Fujitsu D2440, D2932 Technical Manual

Page 1
System Board D2440/D2932 for RX330 S1
Technical Manual
Edition June 2009
Page 2
CommentsSuggestions… Corrections…
Feel free to send us your comments by e-mail to
manuals@
ts.fujtsu.com.
Certified documentation according to DIN EN ISO 9001:2000
To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademarks
Copyright © 2009 Fujitsu Technology Solutions GmbH.
All rights reserved. Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.
Page 3
D2440/D2932 (RX330 S1) Technical Manual
Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Important notes . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Notes on safety . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 CE certificate . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.3 Environmental protection . . . . . . . . . . . . . . . . . . . 11
3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.2 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.3 PCI bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.4 Screen resolution . . . . . . . . . . . . . . . . . . . . . . . 19
3.5 Temperature / system monitoring . . . . . . . . . . . . . . . 19
3.6 Connectors and DIP switches . . . . . . . . . . . . . . . . . 21
3.6.1 External connectors . . . . . . . . . . . . . . . . . . . . . . . 23
4 Replacing the lithium battery . . . . . . . . . . . . . . . . . 25
Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Page 4
Page 5
D2440/D2932 (RX330 S1) Technical Manual 5
1 Introduction
This technical manual describes the system boards D2440/D2932, which can be equipped with one or two AMD
®
processors.
Further information about drivers is provided in the readme files on the hard disk, on the supplied CDs or DVDs.
You will find further information in the BIOS description.
Notational conventions
The meanings of the symbols and fonts used in this manual are as follows:
italics indicates commands, menu items, file and path
names or software programs
fixed font indicate system output on the monitor
semi-bold fixed font
indicates values to be entered through the keyboard
[Key symbol] indicates keys according to their representation on the
keyboard
If capital letters are to be entered explicitly, then the Shift key is shown, e.g. [SHIFT] - [A] for A.
If two keys need to be pressed at the same time, then this is shown by placing a hyphen between the two key symbols.
“quotation marks” indicates names and terms that are being empha-
sized.
Ê indicates an operation that to be performed
V CAUTION! indicates warnings, which, if ignored, will endanger
your health, destroy the system or lead to the loss of data.
I indicates additional information, notes and tips
Table 1: Notational conventions
Page 6
Page 7
D2440/D2932 (RX330 S1) Technical Manual 7
2 Important notes
In this chapter you will find essential information regarding safety when working with your server.
V CAUTION!
With the system board installed you must open the system to access the system board. How to access the system board of your system is described in the appropriate service supplement.
When handling the system board, refer to the specific notes on safety in the operating manual and/or service supplement for the respective server.
2.1 Notes on safety
V CAUTION!
The actions described in these instructions should only be performed
by authorized, qualified personnel. Equipment repairs should only be performed by qualified staff. Any failure to observe the guidelines in this manual, and any unauthorized openings and improper repairs could expose the user to risks (electric shock, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability.
Transport the device only in the antistatic original packaging or in
packaging that protects it from knocks and jolts.
Only install expansions that are allowed for the system board. If you
install other expansions, you may damage the requirements and rules governing safety and electromagnetic compatibility or your system. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet.
The warranty expires if the device is damaged during the installation
or replacement of system expansions.
Page 8
8 Technical Manual D2440/D2932 (RX330 S1)
Notes on safety Important notes
V Components can become very hot during operation. Ensure you do
not touch components when making extensions to the system board. There is a danger of burns!
Transmission lines to peripheral devices must be adequately
shielded.
To the LAN wiring the requirements apply in accordance with the
standards EN 50173 and EN 50174-1/2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC 11801 are to be considered.
Never connect or disconnect data transmission lines during a storm
(lightning hazard).
Batteries
V CAUTION!
Incorrect replacement of lithium battery may lead to a risk of
explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer.
It is essential to observe the instructions in chapter “Replacing the
lithium battery”.
Page 9
D2440/D2932 (RX330 S1) Technical Manual 9
Important notes Notes on safety
Modules with electrostatic-sensitive components
Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label:
Figure 1: ESD label
When you handle components fitted with ESDs, you must observe the following points under all circumstances:
You must always discharge yourself of static charges (e.g. by touching a
grounded object) before working.
The equipment and tools you use must be free of static charges.
Remove the power plug from the power socket before inserting or removing
boards containing ESDs.
Always hold boards with ESDs by their edges.
Never touch pins or conductors on boards fitted with ESDs.
Use a grounding cable designed for this purpose to connect yourself to the
system unit as you install/remove the board.
Place all components on a static-safe base.
I You will find a detailed description for handling ESD components in the
relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).
Page 10
10 Technical Manual D2440/D2932 (RX330 S1)
CE certificate Important notes
Notes about boards
During installation/deinstallation of the system board, observe the specific
instructions described in the service manual for the server.
Remove the plug from the mains outlet so that system and system board are
totally disconnected from the mains voltage.
To prevent damage to the system board, the components and conductors on
it, please take great care when you insert or remove boards. Take great care to ensure that extension boards are slotted in straight, without damaging components or conductors on the system board, or any other components, for example EMI spring contacts
Be careful with the locking mechanisms (catches, centring pins etc.) when
you replace the system board or components on it, for example memory modules or processors.
Never use sharp objects (screwdrivers) for leverage.
2.2 CE certificate
The shipped version of this board complies with the requirements of the EEC directive 89/336/EEC „Electromagnetic compatibility“.
Compliance was tested in a typical PRIMERGY configuration.
Page 11
D2440/D2932 (RX330 S1) Technical Manual 11
Important notes Environmental protection
2.3 Environmental protection
Environmentally friendly product design and development
This product has been designed in accordance with standards for ”environmen­tally friendly product design and development“. This means that the designers have taken into account important criteria such as durability, selection of materials and coding, emissions, packaging, the ease with which the product can be dismantled and the extent to which it can be recycled.
This saves resources and thus reduces the harm done to the environment.
Notes on saving energy
Devices that do not have to be on permanently should not be switched on until they need to be used and should be switched off during long breaks and on completion of work.
Notes on packaging
Please do not throw away the packaging. We recommend that you do not throw away the original packaging in case you need it later for transporting.
Notes on dealing with consumables
Please dispose batteries in accordance with local government regulations.
Do not throw batteries and accumulators into the household waste. They must be disposed of in accordance with local regulations concerning special waste.
All batteries containing pollutants are marked with a symbol (a crossed-out rubbish bin on wheels). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant:
Cd Cadmium Hg Mercury Pb Lead
Notes on labeling plastic housing parts
Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them.
Page 12
12 Technical Manual D2440/D2932 (RX330 S1)
Environmental protection Important notes
Returning, recycling and disposal
For details on returning and reuse of devices and consumables within Europe, refer to the “Returning used devices” manual, or contact your Fujitsu
Technology
Solutions branch office/subsidiary or our recycling centre in Paderborn:
Fujitsu
Technology Solutions
Recycling Center D-33106 Paderborn
Tel. +49 5251 8 18010
Fax +49 5251 8 18015
The device may not be disposed of with household rubbish. This appliance is labelled in accordance with European Directive 2002/96/EC concerning used electrical and electronic appliances (waste electrical and electronic equipment - WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU. To return your used device, please use the return and collection systems available to you. You will find further information on this at http://ts.fujitsu.com/recycling.
Page 13
D2440/D2932 (RX330 S1) Technical Manual 13
3 Features
For the PRIMERGY RX330 S1 server the system boards D2440 and D2932 are available. The system boards differ in Firmware, processors and main memory.
3.1 Overview
Processors
Main memory
Chip sets on the system board
HT1000 (South bridge) – HT2100 (North bridge) – LSI 1068 SAS RAID controller – iRMC with integrated graphic controller
D2440 D2932
–2 x AMD64
®
Opteron™ Dual Core or Quad Core („Barcelona“) processors
2 processor sockets F (1207) – integrated Memory Controller – AMD PowerNow!™ Technology
with Optimized Power Management (OPM)
2 x Opteron™ Quad Core
(„Shanghai“) processors – 2 processor sockets F (1207) – integrated Memory Controller – AMD PowerNow!™ Technology
with Optimized Power
Management (OPM)
D2440 D2932
8 slots for main memory
ECC DDR2-533 (PC4300) or ECC DDR2-667 (PC5300) SDRAM memory modules with 512 MB, 1Gbyte, 2 Gbyte and
4Gbyte – maximum 32 Gbyte of memory – ECC multiple bit error detection
8 slots for main memory
ECC DDR2-800 (PC6400) SDRAM memory modules with
1 Gbyte, 2 Gbyte and 4Gbyte – maximum 32 Gbyte of memory – ECC multiple bit error detection
Page 14
14 Technical Manual D2440/D2932 (RX330 S1)
Overview Features
Broadcom 5715 Dual Gbit LAN controller – Onboard Super I/O controller PC87417
Internal connectors
IDE primary connector – 6 SAS connectors – SATA connector – USB connector – front panel connector – ATX power connector – 2 CPU(12V) power connectors – fan1-3 Sys connector –I
2
C connector (PSU) – 2 hard disk signaling connectors – IDTEMP connector – safety switch connector – battery holder
External connectors
2 serial ports (COM1, COM2) – 2 PS/2 interfaces for keyboard and mouse – 2 USB 2.0 ports – VGA port – 2 RJ45 LAN ports – Service LAN port
PCI slots
slot for riser card – PCI Express x8 slot
BIOS features
Phoenix-BIOS (Trusted Core)
Form factor
304.8 mm x 330.2 mm
Page 15
D2440/D2932 (RX330 S1) Technical Manual 15
Features Main memory
3.2 Main memory
The system board supports up to 32 Gbyte main memory. 8 slots (4 banks with 2 modules) are available for the main memory. Each memory bank can be populated with 512 Mbyte (only D2440), 1 Gbyte, 2 Gbyte or 4 Gbyte ECC DDR2 SDRAM memory modules.The maximum main memory is 16 Gbyte for installation with one CPU and 32 GByte with two CPUs.
ECC with memory scrubbing is supported.
I You will find the descriptions how to install memory modules in the
Options Guide of your server.
Module population
Figure 2: Main memory
If the memory modules are populated in pairs, each pair must consist of
identical memory modules (2-way interleaved mode)
The module capacity between pairs can differ: pair 2A/2B can be populated
with two 1 GMbyte modules and pair 1A/1B with two 2 Gbyte modules.
CPU 2 must be installed to access DIMM3A/3B and DIMM4A/4B.
D2440 ECC DDR2-533 (PC4300) or ECC DDR2-667 (PC5300)
D2932 ECC DDR2-800 (PC6400)
CPU 1
DIMM1B DIMM1A DIMM2B DIMM2A
DIMM4A DIMM4B DIMM3A DIMM3B
CPU 2
Page 16
16 Technical Manual D2440/D2932 (RX330 S1)
PCI bus Features
Following table shows the mandatory population order:
3.3 PCI bus
Figure 3: PCI slots
PCI slots
The following table shows an overview of the PCI slots:
DIMM 2ADIMM 2BDIMM 1ADIMM
1B
2
DIMMs
empty empty popu-
lated
popu-
lated
4
DIMMs
popu-
lated
popu-
lated
popu-
lated
popu-
lated
CPU 1
DIMM 2ADIMM 2BDIMM 1ADIMM 1BDIMM 4ADIMM 4BDIMM 3ADIMM
3B
4
DIMMs
empty empty popu-
lated
popu-
lated
empty empty popu-
lated
popu-
lated
8
DIMMs
popu-
lated
popu-
lated
popu-
lated
popu-
lated
popu-
lated
popu-
lated
popu-
lated
popu-
lated
CPU 1 CPU 2
PCI slot Description
1 PCI Express x8 slot
2-4 Slots on riser card 1 or 2
PCI Express x8
Page 17
D2440/D2932 (RX330 S1) Technical Manual 17
Features PCI bus
Slots on riser card 1:
Slots on riser card 2:
Zero Channel RAID
PCI-X slot 2 is prepared for the operation of a Zero Channel RAID (ZCR) controller. Such a ZCR controller has no ports for hard disk drives. Installing the ZCR controller in this PCI-X slot upgrades the SAS controller on the system board to a fully featured RAID controller. Without this upgrade the SAS controller on the system board supports only RAID 0 and RAID 1 configurations.
PCI, PCI-X, PCI Express interrupts
Each device connected to a PCI bus, a PCI-X bus or PCI Express can use up to four interrupt signals depending on the functionality.
PCI and PCI-X buses use four lines named INTA to INTD, typically connected to all devices on the bus in order to periodically balance interrupt load. An interrupt signal may thereby be used simultaneously by multiple devices (interrupt sharing).
PCI Express devices send their interrupts through messages. This avoids restrictions in wiring.
PCI slot Description
4 PCI Express x8 slot
3 PCI-X slot (66 MHz)
2 PCI-X slot (66 MHz) inclusive ZCR (option)
PCI slot Description
4 PCI Express x8 slot
3 PCI Express x4 slot
2 PCI-X slot (66 MHz) inclusive ZCR (option)
Page 18
18 Technical Manual D2440/D2932 (RX330 S1)
PCI bus Features
The following interrupt signals are used in the system depending on the installed riser card (1 or 2) and the use of a ZCR controller:
With riser card 1:
With riser card 2:
If a ZCR controller has been installed in slot 2, the LSI1068-Controller is hidden in the device list and its interrupt signal goes no longer directly to the system.
Assignment of the PCI interrupts
If you select Auto in the BIOS setup, the interrupts are assigned automatically and no further settings are required.
Slot/device Property Interrupt signal
VGA iRMC graphic PCI-INTA
LSI 1068 PCI-X SAS controller PCI-X-INTC
LAN BCM5715 Dual Channel
Slot 4 PCIe x8
Slot 3 PCI-X (66 MHz) PCI-X-INTD, PCI-X-INTA, PCI-X-INTB,
PCI-X-INTC
Slot 2 PCI-X (66 MHz) inclusive ZCR PCI-X-INTA, PCI-X-INTB, PCI-X-INTC,
PCI-X-INTD
Slot 1 PCIe x8
Slot/device Property Interrupt signal
VGA iRMC graphic PCI-INTA
LSI 1068 PCI-X SAS controller PCI-X-INTC
LAN BCM5715 Dual Channel
Slot 4 PCIe x8
Slot 3 PCIe x4
Slot 2 PCI-X (66 MHz) inclusive ZCR PCI-X-INTA, PCI-X-INTB, PCI-X-INTC,
PCI-X-INTD
Slot 1 PCIe x8
Page 19
D2440/D2932 (RX330 S1) Technical Manual 19
Features Screen resolution
3.4 Screen resolution
Depending on the operating system used the screen resolutions in the following table refer to the Matrox graphic controller on the system board. The Matrox graphic controller is integrated in the iRMC (integrated Remote Management Controller).
If you are using an external graphic controller, you will find details of supported screen resolutions in the operating manual or technical manual supplied with the graphic controller.
3.5 Temperature / system monitoring
Temperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating. In addition, any unnecessary noise is also prevented by reducing the fan speed, and information is provided about the system status.
The temperature and system monitoring is controlled by an onboard controller.
The following functions are supported:
Temperature monitoring
Measurement of the processor temperature, the system board temperature by an onboard sensor and measurement of the ambient temperature by a temperature sensor.
Fan monitoring
Fans that are no longer available, blocked or sticky fans are detected.
Screen resolution Supported colors
640x480 8 bit, 16 bit, 24 bit
800x600 16 bit, 24 bit
1024x768 16 bit
1152x864 8 bit
1280x1024 8 bit
Page 20
20 Technical Manual D2440/D2932 (RX330 S1)
Temperature / system monitoring Features
Fan control
The fans are controlled according to temperature.
Sensor monitoring
The removal of, or a fault in, a temperature sensor is detected. Should this happen all fans monitored by this sensor run at maximum speed, to achieve the greatest possible protection of the hardware.
Voltage monitoring
The most important voltages are monitored. When a voltage exceeds warning level high or falls below warning level low an alert will be generated. Adequate measurements can be done by running agents.
Cover monitoring
Opening of the cover causes an immediately shutdown of the system.
Unauthorised opening of the cover is detected, even when the system is switched off. However, this will only be indicated when the system is switched on again
System Event Log (SEL)
All monitored events of the system board are recorded in the System Event Log. They could be retrieved after a system reboot via ServerView.
Page 21
D2440/D2932 (RX330 S1) Technical Manual 21
Features Connectors and DIP switches
3.6 Connectors and DIP switches
Figure 4: Schematic overview of the system boards D2440/D2932
1 = J10 - power supply CPU 2 12 = SAS3
2 = J25 - power supply I
2
C 13 = SAS2
3 = J21 - power supply ATX 14 = SAS1
4 = J17 - power supply CPU 1 15 = SATA1
5 = J22 - safety switch 16 = J51 - left backplane
6 = J15 - IDTEMP 17 = J49 - right backplane
7 = J40 - fan 1-3 Sys 18 = J8 - USB front panel
8 = IDE primary 19 = J48 - LED front panel
9 = SAS6 20 = battery
10 = SAS5 21 = DIP switches
11 = SAS4
CPU 1
DIMM1B
J10
IDE 1
DIMM1A DIMM2B DIMM2A
DIMM4A DIMM4B DIMM3A DIMM3B
CPU 2
J25
J21
J17
J22
J15
J40
ON
1 2 3 4
J8
Battery
J48
J49 J51
SATA1 SAS1 SAS2 SAS3 SAS4 SAS5 SAS6
9
6
7
8
1 2 3 4
5
101112131415161719
20
21
Externe Anschlüsse/
external connectors
18
Page 22
22 Technical Manual D2440/D2932 (RX330 S1)
Connectors and DIP switches Features
Settings with DIP switches
The system board is supplied with all switches set on default position (OFF).
Switch 1
Switch 2
Switch 3
Switch 4
CMOS OFF CMOS/RTC settings are not cleared (default)
ON CMOS/RTC settings are cleared
BIOS Write Protect
OFF The System BIOS can be written or deleted. Flash-
BIOS update from floppy disk is possible (default).
ON The System BIOS can neither be written to nor
deleted. Flash-BIOS update from floppy disk is not possible.
Password Skip OFF The password query is effective (default).
ON The password query is skipped. Passwords are
deleted.
Recovery OFF The System BIOS is started with the system BIOS
from the system board (default).
ON The system boots from the „Flash BIOS floppy disk“
and reprograms the system BIOS on the system board.
Page 23
D2440/D2932 (RX330 S1) Technical Manual 23
Features Connectors and DIP switches
3.6.1 External connectors
Figure 5: External connectors of the system boards D2440/D2932
LAN connectors
On this system board you will find a Broadcom 5715 Dual Gbit LAN controller and a Service LAN controller. The Dual Gbit LAN controller supports the transfer rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s and supports WOL function through Magic Packet™.
It is also possible to boot a device without its own boot hard disk via LAN. Here PXE and iSCSI protocol is supported.
The LAN controller connectors are equipped with two LEDs (light emitting diode) indicating the transfer rate and the activity.
I It is possible to define the LAN port 2 as the Service LAN port and
Standard LAN port via BIOS setting. In this case the LAN port M will be deactivated. The LAN port 2 takes over the Service LAN functionality and the standard LAN port in common (virtual LAN requires two different IP addresses).
1 = PS/2 mouse port 6 = LAN port 1
2 = Serial port COM2 7 = USB port
3 = USB port 2 8 = VGA port
4 = LAN port M (Service LAN) 9 = Serial port COM1
5 = LAN port 2 10 = PS/2 keyboard port
9
6
78
1 2 3 4
5
10
Page 24
24 Technical Manual D2440/D2932 (RX330 S1)
Connectors and DIP switches Features
Figure 6: LAN connectors Dual Gbit LAN controller
Figure 7: LAN connector Service LAN controller
1 LAN link/activity green on LAN connection
off no LAN connection
flashing LAN transfer
2 LAN transfer rate green +
yellow
off transfer rate 10 Mbit/s (or
no connection)
green on transfer rate 100 Mbit/s
yellow on transfer rate 1000 Mbit/s
1 LAN link/activity green on LAN connection
off no LAN connection
flashing LAN transfer
2 LAN transfer rate green off transfer rate 10 Mbit/s (or
no connection)
on transfer rate 100 Mbit/s
1 2
1 2
Page 25
D2440/D2932 (RX330 S1) Technical Manual 25
4 Replacing the lithium battery
In order to save the system information permanently, a lithium battery is installed to provide the CMOS-memory with a current. When the charge is too low or the battery is empty, a corresponding error message is provided. The lithium battery must then be replaced.
V CAUTION!
The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer (CR2032).
Do not throw lithium batteries into the trash can. It must be disposed of in accordance with local regulations concerning special waste.
Make sure that you insert the battery the right way round. The plus pole must be on the top!
Figure 8: Replacing the lithium battery
Ê Press the locking spring into direction of the arrow (1), so that the lithium-
battery jumps out of its socket.
Ê Remove the battery (2).
Ê Insert a new lithium battery of the same type into the socket (3) and (4).
1
2
3
4
Page 26
Page 27
D2440/D2932 (RX330 S1) Technical Manual 27
Abbreviations
The technical terms and abbreviations given below represent only a selection of the full list of common technical terms and abbreviations.
Not all technical terms and abbreviations listed here are valid for the described system board.
AC
Alternating Current
ACPI
Advanced Configuration and Power management Interface
ANSI
American National Standards Institute
ASR&R
Automatic Server Recovery and Restart
ATA
Advanced Technology Attachment
BBU
Battery Backup Unit
BIOS
Basic Input Output System
BMC
Baseboard Management Controller
CMOS
Complementary Metal Oxide Semiconductor
COM
COMmunication port
CPU
Central Processing Unit
Page 28
28 Technical Manual D2440/D2932 (RX330 S1)
Abbreviations
DDR
Double Data Rate
DIMM
Dual In-line Memory Module
DIP
Dual In-line Package
DMI
Desktop Management Interface
DRAM
Dynamic Random Access Memory
ECC
Error Correction Code
EEPROM
Electrical Erasable Programmable Read Only Memory
EFI
Extensible Firmware Interface
EGB
Elektrostatisch gefährdete Bauteile
EHCI
Enhanced Host Controller Interface
EMI
Electromagnetic interference
EMRL
Embedded RAID Logic
EMV
Elektromagnetische Verträglichkeit (electromagnetic compatibility)
EPROM
Erasable Programmable Read Only Memory
Page 29
D2440/D2932 (RX330 S1) Technical Manual 29
Abbreviations
ESD
ElectroStatic Discharge (elektrostatische Entladung)
EVRD
Enterprise VRD
HPC
Hot-plug Controller
FPC
Front Panel Controller
FRU
Field Replaceable Unit
FSB
Front Side Bus
ICE
In Circuit Emulation
IDE
Integrated (intelligent) Drive Electronics
IEC
International Electrotechnical Commission
IME
Integrated Mirroring Enhanced
IOOP
Intelligent Organisation Of PCI
IPMB
Intelligent Platform Management Bus
IPMI
Intelligent Platform Management Interface
iRMC
integrated Remote Management Controller
Page 30
30 Technical Manual D2440/D2932 (RX330 S1)
Abbreviations
ISO
International Organisation for Standardisation
LAN
Local Area Network
LED
Light Emitting Diode
MPS
Multi Processor Specification
NMI
Non Maskable Interrupt
OEM
Original Equipment Manufacturer
OHCI
Open Host Controller Interface
OS
Operating System
PCI
Peripheral Components Interconnect
PDA
Prefailure Detection and Analyzing
PIO
Programmed Input Output
PDB
Power Distribution Board
PLD
Programmable Logic Device
PS(U)
Power Supply (Unit)
Page 31
D2440/D2932 (RX330 S1) Technical Manual 31
Abbreviations
PWM
Pulse Wide Modulation
PXE
Preboot eXecution Environment
RAID
Redundant Array of Inexpensive Disks
RoHS
Restriction of the Use of Certain Hazardous Substances (Waste from Electric and Electronic Equipment, EU Directive)
RoMB
RAID on Motherboard
RSB
Remote Service Board
RST
ReSeT
RTC
Real Time Clock
SAS
Serial Attached SCSI
SATA
Serial ATA
SCSI
Small Computer Systems Interface
SDDC
Single Device Data Correction
SDRAM
Synchronous Dynamic Random Access Memory
SEL
System Event Log
Page 32
32 Technical Manual D2440/D2932 (RX330 S1)
Abbreviations
SHDG
Server Hardware Design Guide
SMB
System Management Bus
SMM
Server Management Mode
SMP
Symmetrical Multi Processing
UHCI
Unified Host Controller Interface
USB
Universal Serial Bus
VGA
Video Graphics Adapter
VRD
Voltage Regulator Down
VRM
Voltage Regulator Module
WEEE
Waste from Electric and Electronic Equipment (EU Directive)
WfM
Wired for Management
WOL
Wake up On LAN