Furuno AD-100 User Manual

4.6 (7)

Back

Furuno AD-100 User Manual

 

TABLE OF CONTENTS

 

SPECIFICATIONS....................................................................................................................................

-1-

EQUIPMENT LIST....................................................................................................................................

-2-

CHAPTER 1 OPERATION .......................................................................................................................

1-1

1. FRONT PANEL...............................................................................................................................

1-1

2. OPERATION...................................................................................................................................

1-1

CHAPTER 2 MAINTENANCE .........................................................................................................

2-1 to 2-4

1. FUSE REPLAEMENT .....................................................................................................................

2-1

2. MINOR TROUBLESHOOTING .......................................................................................................

2-1

3. SELF TEST ....................................................................................................................................

2-2

1)

Sequence..............................................................................................................................

2-2

2)

LED status according to DIP switch setting ..........................................................................

2-4

CHAPTER 3 INSTALLATION .......................................................................................................

3-1 to 3-11

1. INSTALLATION ..............................................................................................................................

3-1

1)

General notes on installation ................................................................................................

3-1

2)

Mounting the unit. .................................................................................................................

3-1

3)

Mounting dimensions ............................................................................................................

3-2

4)

Mounting procedure ..............................................................................................................

3-2

2. CABLE CONNECTION ..................................................................................................................

3-3

1)

Fabrication of 5c cable..........................................................................................................

3-3

2)

Fabrication of 5 pair cable.....................................................................................................

3-4

3. EXTERMAL POWER SUPPLY ......................................................................................................

3-5

1)

Jumper wire ..........................................................................................................................

3-5

2)

Cable connection ..................................................................................................................

3-5

4. SETTING THE DIP SWITCHES AND JUMPER WIRES ...............................................................

3-6

1)

DIP switch and jumper wire setting ......................................................................................

3-7

2)

Default setting .......................................................................................................................

3-8

3)

Setting procedure..................................................................................................................

3-8

4)

Function of the DIP switch and jumper wire .........................................................................

3-9

CHAPTER 4 PARYS LOCATION .............................................................................................................

4-1

CHAPTER 5 DIGITAL INTERFACE .........................................................................................................

5-1

OUTLINE DRAWING .............................................................................................................................

D-1

INTERCONNECTION DIAGRAM........................................................................................................

.... S-1

Declaration of conformity to type

 

SPECIFICATIONS OF AD-100 A-D CONVERTER

General

The AD-100 A-D converter converts the gyro compass reading into digital coded bearing data and display it on a 4 digit LED display.

The digital bearing output may be sent to navigation equipment such as radar, GPS navigator and autopilot.

Specifications

 

 

 

 

1.

Input Signal

Gyro repeater signal (AC Synchro, DC Synchro or Step-by-Step) DIP

 

 

 

switch provided to select input signal.

2.

Input Voltage

AC Synchro Type --- 20VAC to 135VAC (Rotor)

 

 

 

 

 

20VAC to 135VAC (Stator)

 

 

 

 

 

50/60Hz, 400Hz or 500Hz

 

 

 

DC Synchro Type -- 20VDC to 100VDC (Rotor)

 

 

 

 

 

20VAC to 100VAC (Stator)

 

 

 

Step-by-Step --------- 20VDC to 100VDC

3.

Power Consumption

Less than 5W

 

 

4. Tracking Speed

30º/sec

 

 

 

5.

Bearing Display

4 digit LED display

6.

Data Output

AD–10S format ----- Photo-coupler driver type, 4 digit BCD code,

 

 

 

 

 

MSB transmission order.

 

 

 

IEC61162-1 ---------- HDT, VHW

 

 

 

or NMEA0183

RS-485 level

 

 

 

Ver. 1.5/2.0/3.0

Baud rate 4800 and 38,400 bps

7.

Output Ports

AD–10S format ------- 6 ports

 

 

 

IEC61162-1 ----------- 1 port

 

 

 

or NMEA0183

 

 

 

 

 

Ver. 1.5/2.0/3.0

 

 

8.

Data Transmission

AD–10S format ------- Switchable between 25ms and 200ms.

 

 

 

 

 

Use 25ms for radar only.

 

 

 

IEC61162-1 ----------- Selectable among 25ms, 100ms, 200ms and 1s.

 

 

 

or NMEA0183

Note: For 25ms, 100ms or 200ms, only HDT is

 

 

 

 

 

output.

 

 

 

Ver. 1.5/2.0/3.0

The 25ms setting sets baud rate to 38,400 bps.

9.

Color

Cabinet ---------------- 2.5GY 5/1.5 Newtone No.5

 

 

 

Front Panel ----------- N3.0

Program Number

 

 

 

 

 

 

 

 

 

 

 

Program No.

Version No.

 

 

 

645-1410

 

05

 

- 1 -

EQUIPMENT LIST

COMPLETE SET

 

No.

Name

Type

Code NO.

Qty

Remarks

 

1

Main Unit

AD-100

000-040-104

1

 

 

2

Accessories

FP64-00400

000-040-107

1

 

 

3

Installation Materials

CP64-00500

000-040-106

1

 

 

4

Spare Parts

SP64-00400

000-040-105

1

 

ACCESSORIES

 

 

 

 

 

 

 

 

 

 

 

 

No.

Name

Type

Code NO.

Qty

Remarks

 

1

Tapping Screw

5x20 SUS304

000-802-081

4

 

 

2

Knob Bolt

KT-B M6x10

000-861-924

2

 

 

3

Flat Washer

M5 SUS304

000-864-128

4

 

 

4

Flat Washer

M6 SUS304

000-864-129

2

 

 

5

Hanger Bracket

RUA-1003

380-010-030

1

 

INSTALLATION MATERIALS

 

 

 

 

 

 

 

 

 

 

 

 

No.

Name

Type

Code NO.

Qty

Remarks

 

1

NH Connector Assembly

64-45 (5P)

004-441-960

6

 

 

2

NH Connector Assembly

64-107 (4P)

004-412-000

1

 

 

3

VH Connector Assembly

64-47 (5P)

004-411-980

1

 

 

4

VH Connector Assembly

64-48 (3P)

004-411-990

1

 

 

5

Heat-shrink Tube

5x0.25 0.1m

000-117-772

2

Black

 

6

Heat-shrink Tube

3x0.25 1m

000-568-172

1

Black

SPARE PARTS

 

 

 

 

 

 

 

 

 

 

 

 

No.

Name

Type

Code NO.

Qty

Remarks

 

1

Glass Tube Fuse

FGMB 2A 250V

000-122-000

4

 

- 2 -

CHAPTER 1 OPERATION

1. FRONT PANEL

FRONT PANEL

2.OPERATION

(1)When you turn on the power of a gyrocompass, the AD-100 is powered on simultaneously.

(2)Adjust the brightness of the Bearing Display and the backlighting of the keys with the Dimmer Control.

(3)The Bearing Display is blinking, which means the data is not yet sending out from AD-100.

(4)Once you press HOLD key, the data is sent out changing the Bearing Display from blink to light. In this state, the Hold lamp does not light yet. Prior to press of the HOLD key, adjust the Display with the UP or DOWN keys to get the same reading to the gyrocompass.

Each pressing of the key changes the display by 0.1 degrees. For faster change, press and hold down the key to change the display in 1.0 degree steps.

(5)If Power fail detection is preset to OFF (See page 3-10), switching on the gyrocompass makes the data of AD-100 output immediately. Therefore, it is necessary to ensure that the reading between the gyrocompass and the Display is same after the gyrocompass reading stabilizes.

(6)To freeze the display, press the HOLD key. In this case the HOLD lamp lights. To restart the display press the HOLD key. Since the computing circuit is disengaged from the gyrocompass during HOLD, readjust the Display to get the same reading to the gyrocompass.

1-1

CHAPTER 2 MAINTENANCE

1. FUSE REPLACEMENT

To protect the unit from serious damage, four 2A fuses are provided on a P.C. board. The fuses protect against overvoltage or internal fault of the equipment. If a fuse blows, find the cause of the problem before replacing it.

CAUTION

Do not use a fuse rated more than 2A, since it may cause more serious damage to the equipment.

2. MINOR TROUBLESHOOTING

Operating problems are most likely caused by loose connectors or wrong setting of DIP switches. The table below provides simple troubleshooting which can be done by the operator.

Symptom

Possible Cause

Remedy

No display

*Dimmer control turned

*Turn the control

 

fully CCW.

clockwise.

 

*Gyrocompass not on.

*Turn on the power..

 

*External power supply is

*Turn on the power.

 

turned off.

 

 

*Flat cable between the two

*Reconnect.

 

P.C. Board is loose.

 

 

*Blown fuse.

*Check supply voltage.

 

 

Replace fuse.

 

*No power because of wrong

*Correct JP1, JP4 and JP5

 

jumper setting.

to the right setting.

 

*Gyrocompass not connected.

*Connect gyrocompass.

Display is fixed

*DIP switch SW1 is set wrong.

*Correct the setting.

on “000.0”.

 

 

No data output

*Loose data output connector.

*Tighten the connector.

 

*JP6 and/or JP7 not connected.

*Connect JP6 and JP7.

Bearing display is

*Hold function is turned on.

*Press HOLD key to release

frozen.

 

the HOLD function.

A value between “000.0”

*Power fail detection or Stator

*Check the connection with

and “359.9” flashes.

signal breaking detection is

the Gyrocompass.

 

activated.

*Press COUNT-UP or

 

 

COUNT-DOWN key to

 

 

match the AD-100

 

 

indication with the

 

 

Gyrocompass indication,

 

 

and then press HOLD key.

“999.9” flashes

*Stator signal breaking detection

*Check the connection with

 

is activated.

the Gyrocompass.

- continued - 2-1

Loading...