Furrion F50-ATS User Manual

F50-ATS
50amp 125/250V Automatic Transfer Switch
Furrions ATS is used to safely switch automatically between mutiple power sources
Furrion’s 50amp Automatic Transfer Switch with built in safe switch interlock system is used to automatically switch between two separate 120/240 volt AC power sources, these power sources can be from a Generator, shore power cord or inverter.
The function of the Furrion Automatic Transfer Switch is to provide a safe and smooth switch over from an inverter or shore power cord automatically when a generator is started and brought online, the Furrion ATS oers the added feature of a mechanical interlock between contactors to ensure both contactors cannot be closed in parallel which could otherwise create an over voltage situation on the output line.
The electrical contacts in the transfer switch are normally in the open position, once AC voltage is applied to input 1 this will automatically close the contacts in contactor 1 and feeds the output line from the shore power cord or inverter. Once AC power from the Generator is sensed by the transfer switch at Input 2 terminals, this will start a timer and automatically switch over to generator power supply after a 20-30 second delay which ensures the generator has sucient time to run up to speed before electrical load is applied.
PLEASE READ ALL SAFETY INSTRUCTIONS BEFORE INSTALLING THIS TRANSFER SWITCH!
WHEN PROTECTED BY A MOLDED CASE CIRCUIT BREAKER RATED TO 50AMPS OR LESS, THIS LINE/GENERATOR SWITCH IS RATED TO 5000 SYMMETRICAL AMPS.
BEFORE PREFORMING MAINTENANCE OR INSTALLATION PLEASE ENSURE TO ISOLATE ALL POWER SOURCES!
Ensure generator is shut o and auto start feature (if applicable) is isolated.
!
Conrm external power cord is disconnected and stored in an area where it
!
cannot mistakenly be plugged in. Conrm the inverter (if used) has been disconnected.
!
Conrm with an AC/DC electrical tester that no voltage is present at any of the
!
connections before beginning installation or maintenance. Label all electrical parts with a warning tag to show work is in progress before
!
beginning work.
Furrion warranties this transfer switch in the Continental Untied States of America and Canada from defects in materials or workmanship under normal use for 1 year from date of purchase.
INSTALLING YOUR F50-ATS:
75755050151515505020757560
60
202020
20
202020
20
There are 3 common installation congurations for the Furrion ATS series:
Conguration 1: Double power feed This is the standard installation used between a shore power cord and generator.
DISTRIBUTION PANEL /
BRANCH CIRCUITS
EXAMPLE. 1
Typical RV Wiring Layout
50Amp Generator/Power Cord System Wiring
Output feed
F50-ATS
SHORE POWER CORD
50Amp 125/250 VAC 12KW
FURRION PULL SMART PLUG FEATURED BELOW
Transfer switch
Input 2
Input 1
50Amp 125/250 VAC 12KW Generator
GENERATOR
Conguration 2: Triple power feed (same rating) This conguration is used when a inverter is added to the system and requires automatic switch over. See Diagram 2 which illustrates this conguration
EXAMPLE. 2
Main Power Supply Wiring, with 50amp Sub Panel Inverter Feed.
Output feed
DISTRIBUTION PANEL /
BRANCH CIRCUITS
SHORE POWER CORD
50Amp 125/250 VAC 12KW
FURRION PULL SMART PLUG FEATURED BELOW
F50-ATS
Transfer switch
Input 2
F50-ATS
Transfer switch
Input 2
Output feed
Input 1
Input 1
50Amp 125/250 VAC 12KW Generator
POWER INVERTER
MAX 6000W
GENERATOR