WARNING! BEFORE USING THE WELDING MACHINE READ THE INSTRUCTION
MANUAL CAREFULLY! FOR QUALIFIED AND SPECIALLY TRAINED PERSONS
ONLY AFTER PROPER READING OF THIS MANUAL IS ALLOWED TO USE AND TO
MAINTAINTHIS WELDING MACHINE.
The detailed description, safety rules and all required information necessary for proper operation
and maintenance of FUBAG welding machine are provided below. Keep this instruction manual by
machine and refer to it by any doubts concerning safety operation, maintenance storage and
handling of FUBAG weldingmachine.
1. Safety perationo
It is highly recommended always to follow the safety rules. Wear protective clothes and
special means to avoid injuries to eyes and skins.
Use the welding mask or special protective glasses while working with the welding
machine. Only by viewing through the filter lens on the welding mask your eyes are
secured by your operation.
Prevent the sparks and spatter from harming your body.
-
Under no circumstance allow any part of your body to touch the welder's output bipolarity
(torch and work piece).
Do not operate under water or more humid place.
-
Fumes and gases produced when welding are hazardous to health. Make sure to work in
places where there are exhaust or ventilation facilities to keep fumes or emissions away
from the breathing zone.
Please remember to keep arc rays away from the other nearby people when welding. This
is only due to the interference from arc rays.
There will be high temperature when welding work piece, so please don't directly touch on it
-
No touching on the output connection or any other electrification parts while welding.
-
No touching on the electrification parts after turning on the power. Cut off the power supply
after operation or before leaving the welding site.
No welding in the dangerous site where easily get an electrical shock.
-
No welding for the container loaded inflammable or explosive materials.
-
Safe measures should be adoptted while operating in high place to avoid accident.
-
No entering the welding site for persons not concerned.
-
Welders possible have electromagnetism and frequency interference, so keep away people
with heart pace or the articles which can be interfered by electromagnetism and frequency.
WARNING. The welder voltage is always higher, so the safety precaution should be taken
before repair to avoid accidental shock. Switch off the power supply before each type of
maintenance work. The untrained people are not allowed to make maintenance of the
machine.
- 1 -
Omperator'sanual
www.fubag.ru
Check the connection of input and output cables and the earth (ground) connection, etc.
Maintenance should be conducted by the trained personnel.
The newly installed machine or the welder not in use for some time needs to be checked by
-
multimeter have the right insulation resistance between each winding and the case.
When the welder is used outdoors, it should be kept from rain or long exposure to the sun.
Check is needed from time to time to make sure the welding cable is in good condition if the
-
welding machine is in frequent use. Check at least once each month if the welder is in
regular use. It is necessary to check when the welder is in mobile use.
If the welder is not in use either for a long time or temporarily, it should be kept dry and have
-
good ventilation to free it from moisture, erodible or toxic gas.
- The welder must be installed in the place where it can not be exposed to sun and rain. Also it
must be stored in less humid place with the temperature range at -10 +40 .
Dust removal is needed every year. Check the machine's fasteners, moving-iron, current
-
regulation screws, etc to make sure there are no loose connection problems.
The dust, acid and erodible dirt in the air at the job site can not exceed the amount required
-
by the norm (excluding the emission from the welder).
The welder must be installed in the place where it can not be exposed to sun and rain. Also it
-
must be stored in less humid place with the temperature.
There should be 50 cm space about for the welding machine to have good ventilation.
Make sure that there is no metal-like foreign body to enter the welding machine.
Electrode must be taken down from holder when no welding.
No violent vibration in the welder's surrounding area.
Make sure that there is no interference with the surrounding area at the installation site.
The welder should be installed on the horizontal surface and if it over 15°, there should be
-
added some anti-dump set.
Take measures to prevent wind while operating in the strong wind since the welder is gas
-
shielded. The wind speed is limited below 1 0 m/s, or the wind shield device must be loaded.
,
O
C
Safety Check:
Each item listed below mustbe carefully checked beforeoperation:
Make sure that there isno short circuit connection withwelder's both outputs.
Make sure that there is always sound output and input wire connection instead of exposing it
outside.
Regular check needs to be conducted by the qualified personnel after the welding machine has
been installed over a longperiod or re-operation, whichinvolves as follows:
Check the welding cable tosee if it cancontinue to be usedbefore it is wornout.
-
Replace the welder's inputcable as soon asit is found tobe broken or damaged.
-
Make sure whether there is enough power supply to make the welding machine work properly.
Any power source required to access the welding machine must be installed with some
protective equipments.
Please do not hesitate to contact us for technical assistance whenever you come across the
problems you can notwork out or youmay deem difficult to fix.
--2
Omperator'sanual
2. Technical Specification
www.fubag.ru
Моdel
Input powerV
FrequencyHz
Rated input currentА1920
Rated input capacitancekVA4,24,4
No-load voltageV3230
Welding currentА30~10530~11530~14530~170
Rated duty cycle%2015
Enclosure protectionIP21S21S21S21S
Cooling type
Dimension L W Hcm44х23,8х3644х23,8х3644х23,8х3657х33,6х44,5
Weightkg2323,5
The manufacturer reserves himself the right to make the manual's content or welder's function
change without any preliminary notification of the users.
TS-MIG 150TS-MIG 170TS-MIG 180TS-MIG 190
220
50
2636,6
5,78
3534
1515
Fan cooled
2727,5
3. Description
The wire feed portable MIG/MAG welder adopts box structure: The front panel installs the power
switch, adjustment knobs, overheating indicator, MIG torch, work lead and power cord. If open the
case , you can see the wire feeding system on the left part of machine. The main transformer and
control PCB etc. are installedon the right partof machines.
5
5
1
2
4
1. Power
2. Сurrent
3.
Сurrent Adjusted Knob
ON/OFF
Adjusted switch
--3
1
3
4
4. Wire Speed Adjusted Knob
5. Overload light
6. Voltage Adjusted Knob
5
4
6
Omperator'sanual
www.fubag.ru
If welding with large current for a long time and exceed the duty cycle, the overload lamp will be on
(orange), the machine will stop working until looking to the stated temperature. When the overload
lamp light you must stopwelding and wait about15 minutes, you cancontinue.
4. Environment
Environment to Which the Product Is Subject:
- The surroundingtemperature range: when welding: -10 + 40 С;
During transport or instorage: -25 +55 С
- Relative humidity: when at40 С: ≤50%,20 С: ≤ 90%
ОО
О
when at
О
- The dust, acid and erodible materials in the air can not exceed the amount required by the norm
(apart from the emissions fromthe welding process). Noviolent vibration at thejob site.
- Keep from raining whenit is used outdoor.
-Altitude no more than1,000m.
Requirement for Main Supply:
- The oscillationof the supplied voltage should not exceed ±10% of the rated value.
5. Sign & Pictures Illustration
SIGN
H
IP21
0
X
I
I
U
U
Current
Power
Frequency
Ground
Insulation grade
Protection class
Power source
Rated pen ircuit oltageoc v
Duty cycle
1
2
1
2
Rated nput urrentic
Rated elding urrentwc
Welder’s tructures
Rated nput oltageiv
Rated oadlvoltage
NAME
--4
Omperator'sanual
www.fubag.ru
6. Installation
WARNING! The welder must be well grounded before using. No disassembling of earth cable if
welding is not end, otherwise, it will do harm to human body. When several welders or some other
electrical appliances are using a common grounding device, they must be parallel connection,
series connection is forbidden. The welder's ground cable sectional area should not be less than
that of input power cable.
-
The welder must be loaded in the placewhere are less dust, no chemical, erodible,inflammable or
explosive gas and likeitems around the weldingsite.
-
The welder should be installed in the place where it can not be exposed to sun and rain. Also it
must be stored in lesshumid place with the temperaturerange: -10~40
-
There should be at least50 cm space forthe welding machine.
-
Apparatus to exclude wind andsmoke should be equippedif the inside aerationis not sound.
℃.
7wire. Installation
-
Open the left side board,you can see the wirefeeding system.
-
Install the wire spool tothe wire spool axle, andthen fix.
-
Open the wire feed compaction equipment, let the terminal of wire through the wire guide tube,
drive roller and import the wire guide tube of welding torch, and close the impaction equipment,
adjust the compaction nut ofdrive roller.