Furman AC-215A Users Manual

OWNER’S MANUAL
AC-215 A
COMPACT POWER CONDITIONER
AC-215A
AC-215A MANUAL DEL PROPIETARIO
GUIDE DE L’UTILISATEUR
AC-215A
OWNER’S MANUAL
ENGLISH
Page 4
AC-215A
Page 14
GUIDE DE L’UTILISATEUR
AC-215A MANUAL DEL PROPIETARIO
ESPAÑOL
Page 24
ALL CONTENT ©2 009 FURMAN. AL L RIGHTS RESERVE D. PRINTED IN CHI NA.
FURMAN’S AC-215A FEATURES
SMP• (Series Multi-Stage Protection) with EVS (Extreme Voltage Shutdown) LiFT• (Linear Filtering Technology) with zero ground contamination
Compact chassis design easily attaches to any at screen television
mount (Includes hardware)
INTRODUCTION
Thank you for purchasing a Furman AC-215A compact power conditioner, and congratulations on your choice. The AC-215A power conditioners feature
Furman’s revolutionary Series Multi-Stage Protection (SMP) circuit, Extreme Voltage Shutdown (EVS), and our exclusive Linear Filtering Technology (LiFT). Together, these technologies comprise precisely what our customers have come to expect from Furman - uncompromised AC protection and purication. Our
AC-215A has been precisely engineered to exceed the critical demands of audio/video professionals, contractors, broadcasters, and musicians alike.
SMP (SERIES MULTI-STAGE PROTECTION)
Furman’s SMP surge suppression virtually eliminates service calls and costly “down time”. Traditional surge suppression circuits sacrice themselves when exposed to multiple transient voltage spikes, requiring the dismantling of your
system and repair of your surge suppressor. Not so with Furman’s SMP. Dam-
aging transient voltages are safely absorbed, clamped, and dissipated. Your connected equipment is protected, while your Furman protects itself!
EVS (EXTREME VOLTAGE SHUTDOWN)
Furman’s trusted over-voltage (EVS) circuitry protects against prolonged overvoltage conditions. It does so by monitoring the incoming voltage and,
when an unsafe condition is detected, triggering a relay which shuts off the
incoming power until the overvoltage condition is corrected. The unit will reset automatically when voltage is returned to a safe level.
4
LiFT (LINEAR FILTERING TECHNOLOGY)
Unfortunately, traditional AC power conditioners have been designed for
unrealistic laboratory conditions. Prior technologies, whether multiple-pole
or conventional series-mode lters, could actually harm audio and video
performance more than they help, due to the resonant peaking of their
antiquated, non-linear designs. Under certain conditions, these designs can actually add more than 10 dB of noise to the incoming AC line! Worse still, lost digital data, the need to reboot digital presets, or destruction of sensitive digital converters are frequently caused by excessive voltage spikes and AC noise contaminating the equipment ground. Furman’s LiFT takes a different approach, ensuring optimal performance through linear AC noise ltering with
no ground contamination.
SAFETY INFORMATION
To obtain best results from your Furman AC-215A Power Conditioner, please be sure to read this manual carefully before using.
WARNING
To reduce the risk of electrical shock, do not expose this equipment to rain or moisture. Dangerous high voltages are present inside the enclosure. Do not remove the covers. There are no user serviceable parts inside. Refer servicing to qualied personnel only.
IMPORTANT SAFETY INSTRUCTIONS
1. Please read and observe all safety and operating instructions before
installing your unit. Retain these instructions for future reference.
2. Your unit should not be used near water – for example, near a bathtub,
washbowl, kitchen sink, laundry tub, in a wet basement, near a swimming pool, etc.
3. Do not place your unit near heat sources such as radiators, heat registers,
stoves or other appliances that produce heat.
4. The unit should only be connected to a 120 VAC, 60Hz grounded electrical outlet. Do not defeat the ground or change polarization of the power plug.
5. Route the power cord and other cables so that they are not likely to be
walked on, tripped over, or stressed. Pay particular attention to the condition
ENGLISH
FRANÇAIS
ESpAÑoL
5
of the cords and cables at the plugs, and the point where they exit your
unit. To prevent risk of re or injury, damaged cords and cables should be
replaced immediately.
6. Clean your unit with a damp cloth only. Do not use solvents or abrasive cleaners. Never pour liquid on or into the unit.
7. Your unit should be serviced by qualied service personnel when:
• The power supply cord or the plug has been frayed,
kinked, or cut.
• Objects have fallen or liquid has spilled into the unit.
• The unit has been exposed to rain or other moisture.
• The unit does not appear to operate normally or exhibits
a marked change in performance.
• The unit has been dropped, or the enclosure damaged.
8. Your unit requires that a safety ground be present for proper operation.
Any attempt to operate the unit without a safety ground is considered
improper operation and could invalidate the warranty.
9. Do not attempt to service your unit beyond what is described in this manual. All other servicing should be referred to qualied service personnel.
OPERATION
EXTREME VOLTAGE SHUTDOWN INDICATOR
The Extreme Voltage Shutdown LED is normally off. If an input voltage in
excess of 137VAC is sensed, either on initial power-up or during normal operation, the AC-215A will shut off power and this indicator will light.
NOTE: If the mains power is above the high cutoff voltage and has caused the unit to remove power from its outlets, it cannot restore power until the mains power returns to a lower nominal level. If the main power remains high, check
the source of the problem, and if necessary, change the AC source.
PROTECTION OK INDICATOR
Although the Furman SMP circuit assures protection from transient voltage
spikes and surges, nature has a way of occasionally creating electrical forces
that are beyond the capabilities of any TVSS device to absorb without some
degree of damage. In the rare instance that this occurs, the green “Protection OK” LED indicator located on your front panel will turn off. If this happens,
6
some level of protection from voltage surges will remain, but the Furman’s clamping voltage rating will be compromised. The unit must be returned to Furman Sound, or an authorized Furman Service center for repair.
TROUBLESHOOTING
Symptom: No power to the AC outlets.
Possible Cause: Circuit breaker has tripped due to excessive load
Action Needed: Unplug one piece of equipment from the AC-215A and push
the re-set tab into the circuit breaker bezel.
Symptom: No power to the AC outlets, even after the circuit breaker has
been re-set.
Possible Cause: Protection devices are damaged.
Action Needed: Contact the Furman Service Department at 707-763-1010.
Symptom: Extreme Voltage (EVS) indicator lit.
Possible Cause: Input voltage is outside of nominal operation levels. This may
be caused by wiring faults at your location or downed power lines.
Action Needed: Unit will automatically reset and resume operation once the problem has been corrected.
INSTALLATION
The AC-215A can be conveniently and inconspicuously mounted within an equipment rack or on the rear panel of your video display, using the included
brackets. Refer to the illustrations below for instructions.
ENGLISH
FRANÇAIS
ESpAÑoL
7
The brackets can be positioned facing in or out as shown to best allow for different types of installations.
SERVICE
If you require technical support or equipment service, please contact the Furman Service Department at 707-763-1010. You may also email info@ furmansound.com. All equipment being returned for repair must have a Return
Authorization (RA) number. To get an RA number, please call the
Furman Customer Service Department. Before returning any equipment for repair, please be sure that it is adequately packed and cushioned against damage in shipment, and that it is insured. We suggest that you save the original packaging and use it to ship the product for servicing. Also, please provide a note giving your name, address, phone number, RA number and a
description of the problem.
3 YEAR LIMITED WARRANTY
SAVE YOUR SALES RECEIPT! The receipt is your proof of purchase and con-
rms the product was purchased at an authorized Furman dealer. It will need
to be submitted to Furman in order to process any warranty claims. Furman, a brand of Panamax Inc., warrants its AC-215A (the “Product”) as
follows: Furman warrants to the original purchaser of the product that the
product sold hereunder will be free from defects in material and workmanship for a period of three years from the date of purchase. If the product does not
conform to this Limited Warranty during the warranty period (as herein above specied), purchaser shall notify Furman of the claimed defects by calling 707-763-1010 or via email (info@furmansound.com.). If the defects are of such type and nature as to be covered by this warranty, Furman shall autho-
8
rize purchaser to return the product to Furman headquarters. Warranty claims MUST be accompanied by a copy of the original purchase invoice or receipt showing the purchase date. Shipping charges to Furman headquarters must
be prepaid by the purchaser of the product. Furman shall, at its own expense,
furnish a replacement product or, at Furman’s option, repair the defective
product. Return shipping charges back to purchaser will be paid by Furman.
CONNECTED EQUIPMENT WARRANTY: Furman’s Connected Equipment Warranty covers equipment that is damaged by transient voltage (an
“Occurrence”) while properly connected through the Furman AC-215A to a
properly wired AC power line with a protective ground in an indoor location. Furman’s Connected Equipment Warranty is limited to the amount of the
deductible on the Purc haser’s personal property insurance policy up to
$500.00. In order to make a claim for this Connected Equipment Warranty,
the Purchaser must forward a copy of his/her personal property insurance
claim for the damaged equipment to Furman and complete the Furman Connected Equipment Warranty claim form (call Furman at (707) 763­1010 to obtain the form). Furman reserves the right to review the damaged Furman product, the damaged connected equipment, and the site where the damage occurred. All cost of shipping damaged equipment to Furman for inspection shall be bor ne solely by the Purchaser. Damaged equipment must remain available for inspection until the claim is nalized. The Connected Equipment Warranty is also in effect for a period of three years unless the Purchaser does not complete the warranty registration within fteen days from date of purchase, at which time, the Connected Equipment Warranty
period is also reduced to one year from the date of purchase. All warranties
contained herein are null and void if: the Furman Surge Protector in use during the occurrence is not provided to Furman for inspection upon Furman’s request at the sole expense of the Purchaser, Furman determines that the
Furman Surge Protector has been opened, improperly installed, altered in any way or tampered with, Furman determines that the damage did not result from the Occurrence or that no Occurrence in fact took place or
Furman determines that the connected equipment was not used under normal
operating conditions or in accordance with Manufacturer’s instructions for the
connected equipment. All Furman Surge Protectors must be plugged directly into a properly wired AC power line with a protective ground and must
not be “daisy-chained” together in serial fashion with other power strips,
ENGLISH
FRANÇAIS
ESpAÑoL
9
UPS’s, other surge protectors, three-to-two-prong adapters, or extension
cords. Any suc h installation voids this warranty. The Furman warranty only protects against damage to properly connected equipment where Furman
has determined, at its sole discretion, that the damage resulted from an Occurrence and does not protect against acts of God (other than lightning)
such as ood, earthquake, war, terrorism, vandalism, theft, normal-use
wear and tear, erosion, depletion, obsolescence, abuse, damage due to
low-voltage disturbances (i.e. brownouts or sags), non-authorized program, or system equipment modication or alteration. Do not use this product in anyway with a generator, heater, sump pump, water-related device, life support device, medical device, automobile, motorcycle, or golf-cart battery
charger. To be used indoors only and in dry areas. All warranties contained
herein are null and void if used in anyway with any of the aforementioned devices.
THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Furman does not warrant against damages or defects arising out of improper use or abnormal handling of the product, or against defects or damages arising from improper installation. This warranty shall be cancelable by
Furman at its sole discretion if the product is modied in any way without
written authorization from Furman or Panamax Inc. This warranty also does not
apply to products upon which repairs have been affected or attempted by
persons other than pursuant to written authorization by Furman or Panamax Inc.
THIS WARRANTY IS EXCLUSIVE. The sole and exclusive obligation of Furman shall be to repair or replace the defective product in the manner and for the period provided above. Furman shall not have any other obligation with
respect to the products or any part thereof, whether based on contract, tort, strict liability or otherwise. Under no circumstances, whether based on this Limited Warranty or otherwise, shall Furman be liable for incidental, special,
or consequential damages. This Limited Warranty states the entire obligation
of Furman with respect to the product. If any part of this Limited Warranty
is determined to be void or illegal, the remainder shall remain in full force
and effect.
10
SPECIFICATIONS AC-215A
AC Current Capacity Input: 10 Amp capacity required Output: 10 Amp RMS (both outlets combined)
AC Noise Attenuation, Transverse (Differential) Mode
>40dB @ 100kHz >50dB @ 500kHz (linear attenuation curve from 0.05 to 100Ω line impedance)
Transient Voltage Surge Suppression 120VAC
Series Multi-Stage Protection
Non-Sacricial with Zero Ground Contamination 188V peak clamping @ 6000V/3000A input
Extreme Voltage Shutdown 137 VAC typically
Dimensions & Weight
1.75” (H) x 5” (W) x 8.5” (D), 3 lbs. Safety Agency Listing
cTUVus
POWER CORD INLET SECURITY CLAMP
To attach or detach the AC power cord security clamp, simply assemble or
disassemble as shown in the above illustration. Place clamp together as shown, and secure screws in the provided holes to lock the power cord in place. Loosen screws and remove clamp from unit to detach.
ENGLISH
FRANÇAIS
ESpAÑoL
11
Loading...