Fujitsu Inverter Halcyon ASU24RL, AOU24RL Operating Manual

24,200 BTU/h
2,31
kW ,
1 A
27,600 BTU/h
2,47 kW
24,200 BTU/h
2,31
kW
,
1 A
27,600 BTU/h
2,47 kW
,
8 A
24,200 BTU/h
2.31 kW
27,600 BTU/h
2.47 kW
INDOOR UNIT UNIDAD INTERIOR UNITÉ INTÉRIEURE
OUTDOOR UNIT UNIDAD EXTERIOR UNITÉ EXTÉRIEURE
ASU24RL
AOU24RL
En-2
FEATURES AND FUNCTIONS
INVERTER
At the start of operation, a large power is used to bring the room quickly to the desired temperature. Afterwards, the unit automatically switches to a low power setting for eco­nomic and comfortable operation.
COIL DRY OPERATION
The Indoor unit can be dried by pressing the COIL DRY but­ton on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium.
AUTO CHANGEOVER
The operation mode (cooling, dry, heating) is switched au­tomatically to maintain the set temperature, and the tem­perature is kept constant at all times.
PROGRAM TIMER
The program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour pe­riod.
SLEEP TIMER
When the SLEEP button is pressed during Heating mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during cooling mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automati­cally turns off.
WIRELESS REMOTE CONTROL UNIT
The Wireless Remote Control Unit allows convenient con­trol of air conditioner operation.
HORIZONTAL AIRFLOW: COOLING/ DOWNWARD AIRFLOW: HEATING
For cooling, use horizontal airflow so the cool air does not blow directly on the occupants in the room. For heating, use downward airflow to send powerful, warm air to the floor and create a comfortable environment.
OMNI-DIRECTIONAL AIR FLOW (SWING OPERATION)
Three-dimensional control over air direction swing is possi­ble through dual use of both an UP/DOWN air direction swing and RIGHT/LEFT air direction swing. Since UP/DOWN air direction flaps operate automatically according to the oper­ating mode of the unit, it is possible to set air direction based on the operating mode.
REMOVABLE OPEN PANEL
The indoor unit’s Open Panel can be removed for easy clean­ing and maintenance.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.
SUPER QUIET OPERATION
When the FAN CONTROL button is used to select QUIET, the unit begins super-quiet operation; the indoor unit’s air­flow is reduced to produce quieter operation.
POLYPHENOL CATECHIN AIR CLEANING FILTER
The polyphenol catechin air cleaning filter uses static elec­tricity to clean the air of fine particles and dust such as to­bacco smoke and plant pollen that are too small to see. The filter contains catechin, which is highly effective against various bacteria by suppressing the growth of the bacteria adsorbed by the filter. Note that when the air cleaning filter is installed, the amount of air produced decreases, causing a slight decrease in the air conditioner's performance.
NEGATIVE AIR IONS DEODORIZING FILTER
It comprises pottery super micro particles, which can pro­duce negative air ions having the effect of deodorizing and can absorb and remit the peculiar smell at home.
En-3
Fig. 6 Remote Control Unit
J SLEEP button K MASTER CONTROL button L SET TEMP. button (
/ )
M COIL DRY button N Signal Transmitter O TIMER MODE button P TIMER SET (
/ ) button
Q FAN CONTROL button R START/STOP button S SET button (Vertical) T SET button (Horizontal) U SWING button V RESET button W TEST RUN button
This button is used when installing the conditioner, and should not be used un­der normal conditions, as it will cause the air conditioner’s thermostat function to op­erate incorrectly.
If this button is pressed during normal op­eration, the unit will switch to test opera­tion mode, and the Indoor Unit’s OPERA­TION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously.
To stop the test operation mode, press the START/STOP button to stop the air condi­tioner.
X CLOCK ADJUST button Y Remote Control Unit Display (Fig. 7) Z Transmit Indicator [ Clock Display \ Operating Mode Display ] Timer Mode Display ` Fan Speed Display a Temperature SET Display b COIL DRY Display c SLEEP Display d SWING Display
NAME OF PARTS
Refer to the folded out page on the cover.
Fig. 1 Indoor Unit
1 Operating Control Panel (Fig. 2) 2 MANUAL AUTO button
When kept on pressing the MANUAL AUTO button for more than 10 seconds, the forced cooling operation will start.
The forced cooling operation is used at the
time of installation. Only for authorized service personnel's use.
When the forced cooling operation starts
by any chance, press the START/STOP but­ton to stop the operation.
3 Indicator (Fig. 3) 4 Remote Control Signal Receiver 5 OPERATION Indicator Lamp (red) 6 TIMER Indicator Lamp (green)
If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See Page 14 Auto Restart).
7 COIL DRY Indicator Lamp (orange)
8 Intake Grille (Fig. 4) 9 Front Panel 0 Air Filter A Air Flow Direction Louver B Power Diffuser C Right-Left Louver
(behind Air Flow Direction Louver)
D Drain Hose E Air Cleaning Filter
Fig. 5 Outdoor Unit
F Intake Port G Outlet Port H Pipe Unit I Drain port (bottom)
Loading...
+ 13 hidden pages