Wall Mounted 7, 9, 12, 18 and 24,000 BTUs
ASU7RLF1, ASU9RLF1, ASU9RLS2, ASU12RLF1, ASU12RLS2, ASU15RLS2,
ASU18RLF, ASU24RLF
!
W
E
N
Nominal Cooling BTU/h
Nominal Heating BTU/h
Voltage/Frequency/Phase
Air Circ. C.F.M. (m
dB(A) (Clg/Htg): Hi
Running Current
Rated (A): Cooling
Power Use Rated (w): Clg
Fan Speeds Stage
Air Direction: Horizontal
Primary Air Filter
Ion Deodorizing Filter
Apple-Catechin Filter
Connection Method
Conn. Pipe Diameter Inch
Net Weight lbs. (kg)
Dims: Height Inch (mm)
Width Inch (mm)
Depth Inch (mm)
3
/h): Hi
Medium
Low
Quiet
Noise Level
Medium
Low
Quiet
Heating
Htg
Vertical
Refrigerant
ASU7, 9, 12RLF1 ASU18, 24RLF
ASU9, 12, 15RLS2
Designer Series
ASU7RLF1
Heat Pump
NEW! NEW! NEW!
7,000 9,000 12,000 18,000 24,000 9,000 12,000 14,000
8,100 10,200 13,500 20,000 27,000 10,200 13,500 16,300
208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Clg 330 (560)
Htg 330 (560)
Clg 294 (500)
Htg 294 (500)
Clg 253 (430)
Htg 253 (430)
Clg 182 (310)
Htg 194 (330)
36/36 37/37 40/40 43/44 49/48 36/36 37/37 41/41
32/32 33/33 36/36 37/37 42/42 32/32 34/34 36/36
29/29 29/29 30/31 33/33 37/37 28/28 31/31 33/34
21/22 21/22 21/22 31/31 33/33 21/21 21/21 25/27
0.13 0.15 0.19 0.32 0.53 0.14 0.17 0.20
0.13 0.15 0.19 0.32 0.53 0.14 0.17 0.20
15 17 22 41 69 16 19 23
15 17 22 41 69 16 19 23
4+auto 4+auto 4+auto 4+auto 4+auto 4+auto 4+auto 4+auto
Manual Manual Manual Auto Auto Manual Manual Manual
Auto Auto Auto Auto Auto Auto Auto Auto
Washable Washable Washable Washable Washable Washable Washable Washable
Disposable Disposable Disposable Disposable Disposable Disposable Disposable Disposable
Disposable Disposable Disposable Disposable Disposable Disposable Disposable Disposable
Flare Flare Flare Flare Flare Flare Flare Flare
suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4 suc 5/8 dis 1/4 suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4
19 (8.5) 19 (8.5) 19 (8.5) 31 (14) 31 (14) 21 (9.5) 21 (9.5) 21 (9.5)
10-1/2 (268) 10-1/2 (268) 10-1/2 (268) 12-5/8 (320) 12-5/8 (320)
33-1/16 (840) 33-1/16 (840) 33-1/16 (840) 39-1/4 (998) 39-1/4 (998) 34-1/4 (870) 34-1/4 (870) 34-1/4 (870)
8 (203) 8 (203) 8 (203) 9 (228) 9 (228) 7-1/4 (185) 7-1/4 (185) 7-1/4 (185)
R410A R410A R410A R410A R410A R410A R410A R410A
* ESP feature not compatible in multi-zone configurations. ^Height when front panel is open.
ASU9RLF1
Heat Pump
Clg 353 (600)
Htg 353 (600)
Clg 306 (520)
Htg 306 (520)
Clg 253 (430)
Htg 253 (430)
Clg 182 (310)
Htg 194 (330)
ASU12RLF1
Heat Pump
Clg 388 (660)
Htg 388 (660)
Clg 330 (560)
Htg 330 (560)
Clg 265 (450)
Htg 277 (470)
Clg 182 (310)
Htg 194 (330)
ASU18RLF
Heat Pump
Clg 542 (920)
Htg 542 (920)
Clg 436 (740)
Htg 436 (740)
Clg 365 (620)
Htg 365 (620)
Clg 324 (550)
Htg 324 (550)
ASU24RLF
Heat Pump
Clg 659 (1,120)
Htg 647 (1,100)
Clg 530 (900)
Htg 530 (900)
Clg 436 (740)
Htg 436 (740)
Clg 365 (620)
Htg 365 (620)
ASU9RLS2
Heat Pump*
Clg 353 (600)
Htg 353 (600)
Clg 324 (550)
Htg 324 (550)
Clg 277 (470)
Htg 277 (470)
Clg 194 (330)
Htg 194 (330)
11-1/8 (282)
13-1/4^ (337^)
ASU12RLS2
Heat Pump*
Clg 388 (660)
Htg 388 (660)
Clg 353 (600)
Htg 353 (600)
Clg 312 (530)
Htg 312 (530)
Clg 194 (330)
Htg 194 (330)
11-1/8 (282)
13-1/4^ (337^)
ASU15RLS2
Heat Pump*
Clg 418 (710)
Htg 418 (710)
Clg 377 (640)
Htg 377 (640)
Clg 336 (570)
Htg 347 (590)
Clg 230 (390)
Htg 253 (430)
11-1/8 (282)
13-1/4^ (337^)
Built In FiltrationStandard Features
Wireless Remote Control*
Apple Catechin Filter
Ion Deodorizing Filter
Sleep Timer
24-Hour Timer
Dry Mode
Auto Louver: 4-Way**
Auto Mode
Minimum Heat Mode
Long-life+Ion Deodorization Filter
The filter deodorizes by powerfully
decomposing absorbed odors using
the oxidizing and reducing effects of
ions generated by the ultra-fineparticle ceramic.
+ The filter can be used for approximately 3 years if it is washed with water when dirty to restore it's surface action.
Auto Restart/Reset
Power Diffuser**
* Features vary by model and therefore standard wireless remote controls should be used with the models they are
associated with.
**Feature of models ASU18, 24RLF only.
6
Apple-Catechin Filter
Dust, mold spores and microorganisms are absorbed onto the
filter by static electricity and growth
is inhibited and deactivated.
5