WARNING!BEFORE USING THEFANHEATER READ THE INSTRUCTION
MANUAL CAREFULLY!FOR QUALIFIED AND SPECIALLY TRAINEDPERSONS
ONLYAFTER PROPER READINGOF THIS MANUALISALLOWED TO USEAND TO
MAINTAIN THIS DEVICE.
The detailed description, safety rules and all required information necessary for proper operation
and maintenance of FUBAG fan heater are provided below. Keep this instruction manual by
charger and refer to it by any doubts concerning safety operation, maintenance storage and
handling of FUBAGdevice.
1. Safety perationo
- The combustion of propane will consume a lot of oxygen (of butane even more). An inlet-air
opening to outside of min. 24 cm /kw is strongly recommended. The room space being heated
could be rate as 100 W/m based onthe gross heat input and in no case less than 250 m . Never
3
3 3
use the heaterin an enclosedroom.
- Never blockair inlet (rear)or air outlet(front) of theheater.
- Be sure let the motor fan works at least 30 seconds before igniting the heater and after the
heating.
- Do not cover the fan heater.
- Do not place the fan heater immediately under a wall socket.
- Do not connect the fan heater using an on/off timer or other equipment which can
automatically switch the device on.
- The fan heater must not be placed in rooms where flammable liquids or gases are used or
stored.
- If an extension cord is used, it must be as short as possible and always be fully extended.
- Children should be supervised to ensure that they do not play with the appliance. The
appliance in not intended for use by person (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge. If the appliance is
damaged, do not use it any more.
- Do not place the appliance on moving vehicles or some where easy to be tipped over.
- Use the appliance in places with good air ventilation, do not position it near a wall or corner.
- It is recommended that a separate circuit serving only this appliance be provided keep the
power cord far enough from the hot air outlet.
- If the supply cord is damaged, it must be replaced by the manufacturer or service agent or
a similarly qualified person in order to avoid a hazard.
- You must not connect other appliances to the same mains socket as the fan heater.
- Failure to comply with the precautions and instructions provided with this heater, can result
in death, serious bodily injury and property loss or damage from hazards of fire, explosion,
burn, asphyxiation, carbon monoxide poisoning, and/or electrical shock.
- Only persons who can understand and follow the instructions should use or service this
heater.
- If you need assistance or heater information such as instructions manual, labels, etc.
Please contact the manufacturer.
- 1 -
Omperator's anual
www.fubag.ru
- Fire, burn, inhalation and explosion hazard. Keep solid combustibles, such as building materials,
paper or cardboard, a safe distance away from the heater. Never use the heater in spaces which do
or may contain volatile or airborne combustibles, or products such as gasoline, solvents, paint
thinner,dust particles orunknown chemicals.
- Maximum inletgas supply pressureis 16 bar
- Propane and butane belong to odorless fuel gases. Normally gas suppliers will add an odormaking agent to help you to detect gas leakage. However, the odor added can fade. Fuel gases
maybe present eventhough no odorexists.
- To check the leakage of propane/butane please use a professional gas-leakage detector or simply
with soap watersolution.
- Propane and butane are heavier than air. If there being leakage, it sinks to the lowest possible
level, collecting there with the surrounding air, forming a potentially explosivemixture. Therefore itis
prohibited to usethe heater inbasement or belowground level.
Install the heatersuch that itis not directlyexposed to waterspray or rain.-
2. Technicalspecifications
Power consumption, W 28 28 75 75 75 75 180 180
Current consumption, A 0,22 0,22 0,52 0,52 0,52 0,52 0,78 0,78
Max air flow, m.cube/hour 500 500 1000 1000 1000 1000 2000 2000
Nominal heat output, kW 11 16,7 31 31 31 40 62 79
Nominal gas consumption, kg/hour 0,8 1,21 2,27 2,27 2,27 2,9 4,51 5,76
Nominal heat output, kcal/hour 9462 14352 26914 26914 26914 34758 53442 68122
Nominal gas pressure, bar 0,3 0,5 1,5 1,5 1,5 1,5 1,5 1,5
Protection class IP44 IP44 IP44 IP44 IP44 IP44 IP44 IP44
Dimensions, mm 340x210x315 350x210x315 645x375x510 615x270x460 645x375x510 745x375x510 845x375x510 845x375x510
Weight, kg 4,2 4,5 11,8 8,7 13,7 12,6 17,7 17,7
Item/Model BRISE 10 BRISE 15 BRISE 30 BRISE 30 mini BRISE 30 AT BRISE 40 BRISE 60 AT BRISE 80 AT
The manufacturer reserves himself the right to make the manual's content or function change
without any preliminarynotification of the users.
3. Connection
-
Check the heaterthoroughly for damage.Do not operatea damaged heater.
-
Be sure the heating area is enough ventilated, free of moisture and dust, far away from any
combustible material.
-
Put the gas cylinder (detail specification contact your gas dealer) stably backward the heater.
Never put thegas cylinder inthe front ofheater.
-
Check firstly the out let pressure of the gas regulator and gas hoseaccording to the specification on
name-plate. Gas hoseshould be inits natural formwithout bending.
-
Screw-fasten the gashose with regulatorto the cylindervalve. Ensure thetightness.
-
Screw-fasten the gashose to thegas inlet onthe heater. Ensure thetightness.
-
Plug in thepower cord toa wall socket.
-
Open the gasvalve on thecylinder slowly. Be sure there is no gas leakage.
--2
Omperator's anual
4. Operating mode
www.fubag.ru
For BRISE 10, BRISE 15 BRISE 30 (mini), BRISE 40
- Press the ON-OFF switch. Let the motor fan runs at least 30 seconds to check if the fan works
properly and/or to purge left fuel gas of the last use.
- Open the gas valve on the cylinder slowly. Be sure there is no gas leakage.
- Push in and hold the gas control valve button. Push piezo-ignition button repeatedly until the burner
lights.
- After the burner lights keep the gas valve button depressed for at least 5 seconds then release and
the heater will continue to operate.
For BRISE 30 AT, AT, AT
- Press the ON-OFF switch. The heater will then run automatically.
- Adjust the room temperaturecontrol knob to set the temperature as your wish.
1
2
,
BRISE 60 BRISE 80
BRISE 10,15
3
BRISE 30(mini), 40
1.
ON-OFF switch
2.
as control valve button
G
3.
as valve
G
4.
iezo-ignition button
P
Handle
5.
Cable
6.
Warning lamp
7.
4
BRISE 30 AT, 60 AT, 80 AT
2
3
1
4
5
6
7
1
3
5
5
- 3 -