Fujitsu AUYG09LVLA, AUYG18LVLB, ARYG12LSLAP, ARYG14LSLAP, ARYG18LSLAP Design & Technical Manual

...
AIR CONDITIONER
Multi: 5, 6 rooms type
DESIGN & TECHNICAL MANUAL
INDOOR
ARYG18LLTB ASYG07LMCA
ABYG14LVTA
ABYG18LVTB
AUYG07LVLA AUYG09LVLA
AUYG12LVLB AUYG14LVLB AUYG18LVLB
ASYG09LMCA ASYG12LMCA ASYG14LMCA
AGYG09LVCA AGYG12LVCA AGYG14LVCA
ARYG07LSLAP ARYG09LSLAP ARYG12LSLAP ARYG14LSLAP
ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE
ARYG18LSLAP ARYG07LLTA
ARYG12LLTB ARYG14LLTB
ASYG07LUCA ASYG09LUCA ASYG12LUCA ASYG14LUCA
ASYG18LFCA ASYG24LFCA ASYG24LFCC
OUTDOOR
AOYG36LBLA5 AOYG45LBLA6
DR_MU006EF_03
2017.05.22
Notices:
• Product specifications and design are subject to change without notice for future improvement.
• For further details, please check with our authorized dealer.
Copyright © 2017 Fujitsu General Limited. All rights reserved.
CONTENTS
Part 1. INDOOR UNIT....................................................................... 1
1. Model lineup ..............................................................................................2
1-1. Connectable indoor units to each outdoor unit............................................................ 3
1-2. Indoor unit connection patterns................................................................................... 4
2. Specifications............................................................................................9
2-1. Compact cassette type ............................................................................................... 9
2-2. Mini duct type............................................................................................................ 11
2-3. Slim duct type ........................................................................................................... 13
2-4. Wall mounted type .................................................................................................... 15
2-5. Floor/Ceiling type...................................................................................................... 19
2-6. Floor type.................................................................................................................. 20
3. Dimensions..............................................................................................21
3-1. Compact cassette type ............................................................................................. 21
3-2. Mini duct type............................................................................................................ 23
3-3. Slim duct type ........................................................................................................... 26
3-4. Wall mounted type .................................................................................................... 30
3-5. Floor/Ceiling type...................................................................................................... 38
3-6. Floor type.................................................................................................................. 40
4. Wiring diagrams ......................................................................................41
4-1. Compact cassette type ............................................................................................. 41
4-2. Mini duct type............................................................................................................ 42
4-3. Slim duct type ........................................................................................................... 43
4-4. Wall mounted type .................................................................................................... 44
4-5. Floor/Ceiling type...................................................................................................... 47
4-6. Floor type.................................................................................................................. 48
5. Air velocity and temperature distributions ........................................... 49
5-1. Compact cassette type ............................................................................................. 49
5-2. Mini duct type............................................................................................................ 57
5-3. Slim duct type ........................................................................................................... 67
5-4. Wall mounted type .................................................................................................... 77
5-5. Floor/Ceiling type...................................................................................................... 85
5-6. Floor type.................................................................................................................. 89
6. Fan performance .....................................................................................90
6-1. Mini duct type............................................................................................................ 90
6-2. Slim duct type ......................................................................................................... 100
7. Airflow....................................................................................................110
7-1. Compact cassette type ........................................................................................... 110
7-2. Mini duct type.......................................................................................................... 111
7-3. Slim duct type ......................................................................................................... 112
7-4. Wall mounted type .................................................................................................. 113
7-5. Floor/Ceiling type.................................................................................................... 115
CONTENTS (continued)
7-6. Floor type................................................................................................................ 115
8. Noise level curve...................................................................................116
8-1. Compact cassette type ........................................................................................... 116
8-2. Mini duct type.......................................................................................................... 119
8-3. Slim duct type ......................................................................................................... 122
8-4. Wall mounted type .................................................................................................. 125
8-5. Floor/Ceiling type.................................................................................................... 130
8-6. Floor type................................................................................................................ 131
8-7. Sound level check point.......................................................................................... 133
9. Electrical characteristics ......................................................................136
10. Safety devices ....................................................................................... 137
11. External input and output..................................................................... 138
11-1.Compact cassette, slim duct, wall mounted, floor/ceiling, and floor types.............. 138
11-2.Mini duct type......................................................................................................... 148
12. Group connection ................................................................................. 154
12-1.Precautions on creating a group connection.......................................................... 155
12-2.Remote controller address setting procedure for wireless remote controllers........ 157
13. Remote controller .................................................................................158
13-1.Wireless remote controller (AR-RAH2E/AR-RAH1E)............................................. 158
13-2.Wireless remote controller (AR-REA2E/AR-REB1E) ............................................. 161
13-3.IR receiver kit with Wireless remote controller (UTY-LRHYM: Optional part)......... 164
13-4.IR receiver kit with Wireless remote controller (UTY-LBTYM: Optional part) ......... 167
13-5.Wired remote controller (UTY-RNNYM)................................................................. 170
13-6.Wired remote controller (UTY-RLRY) .................................................................... 175
13-7.Wired remote controller (UTY-RVNYM: Optional part)........................................... 178
13-8.Wired remote controller (UTY-RNRYZ*: Optional part).......................................... 187
13-9.Simple remote controller (UTY-RSNYM: Optional part) ......................................... 190
13-10.Simple remote controller (UTY-RSRY and UTY-RHRY: Optional parts).............. 195
14. Function settings .................................................................................. 198
14-1.Compact cassette, slim duct, and floor/ceiling types indoor unit (setting by DIP switch
and jumper wire)........................................................................................................ 198
14-2.Mini duct type indoor unit (setting by DIP switch)................................................... 200
14-3.Indoor unit (setting by wireless remote controller).................................................. 202
14-4.Indoor unit (setting by wired remote controller)...................................................... 223
14-5.Indoor unit (setting by simple remote controller) .................................................... 234
14-6.Function details...................................................................................................... 241
14-7.Wired remote controller (UTY-RNNYM)................................................................. 249
14-8.Wired remote controller (UTY-RVNYM)................................................................. 251
14-9.Wired remote controller (UTY-RLRY) .................................................................... 252
14-10.Wired remote controller (UTY-RNRYZ*) .............................................................. 253
14-11.Simple remote controller (UTY-RSNYM).............................................................. 254
15. Accessories ...........................................................................................255
15-1.Compact cassette type .......................................................................................... 255
CONTENTS (continued)
15-2.Mini duct type......................................................................................................... 256
15-3.Slim duct type ........................................................................................................ 257
15-4.Wall mounted type ................................................................................................. 258
15-5.Floor/Ceiling type................................................................................................... 261
15-6.Floor type............................................................................................................... 262
16. Optional parts........................................................................................263
16-1.Controllers ............................................................................................................. 263
16-2.Cassette grille ........................................................................................................ 265
16-3.Others.................................................................................................................... 266
17. Indoor unit installation precautions .................................................... 270
17-1.Place where prohibited for use............................................................................... 270
17-2.Points to remember when installing ....................................................................... 271
CONTENTS (continued)
Part 2. OUTDOOR UNIT (5 ROOMS TYPE) ................................ 273
1. Specifications........................................................................................274
2. Dimensions............................................................................................276
2-1. Model: AOYG36LBLA5........................................................................................... 276
3. Installation space ..................................................................................277
3-1. Model: AOYG36LBLA5........................................................................................... 277
4. Refrigerant circuit ................................................................................. 280
4-1. Model: AOYG36LBLA5........................................................................................... 280
5. Wiring diagram ......................................................................................281
5-1. Model: AOYG36LBLA5........................................................................................... 281
6. Capacity table........................................................................................282
6-1. Combinations.......................................................................................................... 282
6-2. Cooling capacity...................................................................................................... 287
6-3. Heating capacity ..................................................................................................... 302
7. Capacity compensation rate for pipe length and height difference..316
7-1. Model: AOYG36LBLA5........................................................................................... 316
8. Additional charge calculation .............................................................. 320
8-1. Model: AOYG36LBLA5........................................................................................... 320
9. Airflow....................................................................................................321
9-1. Model: AOYG36LBLA5........................................................................................... 321
10. Operation noise (sound pressure)....................................................... 322
10-1.Noise level curve.................................................................................................... 322
10-2.Sound level check point......................................................................................... 322
11. Electrical characteristics ......................................................................323
12. Safety devices ....................................................................................... 324
13. Function settings .................................................................................. 325
13-1.Setting methods..................................................................................................... 325
13-2.Outdoor unit low noise operation function (option)................................................. 328
13-3.Changing the current limit function......................................................................... 328
14. Check and test....................................................................................... 329
14-1.Check run .............................................................................................................. 329
14-2.Test run.................................................................................................................. 335
14-3.Error code .............................................................................................................. 336
14-4.Pump down............................................................................................................ 339
15. Accessories ...........................................................................................341
16. Optional parts........................................................................................342
17. Outdoor unit installation precautions ................................................. 343
17-1.Place where prohibited for use............................................................................... 343
17-2.Points to remember when installing ....................................................................... 343
CONTENTS (continued)
Part 3. OUTDOOR UNIT (6 ROOMS TYPE) ................................ 345
1. Specifications........................................................................................346
2. Dimensions............................................................................................347
2-1. Model: AOYG45LBLA6........................................................................................... 347
3. Installation space ..................................................................................348
3-1. Model: AOYG45LBLA6........................................................................................... 348
4. Refrigerant circuit ................................................................................. 351
4-1. Model: AOYG45LBLA6........................................................................................... 351
5. Wiring diagram ......................................................................................352
5-1. Model: AOYG45LBLA6........................................................................................... 352
6. Capacity table........................................................................................353
6-1. Combinations.......................................................................................................... 353
6-2. Cooling capacity...................................................................................................... 361
6-3. Heating capacity ..................................................................................................... 376
7. Capacity compensation rate for pipe length and height difference..390
7-1. Model: AOYG45LBLA6........................................................................................... 390
8. Additional charge calculation .............................................................. 394
8-1. Model: AOYG45LBLA6........................................................................................... 394
9. Airflow....................................................................................................395
9-1. Model: AOYG45LBLA6........................................................................................... 395
10. Operation noise (sound pressure)....................................................... 396
10-1.Noise level curve.................................................................................................... 396
10-2.Sound level check point......................................................................................... 396
11. Electrical characteristics ......................................................................397
12. Safety devices ....................................................................................... 398
13. Function settings .................................................................................. 399
13-1.Setting methods..................................................................................................... 399
13-2.Outdoor unit low noise operation function (option)................................................. 402
13-3.Changing the current limit function......................................................................... 402
14. Check and test....................................................................................... 403
14-1.Check run .............................................................................................................. 403
14-2.Test run.................................................................................................................. 409
14-3.Error code .............................................................................................................. 410
14-4.Pump down............................................................................................................ 413
15. Accessories ...........................................................................................415
16. Optional parts........................................................................................416
17. Outdoor unit installation precautions ................................................. 417
17-1.Place where prohibited for use............................................................................... 417
17-2.Points to remember when installing ....................................................................... 417

Part 1. INDOOR UNIT

COMPACT CASSETTE TYPE:
AUYG07LVLA AUYG09LVLA
ARYG07LSLAP ARYG09LSLAP
ARYG07LLTA ARYG09LLTA
ASYG07LUCA ASYG09LUCA ASYG12LUCA ASYG14LUCA
AUYG12LVLB AUYG14LVLB
MINI DUCT TYPE:
ARYG12LSLAP ARYG14LSLAP
SLIM DUCT TYPE:
ARYG12LLTB ARYG14LLTB
WALL MOUNTED TYPE:
ASYG07LMCA ASYG09LMCA ASYG12LMCA ASYG14LMCA
ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE
FLOOR/CEILING TYPE:
AUYG18LVLB
ARYG18LSLAP
ARYG18LLTB
ASYG18LFCA ASYG24LFCA ASYG24LFCC
ABYG14LVTA ABYG18LVTB
FLOOR TYPE:
AGYG09LVCA AGYG12LVCA AGYG14LVCA

1. Model lineup

MULTI TYPE
5, 6 ROOMS TYPE
AUYG07LVLA AUYG09LVLA AUYG12LVLB AUYG14LVLB AUYG18LVLB
Indoor unit
ARYG07LSLAP ARYG09LSLAP ARYG12LSLAP ARYG14LSLAP
ARYG18LSLAP
ARYG07LLTA ARYG09LLTA ARYG12LLTB ARYG14LLTB
ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE
ABYG14LVTA ABYG18LVTB
ARYG18LLTB ASYG07LMCA
ASYG09LMCA ASYG12LMCA ASYG14LMCA
ASYG07LUCA ASYG09LUCA ASYG12LUCA ASYG14LUCA
AGYG09LVCA AGYG12LVCA AGYG14LVCA
ASYG18LFCA ASYG24LFCA ASYG24LFCC
Outdoor unit
AOYG36LBLA5 AOYG45LBLA6
- 2 -

1-1. Connectable indoor units to each outdoor unit

●: Connectable / -: Not connectable
Compact cassette Mini duct
Outdoor unit
Btu class 07 09 12 14 18 07 09 12 14 18
kW class 2.0 2.5 3.5 4.0 5.0 2.0 2.5 3.5 4.0 5.0 AOYG36LBLA5 ● AOYG45LBLA6
Outdoor unit
Btu class 07 09 12 14 18 07 09 12 14
kW class 2.0 2.5 3.5 4.0 5.0 2.0 2.5 3.5 4.0 AOYG36LBLA5 ● AOYG45LBLA6
Outdoor unit
Btu class 18 24 14 18 09 12 14
kW class 5.0 7.0 4.0 5.0 2.5 3.5 4.0 AOYG36LBLA5 ● AOYG45LBLA6
AUYG07—09LVLA AUYG12—18LVLB
ARYG07—09LLTA ARYG12—18LLTB
Wall mounted
LF
ASYG18LFCA ASYG24LFCA
ASYG24LFCC
ARYG07—18LSLAP
Slim duct Wall mounted
LU/LM ASYG07—14LMCA ASYG07—14LMCE
ASYG07—14LUCA
Floor/Ceiling Floor
ABYG14LVTA ABYG18LVTB
AGYG09—14LVCA
MULTI TYPE
5, 6 ROOMS TYPE
- 3 -

1-2. Indoor unit connection patterns

¢ 5 rooms
MULTI TYPE
5, 6 ROOMS TYPE
AOYG36LBLA5
No. Room 1 Room 2 Room 3 Room 4 Room 5 Total
1 7 24 31 2 9 24 33 3 12 24 36 4 14 24 38 5 18 18 36 6 18 24 42 7 24 24 48 8 7 7 14 28
9 7 7 18 32 10 7 7 24 38 11 7 9 12 28 12 7 9 14 30 13 7 9 18 34 14 7 9 24 40 15 7 12 12 31 16 7 12 14 33 17 7 12 18 37 18 7 12 24 43 19 7 14 14 35 20 7 14 18 39 21 7 14 24 45 22 7 18 18 43 23 7 18 24 49 24 9 9 9 27 25 9 9 12 30 26 9 9 14 32 27 9 9 18 36 28 9 9 24 42 29 9 12 12 33 30 9 12 14 35 31 9 12 18 39 32 9 12 24 45 33 9 14 14 37 34 9 14 18 41 35 9 14 24 47 36 9 18 18 45 37 9 18 24 51 38 12 12 12 36 39 12 12 14 38 40 12 12 18 42 41 12 12 24 48 42 12 14 14 40 43 12 14 18 44 44 12 14 24 50 45 12 18 18 48 46 12 18 24 54 47 14 14 14 42 48 14 14 18 46 49 14 14 24 52 50 14 18 18 50 51 18 18 18 54 52 7 7 7 7 28 53 7 7 7 9 30 54 7 7 7 12 33 55 7 7 7 14 35 56 7 7 7 18 39 57 7 7 7 24 45 58 7 7 9 9 32 59 7 7 9 12 35 60 7 7 9 14 37 61 7 7 9 18 41 62 7 7 9 24 47 63 7 7 12 12 38 64 7 7 12 14 40 65 7 7 12 18 44 66 7 7 12 24 50 67 7 7 14 14 42 68 7 7 14 18 46 69 7 7 14 24 52 70 7 7 18 18 50 71 7 9 9 9 34 72 7 9 9 12 37 73 7 9 9 14 39 74 7 9 9 18 43 75 7 9 9 24 49 76 7 9 12 12 40 77 7 9 12 14 42 78 7 9 12 18 46 79 7 9 12 24 52 80 7 9 12 14 42 81 7 9 14 18 48 82 7 9 14 24 54 83 7 9 18 18 52 84 7 12 12 12 43
- 4 -
AOYG36LBLA5
No. Room 1 Room 2 Room 3 Room 4 Room 5 Total
85 7 12 12 14 45 86 7 12 12 18 49 87 7 12 14 14 47 88 7 12 14 18 51 89 7 14 14 14 49 90 7 14 14 18 53 91 9 9 9 9 36 92 9 9 9 12 39 93 9 9 9 14 41 94 9 9 9 18 45 95 9 9 9 24 51 96 9 9 12 12 42 97 9 9 12 14 44 98 9 9 12 18 48
99 9 9 12 24 54 100 9 9 14 14 46 101 9 9 14 18 50 102 9 9 18 18 54 103 9 12 12 12 45 104 9 12 12 14 47 105 9 12 12 18 51 106 9 12 14 14 49 107 9 12 14 18 53 108 9 14 14 14 51 109 12 12 12 12 48 110 12 12 12 14 50 111 12 12 12 18 54 112 12 12 14 14 52 113 12 14 14 14 54 114 7 7 7 7 7 35 115 7 7 7 7 9 37 116 7 7 7 7 12 40 117 7 7 7 7 14 42 118 7 7 7 7 18 46 119 7 7 7 7 24 52 120 7 7 7 9 9 39 121 7 7 7 9 12 42 122 7 7 7 9 14 44 123 7 7 7 9 18 48 124 7 7 7 9 24 54 125 7 7 7 12 12 45 126 7 7 7 12 14 47 127 7 7 7 12 18 51 128 7 7 7 14 14 49 129 7 7 7 14 18 53 130 7 7 9 9 9 41 131 7 7 9 9 12 44 132 7 7 9 9 14 46 133 7 7 9 9 18 50 134 7 7 9 12 12 47 135 7 7 9 12 14 49 136 7 7 9 12 18 53 137 7 7 9 14 14 51 138 7 7 12 12 12 50 139 7 7 12 12 14 52 140 7 7 12 14 14 54 141 7 9 9 9 9 43 142 7 9 9 9 12 46 143 7 9 9 9 14 48 144 7 9 9 9 18 52 145 7 9 9 12 12 49 146 7 9 9 12 14 51 147 7 9 9 14 14 53 148 7 9 12 12 12 52 149 7 9 12 12 14 54 150 9 9 9 9 9 45 151 9 9 9 9 12 48 152 9 9 9 9 14 50 153 9 9 9 9 18 54 154 9 9 9 12 12 51 155 9 9 9 12 14 53 156 9 9 12 12 12 54
MULTI TYPE
5, 6 ROOMS TYPE
NOTE:
7: 7,000Btu/h, 9: 9,000Btu/h, 12: 12,000Btu/h, 14: 14,000Btu/h, 18: 18,000Btu/h, 24: 24,000Btu/h
- 5 -
¢ 6 rooms
MULTI TYPE
5, 6 ROOMS TYPE
AOYG45LBLA6
No. Room 1 Room 2 Room 3 Room 4 Room 5 Room 6 Total
1 12 24 36 2 14 24 38 3 18 18 36 4 18 24 42 5 24 24 48 6 7 7 24 38 7 7 9 18 34 8 7 9 24 40
9 7 12 18 37 10 7 12 24 43 11 7 14 14 35 12 7 14 18 39 13 7 14 24 45 14 7 18 18 43 15 7 18 24 49 16 7 24 24 55 17 9 9 18 36 18 9 9 24 42 19 9 12 14 35 20 9 12 18 39 21 9 12 24 45 22 9 14 14 37 23 9 14 18 41 24 9 14 24 47 25 9 18 18 45 26 9 18 24 51 27 9 24 24 57 28 12 12 12 36 29 12 12 14 38 30 12 12 18 42 31 12 12 24 48 32 12 14 14 40 33 12 14 18 44 34 12 14 24 50 35 12 18 18 48 36 12 18 24 54 37 12 24 24 60 38 14 14 14 42 39 14 14 18 46 40 14 14 24 52 41 14 18 18 50 42 14 18 24 56 43 14 24 24 62 44 18 18 18 54 45 18 18 24 60 46 7 7 7 14 35 47 7 7 7 18 39 48 7 7 7 24 45 49 7 7 9 12 35 50 7 7 9 14 37 51 7 7 9 18 41 52 7 7 9 24 47 53 7 7 12 12 38 54 7 7 12 14 40 55 7 7 12 18 44 56 7 7 12 24 50 57 7 7 14 14 42 58 7 7 14 18 46 59 7 7 14 24 52 60 7 7 18 18 50 61 7 7 18 24 56 62 7 7 24 24 62 63 7 9 9 9 34 64 7 9 9 12 37 65 7 9 9 14 39 66 7 9 9 18 43 67 7 9 9 24 49 68 7 9 12 12 40 69 7 9 12 14 42 70 7 9 12 18 46 71 7 9 12 24 52 72 7 9 14 14 44 73 7 9 14 18 48 74 7 9 14 24 54 75 7 9 18 18 52 76 7 9 18 24 58 77 7 12 12 12 43 78 7 12 12 14 45 79 7 12 12 18 49 80 7 12 12 24 55 81 7 12 14 14 47 82 7 12 14 18 51 83 7 12 14 24 57 84 7 12 18 18 55 85 7 12 18 24 61 86 7 14 14 14 49 87 7 14 14 18 53 88 7 14 14 24 59
- 6 -
AOYG45LBLA6
No. Room 1 Room 2 Room 3 Room 4 Room 5 Room 6 Total
89 7 14 18 18 57 90 7 18 18 18 61 91 9 9 9 9 36 92 9 9 9 12 39 93 9 9 9 14 41 94 9 9 9 18 45 95 9 9 9 24 51 96 9 9 12 12 42 97 9 9 12 14 44 98 9 9 12 18 48
99 9 9 12 24 54 100 9 9 14 14 46 101 9 9 14 18 50 102 9 9 14 24 56 103 9 9 18 18 54 104 9 9 18 24 60 105 9 12 12 12 45 106 9 12 12 14 47 107 9 12 12 18 51 108 9 12 12 24 57 109 9 12 14 14 49 110 9 12 14 18 53 111 9 12 14 24 59 112 9 12 18 18 57 113 9 14 14 14 51 114 9 14 14 18 55 115 9 14 14 24 61 116 9 14 18 18 59 117 12 12 12 12 48 118 12 12 12 14 50 119 12 12 12 18 54 120 12 12 12 24 60 121 12 12 14 14 52 122 12 12 14 18 56 123 12 12 14 24 62 124 12 12 18 18 60 125 12 14 14 14 54 126 12 14 14 18 58 127 12 14 18 18 62 128 7 7 7 7 7 35 129 7 7 7 7 9 37 130 7 7 7 7 12 40 131 7 7 7 7 14 42 132 7 7 7 7 18 46 133 7 7 7 7 24 52 134 7 7 7 9 9 39 135 7 7 7 9 12 42 136 7 7 7 9 14 44 137 7 7 7 9 18 48 138 7 7 7 9 24 54 139 7 7 7 12 12 45 140 7 7 7 12 14 47 141 7 7 7 12 18 51 142 7 7 7 12 24 57 143 7 7 7 14 14 49 144 7 7 7 14 18 53 145 7 7 7 14 24 59 146 7 7 7 18 18 57 147 7 7 9 9 9 41 148 7 7 9 9 12 44 149 7 7 9 9 14 46 150 7 7 9 9 18 50 151 7 7 9 9 24 56 152 7 7 9 12 12 47 153 7 7 9 12 14 49 154 7 7 9 12 18 53 155 7 7 9 12 24 59 156 7 7 9 14 14 51 157 7 7 9 14 18 55 158 7 7 9 14 24 61 159 7 7 9 18 18 59 160 7 7 12 12 12 50 161 7 7 12 12 14 52 162 7 7 12 12 18 56 163 7 7 12 12 24 62 164 7 7 12 14 14 54 165 7 7 12 14 18 58 166 7 7 12 18 18 62 167 7 7 14 14 14 56 168 7 7 14 14 18 60 169 7 9 9 9 9 43 170 7 9 9 9 12 46 171 7 9 9 9 14 48 172 7 9 9 9 18 52 173 7 9 9 9 24 58 174 7 9 9 12 12 49 175 7 9 9 12 14 51 176 7 9 9 12 18 55 177 7 9 9 12 24 61 178 7 9 9 14 14 53 179 7 9 9 14 18 57
MULTI TYPE
5, 6 ROOMS TYPE
- 7 -
MULTI TYPE
5, 6 ROOMS TYPE
AOYG45LBLA6
No. Room 1 Room 2 Room 3 Room 4 Room 5 Room 6 Total
180 7 9 9 18 18 61 181 7 9 12 12 12 52 182 7 9 12 12 14 54 183 7 9 12 12 18 58 184 7 9 12 14 14 56 185 7 9 12 14 18 60 186 7 9 14 14 14 58 187 7 9 14 14 18 62 188 7 12 12 12 12 55 189 7 12 12 12 14 57 190 7 12 12 12 18 61 191 7 12 12 14 14 59 192 7 12 14 14 14 61 193 9 9 9 9 9 45 194 9 9 9 9 12 48 195 9 9 9 9 14 50 196 9 9 9 9 18 54 197 9 9 9 9 24 60 198 9 9 9 12 12 51 199 9 9 9 12 14 53 200 9 9 9 12 18 57 201 9 9 9 14 14 55 202 9 9 9 14 18 59 203 9 9 12 12 12 54 204 9 9 12 12 14 56 205 9 9 12 12 18 60 206 9 9 12 14 14 58 207 9 9 12 14 18 62 208 9 9 14 14 14 60 209 9 12 12 12 12 57 210 9 12 12 12 14 59 211 9 12 12 14 14 61 212 12 12 12 12 12 60 213 12 12 12 12 14 62 214 7 7 7 7 7 7 42 215 7 7 7 7 7 9 44 216 7 7 7 7 7 12 47 217 7 7 7 7 7 14 49 218 7 7 7 7 7 18 53 219 7 7 7 7 7 24 59 220 7 7 7 7 9 9 46 221 7 7 7 7 9 12 49 222 7 7 7 7 9 14 51 223 7 7 7 7 9 18 55 224 7 7 7 7 9 24 61 225 7 7 7 7 12 12 52 226 7 7 7 7 12 14 54 227 7 7 7 7 12 18 58 228 7 7 7 7 14 14 56 229 7 7 7 7 14 18 60 230 7 7 7 9 9 9 48 231 7 7 7 9 9 12 51 232 7 7 7 9 9 14 53 233 7 7 7 9 9 18 57 234 7 7 7 9 12 12 54 235 7 7 7 9 12 14 56 236 7 7 7 9 12 18 60 237 7 7 7 9 14 14 58 238 7 7 7 12 12 12 57 239 7 7 7 12 12 14 59 240 7 7 7 12 14 14 61 241 7 7 9 9 9 9 50 246 7 7 9 9 9 12 53 247 7 7 9 9 9 14 55 248 7 7 9 9 9 18 59 242 7 7 9 9 12 12 56 243 7 7 9 9 12 14 58 244 7 7 9 9 12 18 62 245 7 7 9 9 14 14 60 249 7 7 9 12 12 12 59 250 7 7 9 12 12 14 61 251 7 7 12 12 12 12 62 252 7 9 9 9 9 9 52 253 7 9 9 9 9 12 55 254 7 9 9 9 9 14 57 255 7 9 9 9 12 12 58 256 7 9 9 9 12 14 60 257 7 9 9 12 12 12 61 258 9 9 9 9 9 9 54 259 9 9 9 9 9 12 57 260 9 9 9 9 12 12 60
NOTE:
7: 7,000Btu/h, 9: 9,000Btu/h, 12: 12,000Btu/h, 14: 14,000Btu/h, 18: 18,000Btu/h, 24: 24,000Btu/h
- 8 -

2. Specifications

2-1. Compact cassette type

Model name AUYG07LVLA AUYG09LVLA AUYG12LVLB
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V Capacity kW class 2.0 2.5 3.5 Input power W 18 23 Running current A 0.15 0.19
Cooling
Fan
Sound pressure level *
Sound power level
Heat exchanger type
Dimensions (H × W × D)
Weight
Connection pipe
Operation range
Drain hose
Cassette grille
Remote controller type Wireless (Wired [option])
NOTES:
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Airflow rate
Heating
Type × Q'ty Turbo fan × 1 Motor output W 54
Cooling
Heating
Cooling Heating 47 49 Dimensions (H × W × D) mm 210 × 1,310 × 13.3 + 210 × 1,250 × 13.3 Fin pitch mm 1.2 Rows × Stages 2 × 10 Pipe type Copper tube
Net Gross 265 × 730 × 625 Net Gross 18
Size
Method Flare
Material Hard PVC Size mm Ø 25 (I.D.), Ø 32 (O.D.)
Fin type Aluminum
Liquid Gas Ø9.52 (Ø3/8)
Cooling
Heating °C 16 to 30
Model name UTG-UFYD-W Material PS
Color
Dimensions (H × W × D)
Weight
HIGH MED 490 530 LOW 440 470 QUIET 390 410 HIGH 540 610 MED 490 530 LOW 440 470 QUIET 390 410
HIGH MED 31 33 LOW 29 31 QUIET 27 28 HIGH 34 37 MED 32 33 LOW 29 31 QUIET 27 28
Net Gross 120 × 765 × 755 Net Gross 4.5
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
mm
kg
540 610
33 37
46 49
245 × 570 × 570
15
Ø6.35 (Ø1/4)
White
(Approximate color of Munsell N 9.25/)
49 × 700 × 700
2.6
MULTI TYPE
5, 6 ROOMS TYPE
- 9 -
Model name AUYG14LVLB AUYG18LVLB
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V Capacity kW class 4.0 5.0 Input power W 28 39 Running current A 0.22 0.30
MULTI TYPE
5, 6 ROOMS TYPE
Fan
Sound pressure level *
Sound power level
Heat exchanger type
Dimensions (H × W × D)
Weight
Connection pipe
Operation range
Drain hose
Cassette grille
Remote controller type Wireless (Wired [option])
NOTES:
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
HIGH
Cooling
Airflow rate
Heating
Type × Q'ty Turbo fan × 1 Motor output W 54
Cooling
Heating
Cooling Heating 52 56 Dimensions (H × W × D) mm 210 × 1,310 × 13.3 + 210 × 1,250 × 13.3 Fin pitch mm 1.2 Rows × Stages 2 × 10 Pipe type Copper tube
Net Gross 265 × 730 × 625 Net Gross 18
Size
Method Flare
Material Hard PVC Size mm Ø 25 (I.D.), Ø 32 (O.D.)
Fin type Aluminum
Liquid Gas Ø12.70 (Ø1/2)
Cooling
Heating °C 16 to 30
Model name UTG-UFYD-W Material PS
Color
Dimensions (H × W × D)
Weight
MED 580 610 LOW 490 520 QUIET 410 410 HIGH 700 800 MED 620 710 LOW 550 600 QUIET 430 450
HIGH MED 35 37 LOW 32 33 QUIET 29 29 HIGH 40 44 MED 37 40 LOW 34 37 QUIET 29 30
Net Gross 120 × 765 × 755 Net Gross 4.5
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
mm
kg
680 750
40 42
52 54
245 × 570 × 570
15
Ø6.35 (Ø1/4)
White
(Approximate color of Munsell N 9.25/)
49 × 700 × 700
2.6
- 10 -

2-2. Mini duct type

Model name ARYG07LSLAP ARYG09LSLAP ARYG12LSLAP
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V Capacity kW class 2.0 2.5 3.5
Input power Fan
Running current A 0.29 0.33 0.38
Cooling
Fan
Recommended static pressure Pa 0 to 30
Sound pressure level *
Sound power level
Heat exchanger type
Enclosure
Dimensions (H × W × D)
Weight
Connection pipe
Operation range
Drain hose
Remote controller type Wired (Wireless [option])
NOTES:
• Values mentioned in the table are based on the following conditions:
– Static pressure: 10 Pa
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Airflow rate
Heating
Type × Q'ty Sirocco fan × 2 Motor output W 75
Cooling
Heating
Cooling Heating 53 56 57 Dimensions (H × W × D) mm 336 × 490 × 26.6 Fin pitch mm 1.3 Rows × Stages 2 × 16 Pipe type Copper tube
Material Steel sheet Color — Net Gross 250 × 930 × 580 Net Gross 19.5
Size
Method Flare
Material Hard PVC Size mm Ø 25 (I.D.), Ø 32 (O.D.)
Fin type Aluminum
Liquid Gas Ø9.52 (Ø3/8)
Cooling
Heating °C 16 to 30
HIGH MED 23 23 26 LOW 20 20 22 QUIET 18 18 18
HIGH MED 440 450 490 LOW 390 400 430 QUIET 360 360 360 HIGH 550 600 650 MED 440 450 490 LOW 390 400 430 QUIET 360 360 360
HIGH MED 26 26 27 LOW 24 24 25 QUIET 23 23 23 HIGH 29 29 31 MED 26 26 27 LOW 24 24 25 QUIET 23 23 23
W
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
33 40 47
550 600 650
29 29 31
52 54 55
198 × 700 × 450
15.5
Ø6.35 (Ø1/4)
MULTI TYPE
5, 6 ROOMS TYPE
- 11 -
Model name ARYG14LSLAP ARYG18LSLAP
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V Capacity kW class 4.0 5.0
Input power Fan
MULTI TYPE
5, 6 ROOMS TYPE
Running current A 0.58 0.49
Fan
Recommended static pressure Pa 0 to 50
Sound pressure level *
Sound power level
Heat exchanger type
Enclosure
Dimensions (H × W × D)
Weight
Connection pipe
Operation range
Drain hose
Remote controller type Wired (Wireless [option])
NOTES:
• Values mentioned in the table are based on the following conditions:
– Static pressure: 15 Pa
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
HIGH MED 44 38 LOW 30 22 QUIET 18 19
HIGH
Cooling
Airflow rate
Heating
Type × Q'ty Sirocco fan × 2 Sirocco fan × 3 Motor output W 75 80
Cooling
Heating
Cooling Heating 62 59 Dimensions (H × W × D) mm 336 × 490 × 26.6 336 × 690 × 26.6 Fin pitch mm 1.3 Rows × Stages 2 × 16 Pipe type Copper tube
Material Steel sheet Color — Net Gross 250 × 930 × 580 250 × 1,130 × 580 Net Gross 19.5 23.0
Size
Method Flare
Material Hard PVC Size mm Ø 25 (I.D.), Ø 32 (O.D.)
Fin type Aluminum
Liquid Gas Ø12.7 (Ø1/2)
Cooling
Heating °C 16 to 30
MED 640 750 LOW 530 540 QUIET 360 480 HIGH 800 940 MED 640 750 LOW 530 540 QUIET 360 480
HIGH MED 30 29 LOW 27 26 QUIET 23 23 HIGH 35 33 MED 30 29 LOW 27 26 QUIET 23 23
W
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
72 63
800 940
35 33
60 58
198 × 700 × 450 198 × 900 × 450
15.5 18.5
Ø6.35 (Ø1/4)
- 12 -

2-3. Slim duct type

Model name ARYG07LLTA ARYG09LLTA ARYG12LLTB
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V Capacity kW class 2.0 2.5 3.5 Input power W 33 49 58 Running current A 0.33 0.30 0.35
Cooling
Fan
Recommended static pressure Pa 0 to 90
Sound pressure level *
Sound power level
Heat exchanger type
Enclosure
Dimensions (H × W × D)
Weight
Connection pipe
Operation range
Drain hose
Remote controller type Wired (Wireless [option])
NOTES:
• Values mentioned in the table are based on the following conditions:
– Static pressure: 25 Pa
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Airflow rate
Heating
Type × Q'ty Sirocco fan × 2 Motor output W 80 81
Cooling
Heating
Cooling Heating 57 58 Dimensions (H × W × D) mm 294 × 500 × 26.6 294 × 500 × 39.9 Fin pitch mm 1.3 Rows × Stages 2 × 14 3 × 14 Pipe type Copper tube
Material Steel sheet Color — Net Gross 274 × 945 × 772 Net Gross 21 23
Size
Method Flare
Material Hard PVC Size mm Ø 25 (I.D.), Ø 32 (O.D.)
Fin type Aluminum
Liquid Gas Ø9.52 (Ø3/8)
Cooling
Heating °C 16 to 30
HIGH MED 490 550 600 LOW 470 500 550 QUIET 440 450 480 HIGH 550 600 650 MED 490 550 600 LOW 470 500 550 QUIET 440 450 480
HIGH MED 26 27 28 LOW 25 26 27 QUIET 24 25 26 HIGH 28 28 29 MED 26 26 28 LOW 25 25 27 QUIET 24 24 24
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
550 600 650
28 28 29
57 58
198 × 700 × 620
17 19
Ø6.35 (Ø1/4)
MULTI TYPE
5, 6 ROOMS TYPE
- 13 -
Model name ARYG14LLTB ARYG18LLTB
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V Capacity kW class 4.0 5.0 Input power W 76 73 Running current A 0.51 0.44
MULTI TYPE
5, 6 ROOMS TYPE
Fan
Recommended static pressure Pa 0 to 90
Sound pressure level *
Sound power level
Heat exchanger type
Enclosure
Dimensions (H × W × D)
Weight
Connection pipe
Operation range
Drain hose
Remote controller type Wired (Wireless [option])
NOTES:
• Values mentioned in the table are based on the following conditions:
– Static pressure: 25 Pa
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
HIGH
Cooling
Airflow rate
Heating
Type × Q'ty Sirocco fan × 2 Sirocco fan × 3 Motor output W 81
Cooling
Heating
Cooling Heating 61 59 Dimensions (H × W × D) mm 294 × 500 × 39.9 294 × 700 × 39.9 Fin pitch mm 1.3 Rows × Stages 3 × 14 Pipe type Copper tube
Material Steel sheet Color — Net Gross 274 × 945 × 772 274 × 1,145 × 772 Net Gross 23 27
Size
Method Flare
Material Hard PVC Size mm Ø 25 (I.D.), Ø 32 (O.D.)
Fin type Aluminum
Liquid Gas Ø12.70 (Ø1/2)
Cooling
Heating °C 16 to 30
MED 700 880 LOW 600 820 QUIET 480 750 HIGH 800 940 MED 700 880 LOW 600 820 QUIET 480 750
HIGH MED 30 31 LOW 28 30 QUIET 26 29 HIGH 33 33 MED 30 32 LOW 28 31 QUIET 25 29
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
800 940
32 32
60 58
198 × 700 × 620 198 × 900 × 620
19 23
Ø6.35 (Ø1/4)
- 14 -

2-4. Wall mounted type

Model name ASYG07LUCA ASYG09LUCA ASYG12LUCA ASYG14LUCA
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V Capacity kW class 2.0 2.5 3.5 4.0 Input power W 13 16 19 23 Running current A 0.13 0.14 0.17 0.20
Cooling
Fan
Sound pressure level *
Sound power level
Heat exchanger type
Enclosure
Dimensions (H × W × D)
Weight
Connection pipe
Drain hose
Operation range
Remote controller type Wireless (Wired [option])
NOTES:
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Airflow rate
Heating
Type × Q'ty Cross flow fan × 1 Motor output W 36
Cooling
Heating
Cooling Heating 53 54 55 59
Dimensions (H × W × D) mm
Fin pitch mm Main: 1.1, Sub: 1.4 Rows × Stages Main: 2 × 20, Sub: 1 × 4 Pipe type Copper tube
Material Polystyrene
Color
Net Gross 247 × 920 × 373 Net Gross 12
Size
Method Flare Material PP + LLDPE Size mm Ø13.8 (I.D.), Ø15.8 to Ø16.7 (O.D.)
Fin type Aluminum
Liquid Gas Ø9.52 (Ø3/8) Ø12.7 (Ø1/2)
Cooling
Heating °C 16 to 30
HIGH MED 520 550 600 640 LOW 470 470 530 570 QUIET 330 330 330 390 HIGH 570 600 660 710 MED 520 550 600 640 LOW 470 470 530 590 QUIET 330 330 330 430
HIGH MED 30 32 34 36 LOW 28 28 31 33 QUIET 21 21 21 25 HIGH 35 36 37 41 MED 30 32 34 36 LOW 28 28 31 34 QUIET 21 21 21 27
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
570 600 660 710
35 36 37 41
53 54 55 59
Main: 320 × 690 × 20
Sub: 84 × 690 × 13.3
(Approximate color of Munsell N 9.3)
White
282 × 870 × 185
9.5
Ø6.35 (Ø1/4)
MULTI TYPE
5, 6 ROOMS TYPE
- 15 -
Model name ASYG07LMCA ASYG09LMCA ASYG12LMCA ASYG14LMCA
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V Capacity kW class 2.0 2.5 3.5 4.0 Input power W 15 17 22 28
MULTI TYPE
Running current A 0.13 0.15 0.19 0.25
5, 6 ROOMS TYPE
Fan
Sound pressure level *
Sound power level
Heat exchanger type
Enclosure
Dimensions (H × W × D)
Weight
Connection pipe
Drain hose
Operation range
Remote controller type Wireless (Wired [option])
NOTES:
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
HIGH
Cooling
Airflow rate
Heating
Type × Q'ty Cross flow fan × 1 Motor output W 35
Cooling
Heating
Cooling Heating 51 52 55 57
Dimensions (H × W × D) mm
Fin pitch mm Main: 1.1, Sub: 1.4 Rows × Stages Main: 2 × 20, Sub: 1 × 4 Pipe type Copper tube
Material Polystyrene
Color
Net Gross 270 × 884 × 336 Net Gross 10.5
Size
Method Flare Material PP + LLDPE Size mm Ø13.8 (I.D.), Ø15.8 to Ø16.7 (O.D.)
Fin type Aluminum
Liquid Gas Ø9.52 (Ø3/8) Ø12.7 (Ø1/2)
Cooling
Heating °C 16 to 30
MED 500 520 560 600 LOW 430 430 450 530 QUIET 310 310 310 360 HIGH 560 600 660 730 MED 500 520 560 615 LOW 430 430 470 560 QUIET 330 330 330 375
HIGH MED 32 33 36 38 LOW 29 29 30 33 QUIET 21 21 21 25 HIGH 36 37 40 42 MED 32 33 36 38 LOW 29 29 31 35 QUIET 22 22 22 27
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
560 600 660 730
36 37 40 42
51 52 54 56
Main: 320 × 630 × 20 Sub: 84 × 630 × 13.3
(Approximate color of Munsell N 9.25/)
White
268 × 840 × 203
8.5
Ø6.35 (Ø1/4)
- 16 -
Model name ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V Capacity kW class 2.0 2.5 3.5 4.0 Input power W 15 17 22 28 Running current A 0.13 0.15 0.19 0.25
Cooling
Fan
Sound pressure level *
Sound power level
Heat exchanger type
Enclosure
Dimensions (H × W × D)
Weight
Connection pipe
Drain hose
Operation range
Remote controller type Wireless (Wired [option])
NOTES:
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Airflow rate
Heating
Type × Q'ty Cross flow fan × 1 Motor output W 35
Cooling
Heating
Cooling Heating 51 52 55 57
Dimensions (H × W × D) mm
Fin pitch mm Main: 1.1, Sub: 1.4 Rows × Stages Main: 2 × 20, Sub: 1 × 4 Pipe type Copper tube
Material Polystyrene
Color
Net Gross 270 × 925 × 336 Net Gross 11.0
Size
Method Flare Material PP + LLDPE Size mm Ø13.8 (I.D.), Ø15.8 to Ø16.7 (O.D.)
Fin type Aluminum
Liquid Gas Ø9.52 (Ø3/8) Ø12.7 (Ø1/2)
Cooling
Heating °C 16 to 30
HIGH MED 500 520 560 600 LOW 430 430 450 530 QUIET 310 310 310 360 HIGH 560 600 660 730 MED 500 520 560 615 LOW 430 430 470 560 QUIET 330 330 330 375
HIGH MED 32 33 36 38 LOW 29 29 30 33 QUIET 21 21 21 25 HIGH 36 37 40 42 MED 32 33 36 38 LOW 29 29 31 35 QUIET 22 22 22 27
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
560 600 660 730
36 37 40 42
51 52 54 56
Main: 320 × 630 × 20
Sub: 84 × 630 × 13.3
(Approximate color of Munsell N 9.25/)
White
270 × 870 × 204
8.5
Ø6.35 (Ø1/4)
MULTI TYPE
5, 6 ROOMS TYPE
- 17 -
MULTI TYPE
5, 6 ROOMS TYPE
Model name ASYG18LFCA ASYG24LFCA ASYG24LFCC
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V Capacity kW class 5.0 7.0 Input power W 37 69 Running current A 0.33 0.53
Cooling
Fan
Sound pressure level *
Sound power level
Heat exchanger type
Enclosure
Dimensions (H × W × D)
Weight
Connection pipe
Drain hose
Operation range
Remote controller type Wireless (Wired [option])
NOTES:
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Airflow rate
Heating
Type × Q'ty Cross flow fan ×1 Motor output W 42 65
Cooling
Heating
Cooling Heating 58 64
Dimensions (H × W × D) mm
Fin pitch mm Main: 1.2, Sub: 1.4 Rows × Stages Main: 2 × 18, Sub: 1 × 4 Main: 2 × 18, Sub: 1 × 4 + 1 × 4 Pipe type Copper tube
Material Polystyrene
Color
Net Gross 329 × 1,090 × 420 Net Gross 18
Size
Method Flare Material PVC Size mm Ø12 (I.D.), Ø16 (O.D.)
Fin type Aluminum
Liquid Gas Ø12.70 (Ø1/2) Ø15.88 (Ø5/8)
Cooling
Heating °C 16 to 32
HIGH MED 740 900 LOW 620 740 QUIET 550 620 HIGH 900 1,100 MED 740 900 LOW 620 740 QUIET 550 620
HIGH MED 37 42 LOW 33 37 QUIET 26 33 HIGH 42 48 MED 37 42 LOW 33 37 QUIET 25 33
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
900 1,120
43 49
58 64
Main: 378 × 832 × 26.6
Sub: 84 × 832 × 13.3
(Approximate color of Munsell N 9.25/)
White
320 × 998 × 238
14
Ø6.35 (Ø1/4)
- 18 -

2-5. Floor/Ceiling type

Model name ABYG14LVTA ABYG18LVTB
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V Capacity kWh class 4.0 5.0 Input power W 26 47 Running current A 0.21 0.36
Cooling
Fan
Sound pressure level *
Sound power level
Heat exchanger type
Enclosure
Dimensions (H × W × D)
Weight
Connection pipe
Drain hose
Operation range
Remote controller type Wireless (Wired [option])
NOTES:
• The protective function might work when using it outside the operation range.
• *Sound pressure level:
– Measured values in manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Airflow rate
Heating
Type × Q'ty Sirocco fan × 2 Motor output W 80
Cooling
Heating
Cooling Heating 51 55 Dimensions (H × W × D) mm 252 × 800 × 26.6 252 × 800 × 39.9 Fin pitch mm 1.2 1.3 Rows × Stages 2 × 12 3 × 12 Pipe type Copper tube
Material ABS
Color
Net Gross 320 × 1,150 × 790 Net Gross 36
Size
Method Flare Material Hard PVC Size mm Ø25 (I.D.), Ø32 (O.D.)
Fin type Aluminum
Liquid Gas Ø12.70 (Ø1/2)
Cooling
Heating °C 16 to 30
HIGH MED 590 700 LOW 540 560 QUIET 480 500 HIGH 640 780 MED 590 700 LOW 540 560 QUIET 480 500
HIGH
MED
LOW
QUIET
HIGH
MED
LOW
QUIET
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
640 780
36 (Under ceiling) 39 (Floor console)
34 (Under ceiling) 37 (Floor console)
33 (Under ceiling) 36 (Floor console)
29 (Under ceiling) 32 (Floor console)
36 (Under ceiling) 39 (Floor console)
34 (Under ceiling) 37 (Floor console)
33 (Under ceiling) 36 (Floor console)
29 (Under ceiling) 32 (Floor console)
51 55
(Approximate color of Munsell N 9.25/)
White
199 × 990 × 655
27
Ø6.35 (Ø1/4)
41 (Under ceiling) 44 (Floor console)
38 (Under ceiling) 41 (Floor console)
34 (Under ceiling) 37 (Floor console)
32 (Under ceiling) 35 (Floor console)
41 (Under ceiling) 44 (Floor console)
38 (Under ceiling) 41 (Floor console)
34 (Under ceiling) 37 (Floor console)
32 (Under ceiling) 35 (Floor console)
MULTI TYPE
5, 6 ROOMS TYPE
- 19 -

2-6. Floor type

Model name AGYG09LVCA AGYG12LVCA AGYG14LVCA
Power supply 1Ø 230 V ~50 Hz Available voltage range 198—264 V
MULTI TYPE
Capacity kW class 2.5 3.5 4.0
5, 6 ROOMS TYPE
Input power W 16 20 23 Running current A 0.15 0.18 0.20
Fan
Sound pressure level *
Sound power level
Heat exchanger type
Enclosure
Dimensions (H × W × D)
Weight
Connection pipe
Drain hose
Operation range
Remote controller type Wireless (Wired [option])
NOTES:
• The protective function might work when using it outside the operation range.
• *Sound pressure level:
– Measured values in manufacturer’s anechoic chamber. – Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
HIGH
Cooling
Airflow rate
Heating
Type × Q'ty Cross flow fan × 2 Motor output W 16
Cooling
Heating
Cooling Heating 52 55 56 Dimensions (H × W × D) mm 378 × 550 × 26.6 Fin pitch mm 1.2 Rows × Stages 2 × 18 Pipe type Copper tube
Material Polystyrene
Color
Net Gross 700 × 820 × 310 Net Gross 17
Size
Method Flare Material PVC Size mm Ø13.8 (I.D.), Ø16.7 (O.D.)
Fin type Aluminum
Liquid Gas Ø9.52 (Ø3/8) Ø12.70 (Ø1/2)
Cooling
Heating °C 16 to 30
MED 440 490 520 LOW 360 380 400 QUIET 270 270 270 HIGH 530 600 650 MED 460 510 540 LOW 380 410 430 QUIET 270 270 270
HIGH MED 34 36 38 LOW 28 30 31 QUIET 22 22 22 HIGH 39 42 44 MED 35 38 39 LOW 30 32 33 QUIET 22 22 22
m3/h
dB (A)
dB (A)
mm
kg
mm (in)
°C 18 to 32
%RH 80 or less
530 600 650
39 42 44
52 55 56
(Approximate color of Munsell N 9.25/)
White
600 × 740 × 200
14
Ø6.35 (Ø1/4)
- 20 -

3. Dimensions

530: Hanging bolt position
102
135
250
700
700
75
30
30
262
540: Hanging bolt position
570: Indoor unit
580 to 660
: Ceiling openings
Cassette grille mounting state
Top view
150 to 200
Min. 450
Min. 450
Service access
Side view
215
123
58
114
146
108
102
245
30
40
99
Drain port
Control box
Ceiling
Drain port
Be sure to leave
service access
for future service at the designated position.
Bottom view
30
49
Side view
Unit: mm

3-1. Compact cassette type

¢ Models: AUYG07LVLA, AUYG09LVLA, AUYG12LVLB,
AUYG14LVLB, and AUYG18LVLB
MULTI TYPE
5, 6 ROOMS TYPE
- 21 -
¢
1,000 or more
1,000 or more
1,800 or more
262 or more
Strong and durable ceiling
Obstruction
Floor
Unit: mm
100 or more*
Unit: mm
MULTI TYPE
5, 6 ROOMS TYPE
Installation space
Maximum height from floor to ceiling (Unit: mm)
Model name AUYG07LVLA AUYG09LVLA Standard mode 2,700
High ceiling mode 3,000
AUYG12LVLB AUYG14LVLB AUYG18LVLB
3-way direction setting
NOTES:
• *: When installing the indoor unit, be careful about the maintenance space.
• To set “3-direction”, optional Air outlet shutter plate (UTR-YDZB) must be installed, and the “outlet-direction” need to be switched to “3-way” by remote controller.
• The ceiling height cannot be set in the 3-way outlet mode. Therefore, ceiling height setting change by function setting 20 is prohibited. For details, refer to "Contents of function setting" on page 241.
- 22 -