Furman CN-1800S Users Manual

CONTRACTOR SERIES SmartSequencer
CN-1800S
Instructions
PRIMARY LINK
SECONDARY LINK
ETHERNET
15 AMPS
REMOTE
ON
OFF
DELAY 1
DELAY 2
DELAY 3
PROTECTION OK
EXTREME VOLTAGE
UNSWITCHED
PUSH TO RESET
CN-1800S
Contractor Grade Power Management with SmartSequencing™
Features:
SmartSequencing™ technology allows large complex A/V systems to be
safely power cycled on and off sequentially, with a simple key turn or press of a button.
Series Multi-Stage Protection (SMP) ensures zero downtime for mission critical installations by safely eliminating dangerous surges and spikes.
Extreme Voltage Shutdown (EVS) with auto reset safeguards against operation during catastrophic under and over voltage conditions.
Linear Filtering Technology (LiFT) ensures maximum equipment perfor­mance by reducing AC noise in a linear fashion across a wide bandwidth.
Remote Access (RS-232) compatibility with programming provides inte­gration with various control system platforms, including BlueBOLT®.
Security features include a key switch to prevent unauthorized operation and cover shields to prevent tampering with switch settings.
Forced Off immediate shutdown: for safety and fire ordinance compliance. Multi-Color LED Indicators for status functions.
9 outlets on 4 banks providing 1800 total Watts of conditioned AC power.
10 ft. Power Cord 14 AWG
15 Year Limited Product Warranty
CN-1800S INST. REV. B 6-16-15
Introduction
PRIMARY LINK
SECONDARY LINK
ETHERNET
DELAY 1
DELAY 2
DELAY 3
POWER
PROTECTION OK
EXTREME VOLTAGE
UNSWITCHED
15 AMPS
PUSH TO RESET
ON
OFF
REMOTE
Congratulations and thank you for choosing the Furman CN-1800S. We assure you that your CN-1800S will provide many years of trouble free operation. The CN-1800S is a 15 Amp Contractor-Grade Surge Protec­tor and Power Sequencing device equipped with Furman’s exclusive SmartSequencing™ technology. The Furman CN-1800S features mul­tiple layers of protection that have been designed to shield your sensitive analog and digital equipment from AC line hazards. Furman’s SmartSe­quencing™ technology defines a new level of power management and control while streamlining installations from start to finish.
Why choose Furman?
At Furman Sound, we have spent the last 30 years quietly obsessing about professional audio and how to best separate your equipment from the noise and damage often associated with AC power. Over the years we have developed a multitude of technologies that have spared countless devices from certain death and earned us the trust and respect of the Professional A/V industry. The CN-1800S represents the culmination of our engineering expertise and leverages more than 30 years of experi­ence.
The CN-1800S SmartSequencer incorporates Furman’s revolutionary Series Multi-Stage Protection (SMP) circuit with our acclaimed Linear Filtering Technology (LiFT). In combination, these field tested technologies comprise, without question, the world’s most advanced power condition­ing and transient voltage surge suppression anywhere! And, in regards to Professional A/V, the CN-1800S fulfills many power sequencing require­ments that have not been easy to achieve in the past. Furman SmartSe­quencing™ delivers right out of the box! Please review this manual thoroughly to discover how the CN1800S with SmartSequencing™ delivers professional results.
Before You Begin Inspect Upon Receipt
The box should contain the following items: a Contractor Series Quick Start Guide
CN-SERIES UNIT
CN-1800S
Why choose AC power sequencing?
Many pro audio/video installations need audio power amplifiers to activate last. Our solution is the AC power sequencer. The power sequencer pro­vides AC power to outlet groups one at a time, thus allowing equipment to be powered up and down in an orderly fashion by first providing power to signal processing equipment and then providing power to the amplifiers. When shutting down the A/V system, a sequencer will turn off the system in the reverse order, hence the amps will be turned off first, and then the signal processing equipment will be turned off last.
This is necessary because, as most sound reinforcement professionals know, the majority of equipment damage occurs when devices are either powered up or powered down. Power sequencing allows equipment to power up in sequence and prevent the dreaded “pop”. The “pop” is a speaker pop associated with on off switching of signal processing equipment while the audio power amplifiers are energized. If the signal processing “pop” is amplified sufficiently, the result can damage speaker components. Because it prevents this unwanted, and often costly, circum­stance, AC power sequencing is extremely valuable.
Furman Contractor Series equipment also allows sound reinforcement equipment to be remotely powered up or powered down over a large distance, not just in the immediate vicinity of the operator. Additionally, Maintained or Momentary mode contact switching allows the user great flexibility when controlling the unit from a remote location. A remotely mounted switch or control pad can be used to sequence equipment on or off. In addition, Furman Contractor Series remote functions can be initiated across a room, on-site, or off-site with RS-232 protocol or our cloud-based BlueBOLT technology.
CN-1800S
Pair of Security Keys
3 Phoenix Type Connectors (2 four pin, 1 five pin)
Two Removable Cover Shields and Four Screws
Quick Start Guide
1
Table of Contents
Feature Descriptions_____________________________________________________________________________________________2 & 3
Important Safety Instructions__________________________________________________________________________________________ 3
Quick Start Diagrams____________________________________________________________________________________________ 4 & 5
SmartSequencing™ 101 ____________________________________________________________________________________________ 6
Front Panel Overview _________________________________________________________________________________ 6, 7, 8, 9, 10 & 11
Rear Panel Overview___________________________________________________________________________________________ 12 & 13
Setup and Troubleshooting__________________________________________________________________________________________ 13
RS-232 Installation and Command Set_________________________________________________________________________________ 14
BlueBOLT™_________________________________________________________________________________________________14
Specifications ___________________________________________________________________________________________________ 14
FCC Notice and Customer Service_____________________________________________________________________________________ 14
15 Year Limited Warranty___________________________________________________________________________________________ 14
SmartSequencing™
Furman SmartSequencing™ is a contractor-friendly technology that makes AC power sequencing easy to employ by non-technical person­nel. Multiple Furman Contactor Series units can be linked together using inexpensive two conductor wire, thus creating a vast control system. Generally, high-priced automation systems are used for large, innovative installs, yet these control systems seldom combine AC power distribu­tion, filtering, and protection. Furthermore, many automation systems are difficult to implement on smaller budgets. SmartSequencing™ provides the answer right out of the box by offering a simple approach to AC power management and control. Furman’s newest power sequencing technology is an end-to-end solution that is operational up to 1000 feet via a non­polarized, isolated current loop. In situations where power sequencing is critical, or more than one AC electrical circuit is utilized, wiring Furman SmartSequencing™ products in series is simple, fast and reliable.
SMP (Series Multi-Stage Protection)
Furman’s SMP surge suppression virtually eliminates service calls and costly “down time”. Traditional surge suppression circuits sacrifice themselves when exposed to multiple transient voltage spikes, requiring your system to be dismantled and your surge suppresser to be repaired. This does not happen with Furman’s SMP. Damaging transient voltages are safely absorbed, clamped, and dissipated. Your connected equipment is protected, while your Furman protects itself! Its unparalleled clamp­ing voltage is unique to Furman’s SMP. According to UL 1449 Clamping Level is defined as the amount of voltage that is allowed to pass through to your equipment when the protection device is subjected to a transient surge or spike. While other designs offer clamping voltages that clamp well above 330 Vpk, Furman’s SMP clamps at 188 Vpk, (133 VAC RMS) even when tested with multiple 6000 Vpk - 3000 Amp surges. This unprecedented level of protection is only available with Furman’s SMP technology!
EVS (EXTREME VOLTAGE SHUTDOWN)
Furman’s trusted (EVS) over-voltage circuitry protects against prolonged over-voltage conditions, such as accidental connections to 208 or 240 VAC or an intermittent loss of neutral. It does so by monitoring the incom­ing AC voltage. When an unsafe condition is detected, a relay shuts off the incoming power until the overvoltage condition has been corrected. The CN-1800S augments the EVS capability with Auto Reset options allowing the end user to decide if the power should be reinstated, or re­main off until conditions return to acceptable limits. The Extreme Voltage Shutdown technology is a tremendous asset.
LIFT (LINEAR FILTERING TECHNOLOGY)
Unfortunately, traditional AC power conditioners have been designed under unrealistic laboratory conditions. Professional audio/video compo­nents are constantly bombarded by electromagnetic interference (EMI) and radio frequency interference (RFI) via their AC power source. Prior technologies, whether they were multiple-pole or conventional series­mode filters, could actually harm audio and video performance more than they help, due to the resonant peaking of their antiquated, non-linear de­signs. Under certain conditions, these designs can actually add more than 10 dB of noise to the incoming AC line! Worse still, AC noise and ground contamination frequently causes system reboots, sync issues and even data loss. LiFT takes a different approach, ensuring optimal performance through Furman’s linear AC noise filtering with no ground contamination.
2
Remote Access (and BlueBOLT®)
Important Safety Instructions
If so desired, the CN-1800S can be controlled remotely via an integral RS-232 data-link and command protocol. The remote access feature delivers integration with various control systems. The protocol set provides over a dozen commands such as reset, disable, and sequence and includes queries such as voltage, current, and power. Our optional BlueBOLT® RS-232-to-Ethernet adaptor (available Q4, 2012) provides additional control programming and monitoring from any Web-enabled device via Telnet, direct HTTP connection, or www.mybluebolt.com
Security and Safety
1. Please read and follow all instructions.
2. Please keep these instructions.
3. Please heed all warnings.
4. WARNING: This device is intended for indoor use only. Do not use
this device near water. To Reduce the risk of fire or electric shock, do not expose this device to rain or moisture.
5. CAUTION: Always On receptacles are present, providing constant AC power. To Reduce risk of shock, please disconnect the CN-1800S / CN-2400S Sequencer from AC power before servicing any equipment connected to the CN-1800S / CN-2400S Sequencer.
6. Clean only with dry cloth.
7. CAUTION: Do not install near any heat sources such as radiators, heat
registers, stoves, or other equipment that may produce heat.
8. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit the device.
9. WARNING: The DB-9 RS-232 communications port provides power for Furman accessories (e.g. BB-RS232). Please verify pin assignment and protocol before connecting any other manufacturer’s device to this port.
The CN1800S is adaptable to most common installation requests and requirements. An ON/OFF key switch prevents operation from unau­thorized personnel and removable security covers help to discourage tampering. The RS-232 DE-9 communications port can be defeated by the key switch. Furthermore, there are Forced Off inputs and selectable DIP Switch settings for connecting to alarm systems, thus providing an immediate power shutdown in compliance with many fire ordinances. The combinations of features cover many needs for a wide variety of client concerns.
Additional Features
The CN1800S Power Sequencer is equipped with eight 120V rear panel outlets on four duplexes and a single front panel convenience outlet, all filtered and protected with Furman technology. The unit has three unswitched outlets that provide constant power under safe utility condi­tions. Rear panel outlets are divided into four banks: one bank with two unswitched outlets and three banks are sequenced at two outlets per bank. A related dry contact is coupled with the “Delay Bank 3” bank; to­gether both can offer a delay up to seven minutes. Features also include 10 LED indicators to aid in tracking conditions such as power, protection, sequencing and communication. And naturally, the CN-1800S Contractor Series 1800 Watt 15 Amp capacity is supplied by a robust 14 AWG, 10 foot AC cord.
10. Please, only use accessories specified by the manufacturer.
11. Refer all servicing to qualified personnel. Servicing is required when
the unit has been damaged in anyway or fails to operate.
12. WARNING: Do not use power cord as the main power disconnect. The device is intended for AC power sequencing.
13. Do not defeat the safety purpose of the polarized plug. A polarized plug has two blades, with one wider than the other. The wide blade is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
14. Do not defeat the safety purpose of the grounding prong. A ground type plug has two blades and a third grounding prong. The third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
15. WARNING: This device must be connected to an AC outlet with a protective earth ground connection.
All Contractor Series units and features are backed by a 15 year Limited Warranty.
3
SmartSequencer
DIAGRAM 1
-
SMALL SMARTSEQUENCING SET-UP
CLASS 2 WIRING
24 AWG RECOMMENDED
Fire ordinances sometime require immediate shut down, no matter how large or small a sound system. SmartSequencing provides the solution.
RS-2 Momentary Remote Switch
CN-1800S
+12
STAT
REM GND
+12 STAT REM GND
P
S
FIRE ALARM (2 POLE)
V S R G D
P S
FORCE OFF
V S R G D
P S
FRONT PANEL DIP SWITCH SET
POWERED ARRAYS
MONITOR SYSTEM
BACK PANEL TERMINALS
CN-20 MP
CN-20 MP
FORCE
OFF
NO NC
C
FORCE OFF
DELAY
ADJUST
IMMEDIATE FORCED OFF WITH SHORT
V = VOLTAGE S = STATUS R = REMOTE G = GROUND D = DELAY
ON
1 2 3 4 5 6 7 8 9
ON
1 2 3 4 5 6 7 8 9
DIP SWITCH SET
DIP SWITCH SET
ON
1 2 3 4 5 6 7 8 9
1M
1 2 3 4 5
2M
4M
N.O. N.C.
12V ON 12V OFF
GND
ON
MOM MNT
PRI SEC
EVS AUTO
MANUAL
6 7 8 9
1 2 3 4 5 6 7 8 9
ON
FOR REFERENCE ONLY
ABBREVIATED DESCRIPTIONS AS SHOWN ON THE PRODUCT. NOT FOR SETTING(S) INSTRUCTIONS.
CN-1800S
+12 STAT REM GND
P
S
BACK PANEL TERMINALS
FORCE
OFF
NO NC
C
DELAY
ADJUST
CN-1800 replaces Legacy product for purposes of immediate shutdown.
RS-1 Maintained Key Switch
+12
STAT
REM GND
FIRE ALARM (3 POLE)
V S R G D
NC C NO
MP-15
SUB
MP-15
MAIN
V S R G D
V S R G D
MP-15
SUB
V S R G D
MP-15
MAIN
SmartSequencer
DIAGRAM 2
-
SMALL LEGACY SET-UP
ON
1 2 3 4 5 6 7 8 9
DIP SWITCH SET
CLASS 2 WIRING
24 AWG RECOMMENDED
1M
1 2 3 4 5
2M
4M
N.O. N.C.
12V ON 12V OFF
GND
ON
MOM MNT
PRI SEC
EVS AUTO
MANUAL
6 7 8 9
1 2 3 4 5 6 7 8 9
ON
FOR REFERENCE ONLY
ABBREVIATED DESCRIPTIONS AS SHOWN ON THE PRODUCT. NOT FOR SETTING(S) INSTRUCTIONS.
EXAMPLE 1 DIAGRAM - SMALL SmartSequencing SET-UP
EXAMPLE 2 DIAGRAM - SMALL LEGACY SET-UP
4
Loading...
+ 11 hidden pages