FSR CB-224, CB-224S User Manual

CEILING TILE INSTRUCTIONS
8.
INSTALL 19-3/8" x 22-3/4" DROP CEILING MATERIAL (SUPPLIED BY CUSTOMER) INTO DOOR. BEND CAPTURE TABS OVER CEILING PANEL TO HOLD IN PLACE.
CB-224/224S INSTALLATION INSTRUCTIONS
FSR
1.
INSTALL CB-224/S TO A STRUCTURAL CEILING ABLE TO SUPPORT FIVE TIMES THE NOTED GROSS WEIGHT. USE APPROPRIATE MOUNTING METHODS BASED ON LOCAL BUILDING CODES. INSTALL SAFETY CABLE AS REQUIRED BY LOCAL BUILDING CODES. ROUTE CONDUITS TO BOX AS REQUIRED.
NOTE: MAXIMUM GROSS WEIGHT - 125 LBS
244 Bergen Boulevard, Woodland Park, NJ 07424, Phone: 973.785.4347 - Fax: 973.785.4207
STRUCTURAL MEMBER
19-3/8" x 22-3/4" DROP
CEILING PANEL MATERIAL
(SUPPLIED BY CUSTOMER)
NOTE: THREADED ROD IS THE RECOMMENDED CEILING BOX MOUNTING SUSPENSION (SHOWN), TO MINIMIZE FIXTURE TILTING DUE TO THE WEIGHT OF ANY SUSPENDED EQUIPMENT.
14 GA. STEEL TIE WIRE MAY BE USED
(SUPPLIED BY CUSTOMER OR USE FSR KIT)
AT 70,000 PSI TENSILE STRENGTH OR
BETTER AS REQUIRED BY BUILDING CODES.
NOTE: WIRES SUPPORT CEILING
BOX, AND ARE NOT
THREADED ROD OR CABLE TO
BE PLUMB WITH CEILING AND FLOOR
AVAILABLE KITS (SOLD SEPARATELY): CB-MNT1 - CABLE INSTALLATION KIT CB-THRD - THREADED ROD INSTALLATION KIT
SAFETY CABLES
2.
TO INSTALL AC MAIN POWER INTO THE UNIT, REMOVE THE AC ACCESS PLATE BY REMOVING (4) #8-32 SCREWS, AS SHOWN. WIRING MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN ONLY. WIRING MUST BE DONE IN ACCORDANCE WITH ALL NEC AND OTHER APPLICABLE CODES. RE-INSTALL AC ACCESS PLATE AFTER AC WIRING IS COMPLETE.
ALL MOUNTING HARDWARE SUPPLIED BY CUSTOMER
STRUCTURAL CHANNEL
ROUTE CONDUIT (SUPPLIED BY CUSTOMER) TO KNOCKOUTS AS REQUIRED
BRACKET - FSR'S THREADED ROD INSTALLATION KIT (HARDWARE SUPPLIED BY CUSTOMER)
(4) CAPTURE
TAB
LOOSEN SCREWS TO OPEN DOOR
FSR Inc.
244 Bergen Boulevard, Woodland Park, NJ 07424 Phone: 973.785.4347 - Fax: 973.785.4207 Web: www.fsrinc.com - E-mail: sales@fsrinc.com
(4) #8-32 x 1/4"-LONG PAN HEAD SCREW
AC ACCESS
AC POWER INPUT WIRING MUST BE
PERFORMED BY A QUALIFIED
ELECTRICIAN ONLY
43972 LIT1364A
PLATE
3.
IF NOT INSTALLING FAN KIT, PROCEED TO STEP 5. IF INSTALLING FAN KIT, REMOVE CEILING BOX DOOR. LOOSEN SCREWS TO OPEN DOOR. (a) PUSH DOOR UP TOWARDS CEILING AND (b) PUSH TOWARDS DROP-DOWN RACK-MOUNT CARRIAGE - REVERSE PROCEDURE TO INSTALL. DISCONNECT SAFETY CABLE TO COMPLETELY REMOVE DOOR.
DROP-DOWN RACK-MOUNT CARRIAGE
MOUNTING ELECTRONICS INSTRUCTIONS
5.
PULL DOWN DROP-DOWN RACK-MOUNT CARRIAGE TO MOUNT ELECTRONICS. (a) PUSH LOCK ARM AWAY FROM POLE MOUNT AND (b) AND PULL DOWN ON CHAIN. ONCE THE DROP-DOWN CARRIAGE IS PULLED FULLY DOWN (c) AGAIN PUSH THE LOCK ARM AWAY FROM POLE MOUNT TO LOCK CARRIAGE IN THE 'DOWN' POSITION. REVERSE PROCEDURE TO RETRACT CARRIAGE BACK INTO CEILING BOX.
NOTE: MAXIMUM LOAD INSIDE CARRIAGE - 25 LBS
LOCK ARM
a
DROP-DOWN RACK-MOUNT CARRIAGE
b
a
LOOSEN SCREWS TO OPEN DOOR
4.
REMOVE #8-32 SCREW AS SHOWN, AND REMOVE OUTLET GRILL. SUPPORT OUTLET GRILL WHILE REMOVING SCREW. INSTALL FAN KIT PER INSTRUCTIONS. RE-INSTALL OUTLET GRILL AND CEILING BOX DOOR BACK INTO CEILING BOX BY REVERSING THEIR REMOVAL STEPS.
PULL CHAIN
b
6.
INSTALL WIRE BUNDLE INLET, WIRE INLET FOAM, AND WIRE INLET COVER TO SIDES OF BOX. REMOVE THE FOAM BLOCKS NECESSARY FOR THE WIRE BUNDLE EXITING THE BOX. PULL WIRES TO CEILING BOX THRU WIRE INLET OR CONDUIT AS REQUIRED.
(2) WIRE
INLET
COVER
REMOVABLE
(2) WIRE
INLET FOAM
FOAM BLOCKS
(2) WIRE BUNDLE INLET
c
7.
INSTALL 1RU TO 4RU x 19" EIA RACK-SIZED ELECTRONICS. MAKE ELECTRICAL CONNECTIONS AS REQUIRED. RACK MOUNT BRACKETS CAN BE RE-POSITIONED TO ALTERNATE HOLES, OR ADDITIONAL BRACKETS MAY BE PURCHASED (CB-224RKRL).
NOTE: MAXIMUM LOAD INSIDE CARRIAGE - 25 LBS
ALTERNATE RACK MOUNT BRACKET HOLES
#8-32 x 1/4"-LONG
PAN HEAD SCREW
OUTLET GRILL
(2) #8-32 x 1/4-LONG
PAN HEAD SCREW
(4) RACK MOUNT BRACKET INCLUDED
VIEW SHOWING
ALTERNATE
BRACKET
HOLES USED
ALTERNATE/ADDITIONAL RACK MOUNT BRACKET HOLES ON OPPOSITE SIDE OF CARRIAGE