TECHNICAL SPECIFICATIONS
Rated
Range
Rated
Range
(1)
Capacity
Input
Current
Max
Running
Current
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Starting Current
EER (Cooling)
AEER
COP (Heating)
ACOP
Moisture Removal
Air Circulation
Indoor (High Fan)
Outdoor
Power Supply Outdoor
Sound Pressure
Level
Sound Power
Level
Weight (Net)
Dimensions
HxWxD (mm)
Connection Pipe
Sizes
Drain Pipe Sizes
1 = The maximum current is the maximum value when operated within the operation range.
Indoor (High Fan)
Outdoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Liquid
Gas
Internal
External
kW 9.4
kW 2.9 – 11.2
Kw 10.3
kW 2.7 – 11.7
kW 2.78
kW 2.84
A 11.7
A 12.9
A 19.5
A 20.5
A 12.9
3.38
3.476
3.63
3.735
l/h
l/s 389
l/s 1139
240V - 1Ph - 50Hz
dB 51
dB 51
dB 65
Kg 18
Kg 74
340 x 1150 x 280
914 × 970 × 370
mm Ø 9.52
mm Ø 15.88
mm
mm
13.8
20
Reverse Cycle
Cooling/Heating capacities are based on
the following conditions (AS3823).
Cooling
Indoor temp : 27°C DB / 19°CWB
Outdoor temp : 35°C DB / 24°C WB
Heating
Indoor temp : 20°C DB / 15°C WB
Outdoor temp : 7°C DB / 6°C WB
Running current is at rated conditions
(AS3823) and does not include
compressor start-up or variations in
power supply and load conditions.
All wiring specifications are minimum
recommendations. Please consult
AS/NZS 3000 and your local wiring rules
for clarification of cable and circuit
requirements.
Suitable access for warranty & service is
required.
SOUND POWER LEVELS measured in
accordance to AS1217.
Specifications and design are subject to
change without notice. Please check
with your dealer.