Fubag BS 9500 ES, BS 9500D ES User manual

Power station
BS 9500 ES BS 9500 D ES BS 10000 ES BS 10000 D ES
Operator's Manual
Инструкция по эксплуатации
www.fubag.ru
Omperator's anual
WARNING! BEFORE USING THE MACHINE READ THE INSTRUCTION MANUAL CAREFULLY!
Our generators are designed to give safe anddependable service if operated according to instructions. Read and understand the anual before operating the generator . Failure to do so could result in personal injury or equipment damage.
1. General safety
www.fubag.ru
FUBAG
FUBAGm
WARNING!
WARNING!
WARNING!
WARNING!
Exhaust gas contains poisonous carbon monoxide. Never run the generator in an enclosed area. Be sure to provide adequate ventilation. When installed in ventilated protection are to be observed.
The muffler becomes very hot during operation and remains hot for a while after stopping the engine. Be careful not to touch the muffler while it is hot. Let the engine cool before storing the generator indoors. The engine exhaust system will be heated during operation andremain hot immediately after stopping the engine. To prevent scalding, pay attention to the warning marks attached to the generator.
Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped. Keep away from cigarette, smoke and sparks when refueling the generator. Always refuel in a well-ventilated location. Wipe up spilled gasoline at once.
Connections for standby power to a building's electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage, and when utility power is restored, the generator may explode, burn or cause fires in the building's electrical system.
- 1 -
Omperator's anual
www.fubag.ru
-
WARNING!
-5
Place the generator at least m away from buildings or other equipment during operation.
-
Operate the generator on a level surface. If the generator is tiled, fuel spillage may result.
-
Know how to stop the generator quickly and understand operation of all the controls.Never permit
anyone to operate the generator without proper instructions.
-
Keep children and pets away from the generator when it is in operation.
-
Keep away from rotating parts while the generator is running.
-
The generator is a potential source of electrical shocks when misused; do not operate with wet
hands.
-
Do not operate the generator in rain or snow and do not let it get wet.
- The power generator is a mains replacement that generates electrical power for supply to a mobile distribution system.
- The power generator must be operated outdoors within the prescribed voltage, output and rated speed limits (see type plate).
- The power generator must not be connected to other electrical supply systems or electric generation systems (e.g. other power generators).
- The powergenerator may not be used in environments where there is a risk of explosion.
- The powergenerator may not be used in environments where there is a risk of fire.
- The power generator must be operated in accordance with the conditions set out in the technical documentation.
- All improper use of the power generator including all uses not described in these instructions will constitute unauthorized incorrect usage for which the manufacturer is not legally liable.
- Operation in environments where there is a risk of explosion and fire.
- Operation in enclosed areas and under direct exposure to rain or snowfall.
- Operation without the requisite safety precautions and connected to existing supply network systems.
- Spraying with high-pressure cleaners or fire extinguishing equipment.
- Non-compliance with regular servicing requirements.
- Failure to carry out measurements and checks for early detection of defects.
- Know and apply the Prevention of Injury regulations and the safety instructions for the power generator.
- Understand and be able to practically implement the technical documentation.
- The operatormust know the functions of, and be able to use, the components of the power generator.
- The operatormust wear the appropriate personal safety equipment.
- The labellingon the electrical generator must be complete and maintained in a readable condition.
- Constructive changes may not be carried out on the electrical generator.
- The ratedspeed of the motor has been set during manufacture and may not be changed.
- The operating safety and correct functioning must be checked before and after each use.
- No naked flames, lights or spark-emitting appliances may be used within the hazard area of the power generator.
- Smoking within the hazard area of the power generator is strictly forbidden.
- During operation, the power generator must be protected from dirt and foreign matter.
- The powergenerator may only be transported when cold.
- The powergenerator may only be lifted using the carry handles intended for this purpose.
- The electrical safety must be checked before each operational use.
- The appliancemay not be covered. The air intake may not be blocked or obstructed.
- When starting, the load may not be connected.
- Only certified and approved cables may be used for the wired network.
- The powerdrawn may not exceed the maximum rated power.
Always make a pre-operation inspection before you start the engine. You
may prevent an accident or equipment damage.
- 2 -
Omperator's anual
www.fubag.ru
- The power generatormay not be operatedwithout the sound absorber.
- The power generatormay not be operatedwithout the air filteror with the airfilter cover open.
- The generator's tankmay not be refilledduring operating.
- The tank maynot be refilled whenthe power generator ishot.
- The power generatormay not be cleanedand serviced when inoperation; when hot.
-Always remove spark plugconnector prior to commencingservicing and repair work.
- The power generatormust be shut downwhen not required forperiods longer than 30days.
- The power generatormust be stored ina dry enclosed room.
2. Safety symbols
1. Precautions that involve your safety
2. Start and run the generator outdoors. Do not run the generator in an
enclosed area, even if doors or windows are open
3. To reduce the risk of serious injury, avoid attempting to touch the hot
.
surface
4. Units should not be operated or stored in wet or damp conditions or on
highly conductive locations such as metal decking and steel work
5. Could not use under the rain
6. Fuel and its vapors are extremely flammable and explosive. Fire or
explosion can cause severe burns or death
7. Ear protection
.
.
.
.
.
.
8. Read carefully and understand operator manual prior to operation of this
product. Follow all warnings and instructions
.
- 3 -
Omperator's anual
3. Specifications
www.fubag.ru
Generator type Rated frequency/ IP 50 Hz / IP 23 50 Hz / IP 23 50 Hz / IP 23 50 Hz / IP 23 Rated voltage 220 V 220/380 V 220 V 220/380 V Max. output 9,5 kVA 9,5 kVA 10 kVA 9,5 kVA Rated output 8,5 kW 6,8 kW 9,5 kW 7,6 kW Cos y 1 0,8 1 0,8 Motor type Displacement Max. power Tank capacity Noise level Oil tank capacity Weight 158 kg 159 kg 167 kg 168 kg
Model BS 9500 ES BS 9500 D ES BS 10000 ES BS 10000 D ES
2-cylinder, 4-stroke, air-cooled
The manufacturer reserves himself the right to make the manual's content or function change without anypreliminarynotification of the users.
Synchro
678 cubic cm
13,2 kW
25 l
97dB(A)
1,6 l
power generator
4. Description
1.
SOCKET
2.
FUEL GAUGE
.
3
DIGITAL DISPLAY
.
4
FUEL TANK CAP
.
5
ENGINE SWITCH
.
6
FUEL VALVE
.
7
CHOKE LEVER
.
8
EARTH TERMINAL
9.
BATTERY
10. 12
SOCKET V
TERMINAL
11.
- 4 -
Omperator's anual
DIGITAL DISPLAY
www.fubag.ru
12.
AIR CLEANER
13.
MUFFLER
14
OIL FILLER CAP
.
15
OIL DRAIN PLUG
.
A - Digital display B - AC voltage indicator C - Frequency indicator D - Hour indicator E - Low lubricant alert F - Select button
“W”
PHASE
BS 9500 ES BS 10000 ES
“”N
ZERO
TERMINAL
BS 9500 D ES BS 10000 D ES
- 5 -
“”U
PHASE A
“”V
PHASE B
“W”
PHASE C
“”N
ZERO
Omperator's anual
www.fubag.ru
5. Pre-Operation checks
Check engine oil
-
Before checking or refilling oil, be sure the generator is
put on a stable and level surface with engine stopped.
-.
Remove oil filler cap and check the engine oil level
-
If oil level is below the lower level line, refill with suitable oil (see table below) to upper level line. Do not screw in the oil filler cap when checking oil level
-.
Change oil if contaminated
.
In the table oil types which can be used are provided below. Don't use oil for 2-stroke engines.
UPPER
LEVEL
LOWER
LEVEL
Single grade
Multi grade
Ambient
temperature
- 6 -
Omperator's anual
www.fubag.ru
Check engine fuel
WARNING!
-
Do not refuel while smoking or near open flame or other such potential fire hazards. Otherwise fire accident may occur
-.
Close fuel cock before refueling with fuel
-.
Do not refill tank while engine is running or hot
-
Be careful not to admit dust, dirt, water or other
foreign objects into fuel
-
Wipe off spilt fuel thoroughly before starting
.
engine
-.
Keep open flames away
.
.
-.
Check fuel level at fuel gauge
-
If fuel level is low, refill with unleaded automotive
gasoline
­neck
.
Be sure to use the fuel filter screen on the fuel filter
.
EMPTY
Fuel tank capacity 25l.
Checking components
Check following itemsbefore starting engine
fuel leakage from fuel hose
-.
bolts and nuts for looseness
-.
components for damage or breakage
-.
:
Max level
FULL
- 7 -
Omperator's anual
www.fubag.ru
Checking generator surroundings
WARNING!
Make sure you review each warning in order to prevent fire hazard
- Keep area clear of inflammables or other hazardous materials.
- Keep generatorat least 3 feet(1 meter) away frombuildings or other structures.
- Only operate generator in a dry, well ventilated area. Keep exhaust pipe clear of foreign objects.
- Keep generator away from open flame.
- Keep generator on a stable and level surface.
- Do not block generator air vents with paper or other material.
.
6. Operating procedures
Starting
- Check all consumers are disconnected
- Open the fuel crane (see drawing)
- Check that the protective switch was in situation OFF
OFF
- Transfer the air gateto situation It is CLOS (only at the cold engine)
- Turn the start switch to “start” position.
fter starting the engine, release the “start” switch
-A immediately,the switch will return back to “run” position.
After warming up the engine, push the choke button to
­“open” position.
Do not let the switch stay in “start” position over 5 seconds, or the starter may be damaged. If the engine can not be started at first time, start the engine again at an interval of over 10 seconds. If the starter speed degrades after using it a period of time, it means charging the battery is necessary.
- 8 -
CLOSE
ON
OPEN
Omperator's anual
www.fubag.ru
Using electric power
- Check the CIRCUITBREAKER is "ON". Ifthe breaker is "OFF",set the breaker "ON".
- Check the digital display for proper voltage.This generator is thoroughly tested and adjusted in the factory. If the generator does not produce the specified voltage, consult your nearest FUBAG generator dealer
.
- Turn off the switch(es) of the electrical appliance(s) before connecting to the generator
- lnsert the plug(s) of the electrical appliance(s) into the receptacle
.
.
WARNING
:
1. Be sure to ground the generator if the connected electrical equipment is grounded.
2. /
Connect to power supply
NOTE
:
- When the circuit breaker or no-fuse breaker turns off during operation, the generator is overloaded or the appliance is defective.
- Stop the generator immediately, check the appliance and /or generator for overloading or defect and repair as necessary
.
Stoppin the generator
- Turn off the power switch of the electric equipment or unplug the cord from receptacle of the generator
.
- Allow the engineabout 3 minutes to cool down atno-load before stopping
- Set the engine switch to "OFF" position
- Close (stop) the fuel cock
.
.
.
The oil sensor detects the fall in oil in the crankcase and automatically stops the engine when the oil level falls down below the safety limit
When engine has stopped automatically, check the oil
­level
.
If the engine does not start by usual starting
­procedures, check the oil level
.
.
work
stopped
Working conditions
AMBIENT CONDITIONS
Set up height about sea-level < 100 [m] 1 % 100 [m] Temperature < 27 [°C] 4 % 10 [°C] Relative humidity < 60 [%]
Description Value Unit
Reduction in output Each additional Unit
REDUCED OUTPUT
- 9 -
Loading...