AIR CONDITIONER
Wall Mounted Type
OPERATING MANUAL
Contents
Safety Precautions ............................................................... 1
Indoor Unit Overview and Operations .................................. 2
Remote Controller Overview and Operations ....................... 3
Care and Cleaning................................................................ 5
Troubleshooting .................................................................... 6
Indoor Unit
ASVG09LLCA
ASVG12LLCA
Outdoor Unit
AOVG09LLCA
AOVG12LLCA
Safety Precautions
To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply
following safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classifi ed as follows:
WARNING CAUTION
This mark warns of death or serious injury. This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.
Operating Range .................................................................. 6
Before using this product, read these instructions
thoroughly and keep this manual for future reference.
This mark denotes an action that is COMPULSORY.
English
Français
Español
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
• This unit contains no user-serviceable parts. Always consult
authorized service personnel for repairing, installation, and
relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or fi re.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should only be replaced by authorized
service personnel.
• Provide occasional ventilation during use.
• Always operate the unit with air fi lters installed.
• Ensure that any electronic equipment is at least 1 meter
away from either the indoor unit or outdoor unit.
• Unplug the power supply cable when not using the indoor
unit for an extended period.
• After long period of use, check whether the installation stand
does not deteriorate to prevent the unit from falling down.
• The airfl ow direction and the room temperature should be
carefully considered when you use this product in a room
with infants, children, elderly or sick persons.
• Do not direct the airfl ow at fi replaces or heating apparatus.
• Do not block or cover the intake grille and the outlet port.
• Do not apply any heavy pressure to radiator fi ns.
• Do not climb on, place objects on, or hang objects from the unit
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan
WARNING
CAUTION
.
• In the event of refrigerant leakage, be sure to keep away
from fi re or any fl ammables, and consult authorized service
personnel.
• If you see lightning or hear thunder, there might be a
lightning strike.
To prevent electric shock hazard, turn off the air conditioner
by using the remote controller, and do not touch the unit or
the power plug during thunderstorm.
• Do not install the unit in area fi lled with mineral oil such as a
factory or area containing a large amount of splashed oil or
steam such as a kitchen.
• Do not start or stop the operation of this product by inserting
or pulling out the power plug, or by turning on or off the
circuit breaker.
• Do not use infl ammable gases near the unit.
• Do not expose yourself directly to the cooling airfl ow for
many hours.
• Do not insert your fi ngers or any other objects into outlet
port, open panel, or intake grille.
• Do not operate with wet hands.
• Do not place vase or water container on the unit.
• Do not place any other electrical products or household
belongings under indoor unit or outdoor unit.
Dripping condensation from the unit might get them wet, and
may cause damage or malfunction of your property.
• Do not expose the unit directly to water.
• Do not use this product for preservation of food, plants,
animals, precision equipment, art work, or other objects. This
may cause quality deterioration of those items.
• Do not expose animals or plants to the direct airfl ow.
• Do not drink the drainage from the air conditioner.
• Do not pull the power supply cable to disconnect the plug.
• Do not touch the aluminum fi ns of heat exchanger built-in
the indoor or outdoor unit to avoid personal injury when you
install or maintain the unit.
PART NO. 9332621013
En-1
Indoor Unit Overview and Operations
1 Intake grille
Before starting operation, make sure that the intake grille has been
shut completely. Incomplete closing might have an effect on the
proper working or performance of the product.
2 Manual AUTO button
Use when you lost the remote controller or remote control malfunction
occurs.
Status Action Mode or operation
In operation Press more than 3 seconds. Stop
Stopping Press more than 3 seconds and
After cleaning Press less than 3 seconds. Filter indicator reset
*:To stop forced cooling, press this button or START/STOP button on
the remote controller.
less than 10 seconds.
Press more than 10 seconds.
(Only for servicing.*)
3 Front panel
4 Vertical airfl ow direction louver
Each time you press SET button on the remote controller, the angle
of the vertical airfl ow direction louver moves as follows:
COOL or DRY mode
1
2
3
4
5
6
7
• Do not adjust by hand.
• At the beginning of AUTO or HEAT mode, they may stay position 1
for a while for adjustment.
• If you set the angle to position 5–7 for more than 30 minutes in
COOL or DRY mode, they automatically return to position 4.
In COOL or DRY mode, if the angle is set to position 5–7 for many hours,
condensation may be formed, and the drips may wet your property
**
12
*: Default setting in each mode.
3
5 Drain hose
AUTO
Forced cooling
4
HEAT mode
5
76
.
1
11
10
9
8
11
Air fi lter
Easy-to-care air fi lters resist mildew growth.
Indoor unit accessories
2
3
4
5
6
7
See page 5
6 Remote control signal receiver
CAUTION
For appropriate signal transmission between remote controller and
the indoor unit, keep the signal receiver away from following items
- Direct sunlight or other strong light
- Flat-panel television screen
In rooms with instantaneous fl uorescent lights, such as in-
verter type ones, the signal may not be transmitted properly. In
such a case, consult the store that you purchased the product
7 ECONOMY indicator (green)
Lights in ECONOMY operation.
8 TIMER indicator (orange)
Lights in TIMER operation, and blinks slowly when the timer setting
error is detected.
As for the timer setting error, refer to “Auto-restart function” on page 4.
9 OPERATION indicator (green)
Lights in normal operation, and blinks slowly in automatic defrosting
operation.
10
Horizontal airfl ow direction louvers
CAUTION
Before you adjust the horizontal airfl ow direction, make sure that
the vertical airfl ow direction louver has been stopped completely
Adjust two knobs by hand.
.
BatteriesRemote controller Tapping screw
:
Take care to prevent infants and small children from accidentally swallowing the batteries.
.
Notes:
• Use specifi ed type of battery only.
• Do not use new battery and used battery together.
• Batteries can be used about 1 year in ordinary use.
• If the remote control range noticeably got shorten, replace the
batteries, and press RESET button.
Battery (AAA/R03/LR03 × 2) loading
(M3×12 mm)
WARNING
1
3
Remote controller
holder
2
En-2
OPERATING MANUAL