Fujitsu ASTG18KUCA, ASTG09KUCA, ASTG12KUCA User Manual

AIR CONDITIONER Wall Mounted Type
ASTG09KUCA
R32
REFRIGERANT
This Air Conditioner contains and operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation, regulations, codes, installation & operation manuals, before the installation, maintenance or service of this product.
OPERATING MANUAL
Contents
Safety Precautions ..........................................................En-1
Indoor Unit Overview and Operations .............................En-3
Remote Controller Overview and Operations ..................En-4
Timer Operation...............................................................En-6
Human Sensor (Energy Saving) ......................................En-8
Demand Response and Indoor Unit Operation ...............En-8
General Informations on Operation .................................En-9
Care and Cleaning.........................................................En-10
Troubleshooting ............................................................. En-12
ASTG12KUCA ASTG18KUCA
Before using this product, read these instructions thoroughly and keep this manual for future reference.
Safety Precautions
To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply to the following safety precautions. Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classifi ed as follows:
WARNING CAUTION
This mark warns of death or serious injury. This mark warns of injury or damage to property.
• Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
CAUTION
CAUTION
CAUTION
• The appliance shall be installed, operated and stored in a
room with a fl oor area larger than 1.54m2 (18 model only)
• The appliance contains no user-serviceable parts. Always consult authorized service personnel for repairing, installation, and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or fi re.
• In the event of a malfunction such as burning smell, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should only be replaced by authorized
service personnel.
• In the event of refrigerant leakage, be sure to keep away from fi re or any fl ammables, and consult authorized service personnel.
• If you see lightning or hear thunder, there might be a lightning strike.
To prevent electric shock hazard, turn off the air conditioner
by using the remote controller, and do not touch the unit or the power plug during thunderstorm.
This symbol shows that this appliance uses a fl ammable refrigerant. If the refrigerant is leaked and exposure to an external ignition source, there is a risk of fi re.
This symbol shows that the Operation Manual should be read carefully.
This symbol shows that a service personnel should be handling this equipment with reference to the Installation Manual.
This symbol shows that information is available such as the Operating Manual or Installation Manual.
WARNING
This mark denotes an action that is COMPULSORY.
• The appliance shall be stored in a room without continuously
operating ignition sources (for example: open fl ames, an operating gas appliance or an operating electric heater).
• The appliance shall be stored in a well-ventilated area.
• Be aware that refrigerants may not contain an odour.
• The appliance shall be stored so as to prevent mechanical damage from occurring.
• Disposing of the product shall be done properly, in compliance with national or regional regulations.
• During transportation or relocation of the indoor unit, pipes shall be covered with the wall hook bracket for protection. Do not move the appliance by holding the indoor unit pipes. (The stress applied to the pipe joints may cause the ammable gas to leak during operation).
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
(continued)
PART No. 9319356082
9319356082_01_OM_EN.indd 19319356082_01_OM_EN.indd 1 7/1/2013 11:02:30 AM7/1/2013 11:02:30 AM
En-1
Safety Precautions (continued)
• Do not install the unit in area fi lled with mineral oil such as a
factory or area containing a large amount of splashed oil or steam such as a kitchen.
• Do not start or stop the operation of this product by inserting or pulling out the power plug, or by turning on or off the circuit breaker.
• Do not use infl ammable gases near the unit.
• Do not expose yourself directly to the cooling airfl ow for many hours.
• Provide occasional ventilation during use.
• Always operate the unit with air fi lters installed.
• Ensure that any electronic equipment is at least 1 meter away from either the indoor unit or outdoor unit.
• Unplug the power supply cable when not using the indoor unit for an extended period.
• After long period of use, check whether the installation stand does not deteriorate to prevent the unit from falling down.
• The airfl ow direction and the room temperature should be carefully considered when you use this product in a room with infants, children, elderly or sick persons.
• Do not direct the airfl ow at fi replaces or heating apparatus.
• Do not block or cover the intake grille and the outlet port.
• Do not apply any heavy pressure to radiator fi ns.
• Do not climb on, place objects on, or hang objects from the unit
WARNING
CAUTION
.
• Do not insert your fi ngers or any other objects into outlet
port, open panel, or intake grille.
• Do not operate with wet hands.
• Do not use means to accelerate the defrosting process or to clean the appliance, other than those recommended by the manufacturer.
• Do not pierce or burn.
• Do not place vase or water container on the unit.
• Do not place any other electrical products or household belongings under indoor unit or outdoor unit.
Dripping condensation from the unit might get them wet, and
may cause damage or malfunction of your property.
• Do not expose the unit directly to water.
• Do not use this product for preservation of food, plants, animals, precision equipment, art work, or other objects. This may cause quality deterioration of those items.
• Do not expose animals or plants to the direct airfl ow.
• Do not drink the drainage from the air conditioner.
• Do not pull the power supply cable to disconnect the plug.
• Do not touch the aluminum fi ns of heat exchanger built-in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit.
Indoor unit accessories
Remote controller
Batteries Air cleaning fi lters Filter holders
Remote controller holder
Tapping screws (M3 × 12 mm)
Battery (R03/LR03/AAA × 2) loading and remote controller preparation
3
1
2
Remote controller holder installation
321
Screws
Insert
WARNING
Take care to prevent infants and young children from acciden­tally swallowing the batteries.
CAUTION
• Do not attempt to recharge dry batteries.
• Do not use dry batteries that has been recharged.
4
9
5
Slide up
7
6
8
5
Press CLOCK ADJUST button to start clock setting.
6
Set the day of the week by pressing SELECT button (Monday to
Sunday). *By pressing the TEMP. () buttons, the time indicator can be changed from a 24-hour to a 12-hour clock.
7
Press NEXT button to continue.
8
Set the time by pressing SELECT button.
Pressing  or  changes the value by the minute. Pressing down on  or  changes the value by 10 minutes.
En-2
9319356082_01_OM_EN.indd 29319356082_01_OM_EN.indd 2 7/1/2013 11:02:44 AM7/1/2013 11:02:44 AM
OPERATING MANUAL
9
To complete, press the SEND button close to the indoor unit.
Settings may not be properly sent if pressed from a distance.
Notes:
• Use specifi ed type of batteries only.
• Do not mix different types or new and used batteries together.
• Batteries can be used about 1 year in ordinary use.
• If the remote control range noticeably shortens, replace the batter­ies, and press RESET button as shown in page 5.
Indoor Unit Overview and Operations
AIR CONDITIONER Wall Mounted Type
1 Intake grille
Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing may have an effect on the proper
function or performance of the product.
2 MANUAL AUTO button
Use when the remote controller is lost or there is a malfunction.
Status Action Mode or operation
In operation Press more than 3 seconds. Stop
Stopping Press more than 3 seconds and
less than 10 seconds.
Press more than 10 seconds. (Only for servicing.*)
After cleaning Press less than 3 seconds. Filter indicator reset
*:To stop forced cooling, press this button or START/STOP button on
the remote controller.
AUTO
Forced cooling
3 Front panel
4 Human Sensor
Used for Energy Saving Program. Controls temperature setting by detecting people in the room.
See page 8
5 Vertical airfl ow direction louver
Each time you press SET button on the remote controller, the angle of the vertical airfl ow direction louver moves as follows:
COOL or DRY mode HEAT mode
1
2
3
4
5
6
7
• Do not adjust by hand.
• At the beginning of AUTO or HEAT mode, they may stay on position 1 for a while for adjustment.
• If the angle is set to position 4–7 for more than 30 minutes in COOL or DRY mode, the louver will automatically return to position 3.
• Keeping the position 4-7 during COOL or DRY mode may cause condensation to form, and the drops may damage your property.
**
12
*: Default setting in each mode.
3
4
6 Drain hose
7 Remote controller signal receiver
CAUTION
For appropriate signal transmission between remote controller and indoor unit, keep the signal receiver away from the following items
- Direct sunlight or other strong lights
- Flat-panel television screen
In rooms with instantaneous fl uorescent lights, such as in- verter type ones, the signal may not be transmitted properly. In such a case, consult the store of purchase.
2
1
4
5
13
6
12
7
11
8
10
9
765
:
10 OPERATION indicator (green)
Lights in normal operation, and blinks slowly in Automatic defrosting operation. Blinks during Demand Response operation. For details, refer to page
8.
11
Horizontal airfl ow direction louvers
CAUTION
Before you adjust the horizontal airfl ow direction, make sure that the vertical airfl ow direction louver has been stopped completely
Adjust two knobs by hand.
12
Air fi lter
13
Air cleaning fi lters
Purify or deodorize the air, and provide fresh airfl ow.
See page 10
See page 11
.
8 ECONOMY indicator (green)
Lights in ECONOMY operation and in 10 °C HEAT operation.
9 TIMER indicator (orange)
Lights in TIMER operation, and blinks slowly when the timer setting error is detected. For details, refer to “Auto-restart function” on page 9.
OPERATING MANUAL
9319356082_01_OM_EN.indd 39319356082_01_OM_EN.indd 3 7/1/2013 11:02:46 AM7/1/2013 11:02:46 AM
En-3
Remote Controller Overview and Operations
CAUTION
• To prevent malfunction or damage of the remote controller:
- Place remote controller at where will not be exposed to direct sunlight or excessive heat.
- Remove batteries if the product is not going to be used for an extended period.
- Exhausted batteries must be removed immediately, and be disposed according to the local laws and regulations of your region.
• If leaking battery fl uid comes in contact with your skin, eyes,
or mouth, immediately rinse with plenty of clean water, and consult your physician.
• Obstacles such as a curtain or wall between the remote controller and the indoor unit may affect the appropriate signal transmission.
• Do not apply strong shocks to the remote controller.
• Do not pour water on the remote controller.
23
2
22
21
20
19
18
17
8
9
10
11
12
13
14
15
16
You can quickly start operation with the following 3 steps:
1 START/STOP button
2 MODE button
Switches operation mode in following order.
AUTO COOL DRY FAN HEAT
Notes in HEAT mode:
• At the beginning of the operation, the indoor unit operates at very low fan speed for about 3–5 minutes for preparation, then switches to the selected fan speed.
• Automatic defrosting operation overrides the heating operation when necessary.
3 TEMP. (temperature) buttons
Sets the desired temperature. In COOL or DRY mode, the temperature needs to be set lower than the current room temperature. In HEAT mode, the temperature needs to be set higher than the current room temperature. Otherwise, corresponding operation mode may not start.
Temperature setting range
AUTO/COOL/DRY 18–30 °C
HEAT 16–30 °C
Notes: Temperature control is not available in FAN mode.
7
4
6
3
5
1
4 Remote controller display
In this section, all the possible indicators are displayed for description. In actual operation, the display is linked with the button operation, and only shows the necessary indicators for each setting.
5 POWERFUL button
Activates the POWERFUL operation. The unit will operate at maximum power and strong airfl ow to quickly cool down or warm up the room. When activated, the indoor unit will emit 3 short beeps. To turn off, press the POWERFUL button again. The indoor unit will then emit 2 short beeps. POWERFUL operation is automatically turned off in the following situations:
• Adjusted room temperature reaches the set temperature in COOL, DRY, or HEAT mode.
• 20 minutes have passed after the POWERFUL operation mode has been set.
Even in situations above, the POWERFUL operation will not automatically turn off unless it has run for a certain amount of time.
Notes:
• The airfl ow direction and the fan speed are controlled automatically.
• This operation cannot be performed simultaneously with ECONOMY operation.
• POWERFUL operation will override the OUTDOOR UNIT LOW NOISE, ENERGY SAVING functions. Both functions, if set, will start after the POWERFUL operation is turned off.
6 10 °C HEAT button
Starts 10 °C HEAT operation that mainains the room temperature at 10 °C so as to prevent the room temperature to drop too low. After pressing the button to start the 10 °C HEAT operation, the indoor unit emits 2 short beeps and the ECONOMY indicator (green) will turn on. To turn off, press the START/STOP button. The Economy indicator will turn off.
Notes:
• In 10 °C HEAT operation mode, only the vertical airfl ow direction can be adjusted by using the SET button.
• HEAT mode will not be performed if the room temperature is warm enough.
(continued)
En-4
9319356082_01_OM_EN.indd 49319356082_01_OM_EN.indd 4 7/1/2013 11:02:47 AM7/1/2013 11:02:47 AM
OPERATING MANUAL
AIR CONDITIONER Wall Mounted Type
Remote Controller Overview and Operations (continued)
7 Signal transmitter
Aim at the signal receiver of the indoor unit properly.
• Signal transmit indicator on the remote controller display shows that the signal from the remote controller is being transmitted.
• Operating range is approximately 7 m.
• You will hear a beep if the transmitted signal has been sent properly. If there is no beep, press the button on the remote controller again.
8 FAN button
Controls the fan speed.
(AUTO) (HIGH) (MED) (LOW) (QUIET)
• When AUTO is selected, the fan speed is automatically adjusted according to the operation mode.
9 SWING button
Starts or stops automatic swing of the vertical airfl ow direction louver.
• The Swing operation range will differ by mode as follows:
COOL, DRY, or FAN
1
2
3
4
5
6
7
Notes:
• SWING operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped.
• In FAN mode, swing operation range of 1  3 or 4  7 is decided according to the airfl ow direction previously set before starting the swing operation.
mode
12
3
10 SET button
Adjusts the vertical airfl ow direction.
11
WEEKLY timer button
Activates the WEEKLY timer for a maximum of 4 on or off programs per day, each day of the week.
12 SLEEP timer button
Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control.
13 ON/OFF timer button
Activates the ON/OFF timer.
HEAT or FAN mode
4
4
5
See page 3
See page 6
See page 6
See page 6
76
14 NEXT button
Used for adjusting the timer setting.
15 BACK button
Used for adjusting the timer setting.
16 RESET button
When you press the RESET button, press it gently by using the tip of a ballpoint pen or other small object in correct direction as shown in this fi gure.
20 SELECT button
Used for adjusting the clock or timer.
21
OUTDOOR UNIT LOW NOISE button
Starts or stops OUTDOOR UNIT LOW NOISE operation that lowers noise generated from the outdoor unit by cutting down the rotation number of the compressor, and suppressing the fan speed. Once the operation is set, the setting is preserved until you press this button again to stop the operation, even if the indoor unit operation is stopped.
OUTDOOR UNIT LOW NOISE mode.
Notes:
• This operation cannot be performed simultaneously with FAN, DRY
22
Starts or stops ECONOMY operation that saves more electricity than other operation modes by changing the set temperature to a moderate setting. By pressing the ECONOMY button, the ECONOMY indicator on the indoor unit turns on.
• In COOL or DRY mode, the room temperature will be adjusted a few
• In HEAT mode, the room temperature will be adjusted a few
Notes:
• In COOL, HEAT, or DRY mode, the maximum output of this
• This operation cannot be performed during temperature monitoring
23
Activates or deactivates the energy saving program. * The Energy Saving program is ON at the time of purchase.
: The setting must be done while the setting screen is displayed for
: The button is controllable only when the air conditioner is on.
on the remote controller display shows that the unit is in
and POWERFUL operation modes.
ECONOMY button
degrees higher than the set temperature.
degrees lower than the set temperature.
operation is approximately 70 % of usual air conditioning operation.
by AUTO mode.
SENSOR button (ENERGY SAVING PROGRAM)
each function.
See page 8
RESET
17 CLOCK ADJUST button
Used for adjusting the clock.
See page 2
18 SEND button
Used for sending the timer/clock setting.
19 TIMER SETTING button
Used to enter the timer setting mode.
9319356082_01_OM_EN.indd 59319356082_01_OM_EN.indd 5 7/1/2013 11:02:48 AM7/1/2013 11:02:48 AM
See page 6
OPERATING MANUAL
En-5
Timer Operation
Note for timer settings:
Any interruption of the power supply, such as a blackout or cutting off of a circuit breaker, makes the set internal clock incorrect. In such a case, the TIMER indicator on the indoor unit blinks, and you need to readjust the setting.
ON timer or OFF timer
You can set the ON timer or OFF timer with the following steps.
Press the TIMER SETTING button to start the setting.
1
The WEEKLY indicator will be fl ashing on the remote controller.
Press the SELECT button to choose the desired mode. The mode
2
will change as follows:
WEEKLY
Press the NEXT button. Continue to setting for each mode.
3
ON/OFF (ON)
ON/OFF (OFF)
ON/OFF
(ON
OFF)
SLEEP (OFF)
WEEKLY timer
ON and OFF timer can be combined, and up to 4 reservations (program
) per day and 28 reservations per week.
Before setting the program, please set the week and time of the air conditioner fi rst. If the week and time are not set, the weekly timer will not operate correctly at the set time. Please refer to "remote controller preparation" (page 2).
Example of WEEKLY timer 1
* To cancel timer setting during the setting process, press the
TIMER SETTING button again.
Adjust the time by pressing the SELECT button while the clock
4
indicator is blinking. Each time you press the button, the time will
Monday to
Friday
change by +5/-5 minutes. Pressing down will change the time by +10/-10 minutes.
Press the SEND button.
5
Saturday
To redo the timer setting, perform step 1 to 5 again. To cancel the ON/OFF timer, press the ON/OFF button while the ON/ OFF indicator is on. (Erases the indicator)
Sunday
Program timer (combined use of the ON timer and the OFF timer)
You can set an integrated ON–OFF or OFF–ON timer. Either of the timer whose confi gured starting time is closer to the current time works fi rst, and the order of timer operation is displayed as follows:
Timer Indicator on remote controller display
ON–OFF timer
OFF–ON timer
To set the program timer, conduct the same steps 1~5 for the ON/ OFF timer. (Select ONOFF in Step 2)
Notes:
• If you change the setting value for the timer after the program timer is set, the counting down of the timer will be reset at that moment.
• Time setting for each combination should be within a span of 24 hours
SLEEP timer
To set the SLEEP timer, fi rst follow steps 1~3 for the ON/OFF timer.
Adjust the time by pressing the SELECT button while the clock
4
indicator is blinking. Each time you press the button, the time changes as follows:
0H 30M
(30 min.)
Press the SEND button.
5
1H 00M
2H 00M
3H 00M
5H 00M
7H 00M
To cancel the SLEEP timer, press the SLEEP button while the SLEEP indicator is on. (Erases the indicator)
To help you to fall asleep comfortably and prevent excessive warming or cooling in sleep, the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows. The air conditioner completely turns off after the set time has elapsed.
In HEAT mode
1 °C 2 °C 3 °C 4 °C
In COOL or DRY mode
9H 00M
hours
Example of WEEKLY timer 2
You can specify a given temperature in the ON setting in WEEKLY timer.
Program
7:00 ON 22°C
* You can set the temperature for AUTO, COOL, and DRY modes within the range of 18-30°C, for Heat mode the range is 10 or 16-30°C. Even if you set to 10, 16, or 17°C, if you run the product on AUTO, COOL, or DRY, it will run at 18°C.
.
Notes:
• Operations modes other than the temperature setting will be the same at the last time operation was stopped, so Cooling Heating Cooling Heating type of operations cannot be automatically set.
• If you set the ON timer and OFF timer on the same time, the air conditioner will run the ON timer. If two ON timer are set at the same time, the air conditioner will run in the order of the program number.
• If there is a power interruption, such as due to a power outage during the WEEKLY timer setting or a circuit breaker cutting out, the internal timer of the air conditioner will be incorrect. (See page 9 "Auto-restart".) In such a case, the main timer lamp will notify you of this by fl ashing, so carry out matching of the time and date. (See page 2 "remote controller preparation".)
• You cannot use the WEEKLY timer together with the other timers. If you want to run the product on WEEKLY timer after using the ON/ OFF Timer, Program Timer, or SLEEP Timer while the WEEKLY timer is running, you need to activate the WEEKLY timer again.
Program
7:00 ON 24°C
Wake up
Program
ON ON ON ON
9:00 OFF
Program
9:00 OFF
Leave for work
Program
11:00 OFF
Program
9:00 ON 24°C
No timer settings
Program
17:00 ON 26°C
Program
17:00 ON 26°C
Come back home
Program
17:00 OFF
Program
23:00 ON 22°C
Program
23:00 OFF
Go to sleep
Program
23:00 OFF
30 min.
1 hour
1.5 hour
Set temperature
Set time
1 hour
Set time
1 °C
2 °C
(continued)
En-6
9319356082_01_OM_EN.indd 69319356082_01_OM_EN.indd 6 7/1/2013 11:02:49 AM7/1/2013 11:02:49 AM
OPERATING MANUAL
Timer Operation (continued)
To set the WEEKLY timer, fi rst follow steps 1~3 on page 6 for the ON/ OFF timer.
Select the program number and the day using the SELECT
4
button.
AIR CONDITIONER Wall Mounted Type
Program 1Week
Program
1Week
Program
Program
Monday
Monday
Tuesday Program Sunday
Program
Saturday Program Sunday
Program
Press the NEXT button, when the program number and day you
want to set are fl ashing.
Using the SELECT button select the operation mode(ON timer,
5
OFF timer, or without a timer).
To operate without a timer
1. Press the NEXT button to go back to step4 and confi gure the next setting.
2. Press the SEND button to fi nish
Press the NEXT button.
Press the SELECT button to set the desired ON time or OFF
6
time.
If you selected OFF in step 5
1. Press the NEXT button to go back to step 4 and confi gure the next setting.
2. Press the SEND button.
Press the NEXT button.
Press the SELECT button to set the temperature.
7
If you want to move on to the next setting, press the NEXT button, return to step 4 and confi gure the next setting.
To complete the setting, press the SEND button.
8
If you want to cancel the setting midway, please press the TIMER SETTING button instead of pressing the SEND button.
Notes:
When canceling the WEEKLY timer, select No Timer Operation in Step 5 in the WEEKLY timer setting.
If you want to go back to the previous step when confi guring settings, press the BACK button to return to the previous step.
Press the SEND button, when you are close to the main unit. If you do so when far from the main unit, the signal may not get properly sent, and the settings may not get properly confi gured.
To check the schedule, repeat steps 1 to 3 to enter the WEEKLY timer mode, then use the SELECT button to browse through the WEEKLY timer settings in the order shown in step 4.
To cancel the WEEKLY timer, press the WEEKLY button while the WEEKLY indicator is on. (Erases the indicator)
OPERATING MANUAL
9319356082_01_OM_EN.indd 79319356082_01_OM_EN.indd 7 7/1/2013 11:02:51 AM7/1/2013 11:02:51 AM
En-7
Human Sensor (Energy Saving)
To prevent waste of electricity, this function controls the temperature setting when no one is occupying the room. Energy Saving program is on at the time of purchase.
To activate the Energy Saving program, press the SENSOR
1
button.
indicator will be fl ashing on the remote controller
display.
To deactivate the Energy Saving program, press the SENSOR
2
button again.
will no longer be shown on the remote controller
display.
About the ENERGY SAVING Operation
If no one enters the room for approximately 20 minutes, the set temperature will be automatically controlled. (When someone comes back into the room, the human sensor will detect this, and automatically revert to the original settings.)
Operation
mode
COOL/DRY
HEAT
AUTO
(if there is no one in the room for a while)
The set temperature will be increased by a maximum of approximately 2˚C.
The set temperature will be decreased by a maximum of approximately 4˚C.
This runs the ENERGY SAVING function automatically for the selected mode (Cooling/ Heating/ Drying).
When using together with the SLEEP timer (page 6), the SLEEP timer will be prioritized.
During 10°C HEAT operation, if there is no one in the room the set temperature will not be changed.
Operating details
Application range is follows. Vertical angle 90° (Side view) Horizontal angle 100° (Top view)
7 m
7 m
ENERGY SAVING function may not work when the room temperature is very different from the temperature defi ned in temperature setting, such as when immediately after starting the operation.
90°
50° 50°
About the HUMAN SENSOR
Details about detection with the human sensor
●
The human sensor detects whether there are people in the room
by looking for movement by people in the room.
Notice
Since the human sensor detects infrared light given out by
●
people, there may be cases where this detection is incorrect.
Situations in which the sensor will detect no people in the room, even when there is someone there
●
When the temperature is high and the difference with be-
tween people’s body temperature is small. (Such as during the summer when the temperature is 30˚C or higher)
●
When there is someone in the room, but they do not move
for a long period of time.
●
When someone is hidden behind a sofa, other furniture,
glass, or in similar situations.
●
When someone is wearing extremely thick clothing and has
their back facing the sensor.
Situations in which the sensor will incorrectly detect people in the room, even when there is no one there
●
When there is a dog or a cat moving around in the room.
●
When the wind is making curtains or plants move.
●
When there are heating units, humidifi ers, or electric appli-
ances such as oscillating electric fans operating.
Demand Response and Indoor Unit Operation
This product is designed to be compatible with Air Conditioning Demand Response program. To utilize the function, you need a separate arrangement with your electricity supplier. Please check availability in the place of use. When your electricity supplier activates one of the following 3 Demand Response (DR) modes, the air conditioner switches over to the appropriate operation, and the OPERATION indicator (green) on the indoor unit blinks to inform you the unit has entered the DR mode.
OPERATION indicator
(indoor unit)
Blinking pattern and the intervals are as follows :
AUTO/COOL/HEAT/DRY/FAN operations ON (4 seconds) OFF (0.5 seconds)
OFF (0.5 seconds) ON (0.5 seconds)
10˚C HEAT operation
OFF (4 seconds) ON (0.5 seconds)
ON (0.5 seconds) OFF (0.5 seconds)
The indicator will keep blinking until the unit fi nishes the function.
DR mode Description of operation in this mode
DR mode 1 Compressor off.
DR mode 2
DR mode 3
When the unit enters the DR mode, it performs moderate operation so the cooling or heating effect may be reduced. You cannot override this function by changing the temperature setting using the remote controller or other actions unless the unit fi nishes the function.
Note: Stopping the operation of the air conditioner by using the remote
controller or by OFF timer are valid in DR mode. If the timer operation is interfered by an interruption of power supply such as a blackout and the power supply is resumed, no indication of the DR mode is performed. During the DR mode, no indication of "fi lter sign" is performed. Powerful operation is performed within the operable range of the DR mode.
When the unit fi nishes the function, it will perform the operation that was previously performed before entering the DR mode.
If you have operational issues, contact your electricity supplier fi rst to check whether they are activating any of the DR mode described above. If the air conditioner is under demand controlling, consult the issues with your electricity supplier. If they are not demand controlling the air conditioner, refer to your warranty card for the contact details of Fujitsu General (AUST.) PTY LIMITED or visit our website : www.fujitsugeneral.com.au
The air conditioner continues to cool or heat during the Demand Response event, but the electrical energy consumed by the air conditioner in a half hour period is not more than 50% of the total electrical energy that would be consumed if operating at the rated capacity in a half hour period.
The air conditioner continues to cool or heat during the Demand Response event, but the electrical energy consumed by the air conditioner in a half hour period is not more than 75% of the total electrical energy that would be consumed if operating at the rated capacity in a half hour period.
En-8
9319356082_01_OM_EN.indd 89319356082_01_OM_EN.indd 8 7/1/2013 11:02:52 AM7/1/2013 11:02:52 AM
OPERATING MANUAL
General Informations on Operation
AIR CONDITIONER Wall Mounted Type
Automatic defrosting operation
When outdoor temperature is very low with high humidity, frost may form on the outdoor unit during the heating operation, and it could reduce the operating performance of the product. For frost protection, a microcomputer-controlled automatic defrost function is equipped in this air conditioner. If frost forms, the air conditioner will temporarily stop, and defrost circuit will operate briefl y (maximum of 15 minutes.) OPERATION indicator on the indoor unit blinks during this operation. If frost forms on the outdoor unit after the heating operation, the outdoor unit will stop automatically after it operates for a few minutes. Then the automatic defrosting operation starts.
Auto-restart function
In event of power interruption such as a blackout, the air conditioner stops once. But it restarts automatically and performs previous operation when the power supply is resumed.
If any power interruption occurs after the timer is set, counting down of the timer will be reset. After the power supply is resumed, the TIMER indicator on the indoor unit blinks to notify you that there has been a timer fault. In such a case, reset the timer for your opportune time.
Heating performance
• This air conditioner operates on the heat-pump principle, absorbing heat from air outdoors and transferring that heat to the indoor unit. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that the heating performance is insuffi cient, we recommend you to use this air conditioner in conjunction with other kinds of heating appliance.
Malfunctions caused by other electrical devices:
Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner. If you encounter such a malfunction, turn off the circuit breaker once. Then turn it on again, and resume operation by using the remote controller.
Temperature and Humidity Range
Permissible ranges of temperature and humidity are as follows:
COOL/DRY Indoor temperature About 18 °C to 32 °C
Indoor humidity Below approximately 80%.
If the air conditioner is used continuously for many hours, water may condense on the surface and drip.
HEAT Indoor temperature About 16 °C to 30 °C
If the unit is used under higher temperature conditions than those noted here, the automatic protection circuit may operate, interrupting the operation. If the unit is used under lower temperature conditions than those noted here, the heat exchanger may freeze, causing water leakage or other mal­function.
Do not use the air conditioner for any purpose other than room cooling/dry, room heating or fan.
OPERATING MANUAL
9319356082_01_OM_EN.indd 99319356082_01_OM_EN.indd 9 7/1/2013 11:02:52 AM7/1/2013 11:02:52 AM
En-9
Care and Cleaning
CAUTION
• Before cleaning the indoor unit, be sure to turn it off and all the power supply has been disconnected.
• Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an effect on the proper working or performance of the air conditioner.
• Do not touch the aluminum fi ns of heat exchanger built-in the indoor unit to avoid personal injury when you maintain the unit.
• Do not expose the indoor unit to liquid insecticides or hair sprays.
• Do not stand on slippery, uneven or unstable surfaces when you maintain the unit.
Daily care
When cleaning the indoor unit body, mind the following:
• Do not use water hotter than 40 °C.
• Do not use scouring cleanser, volatile solvents such as benzene or thinner.
• Wipe the unit gently by using soft cloth.
Open the Intake Grille
1. Pull the tab on both sides of the intake grille to­wards you.
Ta b Ta b
Do not open just the Open panel.
GOOD PROHIBITED
Intake grille tab Intake grille tab
Open Panel
2. Fix the intake grille with the grille stay.
Grille stay
Click
3. Replace the air fi lters.
Align the sides of the air fi lter with the panel, and push in fully,
making sure the 2 lower tabs are returned properly to their holes in the panel.
Air fi lter tabs (2 places)
Close the Intake Grille
1. Release the grille stay.
Grille stay
Click
2. Close the intake grille.
Press point A and point C lightly until they click, then press lightly
at point B.
Click
ABC
Click
Cleaning the Air Filters
1. Remove the air fi lters.
Lift up the air fi lter handle, disconnect the 2 lower tabs, and pull out.
Air fi lter handles
Air fi lter tabs (2 places)
2. Remove the dust with a vacuum cleaner or by washing.
Dust can be cleaned from the air fi lter either with a vacuum cleaner,
or by washing the fi lter in a solution of neutral detergent and warm water. If you wash the fi lter, be sure to allow it to dry thoroughly in a shaded place before reinstalling.
If dust is allowed to accumulate on the air filter, airflow will be
reduced, lowering operating effi ciency and increasing noise.
During periods of normal use, the Air Filters should be cleaned
every 2 weeks.
For point C, please slightly press on the inner side.
If the intake grille is not completely closed, the air-conditioner will
not operate and the lamp will fl ash as shown below.
Indicator Lamp
OPERATION
ECONOMYTIMER
: Flashing
Operation Lamp fl ashes 5 times, then the Timer lamp 8 times repeatedly, and the Economy lamp will continue fl ashing.
When the grille is closed fi rmly, fl ashing of the lamps stop and the indoor unit starts operation.
When closing the intake grille, the Open panel may open. In this case please turn off the power then turn it on again for the Open panel to return to its normal closed position.
En-10
9319356082_01_OM_EN.indd 109319356082_01_OM_EN.indd 10 7/1/2013 11:02:52 AM7/1/2013 11:02:52 AM
OPERATING MANUAL
Care and Cleaning
AIR CONDITIONER Wall Mounted Type
Replacing the air cleaning fi lter
1. Open the intake grille and remove the air fi lters.
Please refer to the page 10.
2. Remove the dirty air cleaning fi lters attached to the frames of the front panel.
Air cleaning fi lter frame
Air cleaning fi lters
3. Attach the new or maintained air cleaning fi lters to the frame of the front panel.
Air cleaning fi lter frame
Tabs (7 places)
Tabs (7 places)
Air cleaning fi lter
The new air cleaning fi lters can be attached to the right frame or
the left frame.
Replace fi lters with the following components (purchased sepa-
rately).
APPLE-CATECHIN FILTER: UTR-FA16
ION DEODORIZATION FILTER: UTR-FA16-2
4. Install the air fi lters and close the intake grille.
Please refer to page 10.
Following 2 types of air cleaning fi lters are used in this product. When you replace them, purchase dedicated air cleaning fi lters for this product.
Apple-catechin fi lter: UTR-FA16
(1 sheet)
The Apple-catechin fi lter uses static electricity to clean fi ne particles and dust in the air such as tobacco smoke and plant pollen that are too small to see.
• This fi lter is disposable. Do not wash or reuse it.
• Once you open the package, use it as soon as possible. The
cleaning effect is reduced if the fi lter is left with the package opened.
• Replace the fi lter once every 3 months under normal use.
• By setting the fan speed high, the air cleaning effect increases.
Ion deodorization fi lter: UTR-FA16-2
(Light blue, 1 sheet)
The fi lter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fi ne-particle ceramic.
• To maintain the deodorizing effect, clean the fi lter once every 3
months as follows:
1. Remove the lter.
2. Flush the lter with high-pressure hot water until the surface of
the fi lter is covered with water.
3. Wash the fi lter gently with diluent nuetral detergent. Do not wash
it by wringing or rubbing to prevent reducing the deodorizing effect by damage.
4. Rinse the lter well with water ow.
5. Dry the lter throughly in a shaded place.
6. Reinstall the lter to the indoor unit.
• Replace the fi lter once every 3 years under normal use.
After extended non-use of the unit
If you have shut down the indoor unit for 1 month or more, perform the FAN operation for half a day to dry the internal parts throughly before you perform normal operation.
Additional inspection
After long period of use, accumulated dust inside the indoor unit may reduce the product performance even if you have maintained the unit with instructed daily care or cleaning procedures written in this manual.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.
OPERATING MANUAL
9319356082_01_OM_EN.indd 119319356082_01_OM_EN.indd 11 7/1/2013 11:02:53 AM7/1/2013 11:02:53 AM
En-11
Troubleshooting
WARNING
In following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel. As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off.
• Unit smells of something burning or emits smoke
• Water leaks from the unit
Following symptoms do not indicate product malfunction, but they are normal functions or characteristics of this product.
Symptom Cause See page
Operation is delayed after restart.
Noise is heard. • During operation or immediately after stopping the air conditioner, refrigerant fl owing sound may be
Smell coming from the unit. Various smells generated from interior textile, furniture, or cigarette smoke absorbed into the air
Mist or steam is emitted from the unit.
Airfl ow is weak or stops. • Immediately after the heating operation is started, the fan speed stays very low temporarily to warm
Outdoor unit emits water. During heating operation, the outdoor unit may emit water generated by the automatic defrosting
To prevent blowout of the fuse, the compressor will not operate while the protection circuit is working for about 3 minutes after sudden OFFON operation of the power supply.
heard. Also it may be particularly noticeable for 2–3 minutes after starting operation.
• During the operation, a slight squeaking sound produced by the minute expansion and contraction of the front panel caused by temperature change may be heard.
During heating operation, a sizzling sound produced by the automatic defrosting operation may be heard.
conditioner may be emitted.
In COOL or DRY mode, a thin mist generated by condensation formed with sudden cooling process may be emitted.
During heating operation, the fan built-in the outdoor unit may stop and rising steam generated by the automatic defrosting operation may be seen.
up the internal parts of the unit.
• In HEAT mode, the outdoor unit stops and the indoor unit operates at very low fan speed if the room temperature rises above the set temperature.
In HEAT mode, the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is fl ashing.
In DRY mode, the indoor unit operates at low fan speed to adjust the room humidity, and may stop from time to time.
When the fan speed is set to “QUIET”, the fan rotates at very low speed and the airfl ow is reduced.
In COOL mode, the indoor unit fan may stop from time to time when the outdoor unit is stopped. 4
When monitoring operation is performed in AUTO mode, the fan rotates at very low speed.
operation.
9
9
9
9
Before you call for or request servicing, troubleshoot a problem by performing following checks:
Symptom Diagnostic See page
Does not operate at all.
Poor cooling or heating perfor­mance.
The unit operates differently from the remote controller setting.
Immediately stop operation and turn off the electrical breaker in following cases. Then consult authorized service personnel.
• The problem persists even if you perform these checks or diagnostics.
• The OPERATION indicator and TIMER indicator blink while the ECONOMY indicator is blinking fast.
Has the circuit breaker been turned off? Has there been a power outage? Has a fuse blown out or the circuit breaker been tripped?
Is the intake grille completely closed?
Is the timer operating?
Is the air lter dirty?
Is the intake grill or outlet port of indoor unit blocked?
Is the room temperature adjusted appropriately?
Is a window or door left opened? Is direct or strong sunlight shinning into the room in cooling operation? Are there other heating apparatus or computers operating, or too many people in the room in cool-
ing operation?
Is the fan speed set to “QUIET”?
When the fan speed setting is set to “QUIET”, noise reduction is prioritized and the air-conditioning performance may become lower. If the volume of provided airfl ow is not agreeable to your prefer- ence, set the fan speed to “LOW” or higher fan speed.
Has the OUTDOOR UNIT LOW NOISE mode been set?
Do you have an arrangement with your electric company for Demand Response?
Are the batteries used in the remote controller exhausted? Are the batteries used in the remote controller loaded properly?
10
6
10
4
5
5
8
2
En-12
9319356082_01_OM_EN.indd 129319356082_01_OM_EN.indd 12 7/1/2013 11:02:54 AM7/1/2013 11:02:54 AM
OPERATING MANUAL