WARNING! BEFORE USING THE MACHINE READ THEINSTRUCTION MANUAL
CAREFULLY!
Our generatorsare designed to give safe anddependable service if operated
according to instructions.
Read and understand the anual before operating the generator. Failure to
do so could resultin personal injury orequipment damage.
1. General safety
www.fubag.ru
FUBAG
FUBAGm
WARNING!
WARNING!
WARNING!
WARNING!
Exhaust gas contains poisonouscarbon monoxide.
Never run the generator in an enclosed area. Be sure to provide adequate
ventilation. When installed inventilated protection are tobe observed.
The muffler becomes very hot during operation and remains hot for a while
after stopping the engine.
Be careful not to touch the muffler while it is hot. Let the engine cool before
storing the generator indoors. The engine exhaust system will be heated
during operation andremainhot immediately after stoppingthe engine.
To prevent scalding, pay attention to the warning marks attached to the
generator.
Gasoline is extremely flammable and explosive under certain conditions.
Refuel in a wellventilated area with theengine stopped.
Keep away from cigarette, smoke and sparks when refueling the generator.
Always refuel in awell-ventilated location.
Wipe up spilled gasolineat once.
Connections for standby power to a building's electrical system must be
made bya qualifiedelectrician andmust complywith allapplicable lawsand
electrical codes. Improper connections can allow electrical current from the
generator to back feed into the utility lines. Such back feed may electrocute
utility company workers or others who contact the lines during a power
outage, and when utility power is restored, the generator may explode, burn
or cause fires inthe building's electrical system.
- 1 -
Omperator'sanual
www.fubag.ru
-
WARNING!
-5
Place the generator atleast m away from buildingsor other equipment duringoperation.
-
Operate the generator ona level surface. Ifthe generator is tiled,fuel spillage may result.
-
Know how to stop the generator quickly and understand operation of all the controls.Never permit
anyone to operate thegenerator without proper instructions.
-
Keep children and petsaway from the generatorwhen it is inoperation.
-
Keep away from rotatingparts while the generatoris running.
-
The generator is a potential source of electrical shocks when misused; do not operate with wet
hands.
-
Do not operate thegenerator in rain orsnow and do notlet it get wet.
- The power generator isa mains replacement that generates electrical powerfor supply to a mobile
distribution system.
- The power generator must be operated outdoors within the prescribed voltage, output and rated
speed limits (seetype plate).
- The powergenerator must notbe connected to other electrical supply systems or electric generation
systems (e.g. otherpower generators).
- The powergenerator may notbe used inenvironments where thereis a riskof explosion.
- The powergenerator may notbe used inenvironments where thereis a riskof fire.
- The power generator must be operated in accordance with the conditions set out in the technical
documentation.
- All improper use of the power generator including all uses not described in these instructions will
constitute unauthorized incorrectusage for which the manufacturer is not legally liable.
- Operation inenvironments where there is a risk of explosion and fire.
- Operation inenclosed areas and under direct exposure to rain or snowfall.
- Operation without the requisite safety precautions and connected to existing supply network
systems.
- Spraying withhigh-pressure cleaners or fire extinguishing equipment.
- Failure tocarry out measurements and checks for early detection of defects.
- Know and apply the Prevention of Injury regulations and the safety instructions for the power
generator.
- Understand andbe able to practically implement the technical documentation.
- The operatormust know thefunctions of, andbe able touse, the componentsof the powergenerator.
- The operatormust wear theappropriate personal safetyequipment.
- The labellingon the electricalgenerator must becomplete and maintainedin a readablecondition.
- Constructive changesmay not be carried out on the electrical generator.
- The ratedspeed of themotor has beenset during manufactureand may notbe changed.
- The operatingsafety and correctfunctioning must bechecked before andafter each use.
- No naked flames, lights or spark-emitting appliances may be used within the hazard area of the
power generator.
- Smoking withinthe hazard area of the power generator is strictly forbidden.
- During operation,the power generator must be protected from dirt and foreign matter.
- The powergenerator may onlybe transported whencold.
- The powergenerator may onlybe lifted usingthe carry handlesintended for thispurpose.
- The electricalsafety must bechecked before eachoperational use.
- The appliancemay not becovered. The airintake may notbe blocked orobstructed.
- When starting,the load may not be connected.
- Only certifiedand approved cables may be used for the wired network.
- The powerdrawn may notexceed the maximumrated power.
Always make a pre-operation inspection before you start the engine. You
may prevent an accidentor equipment damage.
- 2 -
Omperator'sanual
www.fubag.ru
- The power generatormay not be operatedwithout the sound absorber.
- The power generatormay not be operatedwithout the air filteror with the airfiltercover open.
- The generator's tankmay not be refilledduring operating.
- The tank maynot be refilled whenthe power generator ishot.
- The power generatormay not be cleanedand serviced when inoperation; when hot.
-Always remove spark plugconnector prior to commencingservicing and repair work.
- The power generatormust be shut downwhen not required forperiods longer than 30days.
- The power generatormust be stored ina dry enclosed room.
2. Safety symbols
1. Precautions that involve your safety
2. Start and run the generator outdoors. Do not run the generator in an
enclosed area, even if doors or windows are open
3. To reduce the risk of serious injury, avoid attempting to touch the hot
.
surface
4. Units should not be operated or stored in wet or damp conditions or on
highly conductive locations such as metal decking and steel work
5. Could not use under the rain
6. Fuel and its vapors are extremely flammable and explosive. Fire or
explosion can cause severe burns or death
7. Ear protection
.
.
.
.
.
.
8. Read carefully and understand operator manual prior to operation of this
product. Follow all warnings and instructions
.
- 3 -
Omperator'sanual
3. Specifications
www.fubag.ru
Generator type
Rated frequency/ IP50 Hz / IP 2350 Hz / IP 2350 Hz / IP 23
Rated voltage230 V 1~230 V 1~230 V 1~
Max. output2,2 kVA5,5 kVA5,5 kVA
Rated output2,0 kW5,0 Kw5,0 Kw
Cos φ
Motor type
Starterelectic starter
MotorHONDA GX160
Tank capacity15 l
Noise level
Relative humidity
Dimension, LxWxH600х450х460 mm
Weight43 kg77 kg81 kg
ModelHS 2500HS 5500HS 5500 ES
recoil starter
Synchro
1-cylinder, 4-stroke, air-cooled
97dB(A)
0-75%
The manufacturer reserves himself the right to make the manual's content or
function change without anypreliminarynotificationof the users.
4. Description
1
HONDA GX390
25 l
690х520х560 mm
power generator
1. SOCKET
2. CIRCUIT BREAKER
3. FUEL GAUGE
4. DIGITAL DISPLAY
5. FUEL TANK CAP
6. ENGINE SWITCH
7. FUEL VALVE
8. CHOKE LEVER
9. RECOIL STARTER
10. OIL DRAIN PLUG
11. OIL FILLER CAP
12. EARTH TERMINAL
BATTERY (only ES)13.
- 4 -
Omperator'sanual
www.fubag.ru
15. AIR CLEANER
16. SPARKPLUG
17. MUFFLER
DIGITAL DISPLAY
A - Digital display
B - AC voltage indicator
C - Frequency indicator
D - Hour indicator
E - Low lubricant alert
F - Select button
- 5 -
Omperator'sanual
www.fubag.ru
5. Pre-Operation checks
Check engine oil
-
Before checking or refilling oil,be sure the generator is
put on a stableand level surface withengine stopped.
-.
Remove oil filler capand check the engineoil level
-
If oil level is below the lower level line, refill with
suitable oil (see table below) to upper level line. Do not
screw in the oilfiller cap when checkingoil level
-.
Change oil if contaminated
.
Single grade
Multi grade
Ambient
temperature
- 6 -
Omperator'sanual
www.fubag.ru
Check engine fuel
WARNING!
-
Do not refuel while smoking or near open flame or
other such potential fire hazards. Otherwise fire
accident may occur
-.
Close fuel cock beforerefueling with fuel
-.
Do not refill tankwhile engine is runningor hot
-
Be careful not to admit dust, dirt, water or other
foreign objects into fuel
-
Wipe off spilt fuel thoroughly before starting
.
engine
-.
Keep open flames away
.
.
-.
Check fuel level atfuel gauge
-
If fuel level is low, refill with unleaded automotive
gasoline
neck
.
Be sure to use the fuel filterscreen on the fuel filter
.
EMPTY
Fuel tank capacity 15l(HS 2500); 25l (HS5500).
Checking components
Check following itemsbeforestarting engine
fuel leakage from fuelhose
-.
bolts and nuts forlooseness
-.
components for damage orbreakage
-.
:
FULL
- 7 -
Omperator'sanual
www.fubag.ru
Checking generator surroundings
WARNING!
Make sure you revieweach warning in orderto prevent fire hazard
- Keep area clearof inflammables or otherhazardous materials.
- Keep generatorat least 3 feet(1 meter) away frombuildings or other structures.
- Only operate generatorin a dry, well ventilated area.Keep exhaust pipe clearof foreign objects.
- Keep generator awayfrom open flame.
- Keep generator ona stable and levelsurface.
- Do not blockgenerator air vents withpaper or other material.
.
6. Operating procedures
Starting
(а).
Set the engine switchto "ON" position
(b).
Open the fuel cock
(с)
Set the choke lever to "CLOSE" (arrow mark). Not
necessary if the engineis warm
.
ОТКРЫТО
ЗАКРЫТО
- 8 -
Omperator'sanual
(d)
Pull the starter handle slowly until resistance is felt.
This is the "Compression" point.Return the handleto its
original position andpullswiftly.
Do not fully pull out the rope. After starting, allow the
starter return to its original position while stillholding the
handle. If the engine fails to start after several attempts,
repeat above procedures with choke lever returned
"OPEN" position
(е)
After the engine started, return the choke lever
gradually to "OPEN" position
.
.
www.fubag.ru
ОPEN
(f).
Warmup the engine withoutload for a fewminutes
Using electric power
(а)
Check the digital display for proper voltage. This generator is thoroughly tested and adjusted in
the factory.
If the generator does not produce the specified voltage, consult your nearest FUBAG generator
.
dealer
(b).
Turnoff the switch(es) ofthe electrical appliance(s) beforeconnecting to the generator
(с).
lnsert the plug(s) ofthe electrical appliance(s) intothe receptacle
WARNING
- Be sure toground the generator ifthe connected electrical equipmentis grounded.
:
- 9 -