FSR FL-600P User Manual

GANG DIVIDER ASSEMBLY
DIVIDER HOLDER MUST TO DIVIDERS, IN ORDER TO PROPERLY ASSEMBLE BOX INTERIOR.
BE ORIENTED AS SHOWN WHEN ATTACHING
FSR
FL-600P INSTALLATION INSTRUC TIONS
244 Bergen Boulevard, Woodland Park, NJ 07424, Phone: 973.785.4347 - Fax: 973.785.4207
4" BOX DIVIDER 5"-6" BOX DIVIDER 7"-12" BOX DIVIDER
DIVIDER
DIVIDER HOLDER
(2) #8-32 x .25 LG
PAN HEAD
SCREW
* DIVIDER ASSEMBLY FOR 5" & 7" BOXES
POSITION DIVIDER ASSEMBLY IN BOX BEFORE INSTALLING GANG PLATE ASSEMBLY. SECURE DIVIDER ASSEMBLY TO GANG PLATE ASSEMBLY WITH SCREWS AS NOTED.
GANG
MOUNTING
PLATE
DIVIDER
(2) #8-32 x .25 LG
PAN HEAD
SCREW
DIVIDER HOLDER
GANG PLATE ASSEMBLY
LARGE GAP FILLER*
DIVIDER
(2) #8-32 x .25 LG
PAN HEAD
SCREW
DIVIDER HOLDER
(4) #8-32 x .375 LG SELF TAPPING PAN HEAD SCREW
BOX INSTALLATION - ST EP 1
LOCATE AND POSITION BOX IN ACCORDANCE WITH FLOOR PLANS. TOP SURFACE OF TEMPORARY COVER MUST TO MATCH THE HEIGHT OF THE FINISHED FLOOR - ie STONE, WOOD OR CONCRETE - SEE TYPICAL INSTALLATION HEIGHTS. LEVEL AND ANCHOR BOX AS REQUIRED. USE SCREWS, NAILS, OR WIRE TO PREVENT BOX FROM FLOATING DURING POUR. REMOVE AND RETAIN TEMPORARY COVER AND SCREWS. ROUTE CONDUITS TO BOX AS REQUIRED. GANG BRACKET
SCREWS MUST SCREW VOIDS AFTER POUR. PLACE THIS INSTALLATION GUIDE
BACK INTO BOX, ALONG WITH ALL SUPPLIED ITEMS, AND REINSTALL TEMPORARY COVER.
TEMPORARY
COVER
BE IN PLACE AND BOTTOMED TO ENSURE
(8) #6-32 FLAT HEAD SCREW
BE SET
BOX INSTALLATION - STEP 2
SCREED TO TOP OF BOX SURFACE FOR 3/16" THICK CARPET/FLOORING OR SPECIFIC HEIGHT TO ALLOW FOR THICKER FINISHED FLOOR MATERIAL. HAND TROWELING RECOMMENDED NEAR BOX EDGES. BOX HAS NO CONCRETE POUR.
HEIGHT ADJUSTMENT AFTER
CONCRETE SURFACE OR TOP OF FINISHED FLOOR MATERIAL
SMALL GAP
FILLER*
(2) #8-32 x .25 LG FLAT HEAD SCREW
DIVIDER ASSEMBLY
* GAP FILLERS ARE OPTIONAL, PER DESIRED CONFIGURATION (SEE PREVIOUS PAGE), AND ARE INSTALLED SIMILARLY TO DIVIDER ASSEMBLIES.
INSTALLING ELECTRONIC COMPONENTS
PULL WIRES AND CABLES TO BOX AS NECCESSARY (REMOVAL OF GANG MOUNTING BRACKETS MAY BE REQUIRED). TERMINATE WIRES AND CABLES TO ELECTRONIC COMPONENTS, AND INSTALL ELECTRONIC COMPONENTS ONTO GANG MOUNTING BRACKETS. REINSTALL TEMPORARY COVER IF FINISHED COVER IS TO BE INSTALLED AT A LATER DATE.
GANG
MOUNTING
BRACKET
INSTALLED ELECTRONIC COMPONENT
(4) LEVELING BOLT
TYPICAL INSTALLATION HEIGHTS
CARPET
CARPET OVER CONCRETE (COVER WITH BEVELED EDGING)
SCREED FLUSH
TEMPORARY COVER
FLOOR BOX
CONCRETE
TILE OR THIN WOOD LAMINATE OVER CONCRETE (COVER WITH SQUARE EDGING)
TILE OR THIN WOOD LAMINATE
SCREED FLUSH
FLOOR BOX
CONCRETE
GROUT/THINSET
TEMPORARY COVER
CONCRETE
CONCRETE
EDGING
FINISH COVER
FLOOR BOX
EDGING
FINISH COVER
FLOOR BOX
43202 LIT1334
TYPICAL INSTALLATION HEIGHTS
WOOD WITH OR WITHOUT SLEEPER SYSTEM OVER CONCRETE (COVER WITH EDGING)
H (BASED ON ASSEMBLY THICKNESS) =
TH (TOTAL ASSEMBLY HEIGHT) - E (EDGING HEIGHT)
TEMPORARY COVER
H
WOOD
TH
EDGING
E
H
VERIFY PER SPECIFICATION OR ORDER
GANG MOUNTING BRACKET CONFIGURATION
PER CUSTOMER SPECIFICATIONS, CONFIGURE GANG MOUNTING BRACKETS AS SHOWN BELOW AND REASSEMBLE INTO BOX.
5 OR 6 GANG MOUNTING PLATE
SMALL GAP FILLER
DIVIDER HOLDER
LARGE GAP FILLER
6 GANG SIDE
FINISH COVER
CONCRETE
FLOOR BOX
SLEEPER
SYSTEM
(IF USED)
FLOOR BOX
CONCRETE
WOOD WITH OR WITHOUT SLEEPER SYSTEM OVER CONCRETE (COVER WITHOUT EDGING)
H = ASSEMBLY THICKNESS
TEMPORARY COVER
H
CONCRETE
FLOOR BOX
SLEEPER
SYSTEM
(IF USED)
WOOD
H
CONCRETE
FINISH COVER
FLOOR BOX
VINYL FLOORING OVER CONCRETE (COVER WITHOUT EDGING)
TEMPORARY COVER
VINYL FLOORING
FINISH COVER
OPTIONAL DIVIDER
5 GANG SIDE
"5 GANG SIDE" MOUNTING BRACKET CONFIGURATIONS
1G 1G 2G 1G 1G 3G 1G 3G 1G 1G 4G
2G 2G 2G 3G 4G 1G 5G
"6 GANG SIDE" MOUNTING BRACKET CONFIGURATIONS
FLOOR BOX
CONCRETE
CONCRETE
CENTER DIVIDER CONFIGURATION (NOT APPLICABLE ON 4" BOX)
SET ASIDE TEMPORARY COVER AND SCREWS FOR POSSIBLE RE-INSTALLATION. REMOVE AND RETAIN GANG MOUNTING BRACKETS AND SCREWS TO CONFIGURE CENTER DIVIDERS.
REMOVABLE SMALL CENTER DIVIDER
REMOVABLE LARGE CENTER DIVIDER
POSSIBLE GANG DIVIDER LOCATION
REMOVABLE SMALL CENTER DIVIDER
REMOVABLE LARGE CENTER DIVIDER
"6 GANG SIDE"
"5 GANG SIDE"
FLOOR BOX
1G 3G 1G 3G
2G 2G 2G 2G
3G 2G 4G 1G 6G
1G 4G
2G 2G
2G 3G 3G 1G