Fujitsu BX600 S2 User Manual

PRIMERGY BX600 S2 Basic Unit
Operating Manual
Edition March 2007
CommentsSuggestionsCorrections
The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs.
Feel free to send us your comments by e-mail to
manuals@fujtsu-siemens.com.
Certified documentation according to DIN EN ISO 9001:2000
To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademarks
Copyright © 2007 Fujitsu Siemens Computers GmbH.
All rights reserved. Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.1 Overview of the Documentation . . . . . . . . . . . . . . . . . 8
1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.3 Notational Conventions . . . . . . . . . . . . . . . . . . . . 14
1.4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . 15
2 Overview: Basic Unit Installation Steps . . . . . . . . . . . 19
3 Important Notes . . . . . . . . . . . . . . . . . . . . . . . . 21
3.1 Notes on Safety . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.2 Components With Electrostatic-Sensitive Devices . . . . . 25
3.3 CE Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.4 FCC Class A Compliance Statement . . . . . . . . . . . . . 26
3.5 Transporting the Basic Unit . . . . . . . . . . . . . . . . . . 27
3.6 Notes on Installing in the Rack . . . . . . . . . . . . . . . . 28
3.7 Environmental Protection . . . . . . . . . . . . . . . . . . . 29
4 Installing the Hardware . . . . . . . . . . . . . . . . . . . . 33
4.1 Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . 33
4.2 Unpacking the Basic Unit . . . . . . . . . . . . . . . . . . . 34
4.3 Installing the System in the Rack . . . . . . . . . . . . . . . 35
4.3.1 Mounting the Assembly Kit . . . . . . . . . . . . . . . . . . . 38
4.3.2 Mounting/Removing the Basic Unit . . . . . . . . . . . . . . . 40
4.4 Connecting External Devices . . . . . . . . . . . . . . . . . 41
4.4.1 Cable Routing . . . . . . . . . . . . . . . . . . . . . . . . . . 43
4.4.2 Instructions on Connecting and Disconnecting Cables . . . . . 45
4.5 Connecting the System to the Mains . . . . . . . . . . . . . 46
PRIMERGY BX600 S2 Basic Unit
Contents
5 Preparation for Use and Operation . . . . . . . . . . . . . . . 49
5.1 Operating and Indicator Elements of the Basic Unit . . . . . 50
5.1.1 The Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
5.1.2 The Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
5.2 Switching the Basic Unit ON/OFF . . . . . . . . . . . . . . . 53
5.3 Management Blade Configuration . . . . . . . . . . . . . . . 55
5.4 Updating System Components . . . . . . . . . . . . . . . . . 60
5.4.1 Updating the Server Blade Firmware (BIOS and BMC) . . . . . 60
5.4.2 Updating the Management Blade Firmware . . . . . . . . . . . 62
5.4.3 Updating the Switch Blade Firmware . . . . . . . . . . . . . . . 64
6 Property and Data Protection . . . . . . . . . . . . . . . . . . 69
6.1 BIOS Setup Security Functions . . . . . . . . . . . . . . . . 69
7 Server Blades . . . . . . . . . . . . . . . . . . . . . . . . . . 71
7.1 Installation Sequence . . . . . . . . . . . . . . . . . . . . . . 73
7.2 Adding a Server Blade to the Basic Unit . . . . . . . . . . . . 76
8 LAN Switch Blades . . . . . . . . . . . . . . . . . . . . . . . 81
8.1 Gbit Ethernet LAN switch blade (SB9) 6x1Gbit . . . . . . . . 82
8.2 Gbit Ethernet LAN switch blade (SB9) 6x1 Gbit + 2x10 Gbit . 84
8.3 Cisco Catalyst Blade Switch 3040 . . . . . . . . . . . . . . . 86
8.4 10 Gbit Switch Blade 10/2 . . . . . . . . . . . . . . . . . . . . 88
8.5 Port Assignment of the LAN Switch Blades . . . . . . . . . . 90
8.6 Installing a LAN Switch Blade . . . . . . . . . . . . . . . . . 93
PRIMERGY BX600 S2 Basic Unit
Contents
9 Ethernet Pass-Thru Blade . . . . . . . . . . . . . . . . . . . 99
9.1 Control and Connection Panel . . . . . . . . . . . . . . . . 100
9.2 Port Assignment of the Gigabit Ethernet Pass-Thru Blades 101
9.3 Replacing an Ethernet Pass-Thru Blade . . . . . . . . . . . 104
10 Fibre Channel Switch Blade . . . . . . . . . . . . . . . . . . 105
10.1 Control and Connection Panel . . . . . . . . . . . . . . . . 106
10.2 Port assignment . . . . . . . . . . . . . . . . . . . . . . . . 108
10.3 FC switch blade installation . . . . . . . . . . . . . . . . . . 111
11 Fibre Channel Pass-Thru Blade . . . . . . . . . . . . . . . . 113
11.1 Control and Connection Panel . . . . . . . . . . . . . . . . 114
11.2 Fibre Channel SFP module . . . . . . . . . . . . . . . . . . 115
11.3 Port Assignment of the FC Pass-Thru Blades . . . . . . . . 117
11.4 Exchanging an FC Pass-Thru Blade . . . . . . . . . . . . . 121
12 Management Blade . . . . . . . . . . . . . . . . . . . . . . . 125
12.1 Control and Connection Panel . . . . . . . . . . . . . . . . 126
12.2 Exchanging the Battery . . . . . . . . . . . . . . . . . . . . 128
12.3 Exchanging a Management Blade . . . . . . . . . . . . . . . 130
13 KVM Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
13.1 KVM Blade (Standard Version) . . . . . . . . . . . . . . . . 133
13.2 Adv. KVM Blade . . . . . . . . . . . . . . . . . . . . . . . . . 135
13.3 Digital KVM Blade . . . . . . . . . . . . . . . . . . . . . . . 137
PRIMERGY BX600 S2 Basic Unit
Contents
14 Power Supply Concept . . . . . . . . . . . . . . . . . . . . 139
14.1 Power Supply Units . . . . . . . . . . . . . . . . . . . . . . 140
14.1.1 Replacing a Power Supply Unit . . . . . . . . . . . . . . . . . 142
14.1.2 Adding a Power Supply Unit . . . . . . . . . . . . . . . . . . 145
15 Ventilation Concept . . . . . . . . . . . . . . . . . . . . . . 149
15.1 The Fan Unit . . . . . . . . . . . . . . . . . . . . . . . . . . 150
15.1.1 Replacing the Fan Unit . . . . . . . . . . . . . . . . . . . . . 151
15.1.2 Replacing a Fan in the Unit . . . . . . . . . . . . . . . . . . . 153
16 Troubleshooting and Tips . . . . . . . . . . . . . . . . . . . 155
16.1 System Power LED Remains Unlit . . . . . . . . . . . . . . 155
16.2 Front or Rear Identify/Fault LED Blinks Amber . . . . . . . 156
16.3 System Switches Itself OFF . . . . . . . . . . . . . . . . . . 157
16.4 Screen Remains Dark . . . . . . . . . . . . . . . . . . . . . 157
16.5 Flickering Stripes on the Monitor Screen . . . . . . . . . . 158
16.6 No Screen Display or Display Drifts . . . . . . . . . . . . . 158
16.7 No Mouse Pointer Displayed On the Screen . . . . . . . . . 158
16.8 Floppy Disk Cannot Be Read/Written . . . . . . . . . . . . 159
16.9 Time and Date Are Not Correct . . . . . . . . . . . . . . . . 159
16.10 Server Blade Does Not Boot . . . . . . . . . . . . . . . . . 159
16.11 Defective Drive . . . . . . . . . . . . . . . . . . . . . . . . . 159
Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
PRIMERGY BX600 S2 Basic Unit

Introduction

1 Introduction
The PRIMERGY BX600 S2 Blade Server System represents a highly compact, power-saving and scalable servers for integration in 19-inch rack systems.
Figure 1: PRIMERGY BX600 S2 Basic Unit
The PRIMERGY BX600 S2 basic unit occupies seven height units in the rack and can accommodate up to ten server blades of different models and configu­rations.
As economical, ultra-compact systems, the server blades with up to eight CPUs are ideal for use by company data centers and Internet service providers. They are perfectly suited for large application servers, terminal servers for CPU­intensive applications, and DBMS servers.
The PRIMERGY BX600 S2 Blade Server System offers a high level of reliability and availability through highly developed hardware and software components. This includes hot-swappable server blades, switch blades, Fibre Channel (FC) and Ethernet pass-thru blades, management blades, hot-swappable power supply units and fan modules, the server management software ServerView, and Remote-Deploy, Prefailure Detection and Analyzing (PDA), and Automatic Server Reconfiguration and Restart (ASR&R).
PRIMERGY BX600 S2 Basic Unit 7

Overview of the Documentation Introduction

Security functions in the BIOS Setup protect the data on the server blades against manipulation. Additional security is provided by the lockable rack door.
1.1 Overview of the Documentation
I PRIMERGY manuals are available in PDF format on the ServerBooks
DVD. The ServerBooks DVD is part of the PRIMERGY ServerView Suite delivered with each server system.
The PDF files for the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available in the Internet can be found via the URL:
http://manuals.fujitsu-siemens.com/primergyservers.html.
Concept and Target Group of this Manual
This operating manual is intended for those responsible for installing the hardware and operating the system. The manual contains all the information required for mounting and operating your PRIMERGY BX600 S2 basic unit.
For a brief overview of the installation steps please see chapter 2 on page 19ff. To understand the different expansion options, you need a knowledge of
hardware and data transmission, as well as basic knowledge of the operating system used.
Additional server documentation
The PRIMERGY BX600 S2 documentation also includes: – “Quick Start Hardware - PRIMERGY BX600 S2/S3” (leaflet)
– “Quick Start Software - PRIMERGY ServerView Suite” (leaflet) – “Warranty” manual (print version supplied with the system, PDF file available
on the ServerBooks DVD supplied)
– “Safety notes and other important information” manual (print version
supplied with the system, PDF file available on the ServerBooks DVD
supplied) – “Ergonomics” manual (PDF file available on the ServerBooks DVD supplied) – “Returning used devices” manual (PDF file available on the ServerBooks DVD
supplied) – “Helpdesk” (leaflet with worldwide helpdesk telephone numbers) – Technical Manual for the Dxxxx system board (PDF file available on the
ServerBooks DVD supplied)
8 PRIMERGY BX600 S2 Basic Unit
Introduction Overview of the Documentation
– “BIOS Setup” (PDF file available on the ServerBooks DVD supplied) – “ServerView Suite” includes the ServerStart Disc 1, the ServerStart Disc 2
and the ServerBooks DVD. The PDF version of the “PRIMERGY ServerView Suite - ServerStart” user manual is also available on the ServerBooks DVD.
I If you need a replacement copy of the ServerBooks DVD, send the
details of your sever to the following e-mail address:
Reklamat-PC-LOG@fujitsu-siemens.com
– „PRIMERGY BX Blade Server Systems: RemoteView Management Blade -
User Interface Description“ (PDF-Version auf ServerBooks-DVD enthalten)
– „PRIMERGY BX Blade Server Systems: LAN Switch Blade - User Interface
Description“ (PDF-Version auf ServerBooks-DVD enthalten)
– „PRIMERGY BX Blade Server Systems: Cisco Catalyst Blade Switch 3040
- Hardware Installation Guide“ (PDF-Version auf ServerBooks-DVD enthalten)
– „PRIMERGY BX Blade Server Systems: LAN Router and Switch Blade -
User Interface Description“ (PDF-Version auf ServerBooks-DVD enthalten)
– „BX600 Digital KVM Switch: User Guide“ (PDF-Version auf ServerBooks-DVD
enthalten)
Further Sources of Information
Further information is provided in: – the RemoteDeploy manual (only relevant for cloning server blades)
– the technical manual for the rack – the manual for the monitor – the ServerView Server Management manual – the manual for the Remote Test and Diagnostic System RemoteView – your operating system documentation – the information files of your operating system
(see also “Related Publications” on page 165).
PRIMERGY BX600 S2 Basic Unit 9

Features Introduction

1.2 Features
The PRIMERGY BX600 S2 basic unit provides a high-level infrastructure for the installed server blades.
Server capacity
The PRIMERGY BX600 S2 basic unit provides slots for up to ten hot-pluggable server blades. For details of the performance features of the different server blade models, see the relevant operating manuals listed under “Related Publi-
cations” on page 165.
Communication interfaces
The PRIMERGY BX600 S2 basic unit has four slots on the back for installing different types of communication blades which allow the installed server blades to be connected to the Ethernet LAN or to SAN environments. The connections can be implemented via switch blades and/or pass-thru blades.
Ethernet LAN switch blade
To connect the server blades to the LAN the following switch blade models
are available:
Gbit Ethernet LAN switch blade (SB9) 6x1Gbit
– 10 internal 1Gbit downlink ports to the server blades – 6 external 1Gbit uplink ports (RJ45)
Gbit Ethernet LAN switch blade (SB9) 10Gbit multi-mode
– 10 internal 1Gbit downlink ports to the server blades – 6 external 1Gbit uplink ports (RJ45) – 2 external 10Gbit uplink ports (1xSFP, 1xCX4)
Cisco Catalyst Blade Switch 3040
– 10 internal 10 1Gbit downlink ports to the server blades – 2 external 10/100/1000BASE-T copper Gigabit Ethernet uplink
ports
– 4 external uplink ports via Cisco SFP modules for 1000BASE-SX
Fibre Optic and 10/100/1000BASE-T copper)
10 PRIMERGY BX600 S2 Basic Unit
Introduction Features
10 Gbit switch blade 10/2
– 10 internal 10 Gbit/s ports to the server blades – 2 external 10 Gbit/s ports with optional X2 transceiver modules for
Fiber optical or CX4 copper cable
I The 10 Gbit switch blade 10/2 only supports server blades,
each equipped with a 10 GbE daughter card.
All switch blades are hot-swappable. By installing two switch blades, redundant LAN connections can be provided for the server blades.
Ethernet LAN Pass-Thru-Blade
The Ethernet LAN Pass-Thru-Blade is an alternative to the switch blade. It provides direct (“pass-thru”) connections to the LAN for the onboard LAN controllers and the optional Gigabit Ethernet I/O modules of the server blades. The Ethernet LAN Pass-Thru-Blade has ten RJ45 connectors.
Fibre Channel pass-thru blade
The PRIMERGY BX600 S2 basic unit can have one or two Fibre Channel pass-thru blades to provide Fibre Channel functionality for the installed server blades. A Fibre Channel (FC) pass-thru blade offers 10 ports for bypass connections between FC daughter cards installed in the server blades and the optical transceivers for serial FC I/O and general I/O signals.
Fibre Channel switch blade
The FC switch blade is an alternative to the FC pass-thru blade. An FC switch blade provides the FC daughter cards of the server blades with up to ten internal fabric ports and up to four external fabric ports. The complete Brocade Fabric OS 5.0.4 scope of supply and services is available as an operating system for the FC switch blade.
Management blade
The PRIMERGY BX600 S2 basic unit accommodates two hot-swappable, redundant management blades with an integrated management solution for complete remote administration of the system.
PRIMERGY BX600 S2 Basic Unit 11
Features Introduction
KVM-Blade
For administering the server blades, the PRIMERGY BX600 S2 basic unit offers a KVM blade, which allows the individual server blades to be connected to a console.
– The standard KVM blade allows a monitor, PS2 keyboard and PS2 mouse
to be connected for local administration of the server blades. – The adv. KVM blade offers the same functionality as the standard version
of the KVM blade plus a LAN port for connecting a Web-based console. – The digital KVM blade offers the same functionality as the standard version
of the KVM blade plus a LAN port for connecting a Web-based console.
Power Supply
Up to four hot-swappable power supply units which adjust automatically to any power voltage in the range 200 - 240 V in a 2+2 redundant power supply config­uration ensure enough power for the system. If one of these units fails, the others ensure that operation continues unimpaired. The defective power supply unit can be replaced during operation (hot-swap).
Ventilation
The system is kept cool by three fans in each power supply unit and four single fans, with two of them mounted one after the other in a housing in the rear chassis. This configuration is redundant and hot-swappable.
High Level of Availability and Failure Protection
When memory data is accessed, 1-bit errors in the main memory are recog­nized and automatically corrected with the ECC (Error Correcting Code) method.
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in the case of an error and automatically “hides” the defective system components.
The PDA (Prefailure Detection and Analyzing) technology from Fujitsu Siemens Computers analyzes and monitors all components relevant for system reliability.
The hot-swappable components provide additional failure protection. Failure protection on a complete blade system is ensured by up to four redundant, hot­swap power supply units (PSU), as well as hot-swap, redundant fans.
12 PRIMERGY BX600 S2 Basic Unit
Introduction Features
Server Management
Server management is implemented via the supplied ServerView software and PDA (Prefailure Detection and Analyzing) technology from Fujitsu Siemens Computers. PDA warns of system errors or overloading before they occur so that preventive measures can be taken.
ServerView allows the management of all PRIMERGY servers in the network via a central console. Here ServerView supports the following functions:
Remote startup (Wake On LAN)
Temperature monitoring of the CPU and the surrounding area
Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R)
in the event of memory modules or processors failing
Power monitoring
End-of-life monitoring of the fans with timely notification before a failure
Watchdog timer for operating system monitoring and application monitoring
with ASR&R
Deployment software makes installing multiple servers fast and easy. For further information, see the corresponding documentation (see “Related Publications”
on page 165).
Information on server management with ServerView is provided in the associated documentation (see also “Related Publications” on page 165).
ServerStart
You can configure the server quickly and precisely with the ServerStart software provided. User-guided menus are available for installing the server operating systems.
Service and Support
PRIMERGY servers are service-friendly and modular, thus allowing quick and easy maintenance.
I For easy and immediate recognition, the levers or handles and locking
buttons (touch points) of the locking mechanisms for the different compo­nents have the color green.
PRIMERGY BX600 S2 Basic Unit 13

Notational Conventions Introduction

The flash EPROM program supplied with the Fujitsu Siemens utilities supports fast BIOS update. The two redundant and hot-swappable management blades with independent management LAN and COM ports ensure complete remote control. Together they facilitate remote diagnosis for system analysis, remote configuration and remote restart, should the operating system or hardware fail.
1.3 Notational Conventions
The following notational conventions are used in this manual:
Italics indicate commands, menu items or software programs. “Quotation marks” indicate names of chapters and terms that should be
emphasized.
Ê Text which follows this symbol describes activities that
must be performed in the order given.
V CAUTION! Pay particular attention to text marked with this symbol.
Failure to observe this warning may endanger your life, damage the server, or lead to loss of data.
I This symbol introduces supplementary information,
remarks and tips.
Table 1: Notational conventions
14 PRIMERGY BX600 S2 Basic Unit

Introduction Technical Data

1.4 Technical Data
Electrical Data (single power supply unit)
Rated voltage range 200 - 240 V Rated frequency 50 Hz - 60 Hz Max. rated current 230V / 11,6 A Max. active power 230 V / 2650 W Max. apparent power 2680 VA (230V) Thermal dissipation 2050 kJ/h Protection class I
Electrical Data (basic unit without server blades)
Power consumption 360 W Thermal dissipation 1300 kJ/h
Compliance Standards
Product safety and ergonomics IEC 60950 / EN 60950 UL 1950 3rd Edition,
CSA 22.2 No. 950
Electromagnetic compatibility FCC class A
Emitted interference EN 55022 class A Harmonic current EN 61000-3-2 Noise immunity EN 55024
CE label according to EU directives
Certification
Product safety Global CB
PRIMERGY BX600 S2 Basic Unit 15
Low-Voltage Directive 73/23/EEC Electromagnetic Compatibility 89/336/EEC
Technical Data Introduction
Europe ENEC Germany GS USA/Canada CSA
US
/ CSA
C
Japan VCCI
Mechanical Values
Width 446 mm Installation depth 740 mm Height 307 mm oder 7 HE
Weight
max. 131.5 kg (depending on the configuration)
16 PRIMERGY BX600 S2 Basic Unit
Introduction Technical Data
Environmental Conditions
Environment class 3K2 Environment class 2K2
DIN IEC 721 section 3-3 DIN IEC 721section 3-2
Temperature:
Operation (3K2) Transport (2K2)
5 ºC .... 35 ºC
-20 °C .... 60 °C
Relative humidity 10%...85%
Condensation during operation must be avoided.
Noise Level
Sound power level L
(ISO 7779) 7.8 BA
WAd
Sound pressure level at bystander position
(ISO 9296)
L
pAm
59 dB(A) (in the standard configuration)
PRIMERGY BX600 S2 Basic Unit 17
2 Overview: Basic Unit Installation
Steps
In this chapter you will find an overview of the steps necessary to install your BX600 S2 basic unit. Links guide you to sections where you can find more detailed information on the individual steps.
Ê Before you begin, please read the chapter “Important Notes” beginning on
page 21, especially the section “Notes on Safety”.
Ê Unpack the system, check the contents of the package for visible transport
damage, and check whether the delivery matches the details in the delivery note (see section 4.2 on page 34).
Ê Mount the system in the rack (see section 4.3 on page 35 and also the layout
arrangement on the order lists).
Ê Cable the system (see section 4.4 on page 41). Please also see the section
“Cable Routing” on page 43 and the section “Instructions on Connecting and Disconnecting Cables” on page 45.
Ê Connect the system to the mains voltage (see section 4.5 on page 46). Ê Familiarize yourself with the operating and indicator elements on the front
and rear sides of the BX600 S2 basic unit (see chapter 5 beginning on
page 49).
Ê Insert the server blades into the slots in the front of the BX600 S2 basic unit
(see chapter 7 on page 71).
Ê Configure the management blades (see section 5.3 on page 55) so that you
can perform further administration of the blade server system via LAN.
Ê Install the desired operating systems and applications on the server blades.
To do so, you have the following options: – Cloning a server blade from a remote image server with RemoteDeploy
Recommended if the following requirements are satisfied: – the RemoteDeploy software is available
– an appropriate cloning image is available – deployment server and LAN connection are available
PRIMERGY BX600 S2 Basic Unit 19
Overview: Basic Unit Installation Steps
Remote installation with ServerStart
This installation method is recommended if a LAN connection and a DHCP server are available but the requirements for cloning are not satisfied.
Local installation with or without ServerStart
Since the local installation is the least convenient installation method, it is only recommended if the requirements for remote installation or cloning are not satisfied.
If you wish to install an operating system that is not supported by Server­Start, you can perform the installation directly without using ServerStart.
I For further information on remote or local installation of server blades,
please see the ServerStart manual, which contains a “Quick Step Guide” as well as a detailed description of the different installation options and installation wizards. A print version of the ServerStart manual is included in the PRIMERGY ServerView Suite, which comes with the BX600 S2 basic unit. A PDF version of the manual is contained on the PRIMERGY ServerBooks DVD.
Cloning of server blades is described in the RemoteDeploy manual (print version delivered with RemoteDeploy, PDF version contained on the PRIMERGY ServerBooks DVD).
20 PRIMERGY BX600 S2 Basic Unit

3 Important Notes

In this chapter you will find essential information on safety when working with your system.

3.1 Notes on Safety

I You will also find the following safety instructions in the manual entitled
“Safety“, which also includes additional notes on the guarantee and ergonomics.
This device complies with the relevant safety regulations for data processing equipment, including electronic office machines for use in an office environment.
If you have any questions, please contact your sales outlet or the customer service center of Fujitsu Siemens Computers.
V CAUTION!
The actions described in these instructions should only be performed by technicians, service personnel or technical specialists. Equipment repairs should only be performed by qualified staff. Any failure to observe the guidelines in this manual could expose the user to risks (electric shock, fire hazards) and could also damage the equipment. Note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability.
PRIMERGY BX600 S2 Basic Unit 21
Notes on Safety Important Notes
Before Setting Up
V CAUTION!
During installation and before operating the device, observe the
instructions on environmental conditions for your device in the section
“Technical Data” on page 15.
If the device is brought in from a cold environment, condensation may
form on both the inside and outside of the machine. Before operating the device, wait until it is absolutely dry and has
reached approximately the same temperature as the installation site. Failure to observe these guidelines can lead to physical damage of the device.
Transport the device only in the original packaging or in packaging
which protects it from knocks and jolts.
Installation and Operation
V CAUTION!
For safety reasons, make sure you read any warning labels when
removing modules from the server.
Beware of energy hazards on the plug-in contacts of the midplane. A
short circuit on these connections can lead to damage to the system.
PRIMERGY BX620 S4 server blades are not for use in slots 4 an 10
of the PRIMERGY BX600 S2 basic unit.
If the server is integrated in a (rack) installation that receives power
from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type-A connector.
For the PRIMERGY BX600 S2 basic unit only 2100W PSUs are
allowed (Product no. A3C40073262)! The 1200W PSUs of the PRIMERGY BX600 S1 basic unit is not allowed for the PRIMERGY BX600 S2 basic unit.
The 2100W PSU is not allowed for the PRIMERGY BX600 S1 basic unit.
22 PRIMERGY BX600 S2 Basic Unit
Important Notes Notes on Safety
Make sure that the PRIMERGY BX600 S2 basic unit is connected to
the mains for at least one minute before pressing the power ON/OFF button to switch the system ON.
V CAUTION!
The server automatically adjusts to a mains voltage of 200 - 240 V.
The server may only be put into operation if the mains voltage range set on the server corresponds to the local mains voltage.
This device has safety-tested power cables and must only be
connected to properly grounded power sockets or CEE sockets.
The power button does not disconnect the device from the mains
voltage. To completely disconnect it from the mains voltage, the power plugs must be removed from the power socket.
Data transmission cables must not be connected or disconnected
during a thunderstorm (lightning hazard).
Make sure that no objects (such as bracelets or paper clips) or liquids
fall/spill into the device (risk of electric shock or short circuit).
Data cables must be adequately shielded to avoid interference.
The LAN wiring must comply with the standards EN 50173 and EN
50174-1/2. The minimum requirement is a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet. The requirements of the specification ISO/IEC 11801 must be observed.
In an emergency (e.g. damage to housing, control elements or
cables, the ingress of liquids or foreign bodies), switch the unit off immediately, pull the power plug out of the grounding outlet or the CEE outlet, and contact Service.
Proper operation of the device (in accordance with IEC 60950/DIN
EN 60950) is only ensured if the casing is completely assembled and the dummy units for the installation openings have been put in place (electric shock, cooling, fire protection, interference suppression).
Install only system extensions that satisfy the requirements and rules
governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other exten­sions, you may damage the system or violate the safety regulations
PRIMERGY BX600 S2 Basic Unit 23
Notes on Safety Important Notes
and regulations on RFI suppression. Information on which system extensions are suitable can be obtained from the customer service center or your sales outlet.
V CAUTION!
The components (e.g. power supply) marked with a warning label
(e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. The hot-swap or hot-plug compo­nents are exceptions to this rule.
The warranty is invalidated if the device is damaged during the instal-
lation or replacement of system extensions.
You may set only those resolutions and refresh rates specified in the
“Technical data” section of the monitor description. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center.
Batteries
V CAUTION!
Incorrect replacement of batteries may lead to a risk of explosion. The
battery may only be replaced with an identical battery or with a type recommended by the manufacturer.
Do not throw batteries into the trash can. They must be disposed of
in accordance with local regulations concerning special waste.
Replace the lithium battery on the relevant components according to
the instructions in this manual.
All batteries containing pollutants are marked with a symbol (a
crossed-out garbage can) as well as the chemical symbol for the heavy metal which classifies it as a pollutant:
Cd Cadmium Hg Mercury Pb Lead
Other Important Notes:
Keep this operating manual and all additional documentation together with
the device.
If you pass on the device to third parties, you should also pass on the
complete documentation.
24 PRIMERGY BX600 S2 Basic Unit

Important Notes Components With Electrostatic-Sensitive Devices

3.2 Components With Electrostatic-Sensitive Devices
Electrostatic-sensitive components are identified by the following sticker:
Figure 2: ESD label
When you handle components fitted with ESDs, you must observe the following points under all circumstances:
Always discharge static build-up (e.g. by touching a grounded object) before
working.
The equipment and tools you use must be free of static charge.
Always hold components with ESDs by their edges.
Do not touch any exposed pins or conductors on a component.
Use a grounding cable designed for this purpose to connect yourself to the
system unit as you install components.
Place all components on a static-proof base.
I You will find a detailed description of how to handle ESD components in
the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

3.3 CE Certificate

The shipped version of this device complies with the requirements of the EEC directives 89/336/EEC “Electromagnetic compatibility” and 73/23/EEC “Low voltage directive”. The device therefore qualifies for the CE certificate (CE=Communauté Européenne).
PRIMERGY BX600 S2 Basic Unit 25

FCC Class A Compliance Statement Important Notes

3.4 FCC Class A Compliance Statement
If there is an FCC statement on the device, then: The following statement applies to the products covered in this manual, unless
otherwise specified herein. The statement for other products will appear in the accompanying documentation.
NOTE:
This equipment has been tested and found to comply with the limits for a “Class A” digital device, pursuant to Part 15 of the FCC rules, and meets all requirements of the Canadian Interference-Causing Equipment Standard ICES-003 for digital apparatus. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in strict accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that inter­ference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between equipment and the receiver.
Connect the equipment to an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Fujitsu Siemens Computers is not responsible for any radio or television inter­ference caused by unauthorized modifications of this equipment or the substi­tution or attachment of connecting cables and equipment other than those specified by Fujitsu Siemens Computers. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules.
26 PRIMERGY BX600 S2 Basic Unit

Important Notes Transporting the Basic Unit

3.5 Transporting the Basic Unit
V CAUTION!
Transport the PRIMERGY BX600 S2 basic unit only in its original packaging or in a packaging which protects it from knocks and jolts. Do not unpack the basic unit until you have finished transporting it.
For safety reasons, at least two people are needed to install the basic unit because of its weight and size.
Before lifting the basic unit into the rack, remove server blades, fan units and power supplies from the system unit to reduce weight.
Use the handles on the front and the fold-away handles on the long sides to lift or carry the base unit.
Never lift or transport the basic unit using the handles on the rear.
PRIMERGY BX600 S2 Basic Unit 27

Notes on Installing in the Rack Important Notes

3.6 Notes on Installing in the Rack
V CAUTION!
For safety reasons, at least two people are needed to install the
basic unit because of its weight and size.
For lifting the basic unit, use the handles on the front and the fold-out
handles on the long sides of the chassis.
Before lifting the basic unit into the rack, remove server blades, fan
units and power supplies from the system unit to reduce weight.
For lifting the basic unit, use the handles on the front and the fold-out
handles on the long sides of the chassis.
Never lift or transport the server using the handles on the rear.
For safety reasons only one unit may be withdrawn from the rack at a
time when performing assembly or service work.
Ensure that the anti-tilt bracket is correctly mounted when you set up
the rack.
If more than one unit is withdrawn from the rack at any one time, the
rack is in danger of tilting forward.
When connecting and disconnecting cables, read the relevant notes
in the “Important notes” chapter in the technical manual for the relevant rack. The technical manual is supplied with the corre­sponding rack.
The power connection for the rack must be installed by an authorized
technician (electrician).
If the server is integrated in a (rack) installation that receives power
from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type-A connector.
The power supply for the rack should be divided amongst the three
phases of a three-phase power connection.
28 PRIMERGY BX600 S2 Basic Unit

Important Notes Environmental Protection

3.7 Environmental Protection
Environmentally Friendly Product Design and Development
This product has been designed in accordance with the Fujitsu Siemens Computers standards for ”environmentally friendly product design and devel­opment“. This means that the designers have taken into account important criteria such as durability, selection of materials and coding, emissions, packaging, the ease with which the product can be dismantled and the extent to which it can be recycled.
This saves resources and thus reduces the harm done to the environment.
Notes on Saving Energy
Devices that do not have to be on permanently should not be switched on until they need to be used and should be switched off during long breaks and on completion of work
Notes on Packaging
Please do not throw away the packaging. It may be needed later for transporting your system unit. If possible, devices should be transported in their original packaging.
Notes on Dealing with Consumables
Please dispose of printer consumables and batteries in accordance with local government regulations.
Do not throw batteries and accumulators into the household waste. They must be disposed of in accordance with local regulations concerning special waste (see also “Returning Batteries” on page 31).
Notes on Labeling Plastic Housing Parts
Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them.
PRIMERGY BX600 S2 Basic Unit 29
Environmental Protection Important Notes
Returning Used Electrical and Electronic Devices in EU Countries
– Separate collection
Users of electrical and electronic devices are obligated to collect used devices separately. Electrical (electronic) used devices may not be disposed of together with unsorted household refuse. The separate collection is a condition for reuse, recycling and utilisation of used electrical (electronic) devices, which ensures the protection of resources.
– Return and collection systems
Electrical (electronic) used devices from private households can be returned free of charge. To return your used device, please use the country-specific return and collection systems available to you (see “Local Contacts” on
page 31).
The return of used devices which pose a health or safety risk for human beings due to soiling during use may be refused.
– Reuse, recycling and utilisation
By actively using the offered return and collection systems, you make your contribution to the reuse, recycling and utilisation of electrical (electronic) devices.
– Effects on the environment and human health
Electrical (electronic) used devices contain parts which must be handled selectively according to the EU directive. Separate collection and selective treatment are the basis for environment-friendly disposal and the protection of human health.
– Meaning of the symbol "Crossed out rubbish bin on wheels"
Electrical (electronic) devices which are marked with one of the following symbols may not be disposed of with household refuse in accordance with the EU directive.
Figure 3: Symbols for electrical (electronic) devices
30 PRIMERGY BX600 S2 Basic Unit