Fujitsu PRIMERGY 400, PRIMERGY 200 Operating Manual

Page 1
OPERATING MANUAL
OPERATING MANUAL
OPERATING MANUALOPERATING MANUAL
PRIMERGY 400/200
PRIMERGY 400/200
PRIMERGY 400/200PRIMERGY 400/200
SERVER SYSTEMS
Page 2
Is there ...
r
... any technical problem or other question you need clarified?
Please contact:
• one of our service partners
• your sales partne
• your sales outlet
The addresses of your service partners are contained in the guarantee booklet or in the service address booklet.
The latest information on our products, tips, updates, etc., can be found on the Internet under:
http://www.fujitsu-siemens.com
Page 3
Page 4
Dieses Handbuch wurde auf Recycling-Papier gedruckt. This manual has been printed on recycled paper. Ce manuel est imprimé sur du papier recyclé. Este manual ha sido impreso sobre papel reciclado. Questo manuale è stato stampato su carta da riciclaggio. Denna handbok är tryckt på recyclingpapper. Dit handboek werd op recycling-papier gedrukt.
Herausgegeben von/Published by Fujitsu Siemens Computers GmbH
A26361-K632-Z100-1-7619
Bestell-Nr./Order No.: Printed in the Federal Republic of Germany AG 0400 04/00
A26361-K632-Z100-1-7619
A26361-K632-Z100-1-7619A26361-K632-Z100-1-7619
A26361-K632-Z100-1-7619
Page 5
Introduction
Important notes
PRIMERGY 400/200
OPERATING MANUAL
Installation
Preparation for use and operation
Propertyand data protection
Troubleshootingand tips
System expansions for tower server
System expansions for rack server
April 2000 edition
Technical data
Index
Page 6
Intel and Pentium are registered trademarks of Intel Corporation, USA. NetWare and Novell are registered trademarks of Novell, Inc. SCO and SCO Unix are registered trademarks of Santa Cruz Operation. Windows is a registered trademark and Windows NT is a trademark of Microsoft Corporation. All other trademarks referenced are trademarks or registered trademarks of their respective
owners, whose protected rights are acknowledged.
Copyright ã Fujitsu Siemens Computers GmbH 2000
All rights, including rights of translation, reproduction by printing, copying or similar methods, even of parts are reserved.
Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design,
are reserved. Delivery subject to availability. Right of technical modification reserved.
Page 7

Contents

Introduction .....................................................................................................................................1
Features............................................................................................................................................ 1
Notational conventions ......................................................................................................................3
Important notes ...............................................................................................................................5
Safety................................................................................................................................................5
Manufacturer’s notes......................................................................................................................... 6
CE certificate.............................................................................................................................6
FCC Class A Compliance Statement......................................................................................... 7
Power cord selection.........................................................................................................................8
Transporting the server....................................................................................................................10
Installation .....................................................................................................................................11
Instructions on connecting and disconnecting cables ......................................................................11
Installing the tower server................................................................................................................12
Installing the rack server..................................................................................................................17
Preparation for use and operation ...............................................................................................27
Unlocking tower server....................................................................................................................27
Controls and indicators....................................................................................................................29
Switching the server on and off .......................................................................................................31
Configuring the server and installing the operating system..............................................................33
Locking tower server .......................................................................................................................34
Service compartment in tower server ..............................................................................................35
Cleaning the server .........................................................................................................................35
Property and data protection........................................................................................................37
BIOS Setup security functions.........................................................................................................37
Troubleshooting and tips..............................................................................................................39
Power-on indicator remains dark after you have switched on your device.......................................39
The server switches itself off ...........................................................................................................39
The screen stays blank....................................................................................................................39
Flickering stripes on the monitor screen ..........................................................................................40
No screen display or display drifts...................................................................................................40
No mouse pointer displayed on the screen......................................................................................41
The floppy disk cannot be read or written........................................................................................41
Time and/or date is not correct........................................................................................................41
System will not boot after installing a new hard disk drive ...............................................................41
Drives are reported as "dead" at system boot..................................................................................42
Added drive is reported as defective................................................................................................42
Error messages on the screen.........................................................................................................42
For the United States and Canada.....................................................................................8
For the United Kingdom.....................................................................................................9
Disposal and recycling.............................................................................................................10
Connecting devices to the server.............................................................................................13
Connecting the monitor to the line voltage...............................................................................14
Connecting the server to the line voltage.................................................................................14
Fit assembly kit and rack-mount the server .............................................................................17
Mounting cable guides and routing cables...............................................................................21
Connecting devices to the server.............................................................................................24
Connecting the server to the line voltage.................................................................................25
ServerStart..............................................................................................................................33
A26361-K632-Z100-1-7619
Page 8
Contents
System expansions for tower server........................................................................................... 43
Opening the server ......................................................................................................................... 43
Assembling the server .................................................................................................................... 46
SCSI hard disk drives ..................................................................................................................... 48
Installing a SCSI hard disk drive ............................................................................................. 49
Removing a SCSI hard disk drive............................................................................................ 50
RemoteView chipdisk...................................................................................................................... 51
Installing a RemoteView chipdisk............................................................................................ 51
Removing a RemoteView chipdisk.......................................................................................... 53
Accessible drives............................................................................................................................ 55
Installing an accessible 5 ¼-inch drive.................................................................................... 55
Removing an accessible 5 ¼-inch drive.................................................................................. 57
Changing the floppy disk drive ................................................................................................ 58
Boards............................................................................................................................................ 58
Installing a board..................................................................................................................... 59
Removing a board................................................................................................................... 60
Power supply module...................................................................................................................... 60
Installing the power supply module ......................................................................................... 61
Removing the power supply module........................................................................................ 63
Exchanging the fan......................................................................................................................... 65
Extensions on the system board..................................................................................................... 66
System expansions for rack server............................................................................................. 67
Opening the server ......................................................................................................................... 67
Assembling the server .................................................................................................................... 69
Accessible drives............................................................................................................................ 72
Installing an accessible 5 ¼-inch drive.................................................................................... 72
Removing an accessible 5 ¼-inch drive.................................................................................. 74
Changing the floppy disk drive ................................................................................................ 76
Technical data............................................................................................................................... 77
Index.............................................................................................................................................. 79
A26361-K632-Z100-1-7619
Page 9

Introduction

The PRIMERGY400 and 200 are Intel-based servers for small and medium-sized networks and can be used as tower or rack servers. Conversion to the respective other version is possible with an optional conversion kit.
The PRIMERGY 400 and 200 servers offer a high level of failure safety and availability through highly developed hardware and software components. Hardware components include hot-replace carriers, the ServerView server management , PDA (Prefailure Detection and Analyzing) and ASR&R (Automatic Server Reconfiguration and Restart).
Security functions in the BIOS Setup and on the system board protect the data on the server against manipulation. As a tower server, the lockable door and an anti-theft protection device on the back of the unit offer additional protection. As a rack server, the lockable door of the rack offers additional safety.
This Operating Manual tells you how to put your server into operation, how to operate it in daily use and how to expand your server. Work steps which are identical for the tower and rack version are only described for the tower version.
Further information is provided:
• in the manual "Safety, Guarantee and Ergonomics"
• in the Technical Manual of the system board
• in the manual for the BIOS Setup
• in the Technical Manual for the 19-inch rack (Rack-Server)
• in the manual for the monitor
• in the manual for the ServerView server management
• in the manual for the Remote Test and Diagnosis System RemoteView
• in the documentation for the boards and drives
• in the documentation of your operating system
• in the information files of your operating system

Features

System board
System boards with various features are available for the PRIMERGY 400 and 200 server systems to suit a wide range of requirements. For a description of the features of the system board integrated in your server, please see the manuals System Board for the hardware and BIOS Setup for the software.
Hard disk subsystem
The hard disk subsystem comprises four or six 3 ½-inch hard disk carriers and the SCSI platter. Each hard disk carrier can accommodate an SCSI hard disk drive with an SCA (Single Connector Attachment) interface and a maximum height of 1.6 inches or 1 inch. The module is connected to the SCSI disk without cables via the SCA interface. This allows the hard disk drive to be simply plugged in or pulled out.
The hard disk subsystem is designed for 80 MHz SCSI. The version with four 3 ½-inch hard disk carriers is a 1-channel, the version with six 3 ½-inch hard disk carriers can be configured as 2­channel with two hard disks or as 1-channel with six hard disks. The hard disk subsystem can be controlled by a standard controller or by a disk array controller (DAC). If the server is equipped with a DAC, defective hard disk drives can also be replaced during operation (hot replace).
A26361-K632-Z100-1-7619 1
Page 10
Introduction Features
Power supply
The server can be equipped with a permanently installed power supply (standard) or with a plug-in power supply (hot plug) consisting of one or two modules. With two power supply modules the server is equipped with a redundant power supply. If a defect occurs in one module, the respective other module ensures unimpaired further operation. The defective module can be replaced during operation.
High level of availability and failure protection
When accessing stored data, 1-bit-errors in the main memory are automatically recognized and corrected (EDC = Error Detection and Correction). The patented memory scrubbing function regularly starts up the EDC mechanism and thus ensures continuous data integrity. ASR&R tunes out defective system components during an automatic system reboot. The Prefailure Detection and Analyzing Technology reports the threat of system errors or problems to the system administrator so that preventative measures can be taken. The optional disk array controller increases system availability and supports the RAID levels 0, 1 and 5. The hot-replace-capable hard disks provide additional protection.
Server management
Server management is implemented with the aid of the supplied ServerView software and PDA (Prefailure Detection and Analyzing) technology from Fujitsu Siemens. The PDA analyzes and monitors all components relevant to system reliability, thus enabling early detection of overload situations and appropriate counter-measures.
ServerView enables the management of all PRIMERGY servers in the network via a central console. Here ServerView supports the following functions:
• Temperature monitoring of the CPU and the surrounding area.
• Timer-controlled switch-on (Timer)
• Remote switch-on (Ring Indicator)
• Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R) in the event of
failure of memory modules or processors.
• Pager message when rebooting system following an error
• Monitoring ISA and PCI bus loading
• End-of-Life monitoring of the fans with timely indication before failure
• Watchdog timer for operating system monitoring and application monitoring
• Detailed status and error reports for bus systems, processors and main memory
• Statistics for service technicians (operating hours counter, counter for switch-on/switch-off
cycles)
• Storage of 50 error messages in the non-volatile SRAM memory
Further information on the ServerView server management is provided in the associated documentation.
ServerStart
You can configure the PRIMERGY server quickly and purposefully with the ServerStart software provided. User-guided menus are available for installing the server operating systems.
Service and Support
PRIMERGY devices are service-friendly and modular, thus enabling quick and simple maintenance. The flash EPROM program supplied with the Fujitsu Siemens utilities supports fast BIOS update. With the optional Remote Test and Diagnosis System RemoteView, long-distance maintenance and service (remote) can also be performed on the servers of the PRIMERGY 400 series.
2 A26361-K632-Z100-1-7619
Page 11
Notational conventions Introduction

Notational conventions

The meanings of the symbols and fonts used in this manual are as follows:
Pay particular attention to texts marked with this symbol. Failure to observe this warning endangers your life, destroys the system, or may lead to loss of data.
!
Supplementary information, remarks and tips follow this symbol.
i
Ê Texts which follow this symbol describe activities that must be performed in the order shown.
Texts in italics indicate commands or menu items. "Quotation marks" indicate names of chapters and terms that are being emphasized.
A26361-K632-Z100-1-7619 3
Page 12
Page 13

Important notes

In this chapter you will find information regarding safety which it is essential to take note of when working with your server. The manufacturer's notes contain helpful information on your server.

Safety

This device complies with the pertinent safety regulations for information technology, including electric office machines for use in an office environment. If you have any questions, contact your sales outlet or our customer service center.
The safety information is contained in the manual " Safety, Guarantee and Ergonomics". The following outlines some of the most important safety information:
• During installation and before operating the device, please observe the instructions on
environmental conditions in the chapter entitled "Technical data" as well as the instructions in the chapter "Installation".
• The ON/OFF switch and the main switch do not disconnect the server from the line voltage. To
disconnect the line voltage completely, remove the power plug from the grounded power outlet.
• When cleaning the Server, observe the relevant notes in the chapter "Preparation for use and
operation".
• When connecting and disconnecting cables, observe the relevant notes in the chapter
"Installation".
• Replace the lithium battery on the system board in accordance with the instructions in the
Technical Manual for the system board.
• The CD-ROM drive contains a light-emitting diode (LED), classified according to IEC 825-
1:1993:LASER CLASS 1.
• Keep this Operating Manual together with your device. If you pass on the device to third
parties, you should include this manual.
• Caution: components on the system board can get very hot.
• Please check whether the server is set to the local line voltage (see chapter "Installation"
section "Connecting the server to the line voltage").
A26361-K632-Z100-1-7619 5
Page 14
Important notes Manufacturer's notes
Boards with electrostatic sensitive devices (ESD) may be identified by labels.
When you handle boards fitted with ESDs, you must observe the following points under all circumstances:
• You must always discharge yourself (e. g. by touching a grounded object) before working.
• The equipment and tools you use must be free of static charges.
• Pull out the power plug before inserting or pulling out boards containing ESDs.
• Always hold boards with ESDs by their edges.
• Never touch pins or conductors on boards fitted with ESDs.

Manufacturer's notes

CE certificate

The shipped version of this device complies with the requirements of the EEC directives 89/336/EEC "Electromagnetic compatibility" and 73/23/EEC "Low voltage directive".
6 A26361-K632-Z100-1-7619
Page 15
Manufacturer's notes Important notes

FCC Class A Compliance Statement

If there is an FCC statement on the device, then: The following statement applies to the products covered in this manual, unless otherwise specified herein. The statement for other products will appear in the accompanying documentation.
NOTE:
This equipment has been tested and found to comply with the limits for a "Class A" digital device, pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference­Causing Equipment Regulations. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in strict accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between equipment and the receiver.
· Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
· Consult the dealer or an experienced radio/TV technician for help.
Fujitsu Siemens Computers GmbH is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu Siemens Computers GmbH. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC rules.
A26361-K632-Z100-1-7619 7
Page 16
Important notes Power cord selection

Power cord selection

The power cord for this unit has been packed separately and has been selected for use in the appropriate country. It must be used to prevent electric shock. Use the following guidelines if it is necessary to replace the original cord set.
The female receptacle of the cord set must meet CEE-22 requirements (see Figure).

For the United States and Canada

Use a UL listed and CSA labeled cord set consisting of a three-conductor cord with a maximum length of 15 feet.
For units that stand on a desk or table, type SVT or SJT cord sets shall be used. For units that stand on floor, only SJT type cord sets shall be used. The cord set must be selected according to the current rating for your unit. Please consult Table A
for the selection criteria for power cords used in the United States and Canada.
Table A:
Cord Type Size of Conductors
in Cord
SJT 18 AWG
16 AWG 14 AWG
SVT 18AWG
17 AWG
Maximum Current
Rating of Unit
10 Amps 12 Amps 12 Amps 10 Amps 12 Amps
For units set at 115 V:
use a parallel blade, grounding type attachment plug rated 15 A, 125 V.
8 A26361-K632-Z100-1-7619
For units set at 230 V (domestic use):
use a tandem blade, grounding type attachment plug rated 15 A, 250 V.
Page 17
Power cord selection Important notes
For units set at 230 V (outside of the United States and Canada):
use a cord set consisting of a minimum AWG according to Table A and a grounding type attachment plug rated 15 A, 250 V. The cord set should have the appropriate safety approvals for the country in which the equipment will be installed and should be marked HAR.

For the United Kingdom

Should the plug on the flexible cord not be of the type for your socket outlets, do not use an adapter but remove the plug from the cord and discard. Carefully prepare the end of the supply cord and fit a suitable plug.
WARNING
THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in this mains lead are colored in accordance with the following code:
Green and Yellow: Earth Blue: Neutral Brown: Live
As the colors of the wires in the mains lead of this appliance may not correspond with the colored markings identifying the terminals in your plug, proceed as follows:
· The wire which is colored Green and Yellow must be connected to the terminal in the plug
which is marked with the letter E or by the earth symbol or colored Green or Green and Yellow.
· The wire which is colored Blue must be connected to the terminal which is marked with the
letter N or colored Black.
· The wire which is colored Brown must be connected to the terminal which is marked with the
letter L or colored Red.
A26361-K632-Z100-1-7619 9
Page 18
Important notes Transporting the server

Disposal and recycling

This device has been manufactured to the greatest possible degree from materials which can be recycled or disposed of in a manner that is not environmentally damaging. The device is taken back after use, to be recycled, provided that it is returned in a condition that is the result of normal use. Any components not reclaimed will be disposed of in an environmentally acceptable manner.
Do not throw lithium batteries or accumulators into the trashcan. They must be disposed of in accordance with local regulations concerning special waste.
If you have any questions on disposal, please contact your local office, our customer service center, or:
Fujitsu Siemens Computers GmbH Recyclingcenter D-33106 Paderborn
Tel.: +49 5251 818010 Fax: +49 5251 818015

Transporting the server

Transport the server only in its original packaging or in a packaging which protects it from knocks and jolts, to the new site. Do not unpack the server until all transportation
!
maneuvers are completed. If you need to lift or transport the server, ask someone to help you.
10 A26361-K632-Z100-1-7619
Page 19

Installation

Please take note of the safety information in the chapter "Important notes".
!
It is recommended not to throw away the original packaging material! It may be required for transportation at some later date.
Ê Unpack all the individual parts. Ê Check the delivery for damage incurred during transportation. Ê Check whether the delivery agrees with the details in the delivery note. Ê Check whether all necessary details have been entered on the first page of the guarantee
coupon booklet. The model rating plate is located on the left-hand side of the server. Should you discover that the delivery does not correspond to the delivery note, notify your supplier
immediately.

Instructions on connecting and disconnecting cables

Be sure to read the documentation on the external devices before connecting them.
!
Do not connect or disconnect cables during a thunderstorm. Always take hold of the actual plug body. Never unplug a cable by pulling the cable itself. Connect and disconnect the cables in the order described below.
Connecting cables
• Turn off all power and equipment switches.
• Pull all power plugs out of the grounded power outlets.
• Plug all cables into the server and peripherals.
• Plug all data communication cables into the utility sockets.
• Plug all power cables into the grounded power outlets.
Disconnecting cables
• Turn off all power and equipment switches.
• Pull all power plugs out of the grounded power outlets.
• Unplug all data communication cables from the utility sockets.
• Disconnect the relevant cables at the server and at the peripherals.
A26361-K632-Z100-1-7619 11
Page 20
Installation Installing the tower server

Installing the tower server

Do not expose the server to extreme environmental conditions (see chapter "Technical
data"). Protect it from dust, humidity and heat.
!
There must be a clearance of at least 200 mm in front of and behind the server to ensure adequate ventilation. Do not cover the ventilation areas of the monitor and the server.
Prepare the keyboard
Ê Plug the appropriate connector of the keyboard cable into the socket on the underside of the
keyboard as shown in the illustration above.
12 A26361-K632-Z100-1-7619
Page 21
Installing the tower server Installation

Connecting devices to the server

The ports for external devices are on the rear of the server. Which ports are available on your server depend on the boards installed. The standard ports are indicated by symbols.
8 9
4
1
5
2
6
3
CAN
7
1 = Monitor port 2 = Serial port 1 3 = Keyboard port 4 = Parallel port 5 = Serial port 2
6 = PS/2 mouse port 7 = CAN-bus port 8 = Slots for additional ports 9 = Slots for additional ports
Ê Connect the data cables at the server and peripherals.
Some of the devices that you connect require special drivers (see the documentation for the connected device).
i
If a separate graphics card is used in a slot, then the graphics controller on the system board is automatically deactivated. The related monitor port (1) cannot be used. Instead, connect the data cable of the monitor to the monitor port of the graphics card.
A26361-K632-Z100-1-7619 13
Page 22
Installation Installing the tower server

Connecting the monitor to the line voltage

Servers with the standard power supply enable the power cable of the monitor to be connected to the server.
2
1
Ê Depending on the connector and the power supply, plug the monitor's power cable into either
the server (1) or a grounded power outlet (2).
You may only plug the monitor power cable into the monitor connector of the server if the rated current of the monitor is not more than 1.5 A (230 V) or 3 A (115 V). The rated
!
current for the monitor is also given on the monitor itself or in the Operating Manual for the monitor.

Connecting the server to the line voltage

The server can be equipped with a permanently installed power supply (standard) or with a plug-in power supply (hot plug) consisting of one or two modules. With two power supply modules the server is equipped with a redundant power supply. If a defect occurs in one module, the respective other module ensures unimpaired further operation. The defective module can be replaced during operation.
Standard power supply
The power supply of the server can be set to the following line voltage range: 100Vto125Vor200Vto240V.
Before connecting the server to the line voltage, you must always check that the line voltage range set on the server corresponds to the local line voltage. The marker arrow on
!
the plug-in unit points to the voltage range set.
14 A26361-K632-Z100-1-7619
Page 23
Installing the tower server Installation
230 115
a
Ê If the wrong line voltage range is set, lift out the plug-in unit with a screwdriver (a), turn it and
replace it.
2
1
Ê Connect the power cable to the server's power connector (1) and to a free grounded power
outlet (2).
A26361-K632-Z100-1-7619 15
Page 24
Installation Installing the tower server
Modular hot-plug power supply
There are two types of hot-plug-capable power supply modules, which are easy to distinguish on the connection side (see following illustration). Both versions automatically adjust to the proper voltage range.
A server may only be equipped with one type of power supply module. Mixed equipping will cause the modules to be destroyed.
!
a
2
1
a
2
1
a = yellow and green status indicator
Ê Connect each power supply module to a grounded power outlet with the power cable supplied
(1 + 2). The yellow status indicator glows when line voltage is connected to the power supply module. The green status indicator glows when the power supply module is ready for operation, or it remains
dark when the power supply module is defective.
16 A26361-K632-Z100-1-7619
Page 25
Installing the rack server Installation

Installing the rack server

Do not expose the server to extreme environmental conditions (see chapter "Technical
data"). Protect it from dust, humidity and heat.
!
Installation steps
• Mount assembly kit and insert server (see order lists for location diagram prepared with Rack
Architect)
• Connect the devices to the server in accordance with the rack configuration.
• Connecting the server to the line voltage
• Routing cables

Fit assembly kit and rack-mount the server

Ê Using the mounting aid (stencil) mark the position of the attachment points on the support
upright of the server. Refer to the information on the mounting aid. The server requires five height units.
One height unit corresponds to 4.445 cm and is defined by the hole sequence on the support upright round hole-oblong hole-round hole . The oblong hole marks the middle of a
i
height unit.
ca 45˚
1
Ê Place the spring nuts in the groove of the support uprights at the marked attachment points (1 -
4).
Ê If necessary, adjust the position of the nuts in the groove until they lock into the correct position
(5).
A26361-K632-Z100-1-7619 17
2
5
3
4
5
Page 26
Installation Installing the rack server
a
1
Ê Hook the two extending units into the oblong holes of the support uprights at the appropriate
height with the hooks on the back. The mounting plates of the extending units with the beveled
corners (a) must face toward the front.
Ê Screw the hooked-in extending units into the rack (1) with the No. 5 allen key provided. Please
note that the guide nubs of the extending rails next to the spring nuts must fit into the holes in
the support uprights.
Ê Pull out the mounted extending units completely.
a
b
1
Ê Press the locking spring (a) at the back of the pulled-out extending rail and pull out (1) the inner
rail (b).
18 A26361-K632-Z100-1-7619
Page 27
Installing the rack server Installation
1
Ê Screw the two inner rails onto the server at the left and right with four countersunk screws (1).
1
a
Ê Insert the server with the mounted inner rails into the extending rails of the extending unit (1)
until the locking spring (a) of both inner rails engages.
A26361-K632-Z100-1-7619 19
Page 28
Installation Installing the rack server
1
2
Ê Press the locking spring (1) on both sides and push the server into the rack (2).
1
Ê Secure the server in the rack (1) using the four knurled screws.
20 A26361-K632-Z100-1-7619
Page 29
Installing the rack server Installation
r

Mounting cable guides and routing cables

Because of the different maximum cable lengths in single-ended and differential-ended SCSI mode, two types of cable routing are possible in the rack: limited and unlimited cable routing.
Unlimited cable routing
A maximum cable length of 20 m is possible for differential-ended SCSI operation. With this the SCSI cables can be routed without restriction in the cable chain. The slide-in modules can thus be pulled out later without any further preparations.
When mounting the cable routing using a cable chain, proceed as follows:
2
2
1
2
a
Ê Lay the cables inside (1) and outside (2) in die cable chain. Make sure that sufficient cable
length is available for each cable on the slide-in module side for connection to the server.
Ê Secure the cables on the cable chain termination (a) with cable ties. Ê Route the cable chain equipped with the cables into the cable tray.
When you add cables to an already existent installation, then pull the server completely out of the rack (see "Opening the serve
i
then possible without detaching the cable chain from the cable tray. However, if cables are added in the outside chain, the cable chain must be detached from the cable tray and pulled out completely.
"). The equipping of the inner chain with cables is
A26361-K632-Z100-1-7619 21
Page 30
Installation Installing the rack server
1
Ê Insert two spring nuts in the rear right mounting rail at the level of the cable tray and screw the
rack angle piece onto these (1).
22 A26361-K632-Z100-1-7619
Page 31
Installing the rack server Installation
1
2
Ê Place the angle piece of the slide-in module into the bracket on the cable tray (1) and secure it
with the bayonet latch on the cable tray (2).
Ê Make sure the slide-in module can be pulled out and pushed in again easily.
Limited cable routing
When operating in the single-ended SCSI mode, the maximum cable length for external SCSI cables of 1.50 m or 1.80 m limits the way you can lay cables in the rack. Therefore, the SCSI cables cannot be routed in the cable chain.
Ê With limited cable routing, lay the cables loose in the slide-in module bottom tray.
When pulling the slide-in module, make sure that the corresponding cables are taken out of the rack cable guides beforehand.
A26361-K632-Z100-1-7619 23
Page 32
Installation Installing the rack server

Connecting devices to the server

All ports are on the rear of the server. The standard ports are indicated by symbols.
8
9
4
5
6
1
2
CAN
7
3
1 = Monitor port 2 = Serial port 1 3 = Keyboard port 4 = Parallel port 5 = Serial port 2
6 = PS/2 mouse port 7 = CAN-bus port 8 = Slots for additional ports 9 = Slots for additional ports
Ê Connect the data cables at the server and peripherals.
If a separate graphics card is used in a slot, then the graphics controller on the system board is automatically deactivated. The related monitor port (1) cannot be used. Instead, connect the data cable of the monitor or of the channel switch to the monitor connection of the graphics card.
Ê Mark the lines so that you can always identify them.
For a server with default power supply you may only plug the monitor power cable into the monitor connector of the server if the rated current of the monitor is not more than 1.5 A
!
(230 V) or 3 A (115 V). When connected to an uninterruptible power supply (UPS) the monitor must also be taken into account.
24 A26361-K632-Z100-1-7619
Page 33
Installing the rack server Installation

Connecting the server to the line voltage

The server can be equipped with a permanently installed power supply (standard) or with a plug-in power supply (hot plug) consisting of one or two modules. With two power supply modules the server is equipped with a redundant power supply. If a defect occurs in one module, the respective other module ensures unimpaired further operation. The defective module can be replaced during operation.
Standard power supply
The power supply of the server can be set to the following line voltage range: 100Vto125Vor200Vto240V.
Before connecting the server to the line voltage, you must always check that the line voltage range set on the server corresponds to the local line voltage. The marker arrow on
!
the plug-in unit points to the voltage range set.
100 V - 125 V
a
200 V - 240 V
Ê If the wrong line voltage is set, lift out the plug-in unit with a screwdriver (a), turn it and replace
it.
2
1
Ê Plug the power cable of the server into the server (1) and into a free electrical outlet of the
multi-outlet assembly in the rack (2) (see technical manual for rack).
A26361-K632-Z100-1-7619 25
Page 34
Installation Installing the rack server
Modular hot-plug power supply
There are two types of hot-plug-capable power supply modules, which are easy to distinguish on the connection side (see following illustration). Both versions automatically adjust to the proper voltage range.
A server may only be equipped with one type of power supply module. Mixed equipping will cause the modules to be destroyed.
!
a
2
1
a
2
1
a = yellow and green status indicator
Ê Connect each power supply module to a free electrical outlet of the multi-outlet assembly in the
rack (1 + 2) with the power cable provided (see technical manual for rack). The yellow status indicator glows when line voltage is connected to the power supply module. The green status indicator glows when the power supply module is ready for operation, or it remains
dark when the power supply module is defective.
26 A26361-K632-Z100-1-7619
Page 35

Preparation for use and operation

Please take note of the safety information in the chapter "Important notes".
!

Unlocking tower server

1
2b
2a
2
Ê Unlock the lock with the key (1). The door remains engaged. Ê If you only require access to the ON/OFF switch and the operable drives, then pull the drive
cover somewhat forward by the handle (2a) and then push it downward (2b). The key can be left in the lock.
Ê If you require access to the hard disk drive plug-in modules of the server, then open the door
(3).
A26361-K632-Z100-1-7619 27
3
Page 36
Preparation for use and operation Unlocking tower server
It is also possible to open the drive cover, however keep the door locked. Proceed as follows:
Ê Unlock the lock.
1
2
3
Ê Pull the lower section of the drive cover forward by the handle (1). Ê Lock the lock again (2). Ê Slide the drive cover downwards (3).
28 A26361-K632-Z100-1-7619
Page 37
Controls and indicators Preparation for use and operation

Controls and indicators

1
3
2
4
5
7
8
6
Tower server 1 = Indicator CD-ROM drive active
2 = Indicator SCSI bus active 3 = Power-on indicator 4 = ON/OFF switch
A26361-K632-Z100-1-7619 29
5 = Indicator chipcard reader active 6 = Indicator floppy disk drive active 7 = Indicator hard disk drive active 8 = Indicator hard disk drive error
Page 38
Preparation for use and operation Controls and indicators
2
1
4
3
5
6
7
8
Rack server 1 = Indicator hard disk drive error
2 = Indicator hard disk drive active 3 = Indicator floppy disk drive active 4 = Indicator chipcard reader active
30 A26361-K632-Z100-1-7619
5 = Indicator SCSI bus active 6 = Power-on indicator 7 = Indicator CD-ROM drive active 8 = ON/OFF switch
Page 39
Switching the server on and off Preparation for use and operation
ON/OFF switch
switches the server on or to ready-to-operate.
The ON/OFF switch and the main switch do not disconnect the server from the line voltage. To disconnect the line voltage completely, remove the power plug from the
i
socket.
System indicators
Power-on indicator
glows orange or does not light (P270), when the server is ready-to-operate. lights green when the server is switched on.
Drive active
lights green when an SCSI drive is being accessed.
Drive indicators
Hard disk drive active
Lights when the drive in this slot is being accessed. Drive error (only in conjunction with disk array controller)
Lights orange when the drive is defective and needs replacing, or if the slot is not correctly inserted.
Blinks orange when a rebuild is carried out by the DAC after changing a hard disk drive.
Indicator CD-ROM drive active
The indicator lights up when the CD-ROM drive is accessed.
Indicator floppy disk drive active
The indicator lights up when the floppy disk drive is being accessed.
Indicator chipcard reader active (optional)
lights up when the chipcard reader is being accessed.

Switching the server on and off

If after switching on the server there is nothing but flickering stripes on the screen, switch the server off immediately (see "Troubleshooting and tips"-"Flickering stripes on the
!
monitor screen").
The ON/OFF switch and the main switch do not disconnect the server from the line voltage. To disconnect the line voltage completely, remove the power plug from the socket.
Because only the servers with a standard power supply are equipped with an ON/OFF switch, the procedure for switching the servers on or off differs.
Server with modular power supply
Servers with a modular power supply are switched on or off by pressing the ON/OFF switch.
A26361-K632-Z100-1-7619 31
Page 40
Preparation for use and operation Switching the server on and off
Servers with standard power supply
a
b
c
115
230
0
230
115
1
a
c
b
0
1
Server is switched off
The main switch (a) is in position 0 and the power-on indicator (c) does not light. The ON/OFF switch (b) is inoperative. The screen socket on the server is dead.
Server is ready for operation (stand-by state)
The main switch (a) is in position 1 and the power-on indicator (c) glows orange or does not light (P270). The server can be switched on with the ON/OFF switch (b) or a signal. The screen socket on the server is live.
Server is switched on
The main switch (a) is in position 1 and the power-on indicator (c) lights up green. The server can be made ready for operation with the ON/OFF switch (b) or a signal. The screen socket on the server is live.
32 A26361-K632-Z100-1-7619
Page 41
Configuring the server and installing the operating systemPreparation for use and operation
Other switch-on methods
In addition to the ON/OFF switch, the server can be switched on in the following ways:
• Specified power-on time/power-off time
Using the ServerView program you can set the time at which the server is switched on or off.
• Ring indicator
The server can be switched on via an internal or external modem.
• After power failure
The system restarts automatically after a power failure.

Configuring the server and installing the operating system

This section contains information of the server configuration and on installing the operating system. Please note that the SCSI-IDs of the hard disk drives are permanently specified in the order 0, 1, 2,
3, or 0, 1, 2, 12, 13, 13 from bottom to top.

ServerStart

With the ServerStart CD provided you can configure the server and install the operating system in a convenient manner. The menu-guided configuration includes server configuration with SCU, ISA configuration with ICU and the disk array controller configuration with DACCF. To find out how to operate ServerStart and for further information see the corresponding CD booklet.
Note on SCSI-ID: Please note that the SCSI-IDs of the hard disk drives are permanently specified in the
i
order 0, 1, 2, 3 or 0, 1, 2, 12, 13, 14 from bottom to top. Note on SCO UNIX:
The DAC manual mentions the utility DAC960 when describing SCO UNIX installation. The name for this utility is no longer correct. Enter MDAC instead.
Note on Novell Netware 3.12: If you want to install Novell Netware 3.12, first set the APIC function (if existing) to Disabled in the Advanced menu in the BIOS Setup.
Descriptions of operating systems not covered in the DAC manual are provided in the appropriate readme files on the ServerStart CD.
Configuring the onboard SCSI controller
Ê Configure the onboard SCSI controller as described in the technical manual of the system
board and/or the readme files on the driver floppy disk.
A26361-K632-Z100-1-7619 33
Page 42
Preparation for use and operation Locking tower server

Locking tower server

1
2
2
3
Ê Close the drive cover (1) and/or the door of the server (2). Ê Turn the key counterclockwise (3).
34 A26361-K632-Z100-1-7619
Page 43
Service compartment in tower server Preparation for use and operation

Service compartment in tower server

For the safe, handy storage of CDs, floppy disks, administrator and/or maintenance notes (e.g. maintenance labels, server network address), the server is provided with a drawer on the front.

Cleaning the server

Switch the server off and pull the power plug out of the grounded-contact power socket.
!
Do not clean any interior parts yourself, leave this job to a service technician. Do not use any cleaning agents that contain abrasives or may corrode plastic. Ensure that no liquid enters the system. Ensure that the ventilation areas of the server and the monitor are free.
Wipe the server and monitor casing with a dry cloth. If particularly dirty, use a cloth which has been moistened in mild domestic detergent and then carefully wrung out.
Use disinfectant wipes to clean the keyboard and the mouse.
A26361-K632-Z100-1-7619 35
Page 44
Page 45

Property and data protection

The rack server is optimally protected against unauthorized access with the lockable rack door. The tower server is protected against unauthorized open and switching on/off with its own lockable
door. In addition, it is also equipped with anti-theft protection. At the bottom right on the rear there is a hole through which you can feed a steel cable for securing the server to an immovable object.
For protecting your system and your data internally from unauthorized access, you can use the BIOS Setup security functions.

BIOS Setup security functions

The Security menu in BIOS Setup offers you various options for protecting your data from unauthorized access. By combining these options, you can achieve optimum protection for your system.
You will find a detailed description of the Security menu and how to assign passwords in the manual for the BIOS Setup.
i
Preventing unauthorized BIOS Setup calls
You can activate this protection by setting a setup password in the Security menu. In addition, you can suppress the Press F2 for Setupmessage in the Security menu. This message is then no longer displayed while the server's startup routine is in progress.
Preventing unauthorized system access
You can activate this protection by setting a system password in the Security menu.
Preventing unauthorized access to the settings of boards with their own BIOS
You can activate this protection by selecting the value Extended for the Setup Password Lock field in the Security menu.
Preventing system booting from the diskette drive
You can activate this protection by selecting the value Diskette Lock for the System Load field in the Security menu.
Preventing unauthorized writing of diskettes
To activate this protection, select the value Disabled for the Diskette Write field in the Security menu.
Protecting BIOS from overwriting
To activate this protection, select the value Disabled for the Flash Write field in the Security menu.
Protecting the server from being switched on by an external device
To activate this protection select the value Disabled for the Remote Power On field in the Security menu.
Protecting server from being switched off by a program
To activate this protection select the value Disabled for the Soft Power Off field in the Security menu.
A26361-K632-Z100-1-7619 37
Page 46
Page 47

Troubleshooting and tips

Take note of the safety notes in the manual "Safety, Guarantee and Ergonomics" and in the chapter "Installation", when you connect or disconnect cables.
!
If a fault occurs, try to correct it as described:
• in this chapter
• in the documentation of the connected devices
• in the help systems of the software used.
If you fail to correct the problem, proceed as follows:
Ê Make a note of the steps and the circumstances that led to the fault. Also make a note of any
error messages displayed.
Ê Switch the server off. Ê Contact your customer service center.

Power-on indicator remains dark after you have switched on your device

Power cord incorrectly connected
Ê Make sure that the power cable is correctly connected to the server and to the grounded power
outlet.
Power supply overloaded
Ê Pull the power plug of the server out of the power outlet. Ê Wait a few seconds and plug the power plug into the power outlet again. Ê Switch your server on.

The server switches itself off

Server management has detected an error
Ê In the ServerView program check the error list or check the Error Log file using the SCU utility;
and attempt to eliminate the error.

The screen stays blank

Monitor is switched off
Ê Switch your monitor on.
A26361-K632-Z100-1-7619 39
Page 48
Troubleshooting and tips
Screen has been blanked
Ê Press any key on the keyboard.
or
Ê Deactivate screen blanking (screen saver). Enter the appropriate password.
Brightness control is set to dark
Ê Set the brightness control to bright. For detailed information, please refer to the Operating
Manual supplied with your monitor.
Power cable or monitor cable not connected
Ê Switch off the monitor and the server. Ê Check whether the power cable is properly connected to the monitor and to the power outlet. Ê Check whether the monitor cable is properly connected to the server and monitor (if it is
plugged in with a connector). If a separate graphics card is installed in the server, then the
monitor cable must be connected to the connection of this graphics card.
Ê Switch on the monitor and the server.

Flickering stripes on the monitor screen

Switch off the server immediately.
!
Monitor does not support the set horizontal frequency
Ê Find out which horizontal frequency your monitor screen supports. You will find the horizontal
frequency (also known as line frequency or horizontal deflection frequency) in the
documentation of your monitor.
Ê Refer to the documentation for your operating system or the corresponding driver software for
the screen controller for how to set the correct horizontal frequency for your monitor, and follow
the procedure accordingly.

No screen display or display drifts

The wrong horizontal frequency and/or resolution has been selected for the monitor or for the application program.
Ê Find out which horizontal frequency your monitor screen supports. You will find the horizontal
frequency (also known as line frequency or horizontal deflection frequency) in the
documentation of your monitor.
Ê Refer to the documentation for your operating system or the corresponding driver software for
the screen controller for how to set the correct horizontal frequency for your monitor, and follow
the procedure accordingly.
40 A26361-K632-Z100-1-7619
Page 49
Troubleshooting and tips

No mouse pointer displayed on the screen

Mouse driver not loaded
Ê Check whether the mouse driver is properly installed and is present when the application
program is started. Detailed information can be found in the User Guides of the mouse, the operating system or the application program.
Mouse controller disabled
The mouse controller on the system board must be enabled, if you use the supplied mouse.
Ê Check in the BIOS Setup that the mouse controller is Enabled.

The floppy disk cannot be read or written

Ê Check whether the write protection of the floppy disk is activated. Ê In the BIOS Setup check the entry for the floppy disk drive. Ê Check in the BIOS Setup whether the diskette drive controller and write permission are enabled
(see the Technical Manual for the system board).
Ê Check that the cables of the floppy disk drive are properly connected (refer to chapter "System
expansions for tower server").

Time and/or date is not correct

Ê Set the time and/or date in the operating system or in the BIOS Setup.
If the time and date are repeatedly wrong when you switch on your server, the battery is flat. Change the lithium battery as described in the Technical Manual of the system board.
i

System will not boot after installing a new hard disk drive

SCSI configuration incorrect (Ultra Wide SCSI Controller)
Ê In the SCSI configuration menu check the settings for the hard disk drives (SCSI Device
Configuration) and the settings under Advanced Configuration Options .
A26361-K632-Z100-1-7619 41
Page 50
Troubleshooting and tips

Drives are reported as "dead" at system boot

This error message may occur when the server has a disk array controller:
SCSI cabling incorrect
Ê Make sure the SCSI cable connection and the SCSI channel assignment still correspond to the
original state.
The Disk Array Controller configuration is incorrect
Ê Check and correct the settings for the drives with the DAC utility DACCF.
Further information is provided in the manual on the disk array controller.

Added drive is reported as defective

This error message may occur when the server has a disk array controller:
Disk Array Controller is not configured for this hard disk drive
The drive was probably installed with the system switched off.
Ê Reconfigure the disk array controller for the hard disk drive. Information is contained in the
documentation on the disk array controller. or
Ê Re-install the drive while the system is switched on.
If the hard disk drive continues to be shown as defective, then replace it (see "SCSI hard disk
drives").

Error messages on the screen

The meaning of the error message is contained in the manual on BIOS setup and in the documentation on the boards and programs used.
42 A26361-K632-Z100-1-7619
Page 51

System expansions for tower server

This chapter describes how to modify your server hardware (e.g. installing or removing boards or accessible drives).
Memory and processor upgrading as well as replacement of the lithium battery are described in the Technical Manual for the system board.
You will find an overview and a brief description of the installed system boards on the left­hand housing side cover of the server. A detailed description of the system board is
i
provided in the corresponding Technical Manual.

Opening the server

Please take note of the safety information in the chapter "Important notes".
!
Ê Switch the server off.
Pull all power plugs out of the power outlets!
!
If you want to fully open the server, you must proceed as follows:
1. Removing the side cover
2. Removing the door
3. Removing control panel trim plate
A26361-K632-Z100-1-7619 43
Page 52
System expansions for tower server Opening the server
Removing the side cover
2
1
Ê Remove the knurled screw (1) and push the side cover forward as far as it will go (2).
1
2
Ê Fold out the housing side cover in the direction of the arrow (1) and remove it (2). Ê If you wish to install or remove an accessible drive in the center or upper slot, then also remove
the right-hand housing side cover in the same manner. However, remove the door beforehand.
44 A26361-K632-Z100-1-7619
Page 53
Opening the server System expansions for tower server
Removing the door
2
3
1
1
2
2
1
Ê Open the door completely (1). Ê Lift the door slightly (2) and remove it to the front (3).
Removing control panel trim plate
To install or remove an accessible drive, first remove the control panel trim plate.
1
3
1
1
2
2
2
Ê Press down the two retaining clips of the control panel trim plate (1) and fold out the control
panel trim plate forward (2 + 3).
A26361-K632-Z100-1-7619 45
Page 54
System expansions for tower server Assembling the server

Assembling the server

Mounting control panel trim plate
If you have inserted or removed accessible drives, you must refit the control panel trim plate.
1
2
Ê Mount the control panel trim plate as shown (1 + 2). The retaining clips of the control panel trim
plate must engage in the front of the housing.
Mounting door
Ê Before mounting the door, remount the right-hand side cover if it has been removed (see
"Mounting side cover").
2
1
2
1
Ê Replace the door as shown above (1 + 2).
46 A26361-K632-Z100-1-7619
Page 55
Assembling the server System expansions for tower server
Mounting housing side cover
1
3
2
1
2
Ê Insert the housing side cover at the bottom of the server (1), push it forward as far as possible
(2) and fold it up onto the server (3).
1
2
1
2
Ê Push the side cover to the back as far as the stop (1). Ê Screw the housing side cover into place with the knurled screws removed previously (2). Ê If you have also removed the right-hand side cover, replace it by following the same procedure. Ê Plug in at the mains.
A26361-K632-Z100-1-7619 47
Page 56
System expansions for tower server SCSI hard disk drives

SCSI hard disk drives

The server can accommodate four or six carriers for 3 ½-inch hard disk drives. Each hard disk drive plug-in module can accommodate an SCSI hard disk drive with an SCA interface and a maximum height of 1.6 inches or 1 inch.
Never pull out a hard disk during operation if you are not sure that the hard disk is operated on a DAC and is part of a disk array that operated in the mode RAID Level 1 or
!
5.
If the SCSI hard disk drive is operated on a disk array controller (DAC) and belongs to a disk array operated with RAID level 1 or level 5, a defective hard disk drive can be swapped during operation (hot replace). To swap a hard disk, you need an SCSI hard disk drive with the same or higher capacity. You will identify a defective SCSI hard disk drive by a glowing orange indicator on the hard disk carrier (see "Controls and indicators"). A rebuild on the new hard disk is performed automatically after the swap, provided the DAC is correctly configured. Refer to the information in the DAC manual.
So that the storage capacity of the hard disk can be recognized at a glance when the hard disk is replaced, several prefabricated stickers with the storage capacities are provided with the server. Each hard disk (slide-in module) should bear a sticker indicating its capacity on the front. Should no suitable sticker be available, blank stickers for labeling are also provided. The stickers are color coded for easier identification.
If you want to swap several defective SCSI hard disk drives during operation, proceed as follows:
!
• Swap the first SCSI hard disk drive.
• Wait at least 60 seconds before continuing.
• Swap the next SCSI hard disk drive etc.
The SCSI-IDs of the hard disk drive plug-in modules are permanently assigned in the order 0, 1, 2, 3 or 0, 1, 2, 12, 13, 14 from bottom to top.
The following applies if SCSI hard disk drives are operated on a DAC:
RAID level 0 and 7
Rebuild is not possible. If a hard disk fails, its data is lost.
RAID level 1 and 5 without standby hard disk
Rebuild on the new disk is carried out automatically when the old disk is swapped.
RAID level 1 and 5 with standby hard disk
A standby hard disk is automatically enabled as a replacement for the defective hard disk and the data of the defective disk is rebuilt on the standby disk.
Ê Read the documentation for the new hard disk drive.
The hard disk drives which can be ordered for the server are supplied already mounted in the hard disk carriers.
A hard disk in the hard disk carrier can only be replaced by a service technician.
48 A26361-K632-Z100-1-7619
Page 57
SCSI hard disk drives System expansions for tower server

Installing a SCSI hard disk drive

If a hard disk drive is to be installed in a bay in which no hard disk drive was previously installed, then the blank insert must be removed from this bay beforehand.
1
1
2
Ê To do this, press the two tabs at the left and right on the blank insert together (1) until the
detent is released and pull the blank insert out of the bay (2).
Keep the blank insert for future use. If the hard disk drive is removed again and not replaced with a new drive, then the blank insert must be reinstalled due to cooling, the
!
applicable EMC regulations (regulations on electromagnetic compatibility) and fire protection.
1
2
1
2
Ê Push the hard disk carrier into the bay (1) as far as possible and then swing down the carrier
handle completely to enable the locking mechanism to engage (2).
A26361-K632-Z100-1-7619 49
Page 58
System expansions for tower server SCSI hard disk drives

Removing a SCSI hard disk drive

1
2
1
2
Ê Fold up the carrier handle (1) and pull on it to remove the hard disk carrier out of the installation
bay (2). If a hard disk drive has been removed and no new drive is installed in its place, then a blank insert
must be installed in the empty bay.
1
1
2
Ê Press the two tabs at the left and right on the blank insert together somewhat (1) and insert the
blank insert in the empty bay (2). Make sure that the blank insert engages properly in the bay.
50 A26361-K632-Z100-1-7619
Page 59
RemoteView chipdisk System expansions for tower server

RemoteView chipdisk

A chipdisk with installed RemoteView software is available as an option for using RemoteView on the server. The RemoteView chipdisk is equipped with an IDE interface and is installed in the server mounted on the ventilation plate.

Installing a RemoteView chipdisk

Ê Remove the left-hand side cover (see "Opening the server").
1
2c
2a
2
2b
1
Ê Unscrew the ventilation plate (1) and remove it (2).
A26361-K632-Z100-1-7619 51
Page 60
System expansions for tower server RemoteView chipdisk
1
2
Ê Screw the chipdisk onto the ventilation plate from below (1 + 2).
1
1a
1c
2
1b
2
Ê Insert the ventilation plate with the chipdisk mounted on it in the server (1) and screw it in place
(2).
Ê Connect the data line to the hard disk drive and to the IDE interface of the system board (see
Technical Manual of the system board).
Ê Connect a free power line to the chipdisk.
52 A26361-K632-Z100-1-7619
Page 61
RemoteView chipdisk System expansions for tower server
s
Ê Replace the left-hand side cover (see "Assembling the server").
So that the RemoteView chipdisk can be started automatically later, enter the chipdisk parameters in the
BIOS Setup and boot once from the chipdisk with it. Proceed as follows:
Ê Start the server and invokeBIOS Setup. Ê Enter the chipdisk parameters underHard Disk 1. Instructions are provided in the Technical
Manual for the system board or in the "BIOS Setup" manual.
Ê Save the setting and terminateBIOS Setup.
The server boots MS-DOS and RemoteView from the chipdisk.
If the RemoteView software is not yet installed on the chipdisk, install the software a described in the manual for RemoteView
i
Ê To terminate RemoteView, use the menu itemBoot Original OS.
The server boots the standard operating system. How to operate RemoteView is described in the corresponding documentation of RemoteView.

Removing a RemoteView chipdisk

Ê Remove the left-hand side cover (see "Opening the server"). Ê Disconnect the cables from the chipdisk.
1
2c
2a
2
2b
1
Ê Remove the screw (1) and take out the ventilation plate with the chipdisk mounted on it (2).
A26361-K632-Z100-1-7619 53
Page 62
System expansions for tower server RemoteView chipdisk
2
1
Ê Unscrew the chipdisk from the ventilation plate (1).
1
1a
1c
2
1b
2
Ê Insert the ventilation plate in the server again (1) and screw it into place (2). Ê Replace the left-hand side cover (see "Assembling the server").
54 A26361-K632-Z100-1-7619
Page 63
Accessible drives System expansions for tower server

Accessible drives

The server accommodates four accessible drives (three 5 ¼-inch drives and one 3 ½-inch drive). A 5 ¼-inch drive with a full installation height occupies two 5 ¼-inch half-height bays.
For error-free operation of SCSI hard drives it is important that each drive on the SCSI bus is assigned a unique SCSI-ID (0 - 6) and that the matching resistor (terminator) is only connected and enabled on the drive at the end of the SCSI cable.
As the CD-ROM drive fitted by default is connected at the end of the SCSI cable, the termination is enabled.
Ê Please read the drive documentation. Ê Assign an as yet unassigned SCSI-ID to the new drive and disable the terminating resistor.

Installing an accessible 5 ¼-inch drive

Ê Remove the control panel trim plate, the left-hand side cover and, it you wish to install an
accessible drive in the upper or middle bay, also the right-hand side cover (see "Opening the
server").
2
1
2
1
Ê If you install a half-height drive, then remove the EMC insert from the desired bay (1) and the
plastic insert from the control panel trim plate (2).
Ê If you install a DLT drive, then remove the two EMC inserts (1) and two plastic inserts from the
control panel trim plate (2).
A26361-K632-Z100-1-7619 55
Page 64
System expansions for tower server Accessible drives
2
1
2
2
a
CD ROM
The illustration shows the possible mounting points on the drive cage for the three drive types CD­ROM, DLT and Auto-Loader. For reasons of clarity, the drive cage is shown here schematically from the side. The respective mounting points are shown as filled-in circles or ovals.
1
2
DLT
Auto Loader
1
Ê If you install a half-height drive, then push it into the bay (1) and secure it on both sides with
two screws each (2).
Ê If you install a DLT drive, then place it on the carrier plate provided (a), push it with the plate
into the center and upper bay (1) and secure it on both sides with two screws each (2).
The accessible 5 ¼-inch drive in the bottom bay is only secured on the left-hand side with two knurled screws.
i
Ê Connect the cables to the drive. Ê Close the server again (see "Assembling the server").
56 A26361-K632-Z100-1-7619
Page 65
Accessible drives System expansions for tower server

Removing an accessible 5 ¼-inch drive

Ê Remove the control panel trim plate, the left-hand side cover and, if you wish to install an
accessible drive in the upper or center bay, also the right-hand side cover (see "Opening the
server").
Ê Pull the cables from the drive.
1
1
2
2
1
Ê Remove the four screws (1) and withdraw the drive from the bay (2).
1
2
Ê Place an EMC insert in the empty bay (1) and a plastic cover in the control panel trim plate (2). Ê Close the server (see "Assembling the server").
A26361-K632-Z100-1-7619 57
Page 66
System expansions for tower server Boards

Changing the floppy disk drive

Ê Remove the left-hand side cover and the control panel trim plate (see "Opening the server"). Ê Disconnect the cables from the floppy disk drive.
1
2
2
1
Ê Remove the four knurled screws (1) and withdraw the floppy disk drive from the drive carrier
(2).
1
2
Ê Push the new floppy disk drive into the bay (1) and secure it with the screws (2) you removed
earlier.
Ê Connect the cables to the floppy disk drive again. Ê Remount the control panel trim plate and the left-hand side cover (see "Assembling the
server").

Boards

Before installing or removing a board, please read the documentation supplied with the board.
58 A26361-K632-Z100-1-7619
Page 67
Boards System expansions for tower server
e
e

Installing a board

Ê Remove the left-hand side cover (see "Opening the server").
1
1
2
3
1
2
Ê Press on the mounting clip in the direction of the arrow (1) and remove it (2). Ê Remove the rear slot cover plate from the slot (3).
Do not dispose of the rear slot cover plate. For cooling, protection against fire and in ord to comply with EMC regulations, you must refit the rear slot cover plate if you remove th
!
board.
2
1
1
a
2
2
Ê Insert the board in the required slot on the system board and push it carefully into place (1).
Make sure that the rear slot cover plate of the board is positioned in the groove (a).
Ê Insert the clips for securing the board as shown (2). Ensure that the clip engages in the casing. Ê If necessary, plug the lines on the board. Ê Replace the left-hand side cover (see "Assembling the server").
A26361-K632-Z100-1-7619 59
Page 68
System expansions for tower server Power supply module

Removing a board

Ê Remove the left-hand side cover (see "Opening the server"). Ê Remove the lines connected to the board.
1
1
2
3
2
Ê Press on the clip in the direction of the arrow (1) and remove it (2). Ê Pull the board out of the slot (3).
1
1
1
2
2
2
a
Ê Insert the rear slot cover plate into the empty slot (1). Make sure that the rear slot cover plate is
positioned in the groove (a).
Ê Insert the clips for securing the rear slot cover plate as shown (2). Ensure that the clip engages
in the casing.
Ê Replace the left-hand side cover (see "Assembling the server").

Power supply module

The servers with a modular hot-plug power supply can be equipped with one or two power supply modules. With two power supply modules the servers are equipped with a redundant power supply. If one module fails, the respective other module ensures unimpaired further operation. The defective module can be replaced during operation.
60 A26361-K632-Z100-1-7619
Page 69
Power supply module System expansions for tower server
g
There are two types of hot-plug-capable power supply modules, which are easy to distinguish on the connection side (see following illustration). Both versions automatically adjust to the proper voltage range.
A server may only be equipped with one type of power supply module. Mixed equippin will cause the modules to be destroyed
!

Installing the power supply module

3
3
Ê Unscrew the screws on the lock of the blind insert (1), slide the latch upward somewhat (2),
and take out the blind insert (3).
2
1
2
1
A26361-K632-Z100-1-7619 61
Page 70
System expansions for tower server Power supply module
1
1
2
3
4
1
2
1
3
4
Ê Slide the latch on the power supply module upward somewhat (1) and insert the power supply
module in the installation bay (2).
Ê Lock the power supply module in place with the latch in the casing (3) and screw the latch in
place in this position (4).
62 A26361-K632-Z100-1-7619
Page 71
Power supply module System expansions for tower server

Removing the power supply module

3
2
1
3
2
1
Ê Unscrew the screw on the lock of the power supply module (1), slide the latch upward
somewhat (2) and pull the power supply module out of the installation bay (3).
A26361-K632-Z100-1-7619 63
Page 72
System expansions for tower server Power supply module
1
2
3
1
2
3
Ê Slide the locking slide on the blind insert upward somewhat and insert the blind insert in the
installation bay (1).
Ê Secure the blind insert with the locking slide in the housing (2) and screw it in place in this
position (3).
64 A26361-K632-Z100-1-7619
Page 73
Exchanging the fan System expansions for tower server

Exchanging the fan

The two server fans can easily be replaced during servicing.
Ê Remove the left-hand side cover (see "Opening the server").
1
1
1
2
2
2
3
4
Ê Pull the connecting cable off the fan (1), press on the retaining clips (2) and take out the fan to
the side (3 + 4).
1
1
2
3
1
2
2
Ê Place the new fan in the bay (1). When doing so, make sure the fan retaining clips engage
properly (2).
Ê Connect the cable to the fan (3). Ê Replace the left-hand side cover (see "Assembling the server").
A26361-K632-Z100-1-7619 65
Page 74
System expansions for tower server Extensions on the system board

Extensions on the system board

Details of how you upgrade the main memory of the server, replace the lithium battery or processor or make certain settings are provided in the Technical Manual of the system board.
Ê Remove the left-hand side cover (see "Opening the server"). Ê Remove the ventilation plate (see "RemoteView chipdisk"). Ê Make the desired expansions or settings (see the Technical Manual for the system board). Ê Install the ventilation plate again (see "RemoteView chipdisk"). Ê Replace the left-hand side cover (see "Assembling the server").
66 A26361-K632-Z100-1-7619
Page 75

System expansions for rack server

e
a
Because the internal design of tower servers and rack servers is identical, this chapter only covers the activities which differ from those for the tower server. These include opening and closing the server and the installation and removal of accessible drives. On the other hand, please read the corresponding chapters in "System expansions for tower server" when you wish to carry out the following work:
• Installing and removing SCSI hard disk drives
• Installing/removing a RemoteView hard disk drive
• Installing and removing boards
• Exchanging the fan
• Installing extensions on the system board
• Installing and removing the power supply module
You will find an overview and a brief description of the installed system boards in th server lid.
i
A detailed description of the system board is provided in the corresponding Technic Manual.

Opening the server

Please take note of the safety information in the chapter"Important notes".
!
Ê Switch the server off.
Pull all power plugs out of the power outlets
!
Ê If the SCSI cables of the server are routed in a limited cable guide, then remove the SCSI
cables from the rack cable guides (see "Mounting cable guides and routing cables"inthe section "Installing the rack server").
A26361-K632-Z100-1-7619 67
Page 76
System expansions for rack server Opening the server
1
2
Ê Release the four knurled screws (1) and withdraw the server from the rack as far as it will go
(2). The slide stops of the extending rails left and right must engage.
2
1
Ê Remove the knurled screw behind the front panel (1) and push the cover forward as far as
possible (2).
2
1
Ê Lift the cover on the right-hand side (1) and remove it (2).
68 A26361-K632-Z100-1-7619
Page 77
Assembling the server System expansions for rack server
If you wish to install or remove accessible drives, then also remove the control panel trim plate.
1
1
2
1
3
Ê Press the two retaining clips of the control panel trim plate behind the front panel firmly
downward (1), fold out the control panel trim plate (2) and remove it (3).

Assembling the server

If you have inserted or removed an accessible drive, you must refit the control panel trim plate.
1
2
Ê If you have installed an accessible drive, then remove the corresponding plastic trim plate from
the control panel trim plate (1).
Ê If you have removed an accessible drive, then remount the corresponding plastic trim plate in
the control panel trim plate (2).
A26361-K632-Z100-1-7619 69
Page 78
System expansions for rack server Assembling the server
1
2
Ê Mount the control panel trim plate as shown (1 + 2). Make sure that the retaining clips of the
control panel trim plate engage in the front panel.
1
3
2
Ê Insert the cover in the casing on the left-hand side (1), slide it forward as far as possible (2) and
fold it onto the casing at the right (3).
1
2
Ê Slide the cover back as far as possible (1) and screw it in place with the knurled screw behind
the front panel (2).
70 A26361-K632-Z100-1-7619
Page 79
Assembling the server System expansions for rack server
1
2
Ê Press the locking spring (1) on both sides and push the server back into the rack (2).
1
Ê Secure the server in the rack (1) using the four knurled screws. Ê If the cables of the server are laid in a limited cable guide, place the SCSI cables back in the
cable guides (see "Mounting cable guides and routing cables" section "Installing the rack
server").
Ê Plug in the power plug again.
A26361-K632-Z100-1-7619 71
Page 80
System expansions for rack server Accessible drives

Accessible drives

The server accommodates four accessible drives (three 5 ¼-inch drives and one 3 ½-inch drive). A 5 ¼-inch drive with a full installation height occupies two 5 ¼-inch half-height bays.
For error-free operation of SCSI hard drives it is important that each drive on the SCSI bus is assigned a unique SCSI-ID (0 - 6) and that the matching resistor (terminator) is only connected and enabled on the drive at the end of the SCSI cable.
As the CD-ROM drive fitted by default is connected at the end of the SCSI cable, the termination is enabled.
Ê Read the documentation supplied with the drive and make the required settings (SCSI ID,
termination) at the drive.

Installing an accessible 5 ¼-inch drive

Ê Open the server (see "Opening the server"). Ê Pull the cables from the installed accessible drives.
1
2
Ê Remove the four screws (1) and pull out the drive cage (2).
72 A26361-K632-Z100-1-7619
Page 81
Accessible drives System expansions for rack server
3
1
2
3
4
6
5
1
6
4
CD ROM DLT
The illustration shows the possible mounting points on the drive cage for the three drive types CD­ROM, DLT and Auto-Loader. For reasons of clarity, the drive cage is shown here schematically from the side. The respective mounting points are shown as filled-in circles or ovals.
Auto Loader
Ê If you install a half-height drive, then remove the EMC cover from the corresponding bay (1),
insert the drive in this bay (2) and secure it on both sides of the drive cage with two screws (3).
Ê If you install a DLT drive, then remove the EMC covers from the two upper bays (1), insert the
drive on the carrier plate provided (4), insert it in the drive cage with the plate (5) and secure it on both sides of the drive cage with two screws (6).
A26361-K632-Z100-1-7619 73
Page 82
System expansions for rack server Accessible drives
2
1
Ê Insert the drive cage into the server (1) and fasten it using the screws you removed earlier (2). Ê Connect the cables to the drives. Ê Close the server (see "Assembling the server").

Removing an accessible 5 ¼-inch drive

Ê Open the server (see "Opening the server"). Ê Pull the cables from the drives.
1
2
Ê Remove the four screws (1) and withdraw the drive cage (2).
74 A26361-K632-Z100-1-7619
Page 83
Accessible drives System expansions for rack server
1
2
3
1
Ê Remove the four screws (1) and withdraw the drive from the drive cage (2). Ê Insert an EMC cover (3).
2
1
Ê Insert the drive cage into the server (1) and fasten it using the screws you removed earlier (2). Ê Connect the cables to the remaining floppy disk drive. Ê Close the server (see "Assembling the server").
A26361-K632-Z100-1-7619 75
Page 84
System expansions for rack server Accessible drives

Changing the floppy disk drive

Ê Open the server (see "Opening the server"). Ê Disconnect the cables from the floppy disk drive.
1
2
Ê Remove the two screws (1) and withdraw the floppy disk drive from the bay (2).
2
1
Ê Push the new floppy disk drive into the bay (1) and secure it with the two screws (2). Ê Connect the cables to the floppy disk drive again. Ê Close the server (see "Assembling the server").
76 A26361-K632-Z100-1-7619
Page 85

Technical data

:
V
z
:
r
d
/
A
V
A
:
r
d
t
t
/
A
V
A
/
A
V
A
/
A
V
A
:
5
0
0
g
g
2
2
3
2
:
)
)
C
C
L
l
L
Electrical data
Rated voltage range Frequency: 50 Hz - 60 H Rated current in basic configuration
• Server without monitor outlet or monito
outlet is not use
Max. rated current
• Server without monitor outlet or monito
outlet is not use
• Server with monitor socke
• Monitor socke
Protection class: I Regulations complied with
Dimensions of tower server (including door and feet)
Width: Depth: Height: Weight:
Dimensions of rack server (including rails and installed in rack)
Width: Depth: Height: Weight:
Environmental conditions
Environment class 3K Environment class 2K
Temperature
• Operating (3K2
• Transport (2K2
Condensation in operating must be avoided.
100V-125V/200V-240
100 V - 125 V 200 V - 240
100 V - 125 V 200 V - 240
100 V - 125 V 200 V - 240
100 V - 125 V 200 V - 240
EN 60950 / VDE 080 UL 195 CSA 22.2 No 95
288 mm 685 mm 480 mm approx. 18 - 35 k
483 mm 754 mm 266 mm approx. 18 - 35 k
DIN IEC 721 part 3­DIN IEC 721 part 3-
15 °C .... 35 °
-25 °C .... 60 °
1,8 1,0
6,0 3,5
9,0 5,0
3.0 1,5
Noise level
Sound power level Sound pressure leve
at bystander position
A26361-K632-Z100-1-7619 77
(ISO 9296): ≤ 5.8 dB
WAd
pAm (ISO 9296):
≤ 43 dB
Page 86
Page 87

Index

5
5 1/4-inch drive
installing 55, 72 removing 57, 74
A
Accessible drive 55, 72
installing 55, 72 removing 57, 74
ASR&R 2
B
Battery, replacing 66 BIOS Setup
preventing calling 37
write protection 37 BIOS Update 2 BIOS, protecting boards with own BIOS 37 Blank insert
inserting 50
removing 49 Board 58
installing 59
removing 60
safety 6
C
Cable
connecting 11
disconnecting 11 Cable laying, limited 23 Cable routing
unlimited 21
with cable chain 21 CD-ROM drive
indicator 31
installing 55, 72
removing 57, 74 CE certificate 6 Chipcard reader
indicator 31 Chipdisk 51
installing 51
removing 53 Class A Compliance Statement 7 Cleaning
keyboard 35
monitor 35
A26361-K632-Z100-1-7619 79
Page 88
Index
server 35
Closing
server 46, 69
Configuration
server 33 Connecting, server 13 Control panel trim plate
mounting 46
removing 45 Controls 29 Courier 3
D
DAC
defective drive 42 DAC960 33 DACCF 33 Data
electrical 77
technical 77 Data protection 37 Data, environmental 77 Date, not correct 41 Defective drive 42 Devices
connecting 13, 24
interface 13 Dimensions 77 Disk Array Controller 1, 48 Display, cleaning 35 Disposal and recycling 10 DLT drive, installing 55, 72 Door
mounting 46
removing 45 Drive
changing floppy disk drive 58, 76
defective 42
indicator 31
installing accessible 5 1/4-inch drive 55, 72
installing SCSI hard disk drive 48
removing accessible 5 1/4-inch drive 57, 74
removing SCSI hard disk drive 48
reported as dead 42 Drive error, indicator 31 Drive LEDs 31
E
EDC 2 Electrical data 77 Electromagnetic compatibility 6 EMC 6 Environmental class 77 Environmental conditions 77
80 A26361-K632-Z100-1-7619
Page 89
Environmental data 77 Error
drive defect 42 drive reported as dead 42 flickering screen 40 floppy disk cannot be read/written 41 message on the screen 42 no mouse pointer 41 screen 39 screen display drifts 40 server 39 server switches itself off 39 system does not boot 41 time 41
wrong date 41 ESD 6 Extending unit 18 Extensions, system board 66 External devices
connecting 13
ports 13
F
Fan, exchanging 65 FCC statement 7 Features 1 Flickering stripes on the monitor screen 40 Floppy disk drive
changing 58, 76
indicator 31
write-protection 37 Floppy disk, cannot be read or written 41 Further information 1
Index
G
General information 1 Guarantee coupon booklet 11
H
Hard disk drive
indicator 31
installing 48
removing 48 Hard disk subsystem 1 Height module 17 Hot replace 1, 48 Hot-plug power supply 16, 26 Housing side cover, mounting 47
I
ICU 33 IDE interface 51 Important notes 5 Indicator, remains blank 39
A26361-K632-Z100-1-7619 81
Page 90
Index
Indicators 29
CD-ROM drive 31 chipcard reader active 31 drive active 31 drive error 31 floppy disk drive active 31 hard disk drive active 31 power-on indicator 31
power-on indicator fails to light 39 Information, general 1 Installation 11 Installing
5 1/4-inch drive 55, 72
board 59
fan 65
power supply module 61
rack server 17
RemoteView chipdisk 51
tower server 12 Interfaces 13, 24 ISA configuration 33 Italics 3
K
Keyboard
cleaning 35
connecting 12
keyboard port 13
L
LED 29 Limited cable routing 23 Line voltage range 25 Lithium battery, changing 66 Locking, server 34
M
Main memory, upgrading 66 Main switch 31 Memory scrubbing 2 Message, error 42 Modular power supply 16, 26 Monitor
connecting to power voltage 14
drifting display 40
error message 42
monitor port 13 Mounting assembly kit, rack server 17 Mouse
cleaning 35
no mouse pointer 41
PS/2 port 13 Mouse pointer, not dislayed 41
82 A26361-K632-Z100-1-7619
Page 91
N
Noise level 77 Notational conventions 3 Note, power cord selection 8 Notes
CE certificate 6 disposal and recycling 10 safety 5
Novell Netware 3.12 33
O
ON/OFF switch 31 Onboard SCSI controller
configuring 33 Opening, server 43, 67 Operating system
not starting 41
preventing start 37 Overview
ports and slots 24
server 1
P
Packing material 11 Parallel port 13 PDA technology 2 Ports 13, 24 Power cord selection 8 Power supply
hot-plug 26
modular 16, 26
redundant 25
standard 14, 25 Power supply module 60
installing 61
removing 63 Power voltage, connecting to 14, 25 Power-on
preventing 37 Power-on indicator 31
doesn't fail to light 39 Processor, upgrading 66 Property protection 37 Protection, theft 37 PS/2 keyboard port 13 PS/2 mouse port 13
Index
R
Rack Architect 17 Rack server
connecting 24
connectors 24
extending unit 18
inserting 17
A26361-K632-Z100-1-7619 83
Page 92
Index
installation steps 17 installing 17 mounting assembly kit 17
system expansions 67 RAID level 2, 48 Ready-to-operate 32 Recycling 10 Redundant power supply 14, 25 Remote power-on, preventing 37 Remote Test and Diagnosis System 51 RemoteView chipdisk 51
installing 51
removing 53 Removing
5 1/4-inch accessible drive 57
board 60
fan 65
Power supply module 63
RemoteView chipdisk 53
SCSI hard disk drive 50 RTDS 2
S
Safety 5
board 6 SCA interface 1, 48 SCO UNIX 33 Screen
flickering 40 SCSI hard disk drive
installing 48, 49
removing: 48, 50 SCSI ID, accessible drives 55, 72 SCU 33 Security function, BIOS Setup 37 Security measures 37 Security standards 77 Select, power cord 8 Serial port 13 Server
opening 43
switches itself off 39 Server management 2 ServerStart 2, 33 ServerView 2 Service compartment, tower server 35 Side cover
removing 44 Standard power supply 14, 25 Stand-by 32 Summer time 41 Surface 77 Switch 29 Switch off by program
prevent 37
84 A26361-K632-Z100-1-7619
Page 93
Switching off, server 31 Switching on, server 31 Symbols, explanation of 3 System board 1
extensions 66 System LEDs 31 System startup, preventing 37 Systemexpansions
rack server 67
tower server 43
T
Technical data 77 Temperature 77 Terminating resistor, accessible drive 55, 72 Termination 55, 72 Time, not correct 41 Tower server
installing 12
locking 34
service compartment 35
system expansions 43
unlocking 27 Transport 10 Trouble
drive defect 42
drive reported as dead 42
flickering screen 40
floppy disk cannot be read/written 41
message on the screen 42
no mouse pointer 41
screen 39
screen display drifts 40
server 39
server switches itself off 39
system does not boot 41 Troubleshooting and tips 39
Index
U
Ultra-Wide-SCSI controller 48 Unlimited cable routing 21 Unlocking, tower server 27
W
Weight 77 Winter time 41 Write protection
BIOS Setup 37
floppy disk drive 37 Wrong date 41 Wrong time 41
A26361-K632-Z100-1-7619 85
Page 94
Information on this document
On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu­ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So­lutions.
This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.
Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.
Contact and support addresses will now be offered by Fujitsu Technology So­lutions and have the format …@ts.fujitsu.com.
The Internet pages of Fujitsu Technology Solutions are available at
http://ts.fujitsu.com/...
and the user documentation at http://manuals.ts.fujitsu.com.
Copyright Fujitsu Technology Solutions, 2009
Hinweise zum vorliegenden Dokument
Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit­dem den Namen Fujitsu Technology Solutions.
Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.
Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.
Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.
Die Internetseiten von Fujitsu Technology Solutions finden Sie unter
http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die
Benutzerdokumentation.
Copyright Fujitsu Technology Solutions, 2009
Loading...