![](/html/19/19b1/19b1dde77711fdc9fd4cd02d62d383aafc28519f91df97e5af57f68e7b330d7a/bg1.png)
CN-15MP & CN-20MP
Contractor Series MiniPorts
Features
• Provides AC control for equipment located away
from system racks with primary power conditioners/
sequencers (i.e. powered speakers).
• Sequencing of duplex initiated remotely by standard
analog triggering (remote terminal) or digital link
(SmartSequencing from CN-1800S or CN-2400S).
• SmartSequencing Technology allows multiple units
to be daisy chained at runs of over 1,000’ between
units with bi-directional communications between
units for sequencing on and off large and/or complex
systems.
• IP Control (Telnet or cloud-based BlueBOLT) via
SmartSequencing (when connected to CN-1800S/
CN-2400S with BB-RS232 Adaptor.
CN-15MP
(shown without
Phoenix-type
connectors and
security cover)
• Remote terminal supports connections to legacy
Furman (non-Contractor Series) and third party power
sequencers for maximum installation flexibility.
• DIP switches and potentiometer allows customization of settings such as sequencing delays, 12V on/
off, and more.
• Extreme Voltage Shutdown (EVS) safeguards from
catastrophic under-voltage (under 80V sustained) or
over-voltage (over 145V sustained) conditions. Circuit
may be set to auto-reset when voltage returns to
normal or manual reset after an event is detected.
• Security covers prevent unauthorized personnel
from tampering with DIP switches.
Force Off Phoenix-type
2-pin connector with
screw terminals
SmartSequencer Port
Phoenix-type 4-pin
connector with
screw terminals
Primary/Secondary
Link Indicators
CN-20MP
(shown with
Phoenix-type
connectors and
security cover)
• Fire alarm shut off.
• Available with 15 amp capacity (CN-15MP) or
20 amp capacity (CN-20MP).
• Safety agency listed (CSA).
• 15 Year Limited Product Warranty.
See warranty policy documentation for terms and conditions.
15 YEAR
15 YEAR
PRODUCT WARRANTY
PRODUCT WARRANTY
See actual warranty documentation for details.
Remote Port Phoenix-type 5-pin
connector with screw terminals
AC Receptacles:
CN-15MP (Shown)
NEMA-15R
CN-20MP
NEMA-20R 20A
®
Potentiometer for Fine
Tune Delay Time
DIP switches for
configuring settings
Bypass switch
overrides relay for
troubleshooting or
in event of control
system failure
www.furmancontractor.com 800-472-5555
Extreme Voltage/
Power Indicators
Circuit Breaker:
15A CN-15MP
CN-20MP No Circuit Breaker
10 ft. AC power cord AC cord with strain relief CN-15MP: NEMA-15P
CN-20MP: NEMA-20P
![](/html/19/19b1/19b1dde77711fdc9fd4cd02d62d383aafc28519f91df97e5af57f68e7b330d7a/bg2.png)
BYPASS
1M
2M
4M
N.O.
N.C.
12V ON
12V OFF
1
2
3 4
5
GND
ON
MOM
MNT
PRI
SEC
EVS ON
EVS OFF
6
7
8
9
DLY
ADJ
C US
Specifications
AC Voltage Input Range
90-139VAC, 50/60Hz
Maximum AC Current Rating
CN-15MP: 15 Amps (Thermal breaker)
CN-20MP: 20 Amps
AC Cord:
CN-15MP: 3/14AWG, 10 feet, black, fixed, NEMA 5-15P plug
CN-20MP: 3/12 AWG, 10 feet, black, fixed, NEMA 5-20P plug
AC Receptacles:
CN-15MP: 2 NEMA 5-15R’s (1 duplex)
CN-20MP: 2 NEMA 5-20R’s (1 duplex)
Under-Overvoltage Protection:
AC Undervoltage Protection: EVS, 77VAC+/-3VAC
AC Overvoltage Protection: EVS, 140VAC+/-5VAC
EVS Enable/Disable (configurable)
Operating Temperature Range:
5C (40F) to 40C (105F) degrees
Humidity Range:
<90% rH (Relative Humidity)
User Interface:
Circuit Breaker: Pushbutton, 15A (CN-15MP),
20A (CN-20MP) No Breaker
Front panel diagnostic indicators (LED): Power, Extreme Voltage, Primary
Link, Secondary Link
Specifications subject to change due to product upgrades and improvements.
Dimensions and Weight
User Interface (continued):
Side Panel DIP Switches: Side panel. hidden by security cover, 1 Minute Delay,
2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off GND Mode
On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual
Potentiometer: Side panel, hidden by security cover, fine tune delay adjust
Control/Status/Triggering (Top Panel):
Remote Terminal: +5-30VDC In, 12VDC (12mA) Out
SmartSequencing: Phoenix-type 4-Pin Connector, Screw Terminals,
Primary & Secondary Links (Current Loop - 1000’ nominal)
Remote Terminal: Phoenix-type 5-Pin Connector With Screw Terminals;
+12V, STAT, REM, GND, DLY OUT(Class 2 Wiring)
Force Off: Phoenix-type 2-Pin Connector With Screw Terminals,
FORCE OFF: (Class 2 Wiring)
IP Addressability: Optional, via CN-1800S or CN-2400S with BB-RS232
Ethernet/RS-232
Adaptor (sold separately) for IP control via Telnet, HTTP, BlueBOLT®
Voltmeter: Available via SmartSequencing communication, +/- 2VAC accuracy
Ammeter: Available via SmartSequencing communication, +/-1A accuracy
Power Consumption (No Load): 10 Watts
Safety Agency: CSA
RoHS Compliant: Yes
C US
7.375 in.
Common FRONT dimensions for both CN-15MP and CN-20MP
6.25 in.
4.75 in.
FORCE
OFF
REMOTE
PORT
POWER
120 VAC, 50/60 Hz
MAX LOAD 15A
+12V
STAT
REM
GND
DLY OUT
C US
SMARTSEQUENCING
OUT
PRIMARY
LINK
SECONDARY
LINK
IN
EXTREME VOLTAGE
MINIPORT
P
P
S
S
15 AMP
CLASS 2 WIRING
CN-15MP
6.5 in.
SIDE CN-15MP SIDE CN-20MP
Allow 1 extra inch for connectors Allow 1 extra inch for connectors
2 in.
BYPASS
C US
2.5 in.
BYPASS
C US
5.5 in.
Unit Weight: 3.75 lbs. (both models)
www.furmancontractor.com 800-472-5555
Power Cord-10 feet, black, fixed, NEMA
• (CN-15MP) 3/14AWG, 5-15P plug
Power Cord-10 feet, black, fixed, NEMA
• (CN-20MP) 3/12AWG, 5-20P plug
CN-15-20-MP 9-12