Furrion FF40S15A-BL User Manual

Page 1
40” Built-in Electric Fireplace
Operating and Installation Instructions
This manual is for use with
Furrion FF40S15A-BL 40” Built-in Electric Fireplace
1
Page 2
Welcome
Furrion FF40S15A-BL 40” Built-in Electric Fireplace
SUITABLE FOR DOMESTIC HOUSEHOLD USE, RV’s & MODULAR HOMES
Before installation and use, please read all instructions carefully. This will ensure safe use and reduce the risk of injury.
2
Page 3
Contents
IMPORTANT SAFETY INSTRUCTIONS ............................................. 4-6
Installation ......................................................................................... 7-8
Operation ........................................................................................... 9
Troubleshooting ................................................................................10
Care and maintenance & Warranty .................................................11
3
Page 4
IMPORTANT SAFETY INSTRUCTION
PLEASE READ ALL OF THE INFORMATION IN THIS OPERATING MANUAL, INCLUDING ALL SAFETY, OPERATING, AND MAINTENANCE INFORMATION. TO AVOID THE POTENTIAL RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, USERS SHOULD FOLLOW THE DIRECTIONS AND WARNINGS IN THIS MANUAL.
1. Read all instructions before using this fireplace.
2. Do not use this fireplace outdoors.
3. This fireplace is not intended for use in bathrooms, laundry areas or similar indoor locations. Never position the fireplace where it may fall into a bathtub or other water container.
4. Do not run the power cord under carpeting. Do not cover the power cord with throw rugs, runners, or the like. Arrange the power cord away from high traffic areas or where it may be tripped over.
5. To disconnect the fireplace, turn controls to off, then remove the plug from the outlet.
6. Connect to properly grounded outlets only. Always plug fireplaces directly into a wall outlet/recepta­cle. Never use with an extension cord or reloadable power tap (outlet/power strip).
7. To prevent a possible fire, do not block the fireplace’s air intakes or the exhaust in any manner. Do not operate the fireplace on soft surfaces such as a bed where the openings may become blocked.
8. There is a thermostat protective device inside the fireplace. When the inner temperature exceeds
a predefined level or abnormal heating occurs, the thermostat protective device cuts off the power supply to avoid damage to the fireplace or risk of fire.
9. Use this fireplace only as described in this manual. Any other use is not recommended by the manufac­turer and may cause fire, electrical shock, or injury.
SAVE THESE INSTRUCTIONS
WARNING: This fireplace is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this fireplace. Keep combustible material, such as furniture, pil­lows, bedding, paper, clothes and curtains at least 3 ft. (0.9 meters) from the front of the fireplace and keep them away from the sides and rear.
WARNING: Extreme caution is necessary when any fireplace is used by or near children or invalids and whenever the fireplace is left operating and unattended.
WARNING: Do not operate any fireplace with a damaged cord or plug or after the fireplace
4
Page 5
IMPORTANT SAFETY INSTRUCTIONS
malfunctions or has been dropped or damaged in any manner. Return the fireplace to an authorized service facility for examination, electrical or mechanical adjustment, or repair.
WARNING: Do not insert or allow foreign objects into the ventilation or exhaust openings as this may cause an electric shock, fire, or damage the fireplace.
WARNING: The fireplace contains hot and potentially flammable components. Do not use in areas where gaso­line, paint, or other flammable liquids are used or stored.
CAUTION: While in use, the top center of the fireplace can become hot to the touch and may cause serious injury or burns. Always supervise small children around the fireplace. Do not place any cloth, deco­rations, or otherwise obstruct the fireplace outlet as this may cause a fire and serious injury may result.
GROUNDING INSTRUCTIONS
DANGER: Improper
connection of the equipment­grounding conductor can result in a risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the product is properly grounded. Do not
modify the plug provided with the product. If it will not fit the outlet, have a proper outlet installed by a qualified
electrician. This product must be grounded. If it should malfunction or breakdown, proper grounding provides a path of least resistance for electric current to flow and reduces the risk of electric shock. This product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
This fireplace is for use on 120 volt circuits and has a grounded plug. An adapter is available for connecting three-blade grounding type plugs to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box.
The adapter should not be used if a three-slot grounded receptacle is available.
A
Grounding Pin Cover of Grounded Outlet Box
Adapter
Grounding Lug
Metal Screw Cover of Grounded Outlet Box
B
5
Page 6
IMPORTANT SAFETY INSTRUCTIONS
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
Modifications not approved by the party responsible for compliance could
void user’s authority to operate the equipment.
This Class B digital apparatus complies with Canadian ICES-003.
6
Page 7
Installation
First Time Use
Remove the marketing sticker from the front glass.
Marketing Sticker
Installation
1. Remove the front glass assembly and place the unit into the cabinet. The
height, width, and depth of the cabinet’s opening is outlined in the picture below.
35 7⁄8
16 ¼
5 “
7
Page 8
Installation
2. Secure the fireplace to the cabinet with the (4) supplied mounting screws.
3. Align the glass assemble into the grooves on the left and right sides of the
unit and gently slide into place and secure the glass assembly to the fireplace body with the (4) supplied mounting screws.
Note: If installing the fireplace
in an RV, ensure to leave a minimum clearance of 6 inches from any object when the unit is turned off and 3 feet from the unit when in operation.
CAUTION: Do not install the re-
place insert directly on carpet or similar surfac­es which may restrict air ow.
CAUTION: If installing the fireplace
in a carpeted area, place a one-piece solid, flat surface under the fireplace.
8
Page 9
Operation
Product Specications
Rating voltage 120Vac 60Hz
AMPS 12.5A
WAT TS 1500W
Control Panel
Warning: This electric fireplace must be properly installed before it is used.
Note: The element retains heat after shut down. There is a built-in cool down
period of 30 seconds before the blower shuts off completely.
Note: To operate correctly, the remote control must be pointed toward the
control panel.
Function Icon Description
POWER
Flame
Fireplace
Turn on or turn off the fireplace.
Select one of four brightness levels.
1. Press once to activate the low heat setting.
2. Press the button a second time to activate the high heat setting.
3. Press the button a third time to turn off the fireplace.
4. After turning on the fireplace, press this button for 3 seconds to select the desired temperature setting.
Note: pressing the power button for 3 seconds will
toggle between °C and °F.
9
Page 10
Operation & Troubleshooting
Function Icon Description
Timer
Temperature down
Temperature up
Pressing the button will cycle through the timer setting: 30 minutes to 5 hours.
Decrease the heat output (remote control only).
Increase the heat input (remote control only).
Troubleshooting
Problem Root cause Corrective action
Unplug the fireplace and remove the back panel. Check that the
Display shows
Display shows
The thermostat sensor is broken or disconnected.
Manual reset overheat protection has triggered.
thermostat is plugged into the main circuit board. If this does not solve the problem, contact customer service for a replacement thermostat sensor.
Inspect the fireplace and check that the air inlets and outlets are not blocked as this may cause overheating.
Fireplace does not blow warm air.
The RED LED is blinking constantly and the blower motor does not start.
10
Cool down cycle
Thermostat setting is preventing the fireplace from turning on.
Air vents may be obstructed.
Normal operation will continue for 30 seconds before shutting down.
Adjust the temperature setting to ensure that the thermostat is set higher than the current room temperature.
Ensure there are no obstructions within a minimum distance of 6 inches from the air vents. Press the Power button to restart the fireplace.
Page 11
Troubleshooting & Care and Maintenance
Problem Root cause Corrective action
The slide out moves and the fireplace turns off automatically.
Remote control is not working
Overcurrent protection has been triggered.
Weak or defective batteries
Poor signal
Distance
After the slide out stops, press the power button to restart to the fireplace.
Replace the remote batteries.
Press the remote control buttons with an even motion and gentle pressure. Repeatedly pressing buttons in rapid succession may cause the remote to malfunction.
Operate the remote at a distance less than 20 feet from the front of the fireplace. Point the remote at the control panel.
Care and maintenance
• The fan and flame generator motors are pre-lubricated for extended bearing life and require no further lubrication. However, we recommend periodic cleaning/vacuuming of the fan/fireplace.
• Buff the trim using a soft cloth slightly dampened with a citrus oil based product (available at supermarkets and hardware stores). DO NOT use brass polish or household cleaners. These products will damage the metal trim.
• Make sure the unit is turned OFF and unplugged before cleaning the fireplace.
Warranty
We are confident that you will be delighted with this purchase. Should this product be defective in workmanship or materials or fail under normal use, we will repair or replace it for a period of up to one (1) year from the date of purchase.
This warranty gives you specific rights and you may also have other rights which vary from state to state.
11
Page 12
Furrion reserve the right to alter the information in this document without prior notice. Furrion shall not be liable for technical or editorial errors or omissions contained herein.
FURRION.COM
12
IM- FF40S15A-BL REV.0
Loading...