CN-1800S
Instructions
CONTRACTOR SERIES SmartSequencer
PRIMARY LINK
SECONDARY LINK
ETHERNET
DELAY 1
DELAY 2
DELAY 3
PROTECTION OK
EXTREME VOLTAGE
UNSWITCHED
15 AMPS
PUSH TO RESET
ON
OFF
REMOTE
CN-1800S
Contractor Grade Power Management with
SmartSequencing™
Features:
SmartSequencing™ technology allows large complex A/V systems to be
safely power cycled on and off sequentially, with a simple key turn or press
of a button.
Series Multi-Stage Protection (SMP) ensures zero downtime for mission
critical installations by safely eliminating dangerous surges and spikes.
Extreme Voltage Shutdown (EVS) with auto reset safeguards against
operation during catastrophic under and over voltage conditions.
Linear Filtering Technology (LiFT) ensures maximum equipment perfor-
mance by reducing AC noise in a linear fashion across a wide bandwidth.
Remote Access (RS-232) compatibility with programming provides inte-
gration with various control system platforms, including BlueBOLT®.
Security features include a key switch to prevent unauthorized operation
and cover shields to prevent tampering with switch settings.
Forced Off immediate shutdown: for safety and fire ordinance compliance.
Multi-Color LED Indicators for status functions.
9 outlets on 4 banks providing 1800 total Watts of conditioned AC power.
10 ft. Power Cord 14 AWG
15 Year Limited Product Warranty
CN-1800S INST. REV. B 6-16-15
1
Introduction
Congratulations and thank you for choosing the Furman CN-1800S. We
assure you that your CN-1800S will provide many years of trouble free
operation. The CN-1800S is a 15 Amp Contractor-Grade Surge Protec-
tor and Power Sequencing device equipped with Furman’s exclusive
SmartSequencing™ technology. The Furman CN-1800S features mul-
tiple layers of protection that have been designed to shield your sensitive
analog and digital equipment from AC line hazards. Furman’s SmartSe-
quencing™ technology defines a new level of power management and
control while streamlining installations from start to finish.
Why choose Furman?
At Furman Sound, we have spent the last 30 years quietly obsessing
about professional audio and how to best separate your equipment from
the noise and damage often associated with AC power. Over the years we
have developed a multitude of technologies that have spared countless
devices from certain death and earned us the trust and respect of the
Professional A/V industry. The CN-1800S represents the culmination of
our engineering expertise and leverages more than 30 years of experi-
ence.
Why choose AC power sequencing?
Many pro audio/video installations need audio power amplifiers to activate
last. Our solution is the AC power sequencer. The power sequencer pro-
vides AC power to outlet groups one at a time, thus allowing equipment to
be powered up and down in an orderly fashion by first providing power to
signal processing equipment and then providing power to the amplifiers.
When shutting down the A/V system, a sequencer will turn off the system
in the reverse order, hence the amps will be turned off first, and then the
signal processing equipment will be turned off last.
This is necessary because, as most sound reinforcement professionals
know, the majority of equipment damage occurs when devices are either
powered up or powered down. Power sequencing allows equipment
to power up in sequence and prevent the dreaded “pop”. The “pop”
is a speaker pop associated with on off switching of signal processing
equipment while the audio power amplifiers are energized. If the signal
processing “pop” is amplified sufficiently, the result can damage speaker
components. Because it prevents this unwanted, and often costly, circum-
stance, AC power sequencing is extremely valuable.
Furman Contractor Series equipment also allows sound reinforcement
equipment to be remotely powered up or powered down over a large
distance, not just in the immediate vicinity of the operator. Additionally,
Maintained or Momentary mode contact switching allows the user great
flexibility when controlling the unit from a remote location. A remotely
mounted switch or control pad can be used to sequence equipment on
or off. In addition, Furman Contractor Series remote functions can be
initiated across a room, on-site, or off-site with RS-232 protocol or our
cloud-based BlueBOLT technology.
The CN-1800S SmartSequencer incorporates Furman’s revolutionary
Series Multi-Stage Protection (SMP) circuit with our acclaimed Linear
Filtering Technology (LiFT). In combination, these field tested technologies
comprise, without question, the world’s most advanced power condition-
ing and transient voltage surge suppression anywhere! And, in regards to
Professional A/V, the CN-1800S fulfills many power sequencing require-
ments that have not been easy to achieve in the past. Furman SmartSe-
quencing™ delivers right out of the box! Please review this manual
thoroughly to discover how the CN1800S with SmartSequencing™
delivers professional results.
Before You Begin Inspect Upon Receipt
The box should contain the following items: a Contractor Series Quick
Start Guide
PRIMARY LINK
SECONDARY LINK
ETHERNET
DELAY 1
DELAY 2
DELAY 3
POWER
PROTECTION OK
EXTREME VOLTAGE
UNSWITCHED
15 AMPS
PUSH TO RESET
ON
OFF
REMOTE
CN-SERIES UNIT
CN-1800S
Pair of Security Keys
Two Removable Cover Shields and Four Screws
3 Phoenix Type Connectors
(2 four pin, 1 five pin)
CN-1800S
Quick Start Guide
2
Table of Contents
Feature Descriptions_____________________________________________________________________________________________2 & 3
Important Safety Instructions__________________________________________________________________________________________ 3
Quick Start Diagrams____________________________________________________________________________________________ 4 & 5
SmartSequencing™ 101 ____________________________________________________________________________________________ 6
Front Panel Overview _________________________________________________________________________________ 6, 7, 8, 9, 10 & 11
Rear Panel Overview___________________________________________________________________________________________ 12 & 13
Setup and Troubleshooting__________________________________________________________________________________________ 13
RS-232 Installation and Command Set_________________________________________________________________________________ 14
BlueBOLT™_________________________________________________________________________________________________14
Specifications ___________________________________________________________________________________________________ 14
FCC Notice and Customer Service_____________________________________________________________________________________ 14
15 Year Limited Warranty___________________________________________________________________________________________ 14
SmartSequencing™
Furman SmartSequencing™ is a contractor-friendly technology that
makes AC power sequencing easy to employ by non-technical person-
nel. Multiple Furman Contactor Series units can be linked together using
inexpensive two conductor wire, thus creating a vast control system.
Generally, high-priced automation systems are used for large, innovative
installs, yet these control systems seldom combine AC power distribu-
tion, filtering, and protection. Furthermore, many automation systems are
difficult to implement on smaller budgets. SmartSequencing™ provides
the answer right out of the box by offering a simple approach to AC power
management and control. Furman’s newest power sequencing technology
is an end-to-end solution that is operational up to 1000 feet via a non-
polarized, isolated current loop. In situations where power sequencing is
critical, or more than one AC electrical circuit is utilized, wiring Furman
SmartSequencing™ products in series is simple, fast and reliable.
SMP (Series Multi-Stage Protection)
Furman’s SMP surge suppression virtually eliminates service calls and
costly “down time”. Traditional surge suppression circuits sacrifice
themselves when exposed to multiple transient voltage spikes, requiring
your system to be dismantled and your surge suppresser to be repaired.
This does not happen with Furman’s SMP. Damaging transient voltages
are safely absorbed, clamped, and dissipated. Your connected equipment
is protected, while your Furman protects itself! Its unparalleled clamp-
ing voltage is unique to Furman’s SMP. According to UL 1449 Clamping
Level is defined as the amount of voltage that is allowed to pass through
to your equipment when the protection device is subjected to a transient
surge or spike. While other designs offer clamping voltages that clamp
well above 330 Vpk, Furman’s SMP clamps at 188 Vpk, (133 VAC RMS)
even when tested with multiple 6000 Vpk - 3000 Amp surges. This
unprecedented level of protection is only available with Furman’s SMP
technology!
EVS (EXTREME VOLTAGE SHUTDOWN)
Furman’s trusted (EVS) over-voltage circuitry protects against prolonged
over-voltage conditions, such as accidental connections to 208 or 240
VAC or an intermittent loss of neutral. It does so by monitoring the incom-
ing AC voltage. When an unsafe condition is detected, a relay shuts off
the incoming power until the overvoltage condition has been corrected.
The CN-1800S augments the EVS capability with Auto Reset options
allowing the end user to decide if the power should be reinstated, or re-
main off until conditions return to acceptable limits. The Extreme Voltage
Shutdown technology is a tremendous asset.
LIFT (LINEAR FILTERING TECHNOLOGY)
Unfortunately, traditional AC power conditioners have been designed
under unrealistic laboratory conditions. Professional audio/video compo-
nents are constantly bombarded by electromagnetic interference (EMI)
and radio frequency interference (RFI) via their AC power source. Prior
technologies, whether they were multiple-pole or conventional series-
mode filters, could actually harm audio and video performance more than
they help, due to the resonant peaking of their antiquated, non-linear de-
signs. Under certain conditions, these designs can actually add more than
10 dB of noise to the incoming AC line! Worse still, AC noise and ground
contamination frequently causes system reboots, sync issues and even
data loss. LiFT takes a different approach, ensuring optimal performance
through Furman’s linear AC noise filtering with no ground contamination.
3
Remote Access (and BlueBOLT®)
If so desired, the CN-1800S can be controlled remotely via an integral
RS-232 data-link and command protocol. The remote access feature
delivers integration with various control systems. The protocol set
provides over a dozen commands such as reset, disable, and sequence
and includes queries such as voltage, current, and power. Our optional
BlueBOLT® RS-232-to-Ethernet adaptor (available Q4, 2012) provides
additional control programming and monitoring from any Web-enabled
device via Telnet, direct HTTP connection, or www.mybluebolt.com
Important Safety Instructions
1. Please read and follow all instructions.
2. Please keep these instructions.
3. Please heed all warnings.
4. WARNING: This device is intended for indoor use only. Do not use
this device near water. To Reduce the risk of fire or electric shock, do not
expose this device to rain or moisture.
5. CAUTION: Always On receptacles are present, providing constant
AC power. To Reduce risk of shock, please disconnect the CN-1800S /
CN-2400S Sequencer from AC power before servicing any equipment
connected to the CN-1800S / CN-2400S Sequencer.
6. Clean only with dry cloth.
7. CAUTION: Do not install near any heat sources such as radiators, heat
registers, stoves, or other equipment that may produce heat.
8. Protect the power cord from being walked on or pinched, particularly at
plugs, convenience receptacles, and the point where they exit the device.
9. WARNING: The DB-9 RS-232 communications port provides power for
Furman accessories (e.g. BB-RS232). Please verify pin assignment and
protocol before connecting any other manufacturer’s device to this port.
10. Please, only use accessories specified by the manufacturer.
11. Refer all servicing to qualified personnel. Servicing is required when
the unit has been damaged in anyway or fails to operate.
12. WARNING: Do not use power cord as the main power disconnect.
The device is intended for AC power sequencing.
13. Do not defeat the safety purpose of the polarized plug. A polarized
plug has two blades, with one wider than the other. The wide blade is
provided for your safety. If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete outlet.
14. Do not defeat the safety purpose of the grounding prong. A ground
type plug has two blades and a third grounding prong. The third prong is
provided for your safety. If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete outlet.
15. WARNING: This device must be connected to an AC outlet with a
protective earth ground connection.
Security and Safety
The CN1800S is adaptable to most common installation requests and
requirements. An ON/OFF key switch prevents operation from unau-
thorized personnel and removable security covers help to discourage
tampering. The RS-232 DE-9 communications port can be defeated by
the key switch. Furthermore, there are Forced Off inputs and selectable
DIP Switch settings for connecting to alarm systems, thus providing an
immediate power shutdown in compliance with many fire ordinances. The
combinations of features cover many needs for a wide variety of client
concerns.
Additional Features
The CN1800S Power Sequencer is equipped with eight 120V rear panel
outlets on four duplexes and a single front panel convenience outlet,
all filtered and protected with Furman technology. The unit has three
unswitched outlets that provide constant power under safe utility condi-
tions. Rear panel outlets are divided into four banks: one bank with two
unswitched outlets and three banks are sequenced at two outlets per
bank. A related dry contact is coupled with the “Delay Bank 3” bank; to-
gether both can offer a delay up to seven minutes. Features also include
10 LED indicators to aid in tracking conditions such as power, protection,
sequencing and communication. And naturally, the CN-1800S Contractor
Series 1800 Watt 15 Amp capacity is supplied by a robust 14 AWG, 10
foot AC cord.
All Contractor Series units and features are backed by a 15 year Limited
Warranty.
4
SmartSequencer
DIAGRAM 1
-
SMALL SMARTSEQUENCING SET-UP
CLASS 2 WIRING
24 AWG RECOMMENDED
Fire ordinances sometime require immediate shut
down, no matter how large or small a sound system.
SmartSequencing provides the solution.
RS-2 Momentary
Remote Switch
CN-1800S
+12
STAT
REM
GND
+12
STAT
REM
GND
P
S
FIRE ALARM (2 POLE)
V S R G D
P S
FORCE OFF
V S R G D
P S
FRONT PANEL DIP SWITCH SET
POWERED ARRAYS
MONITOR SYSTEM
BACK PANEL TERMINALS
CN-20 MP
CN-20 MP
FORCE
OFF
NO
NC
C
FORCE OFF
DELAY
ADJUST
IMMEDIATE FORCED OFF WITH SHORT
V = VOLTAGE
S = STATUS
R = REMOTE
G = GROUND
D = DELAY
ON
1 2 3 4 5 6 7 8 9
ON
1 2 3 4 5 6 7 8 9
DIP SWITCH SET
DIP SWITCH SET
ON
1 2 3 4 5 6 7 8 9
1M
1 2 3 4 5
2M
4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
1 2 3 4 5 6 7 8 9
ON
FOR REFERENCE
ONLY
ABBREVIATED
DESCRIPTIONS
AS SHOWN ON
THE PRODUCT.
NOT FOR
SETTING(S)
INSTRUCTIONS.
CN-1800S
+12
STAT
REM
GND
P
S
BACK PANEL TERMINALS
FORCE
OFF
NO
NC
C
DELAY
ADJUST
CN-1800 replaces Legacy product for
purposes of immediate shutdown.
RS-1 Maintained
Key Switch
+12
STAT
REM
GND
FIRE ALARM (3 POLE)
V S R G D
NC C NO
MP-15
SUB
MP-15
MAIN
V S R G D
V S R G D
MP-15
SUB
V S R G D
MP-15
MAIN
SmartSequencer
DIAGRAM 2
-
SMALL LEGACY SET-UP
ON
1 2 3 4 5 6 7 8 9
DIP SWITCH SET
CLASS 2 WIRING
24 AWG RECOMMENDED
1M
1 2 3 4 5
2M
4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
1 2 3 4 5 6 7 8 9
ON
FOR REFERENCE
ONLY
ABBREVIATED
DESCRIPTIONS
AS SHOWN ON
THE PRODUCT.
NOT FOR
SETTING(S)
INSTRUCTIONS.
EXAMPLE 1 DIAGRAM - SMALL SmartSequencing SET-UP
EXAMPLE 2 DIAGRAM - SMALL LEGACY SET-UP
Loading...
+ 11 hidden pages