Fujitsu AU*24LUAR, AU*54LUAS, AU*45LUAS, AO*24LMAKL, AO*30LMAWL Service Instruction

...
SPLIT TYPE ROOM AIR CONDITIONER
CASSETTE
type
Models Indoor unit Outdoor unit
AU*24LUAR AU*30LUAS AU*36LUAS AU*45LUAS AU*54LUAS
INVERTER
SERVICE
INSTRUCTION
R410A
CONTENTS
1. SPECIFICATIONS
SPECIFICATIONS.......................................................................................................... 01-01
2. DIMENSIONS
DIMENSIONS.................................................................................................................. 02-01
3. REFRIGERANT SYSTEM DIAGRAM
REFRIGERANT CIRCUIT............................................................................................... 03-01
4. CIRCUIT DIAGRAM
CIRCUIT DIAGRAM........................................................................................................ 04-01
5. DESCRIPTION OF EACH CONTROL OPERATION
5-1-1 COOLING CAPACITY CONTROL......................................................................
5-1 COOLING OPERATION............................................................................................
5-4 AUTO CHANGEOVER OPERATION........................................................................
5-5 INDOOR FAN CONTROL.........................................................................................
5-6 OUTDOOR FAN CONTROL......................................................................................
5-7 LOUVER CONTROL.................................................................................................
05-01
05-01
5-2-1 HEATING CAPACITY CONTROL......................................................................
5-2 HEATING OPERATION.............................................................................................
05-02
05-02
5-3-1 INDOOR UNIT CONTROL.................................................................................
5-3 DRY OPERATION......................................................................................................
05-03
05-03
05-04
05-05
05-07
05-08
5-8 COMPRESSOR CONTROL......................................................................................
05-09
5-9 TIMER OPERATION CONTROL...............................................................................
05-11
5-10 ELECTRONIC EXPANSION VALVE CONTROL....................................................
05-13
5-11 TEST OPERATION CONTROL...............................................................................
05-13
5-12 PREVENT TO START FOR 3 MINUTES (3 MINUTES ST)....................................
05-13
5-13 4-WAY VALVE EXTENSION SELECT....................................................................
05-13
5-14 AUTO RESTART.....................................................................................................
05-13
5-15 PUMP DOWN (For AU*30/ 36/ 45/ 54LUAS)..........................................................
05-14
5-16 COMPRESSOR PREHEATING...............................................................................
05-14
5-17 DEFROST OPERATION CONTROL.......................................................................
05-15
5-19 ENERGY SAVE FUNCTION....................................................................................
05-18
5-20 VARIOUS PROTECTIONS......................................................................................
05-19
5-18 DRAIN PUMP OPERATION....................................................................................
05-18
6. REFRIGERANT CAUTION -R410A-
6-1 R410A TOOLS............................................................................................................ 06-01
6-2 PRECAUTION FOR INSTALLATION.........................................................................
06-02
6-3 PRECAUTION FOR SERVICING...............................................................................
06-04
6-4 NEW REFRIGERANT R410A.....................................................................................
06-05
6-5 DEFFERENCE FROM CONVENTIONAL MODEL (R22) AND PRECAUTIONS.......
06-08
8. APPENDING DATA
9. INSTALLATION MANUAL
8-1 CAPACITY TABLE..................................................................................................... 08-01
8-2 OPERATION RANGE.................................................................................................
08-06
8-3 ELECTRIC CHARACTERISTICS...............................................................................
08-07
8-4 SAFETY DEVICE........................................................................................................
08-09
8-5 FUNCTION SETTING.................................................................................................
08-11
7-1-2 OUTDOOR UNIT DISPLAY................................................................................
7-1-1 WIRED REMOTE CONTROLLER DISPLAY......................................................
7-1 ERROR DISPLAY......................................................................................................
7. TROUBLE SHOOTING
7-2 TROUBLE SHOOTING WITH ERROR CODE..........................................................
7-3 TROUBLE SHOOTING WITH NO ERROR CODE....................................................
7-4 SERVICE PARTS INFORMATION............................................................................
07-01
07-01
8-5-1 INDOOR UNIT....................................................................................................
08-11
8-5-2 OUTDOOR UNIT (AO*30/ 36LMAWL)................................................................
08-13
8-5-3 OUTDOOR UNIT (AO*45/ 54LJBYL)..................................................................
08-15
8-5-4 WIRED REMOTE CONTROLLER......................................................................
08-17
07-03
07-24
07-04
07-29
1-1-1 PARTS LAYOUT DRAWING...............................................................................
1-1-2 WIRING................................................................................................................
1-1-3 DISASSEMBLY PROCESS.................................................................................
1-1 For AOU18/ 24LMAKL............................................................................................
1 REPLACEMENT PARTS ( For OUTDOOR UNIT ).......................................................
10. REPLACEMENT PARTS
10-01
10-01 10-01
10-04
10-03
2-1 PARTS LAYOUT DRAWING...................................................................................
2 REPLACEMENT PARTS ( For INDOOR UNIT )........................................................... 10-36
10-36
1-2-1 PARTS LAYOUT DRAWING...............................................................................
1-2-2 WIRING................................................................................................................
1-2-3 DISASSEMBLY PROCESS.................................................................................
1-2-4 ASSEMBLY PROCESS of INVERTER UNIT......................................................
1-2 For AO*30/ 36LMAWL.............................................................................................
10-08 10-08
10-11
10-10
10-16
1-3-1 PARTS LAYOUT DRAWING...............................................................................
1-3-2 WIRING................................................................................................................
1-3-3 DISASSEMBLY PROCESS.................................................................................
1-3-4 ASSEMBLY PROCESS of INVERTER UNIT......................................................
1-3 For AO*45/ 54LJBYL..............................................................................................
10-21 10-21
10-25
10-23
10-31
1 . SPECIFICATIONS
R410A
CASSETTE type
INVERTER
COOLING
kW
BTU/h
kW
BTU/h
COOLING RATED / MAX
HEATING RATED / MAX
COOLING RATED / MAX
HEATING RATED / MAX
A
COOLING
HEATING
l/h(pints/h)
High
Med
Low
OUTDOOR High
High
Med
Low
Quiet
High
Low
INDOOR
OUTDOOR
INDOOR
OUTDOOR
High
Med
Low
W
Fin Pitch
Coil Dimensions
Fin Pitch
Coil Dimensions
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
LIQUID
GAS
m
m
CHARGE g
mm
Note: Specifications are based on the following conditions. Cooling: Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB. Heating: Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB. Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
INDOOR FAN SPEED COOL/HEAT
46/46
44/44
39/39
52/54
Turbo × 1
Propeller × 1
40
65
Aluminium
2 × 30
630 × 901 × 36.38
1300
Copper tube
Copper tube
AVAILABLE VOLTAGE RANGE 198-264V 50Hz
CEUROPEAN ENERGY LABEL
743 × 984 × 413
355 × 1060 × 1025
Inverter
White (5Y9/0.5NN)
Beige(10YR7.5/1.0NN)
2 × 10
210 × 970 × 26.6
1.45
Aluminium
1.30
34/44(75/97)
54/58(119/128)
1800
15.88(5/8inc)
25(chargeless: 10)
FLARE
9.52(3/8inc)
10.5/13.0
10
2.81
3.25
246 × 830 × 830
650 × 830 × 320
7.10/8.00
24200/27300
7.80/9.00
26600/30700
2.0(4.2)
2.53/2.98
2.40/2.98
11.1/13.0
REMOTE CONTROLLER Wired
ABS
DRAIN PIPE
MATERIAL
SIZE
Outer diameter 37.0/Inner diameter 32.0
DIMENSIONS H × W × D
mm
MAX LENGTH
SIZE
mm
kg(lbs) WEIGHT
CONNECTION METHOD
NET
GROSS
POE
15
TYPE
R410ATYPE
MAX HEIGHT
REFRIGERANT OIL
REFRIGERANT
PIPE
NET / GROSS
kW INPUT POWER
COOLING
HEATING
CURRENT
dB(A)
STARTING CURRENT
MOISTURE REMOVAL
kW/kW
INVERTER HEAT PUMP TYPE
CASSETTE MODELS
TYPE
230V 50Hz
RATED / MAX
INDOOR
OUTDOOR
POWER SOURCE
MODEL NAME
CAPACITY
RATED / MAX
AU 24LUAR
AO 24LMAKL
A
NOISE LEVEL (SOUND PRESSURE)
COOL/HEAT
INDOOR
AIR CIRCULATION COOL/HEAT
m
3
/h
EER
COP
FAN MOTOR OUTPUT W
INDOOR
1250/1250
1080/1080
920/920
3200/3200
Coil
OUTDOOR
r.p.m
400/400
-
540/490
480/430
390/340
OUTPUT
780/780
HEAT EXCHANGER TYPE
FAN TYPE x Q'ty
OUTDOOR
Coil
Fin
Fin
mm
COMPRESSOR
OUTDOOR
INDOOR
OUTDOOR
Hermetic type, 4 poles, DC motor, TWIN ROTARY
Rows x Stages
mm
Rows x Stages
TYPE
STARTING METHOD
INDOOR
CASING COLOR
01-01
1. SPECIFICATIONS
01-02
AU 30LUAS AU 36LUAS
AO 30LMAWL AO 36LMAWL
230V 50Hz 230V 50Hz
C E
kW 8.50/10.00 10.00/11.20
BTU/h 29000/34100 34100/38200
kW 10.00/11.20 11.20/12.77
BTU/h 34100/38200 38200/43600
COOLING RATED/MAX 2.86/3.46 4.01/4.08
HEATING RATED/MAX 2.84/3.37 3.49/4.15
COOLING RATED/MAX 12.5/15.2 17.6/17.9
HEATING RATED/MAX 12.4/14.8 15.2/18.2
A 15 15
COOLING 2.97 2.49
HEATING 3.52 3.21
l/h (pints/h) 3.0(6.3) 4.0(8.4)
High
Med
Low
OUTDOOR High
High
Med
Low
Quiet
OUTDOOR High
INDOOR
OUTDOOR
INDOOR
OUTDOOR
High
Med
Low
53.0/55.0 54.0/55.0
W
Fin Pitch
Coil Dimensions
Fin Pitch
Coil Dimensions
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
LIQUID
GAS
m
m
CHARGE g
COOLING
HEATING
mm
Note: Specifications are based on the following conditions. Cooling: Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB. Heating: Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB. Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
600/600
490/490
420/420
-/-
CASSETTE MODELS
INVERTER HEAT PUMP TYPE
INVERTER
Turbo × 1
Propeller × 1
100
103
DC TWIN ROTARY(INVERTER)
1300
850/900
Copper tube
Aluminium
2 × 12
252 × 970 × 26.6
1.30
Copper tube
Aluminium
798 × 900 × 36.38
2 × 38
1.30
White(5Y9/0.5NN)
Beige(10YR7.5/1.0NN)
296 × 830 × 830
830 × 900 × 330
455 × 1060 × 1025
970 × 1050 × 445
37/52(82/115)
FLARE
9.52(3/8 inc.)
15.88(5/8 inc.)
64/70(141/154)
50(chargeless:15)
WIRED
ABS
30
R410A
2200
POE
Outer diameter 37.0 / Inner diameter 32.0
1550/1550
1300/1300
1100/1100
3600/3800
48.0/48.0
44.0/44.0
41.0/41.0
-10 to 43
-10 to 24
FAN MOTOR OUTPUT W
OUTDOOR
NOISE LEVEL (SOUND PRESSURE)
COOL/HEAT
Fin
Coil
INDOOR
HEAT EXCHANGER TYPE
OUTDOOR
TYPE
HEATING
CAPACITY
RATED/MAX
TYPE
MODEL NAME
OUTDOOR
POWER SOURCE
INDOOR
FAN TYPE x Q'ty
A
FAN SPEED COOL/HEAT
INDOOR
MOISTURE REMOVAL
STARTING CURRENT
INDOOR
EER
COP
r.p.m
REMOTE CONTROLLER
DRAIN PIPE
MATERIAL
REFRIGERANT
SIZE
TYPE
OPERATION(OUTDOOR) °C
TYPE
INDOOR
MAX LENGTH
Rows × Stages
mm
Rows × Stages
mm
OUTPUT
NET
CASING COLOR
STARTING METHOD
COMPRESSOR
REFRIGERANT OIL
mm
kg(lbs)
DIMENSIONS H × W × D
WEIGHT
NET / GROSS
PIPE
MAX HEIGHT
mm
CONNECTION METHOD
SIZE
AVAILABLE VOLTAGE RANGE
GROSS
Coil
dB(A)
INDOOR
OUTDOOR
Fin
198-264V 50Hz
EUROPEAN ENERGY LABEL
m3/h
kW
AIR CIRCULATION COOL/HEAT
CURRENT
kW/kW
RATED/MAX
INPUT POWER
COOLING
01-03
CASSETTE TYPE
INVERTER HEAT PUMP TYPE
AU 45LUAS
AO 45LJBYL
230V 50Hz
198-264V 50Hz
kW 12.5 / 14.0
BTU/h 42700 / 47800
kW 14.0 / 16.0
BTU/h 48000 / 56300
COOLING RATED / MAX 4.45 / 5.15
HEATING RATED / MAX 3.95 / 4.60
COOLING RATED / MAX 19.5 / 22.6
HEATING RATED / MAX 17.3 / 20.0
A 15
COOLING 2.81
HEATING 3.54
l/h(pints/h) 4.5(9.5)
High 1700/1700
Med 1420/1420
Low 1200/1200
Quiet -
High 6600/6600
Low -
High 680/680
Med 580/580
Low 500/500
Quiet -
High
Upper fan : 850/850
Lower fan : 750/750
Low -
Turbo × 1
Propeller × 2
INDOOR 100
OUTDOOR 103 × 2
High 50 / 50
Med 48 / 48
Low 45 / 45
Quiet -
High 54 / 55.5
Low -
DC SCROLL(INVERTER)
W 2500
Inverter
Copper tube
Aluminium
3 × 12
Fin Pitch
1.4
Coil Dimensions
252 × 970 × 39.9
Copper tube
Aluminium
2 × 60
Fin Pitch
1.3
Coil Dimensions
1260 × 900 × 36.38
White(5Y9/0.5NN)
Beige(10YR7.5/1.0NN)
INDOOR 296 × 830 × 830
OUTDOOR 1290 × 900 × 330
INDOOR 455 × 1060 × 1025
OUTDOOR 1430 × 1050 × 445
INDOOR 40/55(88/121)
OUTDOOR 105/112(231/247)
FLARE
LIQUID 9.52(3/8 inc.)
GAS 15.88(5/8 inc.)
m 70 (chargeless:20)
m 30
R410A
CHARGE g 3400
POE
COOLING -15 to 43
HEATING -15 to 24
WIRED
ABS
mm Outer diameter 37.0 / Inner diameter 32.0
Note: Specifications are based on the following conditions. Cooling: Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB. Heating: Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB. Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
INDOOR
kW/kW
A CURRENT
m3/h
INDOOR
AIR CIRCULATION COOL/HEAT
OUTDOOR
COOLING
FAN TYPE x Q'ty
TYPE
FAN MOTOR OUTPUT W
COMPRESSOR
OUTDOOR
dB(A)
INDOOR
NOISE LEVEL (SOUND PRESSURE)
COOL/HEAT
WEIGHT
TYPE
RATED / MAX
INDOOR
OUTDOOR
POWER SOURCE
MODEL NAME
CAPACITY
RATED / MAX
AVAILABLE VOLTAGE RANGE
DRAIN PIPE
MATERIAL
SIZE
DIMENSIONS H × W × D
MAX LENGTH
PIPE
SIZE
REMOTE CONTROLLER
NET / GROSS
mm
OUTPUT
TYPEREFRIGERANT OIL
REFRIGERANT
TYPE
GROSS
Coil
OUTDOOR
Coil
CASING COLOR
mm
Rows × Stages
STARTING METHOD
CONNECTION METHOD
kg(lbs)
NET
Rows × Stages
mm
INDOOR
OUTDOOR
mm
MAX HEIGHT
HEAT EXCHANGER TYPE
HEATING
STARTING CURRENT
MOISTURE REMOVAL
Fin
Fin
kW INPUT POWER
OUTDOOR
EER
COP
OPERATION(OUTDOOR) °C
FAN SPEED
COOL/HEAT
INDOOR
r.p.m
OUTDOOR
INDOOR
01-04
AUT30LUAS AUT36LUAS
AOT30LMAWL AOT36LMAW L
240V 50Hz 240V 50Hz
kW 8.50 / 10.00 10.00 / 11.20
BTU/h 29000 / 34100 34100 / 38200
kW 10.00 / 11.20 11.20 / 12.77
BTU/h 34100 / 38200 38200 / 43600
COOLING RATED/MAX 2.86 / 3.50 4.01 / 4.20
HEATING RATED/MAX 2.84 / 3.50 3.49 / 4.20
COOLING RATED/MAX 12.0 / 14.6 16.8 / 17.5
HEATING RATED/MAX 11.9 / 14.6 14.6 / 17.5
A 15 15
EER COOLING 2.97 2.49
COP HEATING 3.52 3.21
l/h (pints/h) 3.0(6.3) 4.0(8.40)
High
Med
Low
OUTDOOR High
High
Med
Low
Quiet
OUTDOOR High
INDOOR
OUTDOOR
INDOOR
OUTDOOR
High
Med
Low
53.0 / 55.0 54.0 / 55.0
W
Fin Pitch
Coil Dimensions
Fin Pitch
Coil Dimensions
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
LIQUID
GAS
m
m
CHARGE g
COOLING
HEATING
mm
Note: Specifications are based on the following conditions. Cooling: Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB. Heating: Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB. Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
Copper tube
Aluminium
2 × 12
252 × 970 × 26.6
1.30
620 / 620
510 / 510
440 / 440
-
CASSETTE MODELS
INVERTER HEAT PUMP TYPE
INVERTER
Turbo × 1
Propeller × 1
100
103
DC TWIN ROTARY(INVERTER)
1300
850 / 900
Copper tube
Aluminium
798 × 900 × 36.38
2 × 38
1.30
White(5Y9/0.5NN)
Beige(10YR7.5/1.0NN)
296 × 830 × 830
830 × 900 × 330
455 × 1060 × 1025
970 × 1050 × 445
52 (115)
FLARE
37 (82)
64 (141)
9.52(3/8 inc.)
15.88(5/8 inc.)
70 (154)
50(chargeless:15)
WIRED
ABS
30
R410A
2200
POE
Outer diameter 37.0 / Inner diameter 32.0
1600 / 1600
1350 / 1350
1150 / 1150
3600 / 3800
48.0 / 48.0
44.0 / 44.0
41.0 / 41.0
-10 to 43
-10 to 24
W
OUTDOOR
NOISE LEVEL (SOUND PRESSURE)
COOL/HEAT
Fin
Coil
INDOOR
HEAT EXCHANGER TYPE
OUTDOOR
TYPE
Rows x Stages
TYPE
MODEL NAME
OUTDOOR
POWER SOURCE
INDOOR
RATED/MAX
INPUT POWER
COOLING
HEATING
CAPACITY
RATED/MAX
STARTING CURRENT
REMOTE CONTROLLER
CASING COLOR
STARTING METHOD
Fin
COMPRESSOR
Rows x Stages
mm
INDOOR
INDOOR
DRAIN PIPE
MATERIAL
REFRIGERANT
SIZE
TYPE
OPERATION(OUTDOOR) °C
REFRIGERANT OIL
TYPE
mm
WEIGHT
NET
kg(lb)
DIMENSIONS H × W × D
GROSS
GROSS
NET
PIPE
MAX HEIGHT
mm
CONNECTION METHOD
SIZE
MAX LENGTH
AVAILABLE VOLTAGE RANGE 198-264V 50Hz
m3/h
kW
AIR CIRCULATION COOL/HEAT
CURRENT
kW/kW
A
INDOOR
MOISTURE REMOVAL
r.p.m
OUTPUT
INDOOR
OUTDOOR
dB(A)
FAN TYPE x Q'ty
Coil
mm
FAN MOTOR OUTPUT
FAN SPEED COOL/HEAT
01-05
CASSETTE MODELS
INVERTER HEAT PUMP TYPE
AUT45LUAS
AOT45LJBYL
240V 50Hz
198-264V 50Hz
kW 12.5 / 14.0
BTU/h 42700 / 47800
kW 14.0 / 16.0
BTU/h 48000 / 56300
COOLING RATED / MAX
4.45 / 5.15
HEATING RATED / MAX 3.95 / 4.60
COOLING RATED / MAX 18.6 / 22.6
HEATING RATED / MAX 16.6 / 20.0
A
15
EER COOLING 2.81
COP HEATING 3.54
l/h(pints/h)
4.5(9.5)
High 1750/1750
Med 1470/1470
Low 1250/1250
Quiet -
High 6600/6600
Low -
High 700/700
Med 600/600
Low 520/520
Quiet -
High Upper fan 850 , Lower fan 750
Low -
INDOOR
Turbo × 1
OUTDOOR P ropeller × 2
INDOOR
100
OUTDOOR 103 × 2
High
51 / 51
Med 49 / 49
Low 46 / 46
Quiet -
54 / 55.5
DC SCROLL(INVERTER)
W
2500
Inverter
Copper tube
Aluminium
3 × 12
Fin Pitch
1.4
Coil Dimensions
252 × 970 × 39.9
Copper tube
Aluminium
2 × 60
Fin Pitch
1.3
Coil Dimensions
1260 × 900 × 36.38
INDOOR W hite(5Y9/0.5NN)
OUTDOOR Beige(10YR7.5/1.0NN)
INDOOR
296 × 830 × 830
OUTDOOR
1290 × 900 × 330
INDOOR
455 × 1060 × 1025
OUTDOOR
1430 × 1050 × 445
INDOOR
40/55 (88/121)
OUTDOOR 105/112 (231/247)
FLARE
LIQUID 9.52(3/8 inc.)
GAS 15.88(5/8 inc.)
m 70 (chargeless:20)
m
30
R410A
CHARGE g 3400
POE
COOLING -15 to 43
HEATING -15 to 24
WIRED
ABS
mm
Outer diameter 37.0 / Inner diameter 32.0
Note: Specifications are based on the following conditions. Cooling: Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB. Heating: Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB. Pipe length : 7.5 m , Height difference : 0 m.(Outdoor unit - Indoor unit)
Rows x Stages
Rows × Stages
mm
INDOOR
STARTING METHOD
Fin
Fin
m3/h
INDOOR
AIR CIRCULATION COOL/HEAT
AVAILABLE V OLTAGE RANGE
COOLING
OUTDOOR
kWINPUT POWE R
kW/ kW
A
FAN TYPE × Q'ty
TYPE
FAN MOTOR OUTPUT W
COMPRESSOR
NOISE LEVEL (SOUND PRESSURE)
COOL/HEAT
OUTPUT
dB(A)
OUTDOOR
TYPE
RATED / MAX
INDOOR
OUTDOOR
POWER S OURCE
MODEL NAME
CAPACITY
RATED / MAXHEATING
DRAIN PIPE
MATERIAL
SIZE
DIMENSIONS H × W × D
MAX LENGTH
PIPE
SIZE
kg(lbs)
NET
°C
CASING COLOR
mm
Coil
OUTDOOR
REMOTE CONTROLLER TYPE
NET / GROSS
mm
CONNECTION METHOD
TYPEREFRIGERANT OIL
REFRIGERANT
TYPE
OPERATION(OUTDOOR)
STARTING CURRENT
MOISTURE REMOVA L
FAN SPEE D
COOL/HEAT
INDOOR
CURRENT
MAX HEIGHT
WEIGHT
r.p.m
OUTDOOR
INDOOR
mm
HEAT EXCHANGER TYPE
GROSS
Coil
AUT54LUAS
AOT54LJBYL
240V 50Hz
198-264V 50Hz
14.0 / 14.5
47800 / 49500
16.0 / 16.5
54600 / 56300
5.60 / 5.70
4.85 / 5.20
23.5 / 24.0
20.4 / 21.8
15
2.50
3.30
5.5(11.6)
1750/1750
1470/1470
1250/1250
-
6600/6600
-
700/700
600/600
520/520
-
Upper fan : 850 , Lower fan : 750
-
Turbo × 1
Propeller × 2
100
103 × 2
51 / 51
49 / 49
46 / 46
-
54 / 55.5
DC SCROLL(INVERTER)
2500
Inverter
Copper tube
Aluminium
3 × 12
1.4
252 × 970 × 39.9
Copper tube
Aluminium fin
2 × 60
1.3
1260 × 900 × 36.38
White(5Y9/0.5NN)
Beige(10YR7.5/1.0NN)
296 × 830 × 830
1290 × 900 × 330
455 × 1060 × 1025
1430 × 1050 × 445
40/55 (88/121)
105/112 (231/247)
FLARE
9.52(3/8 inc.)
15.88(5/8 inc.)
70 (chargeless : 20)
30
R410A
3400
POE
-15 to 43
-15 to 24
WIRED
ABS
Outer diameter 37.0 / Inner diameter 32.0
2 . DIMENSIONS
R410A
CASSETTE type
INVERTER
02-01
350
830
650
12
101
154
320
58
90
Top view
Front view
Side view
(Unit : mm)
(Unit : mm)
940 30
940
235
Drain inside Dia. 32
outside Dia. 37
750
830
750
830
Bottom view
305.5
298.5
248.5
200
60
(Drain pipe)
100
(Small pipe)
70
(Large pipe)
Side view (Slender setting)
Bottom view (Panel)
Side view (Standard setting)
2. DIMENSIONS
MODEL : AU*24LUAR
MODEL : AO*24LMAKL
02-02
MODEL : AU*30/ 36LUAS
MODEL : AO*30/ 36LMAWL
(Unit : mm)
900
830
99
196
21
9
77
31 330
400
170
147
12
Top view
Front view
Side view
750
830
750
830
Bottom view
Side view (Slender setting)
940
30
60
285
120
150
(Small pipe)
(Drain pipe)
(Large pipe)
250
940
305.5
298.5
248.5
Drain Inside Dia. 32
Dia. 37Outside
Bottom view (Panel)
Side view (Standard setting)
(Unit : mm)
02-03
MODEL : AU*45/ 54LUAS
MODEL : AO*45/ 54LJBYL
(Unit : mm)
900
1290
77 31
21
9
400
151
99
196
170
12
330
Top view
Side view
Front view
750
830
750
830
Bottom view
(Unit : mm)
Side view (Slender setting)
940
30
60
285
120
150
(Small pipe)
(Drain pipe)
(Large pipe)
250
940
305.5
298.5
248.5
Drain Inside Dia. 32
Dia. 37Outside
Bottom view (Panel)
Side view (Standard setting)
3 . REFRIGERANT SYSTEM DIAGRAM
R410A
CASSETTE type
INVERTER
03-01
Ø15.88mm(5/8")
Ø9.52mm(3/8")
3. REFRIGERANT CIRCUIT
MODEL : AU*24LUAR / AO*24LMAKL
Outdoor Unit Indoor Unit
CONDENSER EVAPOLATOR
HIGH PRESSURE SWITCH
THO
THO
THPO
THD
THR
THR
THPI
THPI
THD
THPO
COMPRESSOR
ACCUMULATOR
EXPANSION VALVE
STRAINER
MUFFLER
4-Way valve
THERMISTOR(DISCHARGE TEMP.)
THERMISTOR(ROOM TEMP.)
THERMISTOR(PIPE TEMP.)
THERMISTOR(OUTDOOR TEMP.)
THERMISTOR(PIPE TEMP.)
Refrigerant Pipe
Refrigerant Pipe
COOL HEAT
03-02
Ø15.88mm(5/8")
Ø9.52mm(3/8")
MODEL : AU*30/ 36LUAS / AO*30/ 36LMAWL
Outdoor Unit Indoor Unit
CONDENSER
HIGH PRESSURE SWITCH
PRESSURE CHECK VALVE
THO
THO
THC
THPO
THD
THR
THR
THPI
THPI
THD
THC
THPO
COMPRESSOR
ACCUMULATOR
EXPANSION VALVE
STRAINERSTRAINER
4-Way valve
THERMISTOR(DISCHARGE TEMP.)
THERMISTOR(ROOM TEMP.)
THERMISTOR(PIPE TEMP.)
THERMISTOR(OUTDOOR TEMP.)
THERMISTOR(PIPE TEMP.)
THERMISTOR(COMP TOP TEMP.)
Refrigerant Pipe
Refrigerant Pipe
COOL HEAT
EVAPOLATOR
Charging Valve
Charging Valve
03-03
Ø15.88mm(5/8")
Ø9.52mm(3/8")
MODEL : AU*45/ 54LUAS / AO*45/ 54LJBYL
Outdoor Unit Indoor Unit
CONDENSER
HIGH PRESSURE SWITCH
PRESSURE CHECK VALVE
THO
THO
THC
THPO
THD
THR
THPI
THR
THPI
THD
THC
THPO
COMPRESSOR
ACCUMULATOR
EXPANSION VALVE
STRAINER
STRAINER STRAINER
4-Way valve
THERMISTOR(DISCHARGE TEMP.)
THERMISTOR(ROOM TEMP.)
THERMISTOR(PIPE TEMP.)
THERMISTOR(OUTDOOR TEMP.)
THERMISTOR(PIPE TEMP.)
THERMISTOR(COMP TOP TEMP.)
Refrigerant Pipe
Refrigerant Pipe
COOL HEAT
EVAPOLATOR
Charging Valve
Charging Valve
MUFFLER
4 . CIRCUIT DIAGRAM
R410A
CASSETTE type
INVERTER
04-01
4. CIRCUIT DIAGRAM
MODEL : AU*24LUAR
TO REMOTE CONTROL UNIT
TERMINAL
1
2
3
1
2
3
THERMISTOR (PIPE TEMP.)
THERMISTOR (ROOM TEMP.)
STEPPING MOTOR
FLOAT SWITCH
DRAIN PUMP MOTOR
FAN MOTOR
FAN MOTOR CAPACITOR
BROWN
RED
RED
GRAY
GRAY
BLACK
BLACK
WHITE
RED
GRAY
GRAY
BLACK
WHITE
BLACK
ORANGE
YELLOW
WHITE
BLACK
BLACK
BLACK
GREEN
WHITE
BLACK
RED
WHITE
GREEN/YELLOW
BLACK
BLACK
WHITE
WHITE
WHITE
RED
PURPLE
BLUE
BLACK
BLACK
BLACK
YELLOW
YELLOW
BROWN
RED
ORANGE
YELLOW
WHITE
1 2 3 4 5
1 2 3 5 6
1 2 3 5 6
1 2 3
1 2 3
1 2 1 2
1 21 2
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2
121
2
121
2
1 2
121
2
1 2 3
1 2 3
1 2 3
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
CN10CN15
CN6
CN1CN3
CN16CN5CN4
CN7
CN17
CN8
CONTROL BOARD
TO OUTDOOR UNIT
TERMINAL
THERMAL
FUSE 102 C
L N
FILTER BOARD
Use T 3.15A 250V
Fuse on F101
FM
04-02
MODEL : AU*30/ 36/ 45/ 54LUAS
TO REMOTE CONTROL UNIT
TERMINAL
1
2
3
1
2
3
THERMISTOR (PIPE TEMP.)
THERMISTOR (ROOM TEMP.)
STEPPING MOTOR
FLOAT SWITCH
DRAIN PUMP MOTOR
FAN MOTOR
FAN MOTOR CAPACITOR
BROWN
RED
RED
GRAY
GRAY
BLACK
BLACK
WHITE
RED
GRAY
GRAY
BLACK
WHITE
BLACK
ORANGE
YELLOW
WHITE
BLACK
BLACK
BLACK
GREEN
WHITE
BLACK
BLACK
WHITE
WHITE
WHITE
RED
BLACK
BLACK
BLACK
YELLOW
YELLOW
BROWN
RED
ORANGE
YELLOW
WHITE
1 2 3 4 5
1 3 5
1 3 5
2 1 3
2 1 3
1 2 3
1 2 3
1 2
1 2 1 2
1 2
1 2 3
1 2 3
1 2 3
1 2
121
2
121
2
1 2
121
2
1 2 3
1 2 3
1 2 3
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
CN10
CN15
CN6
CN1
CN3
CN5
CN4
CN7
CN17
CN8
CONTROL BOARD
TO OUTDOOR UNIT
TERMINAL
THERMAL
FUSE 102 C
L N
FILTER BOARD
Use T 3.15A 250V
Fuse on F101
FM
04-03
MODEL : AO*24LMAKL
ACTIVE FILTER MODULE
WHITE
WHITE
CHOKE COIL
CAPACITOR
CN11
CN407
CN37
CN38
CN21
CN22
CN23
CN25
L1
N1
P
L2
1 2 3 4 5 6
1 2 3 4
+
-
BROWN
YELLOW
YELLOW WHITE
PURPLE
BLUE
RED
RED
WHITE
BLACK
BLACK
BLUE
RED
RED BROWN BLUE ORANGE YELLOW WHITE
BLACK
BLACK BLACK
WHITE
WHITE
GREEN
RED
WHITE
BLACK
BLACK
BLACK
BLACK
BLACK
RED
RED
BROWN
BROWN
BLACK
BLUE
BROWN
ORANGE
W10 W11 TM104 TM105
TM305
TM304
TM303
CN30
CN11
CN27
W102
W103
W4 W5 W8 W1 W2 W3
FUSE F2 T 3.15A 250V
FUSE F4 T 5A 250V
PRINTED CIRCUIT BOARD
4WV
COMPRESSOR
FAN MOTOR
FAN CAPACITOR
EXPANSION VALVE COIL A
U
V
W
1 2 3
1 2
1 2
1 2
1 2
1 2
1 2
1 2 3 4 5 6 7
1 2 3 4 5 6
FM
CONNECTOR
EV
TERMINAL
1 2(N) 3 L N
FUSE 25A
COMPRESSOR PRESSURE SW
COMPRESSOR THERMAL SW
THERMISTOR (DISCHARGE)
THERMISTOR (PIPE)
THERMISTOR (OUTDOOR)
THERMISTOR (HEAT SINK)
04-04
MODEL : AO*30/ 36LMAWL
CN21
U W305
V W304
W W303
CN22 CN23 CN26 CN25
CN37
CN30
CN800
CN27
CN1
CN1
TM102
TM101
CN34
W9
W6W3 W7 W4 W5
W8
CN407
W12 W13
W21 W22
W200
W16 W17
W10 W11
1 2
1 2 3 4 1 2 3
1 2 3
1 2 1 2 1 2 1 2
BLACK
BLACK
WHITE
WHITE
GREEN
1 2(N) 3 L N
TO INDOOR UNIT
TO POWER SUPPLY
1 2
1 2 3
1 2 3 4 5 6 7
1 2 3 4 5 6
1 2 3 4 5
1 2 3 4 5 6
FUSE F4 T 5A 250V
FUSE F2 T 3.15A 250V
PRINTED CIRCUIT BOARD (MAIN)
RED
BLACK
BLACK
BROWN
BLUE
BLACK
BROWN
BLACK
BLACK WHITE
WHITE
YELLOW
YELLOW
BROWN
BROWN BLUE ORANGE
RED
RED
RED
RED
BLACK
WHITE
WHITE
BLACK
BLACK
ORANGE
BROWN RED
REDRED
WHITEWHITE
BLACKBLACK
ORANGE
YELLOW
YELLOW
BLUE
WHITE
BROWN
ORANGE
RED
BLACK
BROWN
RED
4WV
FM
EV
HIGH PRESSURE SW
SOLENOID COIL
EXPANSION VALVE COIL
FAN MOTOR
THERMISTOR
(HEAT SINK)
THERMISTOR
(DISCHARGE)
THERMISTOR
(PIPE)
THERMISTOR
(OUTDOOR)
THERMISTOR
(COMPRESSOR)
PRINTED CIRCUIT BOARD (FILTER)
EARTH
FUSE
10A
FUSE
25A
POSISTOR
TERMINAL
CHOKE COIL
ACTIVE FILTER MODULE
L1
L2
P N
EMI FILTER 2T
EMI FILTER 1T
CONNECTOR
COMPRESSOR
U
W
V
04-05
MODEL : AO*45/ 54LJBYL
CN21
U W305
V W304
W W303
CN22 CN23 CN26 CN25
CN37
CN30
CN800
CN801
CN27
CN1
CN1
TM102
TM101
CN34
W9
W6W3 W7 W1 W2
W8
CN407
W14 W15
W107 W108
W200
1 2
1 2 3 4 1 2 3
1 2 3
1 2 1 2 1 2 1 2
BLACK
BLACK
GRAY
RED
BLACK
GRAY
BLACK
WHITE
WHITE
GREEN
1 2(N) 3 L N
1 2
1 2 3
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6
1 2 3 4 5
1 2 3 4 5 6
F4 T 5A 250V F2 T 3.15A 250V
PRINTED CIRCUIT BOARD (MAIN)
RED
BLACK
BLACK
BROWN
BLUE
BLACK
BROWN
BLACK
BLACK WHITE
WHITE
YELLOW
YELLOW
BROWN
BROWN BLUE ORANGE
RED
RED
BLACK WHITE YELLOW BROWN
RED
RED
RED
BLACK
WHITE
WHITE
WHITE
WHITE
BROWN
YELLOW
BLUE
VIOLET
BLACK
ORANGE
BROWN RED
REDRED
WHITEWHITE
BLACKBLACK
ORANGE
YELLOW
ORANGE
BLACK
BROWN
RED
4WV
FM
FM
EV
HIGH PRESSURE SW
SOLENOID COIL
EXPANSION VALVE COIL
FAN MOTOR 1
FAN MOTOR 2
THERMISTOR
(HEAT SINK)
THERMISTOR
(DISCHARGE)
THERMISTOR
(PIPE)
THERMISTOR
(OUTDOOR)
THERMISTOR
(COMPRESSOR)
PRINTED CIRCUIT BOARD (FILTER)
EARTH
FUSE
10A
POSISTOR
CHOKE COIL
ACTIVE FILTER MODULE
L1
L2
P N
EMI FILTER 1T
EMI FILTER 2T
EMI FILTER 2T
EMI FILTER 2T
EMI FILTER 3T
EMI FILTER 1T
CONNECTOR
COMPRESSOR
U
W
V
TERMINAL
TERMINAL
DIODE BRIDGE
RELAY
FUSE
TO INDOOR UNIT
TO POWER SUPPLY
5 . DESCRIPTION OF EACH CONTROL OPERATION
R410A
CASSETTE type
INVERTER
5-1. COOLING OPERATION
5-1-1 COOLING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit will usually perceive difference or variation between a set temperature and present room temperature, and controls the operation frequency of the compressor. * If the room temperature is 2 degC higher than a set temperature, the compressor operation frequency will attain to maximum performance.
* If the room temperature is 2 degC lower than a set temperature, the compressor will be stopped.
* When the room temperature is between +2 degC to -2 degC of the setting temperature, the compressor frequency is controlled within the range shown in Table1. However, the maximum frequency is limited in the range shown in Figure 1 based on the fan speed mode and the outdoor temperature.
minimum frequency
maximum frequency
AU*24LUAR 15Hz
20Hz 20Hz 20Hz
75Hz 90Hz 90Hz 92Hz
AU*30LUAS AU*36LUAS AU*45LUAS
20Hz 92Hz
AU*54LUAS
Outdoor air temperature
A zone
31°C
B zone
C zone
D zone
Hi Me Lo
A zone 75Hz
52Hz 42Hz 36Hz 90Hz 70Hz 65Hz 55Hz 90Hz
92Hz 72Hz 60Hz 60Hz
75Hz 70Hz 65Hz
52Hz 42Hz
52Hz 42Hz
36Hz 36Hz
45Hz 75Hz 70Hz 65Hz 55Hz 72Hz 60Hz
45Hz 75Hz 70Hz
60Hz
60Hz
53Hz
53Hz
65Hz
30Hz 70Hz 65Hz
30Hz 70Hz
55Hz 72Hz 60Hz
65Hz
55Hz
55Hz
B zone C zone
AU*24LUAR
D zone A zone B zone C zone
AU*30LUAS
D zone A zone B zone C zone
AU*36LUAS
D zone A zone B zone
C zone
AU*45LUAS
AU*54LUAS
D zone
92Hz 85Hz 72Hz 67Hz
85Hz 72Hz 67Hz
67Hz
60Hz
60Hz
85Hz 72Hz
A zone B zone C zone D zone
19°C
11°C
( Table 1 : Compressor Frequency Range )
( Fig. 1 : Limit of Maximum Frequency based on Outdoor Temperature )
05-01
Fan speed mode
5. DESCRIPTION OF EACH CONTROL OPERATION
5-2. HEATING OPERATION
5-2-1 HEATING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit will usually perceive difference or variation between a set temperature and present room temperature, and controls the operation frequency of the compressor. * If the room temperature is lower 3 degC than a set temperature, the compressor operation frequency will attain to maximum performance.
* If the room temperature is higher 2 degC than a set temperature, the compressor will be stopped.
* When the room temperature is between +2 degC to -3 degC of the setting temperature, the compressor frequency is controlled within the range shown in Table2. However, the maximum frequency is limited in the range shown in Figure 2 based on the outdoor temperature.
( Table 2 : Compressor Frequency Range )
( Fig.2 : Limit of Maximum Frequency based on Outdoor Temperature )
05-02
Outdoor air temperature
C zone
B zone
A zone
A zone 75Hz
75Hz 75Hz 95Hz 90Hz 80Hz 95Hz 90Hz 80Hz
92Hz 90Hz 80Hz
92Hz 90Hz 80Hz
B zone C zone
A zone B zone C zone
A zone B zone C zone
A zone B zone C zone
A zone B zone C zone
AU*24LUAR
AU*30LUAS
AU*36LUAS
AU*45LUAS
AU*54LUAS
16°C
12°C
Limit of Maximum Frequency
minimum frequency
maximum frequency
AU*24LUAR 15Hz
20Hz 20Hz 20Hz
75Hz 95Hz 95Hz 92Hz
AU*30LUAS AU*36LUAS AU*45LUAS
20Hz 92Hz
AU*54LUAS
5-3. DRY OPERATION
5-3-1 INDOOR UNIT CONTROL
The compressor rotation frequency shall change according to set temperature and room temperature variation which the room temperature sensor of the indoor unit has detected as shown in the Table 3.
Room temperature
Room temperature
Compressor ON
Ts+1.5 degC
Ts+1 degC
Compressor OFF
Compressor
ON
ON
OFF
Indoor fan
air flow mode
Air flow mode : Lo
OFF
30 5 30 120 5 (sec)
180 180
( Table 3 : Compressor frequency )
( Fig.3 : Compressor Control based on Room Temperature )
( Fig.4 : Indoor Fan Control )
05-03
Operating frequency
AU*24LUAR 28Hz
45Hz 45Hz 30Hz
AU*30LUAS AU*36LUAS AU*45LUAS
53Hz
AU*54LUAS
Ts : Setting temperature
5-4. AUTO CHANGEOVER OPERATION
When the air conditioner is set to the AUTO mode by remote control, operation starts in the optimum mode from among the HEATING, COOLING and MONITORING modes. During operation, the optimum mode is automatically swiched in accordance with temperature changes. The temperature can be set between 18°C and 30°C in 1 degC steps.
When operation starts, only the indoor fan is operated for 1 minute. (Air flow mode: S- Lo) After 1 minute, depends on the room temperature and outdoor unit's operarion mode, the operation mode is selected in accordance with the table below.
( Table 4 : Operation mode selection table )
When COOLING was selected at , the same operation as COOLING OPERATION is performed.
When HEATING was selected at , the same operation as HEATING OPERATION is performed.
When the compressor was stopped for 6 consecutive minutes by the temperature control function after the COOLING or HEATING operation mode was selected at above, operation is switched to MONITORING and the operation mode is selected again.
1
1
2
3
1
4
1
05-04
Room temperature :TR
Operation mode
TR > Ts +2 degC
Ts +2 degC > TR
=
=
Ts +2 degC > TR > Ts -2 degC
Cooling
Monitoring
Heating
Ts : Setting temperature
5-5. INDOOR FAN CONTROL
1. Fan speed
( Table 5 : Indoor Fan Speed )
AU*24LUAR
Operation mode Air flow mode Speed (rpm)
Hi 490
430 340 250
Me
Lo
Heating
S-Lo
2. FAN OPERATION
The airflow can be switched in 4 steps such as AUTO, LOW, MED, HIGH, while the indoor fan only runs.
05-05
Hi 540
480 390 250
Me
Lo
Cooling
S-Lo
AU*30LUAS
Operation mode Air flow mode Speed (rpm)
Hi 620
510 440 300
Me
Lo
Heating
S-Lo
Hi 620
510 440 300
Me
Lo
Cooling
S-Lo
AU*36LUAS
Operation mode Air flow mode Speed (rpm)
Hi 620
510 440 300
Me
Lo
Heating
S-Lo
Hi 620
510 440 300
Me
Lo
Cooling
S-Lo
AU*54LUAS
Operation mode Air flow mode Speed (rpm)
Hi 700
600 520 300
Me
Lo
Heating
S-Lo
Hi 700
600 520 300
Me
Lo
Cooling
S-Lo
AU*45LUAS
Operation mode Air flow mode Speed (rpm)
Hi 700
600 520 300
Me
Lo
Heating
S-Lo
Hi 700
600 520 300
Me
Lo
Cooling
S-Lo
When [AUTO] is selected, the indoor fan motor runs LO and OFF at 1 minute intervals.