Fujitsu AS*9LSACW, AS*12LSACW, AS*14LSBCW, AS*18LSBCW, AO*9LSAC Service Instructions Manual

...
SPLIT TYPE ROOM AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
AS*9LSACW AS*12LSACW
AS*9LSBCW AS*12LSBCW AS*14LSBCW AS*18LSBCW
AO*9LFBC AO*12LFBC AOY14LFBC AO*18LFBC
INVERTER
SERVICE
INSTRUCTION
R410A
CONTENTS
1. SPECIFICATION
AS*14/ 18LSBC, AO*14 / 18LFBC..................................................................................01-03
AS*9 / 12LSAC, AO*9 / 12LSAC.....................................................................................02-01
2. DIMENSIONS
AS*9 / 12LSBC, AO*9 / 12LFBC.....................................................................................01-02
AS*9 / 12LSAC, AO*9 / 12LSAC.....................................................................................01-01
AS*14 / 18LSBC, AO*14 / 18LFBC.................................................................................02-03
AS*9 / 12LSBC, AO*9 / 12LFBC.....................................................................................02-02
3. REFRIGERANT SYSTEM DIAGRAM
AS*9 / 12LSAC, AO*9 / 12LSAC.....................................................................................03-01
AS*14 / 18LSBC, AO*14 / 18LFBC.................................................................................03-03
AS*9 / 12LSBC, AO*9 / 12LFBC.....................................................................................03-02
4. CIRCUIT DIAGRAM
AS*9 / 12LSAC, AO*9 / 12LSAC.....................................................................................04-01
AS*14 / 18LSBC, AO*14 / 18LFBC.................................................................................04-03
AS*9 / 12LSBC, AO*9 / 12LFBC.....................................................................................04-02
5. DESCRIPTION OF EACH CONTROL OPERATION
1. COOLING OPERATION..............................................................................................05-01
3. DRY OPERATION......................................................................................................05-03
2. HEATING OPERATION..............................................................................................05-02
5. INDOOR FAN CONTROL...........................................................................................05-05
4. AUTO CHANGEOVER OPERATION.........................................................................05-04
7. LOUVER CONTROL...................................................................................................05-08
6. OUTDOOR FAN CONTROL.......................................................................................05-07
9. TIMER OPERATION CONTROL................................................................................05-10
8. COMPRESSOR CONTROL........................................................................................05-09
11. TEST OPERATION CONTROL..................................................................................05-12
10. ELECTRONIC EXPANSION VALVE CONTROL........................................................05-12
13. FOUR-WAY VALVE EXTENSION SELECT...............................................................05-12
12. PREVENT TO RESTART FOR 3 MINUTES ( 3 MINUTES ST ).................................05-12
15. MANUAL AUTO OPERATION ( Indoor unit body operation ).....................................05-13
14. AUTO RESTART.........................................................................................................05-12
17. COIL DRY OPEARTION CONTROL..........................................................................05-13
16. COMPRESSOR PREHEATING..................................................................................05-13
6. REFRIGERANT CAUTION -R410A-
18. DEFROST OPERATION CONTROL..........................................................................05-14
20. VARIOUS PROTECTIONS.........................................................................................05-17
19. OFF DEFROST OPERATION CONTROL..................................................................05-16
1. R410A TOOLS............................................................................................................06-01
3. PRECAUTION FOR SERVICING...............................................................................06-04
2. PRECAUTION FOR INSTALLATION.........................................................................06-02
5. DEFFERENCE FROM CONVENTIONAL MODEL(R22) AND PRECAUTIONS........06-08
4. NEW REFRIGERANT R410A.....................................................................................06-05
7. TROUBLE SHOOTING
1. WHEN THE UNIT DOES NOT OPERATE AT ALL....................................................07-01
3. TROUBLE SHOOTING METHOD
2. SELF DIAGNOSIS FUNCTION..................................................................................07-02
8. APPENDING DATA
1. JUMPER SETTING OF INDOOR UNIT AND OUTDOOR UNIT................................08-01
3. THERMISTOR RESISTANCE VALUES.....................................................................08-08
2. OUTDOOR UNIT PRESSURE VALUE AND TOTAL ELECTRIC
CURRENT CURVE...................................................................................................08-02
9. INSTALLATION MANUAL
4. SELF-DIAGNOSIS FUNCTION AND CHECKING POINTS.......................................07-03
5. SERIAL SIGNAL DIAGNOSIS....................................................................................07-08
6. IPM PROTECTION.....................................................................................................07-09
7. ACTIVE FILTER FAILURE.........................................................................................07-10
8. TROUBLE SHOOTING OF REFRIGERANT CYCLE.................................................07-11
1 . SPECIFICATIONS
R410A
WALL MOUNTED type
INVERTER
SPECIFICATIONS
TYPE
(COOL&HEAT INVERTER) (COOL&HEAT INVERTER)
INDOOR UNIT
AS*9LSACW AS*12LSACW
OUTDOOR UNIT AO*9LSAC AO*12LSAC
COOLING CAPACITY( ) : Range
(kW)
2.6 (0.5~3.6) 3.5 (0.9~4.2)
HEATING CAPACITY( ) : Range
(kW) 3.6 (0.5~6.0) 4.8 (0.9~6.6)
POWER SOURCE
(V) 230
FREQUENCY
(Hz)
50
RUNNING CURRENT
(A)
COOLING 3.0
3.6
5.8
1.33 (0.25~2.30)0.91 (0.25~1.96)
4.6
HEATING
INPUT WATTS
(kW)
COOLING
0.68 (0.25~1.38) 1.03 (0.25~1.61)
HEATING
EER
(kW/kW)
COOLING 3.82 3.40
3.96 3.61
1.8
HEATING
MOISTURE REMOVAL
1.3
AIR CIRCULATION-Hi
(m3/hr)
C 630 H665
C 630 H700
ELECTRICAL DATA
COMPRESSOR
Note : Always use a vacuum pump to purge the air.
Refrigerant for purging the air is not charged in the outdoor unit at the factory.
DIMENSIONS
TYPE Hermetic type,4 pole, 3 phase , DC brushles motor
DISCRIMINATION 80206680
REFRIGERANT R410A
(g)
(r.p.m.)
(r.p.m.)
950
1100
POWER SOURCE (V) 230
HI-SPEED
MED-SPEED
INDOOR UNIT
LO-SPEED
QUIET
C 1,350 H 1,420
C 1,150 H 1,200
C 950 H 1,000
C 740 H 900
C 1,400 H 1,470
C 1,200 H 1,290
C 1,000 H 1,110
C 820 H 980
OUTDOOR UNIT 830
INDOOR UNIT H x W x D (mm)
H x W x D (mm)
280 x 790 x 230
OUTDOOR UNIT 535 x 780 x 250
FAN MOTOR
(dB)
(dB)
HI-SPEED
MED-SPEED
INDOOR UNIT
LO-SPEED
QUIET
C 42 H 42
OUTDOOR UNIT
NOISE LEVEL
15 m
None
WEIGHTS
INDOOR UNIT
OUTDOOR UNIT
80206680
( /hr)
C 43 H 43
C 37 H 36 C 39 H38
C 31 H 30 C 32 H 33
C 23 H 26 C 26 H 29
C 47 H 49
Note : Noise was measured in accordance with JIS standards, Japan.
GROSS / NET (kg)
GROSS / NET (kg)
12 / 9
35 / 33 37 / 34
MAX PIPE LENGTH
ADDITIONAL REFRIGERANT
THICKNESSES OF ANNEALED COPPER PIPES
Nominal diameter
1/4
3/8
Outer diameter (mm)
6.35
9.52
R410A
0.80
0.80
[ref,] R22
0.80
0.80
Thickness (mm)
01-01
SPECIFICATIONS
INDOOR UNIT
H x W x D (mm)
H x W x D (mm)
275 x 790 x 215
OUTDOOR UNIT
540 x 790 x 290
DIMENSIONS
INDOOR UNIT
GROSS / NET (kg)
GROSS / NET (kg)
12 / 9
OUTDOOR UNIT
42 / 3839 / 35
WEIGHT
TYPE
COOL & HEAT INVERTER
INDOOR UNIT
AS*12LSBCW
OUTDOOR UNIT
AO*12LFBC
AS*9LSBCW
AO*9LFBC
COOLING CAPACITY
(kW) 3.50
HEATING CAPACITY
(kW)
4.80
POWER SOURCE (V) 230
FREQUENCY (Hz)
50
RUNNING CURRENT
COOLING 4.3
(A)
HEATING
5.6
INPUT WATTS
(kW)
COOLING 0.92
HEATING
1.23
E.E.R.
COOLING
3.80
COP HEATING
3.90
MOISTURE REMOVAL
1.8
AIR CIRCULATION-Hi (m /hr)
3
C 635 H 670C 595 H 645
2.60
3.60
3.0
3.8
0.62
0.82
4.19
4.39
1.3
FAN MOTOR
TYPE
Hermetic type, 4 pole, 3 phase, DC inverter motor, Rotary
DISCRIMINATION DA 89 X 1F - 20F
REFRIGERANT R410A (g) 1,050950
POWER SOURCE (V) 230
HI-SPEED (r.p.m.) C 1,300 H 1,390
INDOOR UNIT
MED-SPEED (r.p.m.) C 1,120 H 1,200
LO-SPEED (r.p.m.) C 950 H 1,000
QUIET (r.p.m.) C 700 H 760
C 1,370 H 1,440
C 1,150 H 1,200
C 950 H 1,000
C 700 H 760
OUTDOOR UNIT (r.p.m.) C 830 H 830C 840 H 840
ELECTRICAL DATA
COMPRESSOR
( /hr)
INDOOR UNIT
(dB) C 43 H 43
OUTDOOR UNIT
(dB) C 47 H 49
C 42 H 42
C 47 H 48
NOISE LEVEL
REFRIGERANT (R410A)
Pipe Length
15 m 950 g 1,050 g
FULL CHARGE AMOUNT
20 m 1,050 g 1,150 g
ADDITIONAL REFRIGERANT
20 g / m
(kW/kW)
(kW/kW)
THICKNESSES OF ANNEALED COPPER PIPES
Nominal diameter
1/4
3/8
Outer diameter (mm)
6.35
9.52
R410A
0.80
0.80
[ref,] R22
0.80
0.80
Thickness (mm)
01-02
SPECIFICATIONS
INDOOR UNIT
H x W x D (mm)
H x W x D (mm)
275 x 790 x 215
OUTDOOR UNIT
578 x 790 x 300
DIMENSIONS
INDOOR UNIT
GROSS / NET
(kg)
GROSS / NET (kg)
12 / 9
OUTDOOR UNIT
40 / 38
WEIGHT
TYPE
COOL & HEAT INVERTER
INDOOR UNIT
AS*18LSBCW
OUTDOOR UNIT
AO*18LFBC
AS*14LSBCW
AO*14LFBC
COOLING CAPACITY
(kW) 5.20
HEATING CAPACITY
(kW)
6.25
POWER SOURCE (V) 230
FREQUENCY (Hz)
50
RUNNING CURRENT
COOLING 7.6
(A)
HEATING
7.6
INPUT WATTS
(kW)
COOLING 1.72
HEATING
1.73
E.E.R.
COOLING
3.02
COP HEATING
3.61
MOISTURE REMOVAL
2.8
AIR CIRCULATION-Hi (m /hr)
3
C 700 H700C 700 H700
4.20
5.60
4.9
6.4
1.11
1.45
3.78
3.86
2.1
FAN MOTOR
TYPE
Hermetic type, 4 pole, 3 phase, DC inverter motor, Rotary
DISCRIMINATION DA / 30A / F-25F
REFRIGERANT R410A (g) 1,150
POWER SOURCE (V) 230
HI-SPEED (r.p.m.) C 1,480 H 1,480
INDOOR UNIT
MED-SPEED (r.p.m.) C 1,260 H 1,300
LO-SPEED (r.p.m.) C 1,040 H 1,110
QUIET (r.p.m.) C 850 H 950
OUTDOOR UNIT (r.p.m.) C 860 H 820C 820 H 750
ELECTRICAL DATA
COMPRESSOR
( /hr)
INDOOR UNIT
(dB) C 45 H 43
OUTDOOR UNIT
(dB) C 49 H 49
C 44 H 43
C 48 H 48
NOISE LEVEL
REFRIGERANT (R410A)
PIPE LENGTH
15 m 1,150 g
FULL CHARGE AMOUNT
20 m 1,250 g
ADDITIONAL REFRIGERANT
20 g / m
(kW/kW)
(kW/kW)
THICKNESSES OF ANNEALED COPPER PIPES
Nominal diameter
1/4
1/2
Outer diameter (mm)
6.35
12.7
R410A
0.80
0.80
[ref,] R22
0.80
0.80
Thickness (mm)
01-03
2 . DIMENSIONS
R410A
WALL MOUNTED type
INVERTER
DIMENSIONS
Models : AS*9LSACW / AO*9LSAC
AS*12LSACW / AO*12LSAC
540 120
272
302
780 55
250
535
10
280
790 230
02-01
DIMENSIONS
AS*12LSBCW / AO*12LFBC
Models : AS*9LSBCW / AO*9LFBC
(unit : mm)
275
2,000
215
790
02-02
DIMENSIONS
AS*18LSBCW / AO*18LFBC
Models : AS*14LSBCW / AO*14LFBC
(unit : mm)
275
2,000
215
790
347
578
48
10
320
508
540
20
300
125
60
790
02-03
3 . REFRIGERANT SYSTEM DIAGRAM
R410A
WALL MOUNTED type
INVERTER
REFRIGERANT SYSTEM DIAGRAM
Models : AS*9LSACW / AO*9LSACW AS*12LSACW / AO*12LSACW
(2 pass)
(2 pass)
Indoor heat exchanger
Outdoor heat exchanger
Capillary tube
Pulse motor valve
2way-valve3way-valve
Muffler
Compressor
Accumulator
4way-valve
Strainer Dryer
03-01
REFRIGERANT SYSTEM DIAGRAM
2-Way
valve
Strainer
Strainer
3-Way
valve
Muffler
Muffler
4-Way valve
Expansion valve
Heat exchanger
( INDOOR )
Heat exchanger ( OUTDOOR )
AOY9LFBC
(2Pass)
AOY12LFBC
(4Pass)
Compressor
Cooling Heating
AS*12LSBCW / AO*12LFBC
Models : AS*9LSBCW / AO*9LFBC
03-02
REFRIGERANT SYSTEM DIAGRAM
2-Way
valve
Strainer
Strainer
Sub-heat
exchanger
( INDOOR )
3-Way
valve
Muffler
4-Way valve
Expansion valve
Heat exchanger
( INDOOR )
Heat exchanger ( OUTDOOR )
Sub-accumulator
Compressor
Cooling Heating
AS*18LSBCW / AO*18LFBC
Models : AS*14LSBCW / AO*14LFBC
03-03
4 . CIRCUIT DIAGRAM
R410A
WALL MOUNTED type
INVERTER
CIRCUIT DIAGRAM
INDOOR UNIT
OUTDOOR UNIT
Models : AS*9LSACW / AO*9LSAC
AS*12LSACW / AO*12LSAC
Controller PCB
Thermistor (pipe)
Thermistor (discharge pipe)
Thermistor (outdoor temp.)
04-01
CIRCUIT DIAGRAM
INDOOR UNIT
OUTDOOR UNIT
AS*12LSBCW / AO*12LFBC
Models : AS*9LSBCW / AO*9LFBC
Fan Motor
Stepping Motor
Thermistor (room temp.)
Terminal
Terminal
Fuse 250V20A
Reactor Reactor
Fan Motor
Expansion Valve
4-Way Valve Assy
PCB (MAIN)
Power Relay
Compressor
Thermistor (pipe temp.)
Test
Thermistor (pipe)
Thermistor (Discharge Pipe)
Thermistor (outdoor temp.)
Display Board
Controller PCB
Power
102 C
Thermal Fuse
1 2 3 4 5 6
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
4 5
1 2 3 4 5
1 2 3
1 2 3
1 2 3
4
1 2 3 4
1 2 3 4
5
6
1
2
3
4
5
1
2
3
4
5
1
2
1
2
1
2
3
4
5
1
2
3
4
5
6
7
1
2
3
4
5
6
1
2
3
4
5
6
1
2
2
1
2
1
3
4
5
6
7
8
9
10
11
1
2
3
4
5
6
7
8
9
10
11
04-02
CIRCUIT DIAGRAM
INDOOR UNIT
OUTDOOR UNIT
AS*18LSBCW / AO*18LFBC
Models : AS*14LSBCW / AO*14LFBC
DISPLAY BOARD
CONTROL BOARD
04-03
5 . DESCRIPTION OF EACH CONTROL OPERATION
R410A
WALL MOUNTED type
INVERTER
1. COOLING OPERATION
1-1 COOLING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive difference or variation between a set temperature and present room temperature, and controls the operation frequency of the compressor. * If the room temperature is 2 C higher than a set temperature, the compressor operation frequency will attain to maximum performance.
* If the room temperature is 2.5 C lower than a set temperature, the compressor will be stopped.
* When the room temperature is between +2 C to -2.5 C of the setting temperature, the compressor frequency is controlled within the range shown in Table1. However, the maximum frequency is limited in the range shown in Figure 1 based on the fan speed mode and the outdoor temperature.
minimum
frequency
maximum frequency
maximum
frequency AS*9LSACW 18Hz 60Hz 80Hz AS*12LSACW 18Hz 80Hz 96Hz AS*9LSBCW 18Hz 61Hz 80Hz AS*12LSBCW 18Hz 80Hz 96Hz AS*14LSBCW 18Hz 70Hz 90Hz AS*18LSBCW 18Hz 70Hz 90Hz
Outside air Outside air temperature temperature
36 C
A zone
34 C
32 C
B zone
30 C
21 C
C zone
19 C
D zone
Hi Me Lo Quiet
A zone 80Hz 51Hz 45Hz 33Hz B zone 80Hz 51Hz 45Hz 33Hz C zone 80Hz 51Hz 45Hz 33Hz
9LSACW
D zone 51Hz 39Hz 33Hz 27Hz A zone 96Hz 60Hz 51Hz 33Hz B zone 96Hz 60Hz 51Hz 33Hz C zone 80Hz 60Hz 51Hz 33Hz
12LSACW
D zone 51Hz 42Hz 36Hz 27Hz A zone 80Hz 61Hz 51Hz 33Hz B zone 80Hz 61Hz 51Hz 33Hz C zone 80Hz 61Hz 51Hz 33Hz
9LSBCW
D zone 51Hz 42Hz 36Hz 22Hz A zone 96Hz 61Hz 51Hz 33Hz B zone 96Hz 61Hz 51Hz 33Hz C zone 96Hz 61Hz 51Hz 33Hz
12LSBCW
D zone 51Hz 42Hz 36Hz 22Hz A zone 90Hz 45Hz 42Hz 30Hz B zone 90Hz 45Hz 42Hz 30Hz C zone 90Hz 45Hz 42Hz 30Hz
14LSBCW
D zone 49Hz 38Hz 34Hz 24Hz A zone 90Hz 45Hz 42Hz 30Hz B zone 90Hz 45Hz 42Hz 30Hz C zone 90Hz 45Hz 42Hz 30Hz
18LSBCW
D zone 49Hz 38Hz 34Hz 24Hz
( Table 1 : Compressor Frequency Range )
( Fig. 1 : Limit of Maximum Frequency based on Outdoor Temperature )
When the compressor operates for 30 minutes continuously at over the maximum frequency , the maximum frequency is changed from Maximum Frequency to Maximum Frequency . The room temperature is controlled 1 C lower than the setting temperature for 40 minutes after starting the operation. After 40 minutes, it is controlled based on the normal setting temperature.
05-01
2. HEATING OPERATION
2-1 HEATING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive difference or variation between a set temperature and present room temperature, and controls the operation frequency of the compressor. * If the room temperature is lower by 3 C than a set temperature, the compressor operation frequency will attain to maximum performance.
* If the room temperature is higher 2.5 C than a set temperatire, the compressor will be stopped.
minimum
frequency
maximum
frequency AS*9LSACW 18Hz 130Hz AS*12LSACW 18Hz 130Hz AS*9LSBCW 18Hz 130Hz AS*12LSBCW 18Hz 130Hz AS*14LSBCW 18Hz 119Hz AS*18LSBCW 18Hz 119Hz
Outside air Outside air temperature temperature
19 C
C zone
17 C
14 C
B zone
12 C
A zone
Hi Me Lo Quiet
A zone 130Hz 92Hz 80Hz 68Hz B zone 130Hz 80Hz 60Hz 54Hz
9LSACW
C zone 96Hz 68Hz 54Hz 51Hz A zone 130Hz 96Hz 80Hz 68Hz B zone 130Hz 96Hz 64Hz 57Hz
12LSACW
C zone 96Hz 96Hz 64Hz 54Hz A zone 130Hz 96Hz 80Hz 68Hz B zone 130Hz 96Hz 80Hz 54Hz
9LSBCW
C zone 130Hz 96Hz 80Hz 45Hz A zone 130Hz 96Hz 80Hz 68Hz B zone 130Hz 96Hz 80Hz 54Hz
12LSBCW
C zone 130Hz 96Hz 80Hz 45Hz A zone 119Hz 90Hz 70Hz 58Hz B zone 119Hz 90Hz 70Hz 58Hz
14LSBCW
C zone 119Hz 90Hz 70Hz 58Hz A zone 119Hz 90Hz 70Hz 58Hz B zone 119Hz 90Hz 70Hz 58Hz
18LSBCW
C zone 119Hz 90Hz 70Hz 58Hz
* When the room temperature is between +2 C to -3 C of the setting temperature, the compressor frequency is controlled within the range shown in Table2. However, the maximum frequency is limited in the range shown in Figure 2 based on the fan speed mode and the outdoor temperature.
( Table 2 : Compressor Frequency Range )
( Fig.2 : Limit of Maximum Frequency based on Outdoor Temperature )
* The room temperature is controlled 2 C higher than the setting temperature for 60 minutes after starting the operation. After 60 minutes, it is controlled based on the normal setting temperature.
05-02
3. DRY OPERATION
3-1 INDOOR UNIT CONTROL
The compressor rotation frequency shall change according to the temperature, set temperature, and room temperature variation which the room temperature sensor of the indoor unit body has detected as shown in the Table 3. However, after the compressor is driven, the indoor unit shall run at operation frequency of 58Hz, for a minute.
Operating
frequency AS*9LSACW 33Hz AS*12LSACW 33Hz AS*9LSBCW 33Hz AS*12LSBCW 33Hz AS*14LSBCW 24Hz AS*18LSBCW 24Hz
room room temperatu re temperature
compressor ON
Ts+1.5 C
Ts+0.5 C
compressor OFF
Compressor
ON
OFF
Indoor fan
Dry air flow
S-Lo
OFF
10 30 60 180 60 180 60 10 30 (sec)
( Table 3 : Compressor frequency )
( Fig.3 : Compressor Control based on Room Temperature )
( Fig.4 : Indoor Fan Control )
05-03
4. AUTO CHANGEOVER OPERATION
When the air conditioner is set to the AUTO mode by remote cintrol, operation starts in the optimum mode from amoung the HEATING, COOLING, DRY and MONITORING modes. During operation, the optimum mode is automatically swiched in accordance with temperature changes. The temperature can be set between 18 C and 30 C in 1 C steps.
.When operation starts, only the indoor and outdoor fans are operated for 1 minute. After 1 minute,
the room temperature and outside air temperature are sensed and the operation mode is selected in accordance with the table below.
C zone
32 C
B zone
10 C
A zone
( Table.4 Operation mode selection table)
Outside air temperature (TO)
Room temperature(TB)
A zone B zone C zone
TB > TS+ 2 C
Monitoring
Cooling
(automatic dry)
Cooling
(automatic dry)
TS+2 C TB TS-2 C
Monitoring Monitoring Monitoring
TB TS-2 C Heating Heating Monitoring
.When COOING was selected at , the air conditioner operates as follow:
The same operation as COOLING OPERATION of item 1 above is performed. When the room temperature has remained at (set tempareure -1 C) for 8 minutes, operation is automatically switched to DRY and the same operation as DRY OPERATION of item 3 above is performed. If the room temperature reaches (set temperature+2 C during DRY operation, operation returns to COOLING operation.
.When HEATING was selected at , the same operation as HEATING OPERATION of item 2 above is performed.
When the compressor was stopped for 6 consecutive minutes by the temperature control function after the COOLING or HEATING operation mode was selected at above, operation is switched to MONITORING and the operation mode is selected again.
1
<
1
2
3
1
4
1
( Fig.5 : Outside air temperature zone selection )
05-04
5. INDOOR FAN CONTROL
(1).Fan speed
( Table 5 : Indoor Fan Speed )
AS*9LSACW
Operation mode Air flow mode Speed (rpm)
Hi 1420
Me+ 1370
Me 1200
Lo 1000
Quiet 900
Cool air
prevention
850
Heating
S-Lo 480
Hi 1350
Me 1150
Lo 950
Cooling Fan
Quiet 740
Dry 740
AS*9LSBCW
Operat ion mode Air flow mode Speed (rpm)
Hi 1390
Me+ 1350
Me 1200
Lo 1000
Quiet 760
Cool air
prevention
760
Heating
S-Lo 480
Hi 1300
Me 1120
Lo 950
Cooling Fan
Quiet 700
Dry 700
AS*14LSBCW
Operation mode Air flow mode Speed (rpm)
Hi 1480
Me+ 1420
Me 1300
Lo 1110
Quiet 950
Cool air
prevention
850
Heatin g
S-Lo 480
Hi 1480
Me 1260
Lo 1040
Cooling Fan
Quiet 850
Dry 850
(2).FAN OPERATION
The airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH, while the indoor fan only runs. When Fan mode is set at (Auto), it operates on (MED) Fan Speed.
AS*12LSACW
Operation mod e Air flow mode Speed (rpm)
Hi 1470
Me+ 1420
Me 1290
Lo 1110
Quiet 980
Cool air
prevention
850
Heating
S-Lo 480
Hi 1400
Me 1200
Lo 1000
Cooling Fan
Quiet
820
Dry 820
AS*12LSBCW
Operation mode
Air flow mode Speed (rpm)
Hi 1440
Me+ 1350
Me 1200
Lo 1000
Quiet 760
Cool air
prevention
760
Heating
S-Lo 480
Hi 1370
Me 1150
Lo 950
Cooling Fan
Quiet
700
Dry 700
AS*18LSBCW
Operation mode Air flow mode Speed (rpm)
Hi 1480
Me+ 1420
Me 1300
Lo 1110
Quiet 950
Cool air
prevention
850
Heating
S-Lo 480
Hi 1480
Me 1260
Lo 1040
Cooling Fan
Quiet
850
Dry 850
05-05