Furman CN-15MP Data Sheet

CN-15MP & CN-20MP
Contractor Series MiniPorts
Features
• Provides AC control for equipment located away from system racks with primary power conditioners/ sequencers (i.e. powered speakers).
• Sequencing of duplex initiated remotely by standard analog triggering (remote terminal) or digital link (SmartSequencing from CN-1800S or CN-2400S).
• IP Control (Telnet or cloud-based BlueBOLT) via SmartSequencing (when connected to CN-1800S/ CN-2400S with BB-RS232 Adaptor.
CN-15MP
(shown without Phoenix-type connectors and security cover)
• Remote terminal supports connections to legacy Furman (non-Contractor Series) and third party power sequencers for maximum installation flexibility.
• DIP switches and potentiometer allows customiza­tion of settings such as sequencing delays, 12V on/ off, and more.
• Extreme Voltage Shutdown (EVS) safeguards from catastrophic under-voltage (under 80V sustained) or over-voltage (over 145V sustained) conditions. Circuit may be set to auto-reset when voltage returns to normal or manual reset after an event is detected.
• Security covers prevent unauthorized personnel from tampering with DIP switches.
Force Off Phoenix-type 2-pin connector with screw terminals
SmartSequencer Port Phoenix-type 4-pin connector with screw terminals
Primary/Secondary Link Indicators
CN-20MP
(shown with Phoenix-type connectors and security cover)
• Fire alarm shut off.
• Available with 15 amp capacity (CN-15MP) or 20 amp capacity (CN-20MP).
• Safety agency listed (CSA).
• 15 Year Limited Product Warranty.
See warranty policy documentation for terms and conditions.
15 YEAR
15 YEAR
PRODUCT WARRANTY
PRODUCT WARRANTY
See actual warranty documentation for details.
Remote Port Phoenix-type 5-pin connector with screw terminals
AC Receptacles: CN-15MP (Shown) NEMA-15R
CN-20MP NEMA-20R 20A
®
Potentiometer for Fine Tune Delay Time
DIP switches for configuring settings
Bypass switch overrides relay for troubleshooting or in event of control system failure
www.furmancontractor.com 800-472-5555
Extreme Voltage/ Power Indicators
Circuit Breaker: 15A CN-15MP CN-20MP No Circuit Breaker
10 ft. AC power cord AC cord with strain relief CN-15MP: NEMA-15P
CN-20MP: NEMA-20P
BYPASS
1M
2M
4M
N.O.
N.C.
12V ON
12V OFF
1
2
3 4
5
GND
ON
MOM
MNT
PRI
SEC
EVS ON
EVS OFF
6
7
8
9
DLY
ADJ
C US
Specifications
AC Voltage Input Range 90-139VAC, 50/60Hz Maximum AC Current Rating CN-15MP: 15 Amps (Thermal breaker) CN-20MP: 20 Amps
AC Cord:
CN-15MP: 3/14AWG, 10 feet, black, fixed, NEMA 5-15P plug CN-20MP: 3/12 AWG, 10 feet, black, fixed, NEMA 5-20P plug
AC Receptacles:
CN-15MP: 2 NEMA 5-15R’s (1 duplex) CN-20MP: 2 NEMA 5-20R’s (1 duplex)
Under-Overvoltage Protection:
AC Undervoltage Protection: EVS, 77VAC+/-3VAC AC Overvoltage Protection: EVS, 140VAC+/-5VAC EVS Enable/Disable (configurable)
Operating Temperature Range: 5C (40F) to 40C (105F) degrees Humidity Range: <90% rH (Relative Humidity) User Interface:
Circuit Breaker: Pushbutton, 15A (CN-15MP), 20A (CN-20MP) No Breaker Front panel diagnostic indicators (LED): Power, Extreme Voltage, Primary Link, Secondary Link
Specifications subject to change due to product upgrades and improvements.
Dimensions and Weight
User Interface (continued): Side Panel DIP Switches: Side panel. hidden by security cover, 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off GND Mode On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual Potentiometer: Side panel, hidden by security cover, fine tune delay adjust
Control/Status/Triggering (Top Panel):
Remote Terminal: +5-30VDC In, 12VDC (12mA) Out SmartSequencing: Phoenix-type 4-Pin Connector, Screw Terminals, Primary & Secondary Links (Current Loop - 1000’ nominal) Remote Terminal: Phoenix-type 5-Pin Connector With Screw Terminals; +12V, STAT, REM, GND, DLY OUT(Class 2 Wiring) Force Off: Phoenix-type 2-Pin Connector With Screw Terminals, FORCE OFF: (Class 2 Wiring) IP Addressability: Optional, via CN-1800S or CN-2400S with BB-RS232 Ethernet/RS-232 Adaptor (sold separately) for IP control via Telnet, HTTP, BlueBOLT® Voltmeter: Available via SmartSequencing communication, +/- 2VAC accuracy Ammeter: Available via SmartSequencing communication, +/-1A accuracy
Power Consumption (No Load): 10 Watts Safety Agency: CSA RoHS Compliant: Yes
C US
7.375 in.
Common FRONT dimensions for both CN-15MP and CN-20MP
6.25 in.
4.75 in.
FORCE
OFF
REMOTE
PORT
POWER
120 VAC, 50/60 Hz MAX LOAD 15A
+12V
STAT
REM
GND
DLY OUT
C US
SMARTSEQUENCING
OUT
PRIMARY
LINK
SECONDARY
LINK
IN
EXTREME VOLTAGE
MINIPORT
P
P
S
S
15 AMP
CLASS 2 WIRING
CN-15MP
6.5 in.
SIDE CN-15MP SIDE CN-20MP
Allow 1 extra inch for connectors Allow 1 extra inch for connectors
2 in.
BYPASS
C US
2.5 in.
BYPASS
C US
5.5 in.
Unit Weight: 3.75 lbs. (both models)
www.furmancontractor.com 800-472-5555
Power Cord-10 feet, black, fixed, NEMA
• (CN-15MP) 3/14AWG, 5-15P plug
Power Cord-10 feet, black, fixed, NEMA
• (CN-20MP) 3/12AWG, 5-20P plug
CN-15-20-MP 9-12