Fujitsu AS*12LEC, AO*09LECN, AS*09LEC, AO*12LECN Design & Technical Manual

AIR CONDITIONER
Wall Mounted type
INDOOR
OUTDOOR
ASA09LEC ASA12LEC
AOR09LECN AOR12LECN
DESIGN & TECHNICAL MANUAL
1.INDOOR UNIT
WALL MOUNTED TYPE :
ASA09LEC
ASA12LEC
DTR_AS047E_01
2010.10.05
WALL MOUNTED TYPE
AS
A09-12LE
WALL MOUNTED TYPE
AS
A09-12LE
CONTENTS
1. INDOOR UNIT
1. FEATURE
.................................................................................................................. 01 - 01
2. WIRELESS REMOTE CONTROLLER
............................................... 01 - 04
3. SPECIFICATIONS
.............................................................................................. 01 - 06
4. DIMENSIONS
........................................................................................................ 01 - 07
5. WIRING DIAGRAMS
........................................................................................ 01 - 09
6. CAPACITY TABLE
............................................................................................ 01 - 10
6-1. COOLING CAPACITY
...................................................................................... 01 - 10
6-2. HEATING CAPACITY
........................................................................................01 - 11
7. FAN PERFORMANCE AND CAPACITY
.......................................... 01 - 12
7-1. AIR VELOCITY DISTRIBUTION
..................................................................... 01 - 12
7-2. AIR FLOW
.......................................................................................................... 01 - 13
8. OPERATION NOISE
......................................................................................... 01 - 14
8-1. NOISE LEVEL CURVE
.................................................................................... 01 - 14
8-2. SOUND LEVEL CHECK POINT
..................................................................... 01 - 15
9. ELECTRIC CHARACTERISTICS
........................................................... 01 - 16
10. SAFETY DEVICES
............................................................................................ 01 - 17
11-1. EXTERNAL INPUT
........................................................................................... 01 - 18
11-2. EXTERNAL OUTPUT
....................................................................................... 01 - 19
12. FUNCTION SETTING
...................................................................................... 01 - 20
12-1. INDOOR UNIT (Setting by remote controller)
........................................... 01 - 20
13. OPTIONAL PARTS
........................................................................................... 01 - 23
- (01 - 01) -
WALL MOUNTED TYPE
AS
A09-12LE
WALL MOUNTED TYPE
AS
A09-12LE
FEATURE1.
MODEL
ASA09LEC / AOR09LECN ASA12LEC / AOR12LECN
FEATURES
Low outdoor air temperature correspondence
Corresponds to heating operation at -25°C outdoor air temperature
Heating
-25 to 24
°C
Specification improvement that can be operated under extreme low outdoor temperature (-25°C) without trouble
New model
Freezing prevention of bace
Structural improvements
Expansion of mechanical space
Improvement of cold­proof specifications of parts
Powerful Heating at low outdoor temperature
Keeping the high heating capacity at low outdoor temperature.
45%up
3.5
3.2
2.2
2.6
3.3
4.1
3.5
4.1
3.0
17%up
2.9
Heating capacity
(kW)
Outdoor temperature
New model
Current model
Heating capacity
(kW)
2.5 kW Class
2°C -7°C -15°C
3.4 kW Class
- (01 - 02) -
WALL MOUNTED TYPE
AS
A09-12LE
WALL MOUNTED TYPE
AS
A09-12LE
Energy-Efficiency classification A
Europe Energy-Efficiency classification A achieved
ALL DC
Super quiet
Air flow mode can be set in 4 steps and more detailed air flow setting is possible.
Fan speed Noise level
Quiet 21
dB(A)
Easy maintenance
Easy maintenance and always clean. Troublesome maintenance has been made easy.
Since the front panel is easy to remove, maintenance is also easy.
Inner drying operation
This model is equipped with an inner drying function. After the power is turned off, the dry starts inside the air conditioner. This prevents the growth of mold and bacteria inside the air conditioner.
Corresponds to maximum 20m long piping
b
DC
compressor
c
a
b
a
a
c
When operation starts, the machine operates at high voltage and high power and when operation stabilizes, the set temperature is maintained at low voltage.
PAM control
DC fan motor
Front view
During dew
condensation
Approx. 90 mins
Drying
- (01 - 03) -
WALL MOUNTED TYPE
AS
A09-12LE
WALL MOUNTED TYPE
AS
A09-12LE
Air conditioner filter features
Apple­catechin Filter
Long-life Ion Deodorization Filter
Ion Deodorization Filter
Apple-catechin Filter
Dirty Air
Clean Air
- (01 - 04) -
WALL MOUNTED TYPE
AS
A09-12LE
WALL MOUNTED TYPE
AS
A09-12LE
WIRELESS REMOTE CONTROLLER2.
FEATURES
Four kinds of timer setup
(On / Off / Program / Sleep) are possible.
Four kinds of timers. Easy operation.
Easy to change transmission code (4 patterns) by button operation.
Simple function setting
Setting of the air conditioner selection function is performed by remote controller.
Built-in timers
Select from four different timer programs (On/Off/Program/Sleep).
Program timer
The program timer operates the on and off timer once within a 24 hour period.
Sleep timer
The sleep timer function automatically corrects the temperature thermostat setting according to the timer setting to prevent excessive cooling and heating while sleeping.
60min.
1 °C
2 °C
Timer setting
Set temp.
1 °C
30min.
60min.
90min.
2 °C
3 °C
4 °C
Set temp.
Timer setting
Cooling operation/dry operation
When the sleep timer is set, the set temperature automatically rises 1 °C every hour. The set temperature can rise up to a maximum of 2 °C.
Heating operation
When the sleep timer is set, the set temperature automatically drops 1 °C every 30 minutes. The set temperature can drop to a maximum of 4 °C.
Switching remote controller signal code
ABC D
ABCD
Mixed-up
I.U. I.U. I.U. I.U.
I.U. I.U. I.U. I.U.
After code change
Code selector switch eliminates unit
• being wrongly switched. (Up to 4 codes can be set.)
*I.U.=Indoor unit
- (01 - 05) -
WALL MOUNTED TYPE
AS
A09-12LE
WALL MOUNTED TYPE
AS
A09-12LE
FUNCTIONS
Display panel
SPECIFICATION
12
10
11
9
6
13
14
8
15
7
1
5
4
3
2
16
17
20
21
25
26
18
24
23
27
22
19
SIZE (H x W x D mm) 176 x 56 x 18
WEIGHT ( g ) 110
ACCESSORY Holder
1
START/STOP button
2
MODE button
3
10°C HEAT button
4
SET TEMP. button ( / )
5
COIL DRY button
6
Signal transmitter
7
TIMER MODE button
8
TIMER SET ( / ) button
9
FAN b utton
10
ECONOMY button
11
START/STOP button
12
SET button
13
SWING button
14
RESET button
15
TEST RUN button
This button is used when installing the air conditioner, and
should not be used under normal conditions, as it will cause the indoor unit's thermostat function to operate incorrectly.
If this button is pressed during normal operation, the indoor
unit will switch to test operation mode, and the Indoor Unit’s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously.
To stop the test operation mode, press the START/STOP button
to stop the air conditioner.
16
CLOCK ADJUST button
17
Remote controller display
18
Transmit indicator
19
Clock display
20
ECONOMY display
21
Operating mode display
22
Timer mode display
23
Fan speed display
24
Temperature set display
25
COIL DRY display
26
SLEEP display
27
SWING display
- (01 - 06) -
WALL MOUNTED TYPE
AS
A09-12LE
WALL MOUNTED TYPE
AS
A09-12LE
SPECIFICATIONS3.
Note : Specifications are based on the following conditions. Coolin g : Indoor tem perature of 2 7 °CDB / 19 °CWB. and outdoo r temperatu re of 35 °CDB /24 °CWB. Heating : I ndoor temp erature of 2 0 °CDB / 15 °CWB. and outdoor t emperatu re of 7 °CDB/6 ° CWB. Pipe leng th : 5 m, Height d ifferen ce : 0 m.(Outdoo r unit - Indoo r unit)
Typ e
WALL MOUNTED
INVERTER HEAT PUMP Model name ASA09LEC ASA12LEC Power source 230V~ 50Hz Available voltage range 198-26 4V ~ 50Hz
European energy label
Cooling A A Heating A A
Capacity
Cooling
Rated
kW 2.50 3.40
BTU/h 8,500 11,600
Min-Max
kW 0.5 - 3.2 0.9 - 3.9
BTU/h 1,700 - 10,90 0 3,100 - 13,300
Heating
Rated
kW 3.20 4.00
BTU/h 10,900 13,600
Min-Max
kW 0.5 - 4.5 0.9 - 5.6
BTU/h 1,700 - 15,300 3,100 - 19,100
Input power
Cooling
Rated
kW
0.63 0.895
Min-Max 0.25 - 1.27 0.25 - 1.40
Heating
Rated 0.75 0.97 Min-Max 0.25 - 1.60 0.25 - 1.99
Current
Cooling
Rated
A
3.2 4.3
Max 6.0 6.5
Heating
Rated 3.7 4.6 Max 9.5 9.0
EER Cooling
kW/kW
3.97 3.80 COP Heating 4.27 4.12 SENSIBLE CAPACITY Cooling kW 1.60 2.20
POWER FACTOR
Cooling
%
87 91
Heating 89 92
Moisture removal l/h (pints/h) 1.3 ( 2.7 ) 1.8 ( 3.8 )
Fan
Airflow rate
Cooling
High
m
3
/h
735
Med 595
Low 425
Quiet 285
Heating
High 735 Med 595
Low 425
Quiet 285 Type × Q'ty Cross flow fan×1 Motor output W 30
Sound pressure level
Cooling
High
dB(A)
43
Med 38
Low 33
Quiet 21
Heating
High 43 Med 38
Low 33
Quiet 21
Heat exchanger type
Dimensions (H × W × D)
mm
256 × 630 × 20
Fin pitch 1.1 Rows x Stages 2 × 16 Pipe type Copper Fin type Aluminium
Enclosure
Material Polystyrene
Colour
White
Approximate colour of MUNSELL N 9.25/
Dimensions ( H×W ×D )
Net
mm
260 × 790 × 2 02
Gross 259 × 840 × 328
Weight
Net
kg(lb.)
7.5 (1 7)
Gross 9.5 (20)
Connection pipe
Size
Liquid
mm
Φ6.35 (Φ 1/4 in.)
Gas Φ9.52 (Φ 3 /8 in.)
Method Flare
Operation range
Cooling
°C 18 to 32
%RH 80 or less
Heating °C 30 or less
Remote controller type Wireless
Drain pipe
Material PP + LLDPE Size mm Outer diameter: 21 / Inner diameter: 13.6
- (01 - 07) -
WALL MOUNTED TYPE
AS
A09-12LE
WALL MOUNTED TYPE
AS
A09-12LE
DIMENSIONS4.
MODEL  :ASA09LE, ASA12LE
(Unit : mm)
- (01 - 08) -
WALL MOUNTED TYPE
AS
A09-12LE
WALL MOUNTED TYPE
AS
A09-12LE
INSTALLATION PLACE
(Unit : mm)
Outline of indoor unit
52 or more
70 or more
48 or more
100 or more
45 or more
63 or more
1800 or more
1500 or more
- (01 - 09) -
WALL MOUNTED TYPE
AS
A09-12LE
WALL MOUNTED TYPE
AS
A09-12LE
WIRING DIAGRAMS5.
MODEL  :ASA09LE, ASA12LE
TO OUTDOOR UNIT
Loading...