Furman ASD-120 2.0 Datasheet

20 A
12
ON
REMOTE
ASD-120 2.0
6 CHANNEL SEQUENCING POWER DISTRIBUTOR
The ASD-120 2.0 is a six channel power sequencing device intended for use in installations where multiple electrical loads must be powered on and off in a delayed
and orderly sequence. Typical applications for the ASD-120 2.0 include: touring PA or sound reinforcement systems, musical or theatrical acts, mobile recording facilities,
and on-location film or video shoots. Essentially, any situation where AC power must be distributed to multiple circuits and activated or deactivated in discrete stages
would benefit from the use of an ASD-120 2.0.
Applications for:
PRO AUDIO
RECORDING
DJ EQUIPMENT
INSTRUMENT RIGS
PRODUCT FEATURES
• 120 amp 120 volt AC sequenced distro and controller
• Six Independent 20 amp circuits @ 120V - 120 amp total load capacity
• Six delay banks with rear panel NEMA 5-20R duplex outlets and optically isolated DC relay outlets
• Front panel status power LED, Bypass Switch and Circuit Breaker for each Delay Bank
• 120A power distribution block accommodates 120V/240V single phase, or 120/208-Y three phase power
• X Y Z Status LED confidence indicators for each Input Phase
• Sequence unit ON or OFF from front panel or by remote switch
Relays
12 Total AC Outlets Six 20A Distribution
Circuits
• Independent three position switches to power sequence (SEQ) or Bypassed ON or OFF each Bank
• Adjustable Delay with up to 7 Minute Interval between Banks, Total maximum Sequence Time 35 minutes
• Remote interface with an isolated 12VDC, 250mA power source for external secondary applications
• Signal level relay contacts (NO or NC) used to control and sequence other units
• Front panel key switch and anti-tamper DIP cover for added security
• Force Off emergency shutdown
• Rugged two rack space (2RU) chassis
REMOTE
ON
Indicator Lights
Power Sequencing
Security Keyswitch6 Bank External
Please Note: Because the ASD-120 2.0 switches hazardous voltages and high currents, we recommend that the installation be performed by a qualified electrician. For safe operation,
the ASD-120 2.0 must be installed in accordance with local/municipal requirements and the National Electrical Code (NEC). Please feel free to contact Furman Technical Services if you have any questions or concerns regarding the installation, operation or application of the ASD-120 2.0.
www.furmansound.com 800-472-5555
FRONT and BACK PANEL FEATURES
Indicator LEDs for Delay A, B and C
Multi-function DIP Switch 7 Position ON/OFF
Security Cover to Protect Program Settings
Sequence Bypass Switch 6 Position ON/SEQUENCE/
Indicator LEDs for Delay D, E and F
Front Panel Key Switch for Remote Security
Front Panel Start Sequence Switch
Integrated Front Panel Rack Ears
Adjustable Rack Ears to Securely Connect to the Back of Rack. Maximum reach
20.75 in.
Circuit Breakers 20A for Delay A, B and C
AC Power Inlet 1.5 Inch Cable/Cord Clamp
Delay Adjustment
Indicator LEDs for Phases X, Y and Z
Six 20A Duplex Outlets
SPECIFICATIONS
AC Input Voltage
120/240V single phase, or 120/208V three phase.
Input Current: 120 Amps maximum
Output: Six, 120V 20A circuits
Maximum AC Current Rating
Six, 120V 20A circuits for 120A total.
Power Distribution Block
Wire Gauge 2, 3, 4-6 AWG,
Phase indicators: 3 LEDs, one per phase X, Y, and Z
AC Output Receptacles
Rear Panel Outlets: 6 duplex NEMA 5-20R sequenced.
Front Panel: 6 thermal circuit breakers, one per
duplex pair.
Operating Temperature and Humidity
5 to 40C (40 to 105F), <90% Relative Humidity
Specifications are subject to change without notice due to design improvements and upgrades.
User Interface
Key-switch: Front panel, 3 position (On/Off/Remote)
Keys: Included, 1 pair
Push Button Switch: Front panel
Circuit Breakers: Front panel, push-button; 6, 20A Thermal Breakers
Output Circuit Status: Front panel indicators – one per output
Configuration Switches: Front panel, hidden by security cover;
3 maximum delay switches – 1, 2, and 4 minute
Force Off NO/NC, 12V mode On/Off, GND mode ON,
Momentary/Maintained mode selection
Fine Delay Adjustment: Potentiometer hidden by security cover.
Sequence Bypass : 6 Switches, 3 States (ON/SEQUENCE/OFF)
Phase indicators: 3 LEDs, one per phase X, Y, and Z
Circuit Breakers 20A for
Delay D, E and FOFF
Force Off, 2 Pin Phoenix-type Connector
Delay Outputs, 8 Pin Phoenix-type Connector
Remote, 4 Pin Phoenix-type Connector
Control/Status/Triggering (Rear Panel)
Remote Terminal: Phoenix-type 4 Pin Connector w/Screw Terminals;
+12V @ 250mA, STAT, REM, GND (Class 2 wiring)
+5 to 30VDC at REM input terminal.
Delay Outputs: Phoenix-type 8-Pin Connector with Screw Terminals
6 relay contacts with NO and NC common connections
(Class 2 wiring)
A, B, C, D, E, and F relay contacts switched with output circuits, 1A@48VDC
Force Off: Phoenix-type 2 Pin Connector with Screw Terminals;
Optically isolated, 12V, 10mA current source
(Class 2 wiring)
Senses external relay contact closure
Power Consumption
Standby: 5 Watts
Sequenced ON: 20 Watts
Safety Agency
NTRL-C, RoHS Compliant
Removable Front Panel Handles
Weights, Dimensions anD UPC CoDes
Model PRodUCT diMensions WeighT CARTon diMensions WeighT single UniT UPC MAsTeR PACk QTy MAsTeR PACk UPC
ASD-120 2.0 19” L x 10” D x 3.5” H 16 lbs. 22”L x 18.5”D x 8”H 18 lbs. 654061041191 2 50654061041196
www.furmansound.com
Furman 1800 S. McDowell Blvd., Petaluma, CA 94954
Furman is registered trademark of Core Brands LLC, a Nortek Company.
©2016 Core Brands, LLC. All rights reserved.
ASD-120 12-30-15