FSR FL-700 User Manual

METAL PRODUCT GROUP
FL-700 FL-710
FSR
LIT1021A
The FL-700/710 fl oor box is designed for conference rooms, auditoriums, classrooms, etc. where it may be nec- essary to pass cables thru the box without interfering with the various connectors. This simplifi es installation of wiring when a group of boxes must be connected in series. The pass-thru route is front-to-back. The FL-700/710 water-tight carpet-trim cover is used with carpeted fl oors over concrete. This fl oor box provides a practical and safe solution for easy access to cables and connector plates. The lift-off section of the cover allows full access to internal cables and connector plates while a smaller, hinged trapdoor fl ips back to create a cable exit. All cables can be stored within the box when they are not in use, allowing unencumbered travel across the fl oor in the area of the FL-700/710.
Before proceeding with the installation please take time to review the photos on the opposite side of this page.
Step 1
Locate the box, complete with the temporary cover, on the fl oor structure. Remove the temporary cover, spacer angles, and insert plate. Connect all conduits as required. Reinstall the temporary cover, spacer angles and insert plate. Use the leveling feet to position the box such that the top of temporary cover is fl ush with the surface of the concrete fl oor.
INSTALLATION INSTRUCTIONS
11/08
Step 2
After the concrete fl oor is cured, remove the temporary cover, spacer angles, and insert plate. Install all the cables and connector plates as required. Reinstall the insert plate, spacer angles, and the temporary cover.
Step 3
Prepare to install the fi nish cover . Remove the temporary cover and spacer angles and discard them. Locate and carefully seperate the outer and inner door ring gaskets.
Step 4
Apply the outer gasket to the bottom of the outer door trim ring, covering the trim screws, and ending up with an 1/8" overhang on the outer edges. Do not stretch the gasket while installing. The gasket should just touch the edge of the attachment screw holes.
FSR Inc 244 Bergen Boulevard, West Paterson, NJ 07424 Phone: 973-785-4347 Fax: 973-785-3318 Web: www.fsrinc.com E-Mail: sales@fsrinc.com
Step 5
Place outer door trim ring on top of the mounting plate insert and install all the screws. Use an alternate corner pattern to tighten.
Step 6
Install the inner gasket over mounting screws. Do not stretch the gaskets while installing.
Step 7
Install the chain between the insert and the inner cover.
Step 8
Place the inner cover on the housing and press fi rmly on the center to form the new gasket. Turn the fourquar- ter-turn cover screws clockwise to secure the cover.
Step 9 Make sure all of the screws are completely seated to avoid a"trip" hazard.
Loading...