB 000-137-986 1 Speed/Temperature
ST-02PSB 000-137-987 1
000-013-484 100 VAC
000-013-485 110 VAC*
000-013-486 220 VAC
000-013-487
*: Use this type for 115 VAC.
6P-6P, 5m, for
navigator
6P-6P, 10m, for
navigator
6P-4P, 5m, for
navigator
6P-4P, 10m, for
navigator
For dual –frequency
transducer
1
230 VAC
v
EQUIPMENT LISTS
Available transducers
1 kW transducer
Frequency
(kHz)
28/50
28/68
28/88
28/200
50/88
50/200
68/200
88/200
Hull
Material
Steel - FRP
Steel TWB-6000 (2) T-656
FRP
Steel - FRP
Steel - FRP
Steel TWB-6000 (2) T-657
FRP
Steel - FRP
Steel - FRP
Steel TWB-6000 (2) T-658
FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - -
FRP
Transducer
28F-8
50B-6/6B
28F-8
50B-9/9B
28F-8
50F-8G
28F-8
68F-8H
28F-8
88B-8
28F-8
200B-5S
50B-6/6B
88B-8
50B-9/9B
88B-8
50F-8G
88B-8
50B-6/6B
200B-5S
50B-9/9B
200B-5S
50F-8G
200B-5S
50/200-1T
50/200-1ST
68F-8H
200B-5S
88B-8
200B-5S
Thru-Hull
Pipe
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
Tank
- -
vi
2 kW transducer
EQUIPMENT LISTS
Frequency
(kHz)
28/50
28/68
28/88
28/200
50/88
50/200
68/200
Hull
Material
Steel TFB-7000 (2) T-634
FRP
Steel - FRP
Steel TFB-7000 (2) T-636
FRP
Steel TFB-7000 (2) T-638
FRP
Steel TFB-7000 (2) T-643
FRP
Steel TFB-7000 (2) T-645
FRP
Steel TFB-7000 (2) FRP
Transducer
28F-18
50B-12
28F-18
68F-30H
28F- 18
88B-10
28F-18
200B-8/8B/8N
50B-12
200B-8/8B/8N
50B-12
200B-8/8B/8N
68F-30H
200B-8/8B/8N
Thru-Hull
Pipe
- -
TRB-1100 (2) T-634-F
TFB-1100 ( 2) T-636-F
TFB-1100 ( 2) T-638-F
TFB-1100 ( 2) T-643-F
- -
TFB-1100 (2) -
Tank
88/200
Steel TFB-7000 (2) T-649
FRP
88B-10
200B-8/8B/8N
TFB-1100 ( 2) T-649-F
vii
EQUIPMENT LISTS
3 kW transducer
Frequency
(kHz)
28/50
28/68
28/88
28/107
28/150
28/200
50/88
50/107
50/150
50/200
68/107
68/150
68/200
88/150
88/200
107/200
Hull
Material
Steel TFB-7000 (2) T-681
FRP
Steel - FRP
Steel TFB-7000 (2) T-682
FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel TFB-7000 (2) T-682
FRP
Steel - FRP
Steel TFB-7000 (2) T-683
FRP
Steel TFB-7000 (2) T-683
FRP
Steel - FRP
Steel TFB-7000 (2) T-646
FRP
Steel TFB-7000 (2) T-646
FRP
Steel - FRP
Steel TFB-7000 (2) T-685
FRP
Steel TFB-7000 (2) FRP
Transducer
28F-24H, 50F-24H
28F-24H, 68F-30H
28F-24H, 88F-126H
28F-24H, 100B-10R
50B-6/6B, 88B-8
28F-24H, 200B-12H
50F-24H, 88F-126H
50F-24H, 100B-10R
50F-24H, 150B-12H
50F-24H, 200B-12H
68F-30H, 100B-10R
68F-30H, 150B-12H
68F-30H, 200B-12H
88F-126H, 150B-12H
88F-126H, 200B-12H
100B-10R, 200B-12H
Thru-Hull
Pipe
TRB-1100 (2) T-681-F
- -
TRB-1100 (2) T-682-F
- -
- -
- -
TRB-1100 (2) T-682-F
- -
TRB-1100 (2) T-683-F
TFB-1100 (2) T-638-F
- -
TFB-1100 (2) T-646-F
TFB-1100 (2) T-646F
- -
TFB-1100 (2) T-685-F
TFB-1100 (2) -
Tank
viii
1 kW/2 kW transducer
EQUIPMENT LISTS
Output
(W)
1 k/2 k
Frequency
(kHz)
28/50
28/68
28/88
28/200
50/88
Hull
Material
Steel - FRP
Steel - FRP
Steel - FRP
Steel TWB-6000 (2) T-657
FRP
Steel - FRP
Steel - FRP
Steel TFB-7000 (2) T-636
FRP
Transducer
28F-8
50B-12
28F-8
68F-30H
28F-8
88B-10
28F-8
200B-8/8B/8N
50B-6/6B
88B-10
50B-9/9B
88B-10
50F-8G
88B-10
Thru-Hull
Pipe
- -
- -
- -
- -
- -
- -
TRB-1100 (2) T-636-F
Tank
Steel - FRP
Steel TWB-6000 (2) T-658
50/200
FRP
Steel TFB-7000 (2) T-638
FRP
Steel - -
68/200
FRP
Steel TWB-6000 (2) T-659
88/200
FRP
50B-6/6B
200B-8/8B/8N
50B-9
200B-8/8B/8N
50F-8G
200B-8/8B/8N
68F-8H
200B-8/8B/8N
88B-8
200B-8/8B/8N
- -
- -
TFB-1100 ( 2) T-638-F
- -
- -
ix
EQUIPMENT LISTS
1 kW/3 kW transducer
Output
(W)
1 k/3 k
Frequency
(kHz)
28/45
28/50
28/68
28/88
28/150
28/107
28/150
28/200
50/88
50/107
50/150
Hull
Material
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Transducer
28F-8
45F-12H
28F-8
50F-24H
28F-8
68F-30H
28F-24H,
100B-10R
28F-8
88F-126H
28F-8
100B-10R
28F-8
150B-12H
28F-8
200B-12H
50B-6/6B
88F-126H
50B-9B
88F-126H
50F-8G
88F-126H
50B-6/6B
100B-10R
50B-9/9B
100B-10R
50F-8
100B-10R
50B-6/6B
150B-12H
50B-9/9B
150B-12H
50F-8G
150B-12H
Thru-Hull
Pipe
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
Tank
x
Output
(W)
1 k/3 k
Frequency
(kHz)
50/200
68/107
68/150
68/200
88/150
88/200
EQUIPMENT LISTS
Hull
Material
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Transducer Thru-Hull Pipe Tank
50B-6/6B
200B-12H
50B-9/9B
200B-12H
50F-8G
200B-12H
68F-8H
100B-10R
68F-8H
150B-12H
68F-8H
200B-12H
88B-8
150B-12H
88B-8
200B-12H
- -
- -
- -
- -
- -
- -
- -
- -
xi
EQUIPMENT LISTS
2 kW/3 kW transducer
Output
(W)
2 k/3 k
Frequency
(kHz)
28/45
28/50
28/68
28/88
28/107
28/150
28/200
50/88
50/107
50/150
50/200
68/107
68/150
68/200
88/150
88/200
Hull
Material
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel TFB-7000 (2) T-636
FRP
Steel TFB-7000 (2) T-637
FRP
Steel - FRP
Steel - FRP
Steel TFB-7000 (2) T-643
FRP
Steel TFB-7000 (2) T-644
FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Transducer Thru-Hull Pipe Tank
28F-18
45F-12H
28F-18
50F-24H
28F-18
68F-30H
28F-18
88F-126H
28F-18
100B-10R
28F-18
150B-12H
28F-18
200B-12H
50B-12
88F-126H
50B-12
100B-10R
50B-12
150B-12H
50B-12
200B-12H
68F-30H
100B-10R
68F-30H
150B-12H
68F-30H
200B-12H
88B-10
150B-12H
88B-10
200B-12H
TRB-1100 (2) T-636-F
TRB-1100 (2) T-637-F
TRB-1100 (2) T-643-F
TRB-1100 (2) T-644-F
- -
- -
- -
- -
- -
-
- -
- -
- -
- -
- -
- -
xii
3 kW/2 kW transducer
EQUIPMENT LISTS
Output
(W)
3 k/2 k
Frequency
(kHz)
28/50
28/68
28/88
28/200
50/88
50/200
68/200
88/200
107/200
Hull
Material
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel - FRP
Steel TFB-7000 (2) T-647
FRP
Steel - FRP
Steel TFB-7000 (2) T-649
FRP TRB-1100 (2) T-649-F
FRP
Transducer Thru-Hull Pipe Tank
28F-24H
50B-12
28F-24H
68F-30H
28F-24H
88B-10
28F-24H
200B-8/8B/8N
50F-24H
88B-10
50F-24H
200B-8/8B/8N
68F-30H
200B-8/8B/8N
88F-126H
200B-8/8B/8N
100B-10R
200B-8/8B/8N
TRB-1100 (2) T-645-F
- -
- -
- -
- -
- -
- -
-
- -
xiii
EQUIPMENT LISTS
This page is intentionally left blank.
xiv