Frymaster FMPH455 Installation Manual

Pro H55-Series Gas Fryers
Installation and Operation Manual
Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633
www.frymaster.com E-mail: service@frymaster.com
*8195991A*
OCTOBER 2011
NOTICE
IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS MANITOWOC FOODSERVICE EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
NOTICE This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster Factory Authorized Servicer (FAS) or other qualified professional should perform installation, maintenance, and repairs. Installation, maintenance, or repairs by unqualified personnel may void the manufacturer’s warranty. See Chapter 1 of this manual for definitions of qualified personnel.
NOTICE This equipment must be installed in accordance with the appropriate national and local codes of the country and/or region in which the appliance is installed. See NATIONAL CODE REQUIREMENTS in Chapter 2 of this manual for specifics.
NOTICE TO U.S. CUSTOMERS This equipment is to be installed in compliance with the basic plumbing code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration.
NOTICE Drawings and photos used in this manual are intended to illustrate operational, cleaning and technical procedures and may not conform to onsite management operational procedures.
NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
U.S.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.
CANADA
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.
DANGER Improper installation, adjustment, maintenance or service, and unauthorized alterations or modifications can cause property damage, injury, or death. Read the installation, operating, and service instructions thoroughly before installing or servicing this equipment. Only qualified service personnel may convert this appliance to use a gas other than that for which it was originally configured.
ii
DANGER No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633.
DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all times when the fryer is in use.
DANGER The front ledge of the fryer is not a step! Do not stand on the fryer. Serious injury can result from slips or contact with the hot oil.
DANGER Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance.
DANGER Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak must be posted in a prominent location. This information can be obtained from the local gas company or gas supplier.
DANGER This product contains chemicals known to the state of California to cause cancer and/or birth defects or other reproductive harm.
Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.
DANGER The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container at the end of frying operations each day. Some food particles can spontaneously combust if left soaking in certain shortening material.
WARNING Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is present to seal the joint between the fry vessels. Banging fry baskets on the strip to dislodge shortening will distort the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for cleaning.
NOTICE The Commonwealth of Massachusetts requires any and all gas products to be installed by a licensed plumber or pipe fitter.
iii
PRO H55 SERIES GAS FRYER
INSTALLATION & OPERATION MANUAL
TABLE OF CONTENTS
CHAPTER 1: General Information
1.1 Applicability and Validity.................................................................................................1-1
1.2 Parts Ordering and Service Information............................................................................ 1-1
1.3 Safety Information............................................................................................................. 1-2
1.4 European Community (CE) Specific Information.............................................................1-2
1.5 Equipment Description......................................................................................................1-3
1.6 Installation, Operating, and Service Personnel ................................................................. 1-3
1.7 Definitions.........................................................................................................................1-3
1.8 Shipping Damage Claim Procedure.................................................................................. 1-4
CHAPTER 2: Installation Instructions
2.1 General Installation Requirements.................................................................................... 2-1
2.2 Caster/Leg Installation ...................................................................................................... 2-3
2.3 Pre-Connection Preparations.............................................................................................2-3
2.4 Connection to Gas Line.....................................................................................................2-5
2.5 Converting to Another Gas Type ......................................................................................2-8
CHAPTER 3: Operating Instructions
3.1 Controller Operation and Programming............................................................................3-1
3.2 Start-Up Procedure............................................................................................................3-1
3.3 Boiling Out the Frypot ......................................................................................................3-3
3.4 Shutting the Fryer Down................................................................................................... 3-3
CHAPTER 4: Filtration Instructions
4.1 Draining and Manual Filtering.......................................................................................... 4-1
4.2 Preparing the Built-In Filtration System for Use ..............................................................4-2
4.3 Operation of the Filter.......................................................................................................4-5
4.4 Disassembly and Reassembly of the Magnasol Filter.......................................................4-8
4.5 Draining and Disposing of Waste Oil ...............................................................................4-9
4.6 Using the Optional Rear-Discharge Oil Disposal ...........................................................4-10
CHAPTER 5: Preventive Maintenance
5.1 Fryer Preventive Maintenance Checks and Service..........................................................5-1
Daily Checks and Service..................................................................................................5-1
Weekly Checks and Service..............................................................................................5-1
Monthly Checks and Service............................................................................................. 5-3
Quarterly Checks and Service........................................................................................... 5-4
Semi-Annual Checks and Service..................................................................................... 5-6
5.2 Built-In Filtration System Preventive Maintenance Checks and Service .........................5-6
5.3 Annual/Periodic System Inspection ..................................................................................5-7
CHAPTER 6: Operator Troubleshooting
6.1 Introduction....................................................................................................................... 6-1
6.2 Troubleshooting Fryers with Computer Magic III.5, Basket Lift Timer, or Digital
Controller...........................................................................................................................6-2
6.3 Troubleshooting Fryers with Solid State (Analog) Controller.......................................... 6-4
6.4 Troubleshooting the Built-In Filtration System ................................................................6-6
6.5 Troubleshooting the Basket Lift........................................................................................6-8
iv
PRO H55 SERIES GAS FRYER
CHAPTER 1: GENERAL INFORMATION
1.1 Applicability and Validity
The Pro H55 Series Gas Fryer has been approved by the European Union for sale and installa­tion in the following EU countries: AT, BE, DE, DK, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT and SE.
This manual is applicable to and valid for all Pro H55 Series Gas Fryers sold in English­speaking countries, including those in the European Union. Where conflicts exist between in­structions and information in this manual and local or national codes of the country in which the equipment is installed, installation and operation shall comply with those codes.
This appliance is only for professional use and shall be used by qualified personnel only, as defined in Section 1.7.
1.2 Parts Ordering and Service Information
In order to assist you quickly, the Frymaster Factory Authorized Servicer (FAS) or Service Depart­ment representative requires certain information about your equipment. Most of this information is printed on a data plate affixed to the inside of the fryer door. Part numbers are found in the Installa­tion, Operation, Service, and Parts Manual. Parts orders may be placed directly with your local FAS or distributor. A list of Frymaster Factory Authorized Servicers (FAS’s) is located on the Frymaster website at www.frymaster.com. If you do not have access to this list, contact the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711 or by e-mail: service@frymaster.com.
When ordering parts, the following information is required:
Model Number: Serial Number: Type of Gas or Voltage: Item Part Number: Quantity Needed:
Service information may be obtained by contacting your local FAS/Distributor. Service may also be obtained by calling the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711 or by e-mail: service@frymaster.com. When requesting service, please have the following information ready:
Model Number: Serial Number: Type of Gas:
In addition to the model number, serial number, and type of gas, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your problem.
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.
1-1
1.3 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones that follow.
CAUTION
CAUTION boxes contain information about actions or conditions that may cause or result
in a malfunction of your system.
WARNING
WARNING boxes contain information about actions or conditions that may cause or result
in damage to your system, and which may cause your system to malfunction.
DANGER
DANGER boxes contain information about actions or conditions that may cause or result
in injury to personnel, and which may cause damage to your system and/or cause your
system to malfunction.
Your fryer is equipped with automatic safety features:
1. High temperature detection shuts off gas to the burner assembly should the controlling
thermostat fail.
2. An optional safety switch built into the drain valve prevents burner ignition with the drain valve
even partially open.
1.4 European Community (CE) Specific Information
The European Community (CE) has established certain specific standards regarding equipment of this type. Whenever a conflict exists between CE and non-CE standards, the information or instructions concerned are identified by means of shadowed boxes similar to the one below.
Non-CE Standard
for Inco ming Gas Pre ssur es
Type Minimum Maximum
6" W.C. 14" W.C.
Na tu r a l 1.4 9 k P a 3.49 kP a
14.68 mbar 34.72 mbar 11" W .C. 14" W.C.
LP 2.74 kPa 3.49 kPa
27.28 mbar 34.84 mbar
1-2
1.5 Equipment Description
Pro H55 Series high-efficiency gas fryers employ a unique infrared burner system that uses up to 43% less energy to cook the same volume as conventional open-burner fryers. Models in this series include PH55, FMPH55, and FPPH55 variants. PH55 models have no built-in filtration system. FPPH55 models have a built-in FootPrint Pro filtration system located under the leftmost two fryers in a battery. FMPH55 models also have a built-in FootPrint Pro filtration system under the leftmost two stations of a battery. The difference between FPPH55s and FMPH55s is that FPPH55s have no holding stations (i.e., the battery consists only of fryers) while the FMPH55s have a holding station at one of the positions in the battery. For example, an FPPH355 consists of three fryers with built-in filtration; an FMH355, by comparison, consists of two fryers and one holding station with built-in filtration. A PH355 consists of three fryers without built-in filtration.
All Pro H55 Series Gas fryers are of an open-frypot design with no tubes and have a hand-sized opening into the deep cold zone, which makes cleaning the stainless frypot quick and easy.
Heating is supplied by a pair of infrared burner assemblies mounted on each side of the frypot. Combustion air for the burners is supplied by a dedicated blower mounted on the front of the frypot. Pro H55 Series Gas fryers can be configured for natural gas, propane (LP), or manufactured gas, as required by the customer.
Each frypot is equipped with a temperature probe for precise temperature control.
All Pro H55 Series Gas fryers come standard with electronic ignition, melt cycle and boil-out mode. Control options include Computer Magic III.5 computers, solid-state (analog) controllers, digital controllers, and basket lift timers.
All fryers in this series require an external source of AC electrical power. Units can be configured for voltages ranging from 100 VAC to 240 VAC.
FMPH55 and FPPH55 fryers are shipped completely assembled. PH55 fryers may require installation of legs or optional casters at the point of use. All fryers are shipped with a package of standard accessories. Each fryer is adjusted, tested, and inspected at the factory before crating for shipment.
1.6 Installation, Operating, and Service Personnel
Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.7. All installation and service on Frymaster
equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7.
1.7 Definitions
QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual.
1-3
QUALIFIED INSTALLATION PERSONNEL
Qualified installation personnel are individuals, firms, corporations, and/or companies which, either in person or through a representative, are engaged in and are responsible for the installation of gas­fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas precautions involved, and have complied with all requirements of applicable national and local codes.
QUALIFIED SERVICE PERSONNEL
Qualified service personnel are those who are familiar with Frymaster equipment and who have been authorized by Frymaster, L.L.C. to perform service on the equipment. All authorized service per­sonnel are required to be equipped with a complete set of service and parts manuals, and to stock a minimum amount of parts for Frymaster equipment. A list of Frymaster Factory Authorized Servic­ers (FAS’s) is located on the Frymaster website at www.frymaster.com. Failure to use qualified service personnel will void the Frymaster warranty on your equipment.
1.8 Shipping Damage Claim Procedure
Your Frymaster equipment was carefully inspected and packed before leaving the factory. The transportation company assumes full responsibility for safe delivery upon its acceptance of the equipment for transport.
What to do if your equipment arrives damaged:
1. File a claim for damages immediately, regardless of the extent of damages.
2. Inspect for and record all visible loss or damage, and ensure that this information is noted on
the freight bill or express receipt and is signed by the person making the delivery.
3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be
recorded and reported to the freight company or carrier immediately upon discovery. A concealed damage claim must be submitted within 15 days of the date of delivery. Ensure that the shipping container is retained for inspection.
Frymaster
DOES NOT ASSUME RESPONSIBILITY FOR DAMAGE OR LOSS
INCURRED IN TRANSIT.
1-4
PRO H55 SERIES GAS FRYER
CHAPTER 2: INSTALLATION INSTRUCTIONS
2.1 General Installation Requirements
Qualified, licensed, and/or authorized installation or service personnel, as defined in Section
1.7 of this manual, should perform all installation and service on Frymaster equipment.
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.7 of this manual.
Failure to use qualified, licensed, and/or authorized installation or service personnel (as de­fined in Section 1.7 of this manual) to install, convert to another gas type or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel.
Where conflicts exist between instructions and information in this manual and local or na­tional codes or regulations, installation and operation shall comply with the codes or regula­tions in force in the country in which the equipment is installed.
DANGER Building codes prohibit a fryer with its open tank of hot oil being installed beside an open flame of any type, including those of broilers and ranges.
Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Shipping Damage Claim Procedure in Chapter 1.)
DANGER Frymaster appliances equipped with legs are for stationary installations. Appliances fitted with legs must be lifted during movement to avoid damage to the appliance and bodily injury. For movable installations, optional equipment casters must be used. Questions? Call 1-800-551-8633.
CLEARANCE AND VENTILATION
The fryer(s) must be installed with a 6” (150 mm) clearance at both sides and back when installed adjacent to combustible construction; no clearance is required when installed adjacent to noncombustible construction. A minimum of 24” (600 mm) clearance should be provided at the front of the fryer.
DANGER
No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633.
2-1
One of the most important considerations of efficient fryer operation is ventilation. Make sure the fryer is installed so that products of combustion are removed efficiently, and that the kitchen ventilation system does not produce drafts that interfere with burner operation.
The fryer flue opening must not be placed close to the intake of the exhaust fan, and the fryer must never have its flue extended in a “chimney” fashion. An extended flue will change the combustion characteristics of the fryer, causing longer recovery time. It also frequently causes delayed ignition. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear must be kept clear and unobstructed.
DANGER This appliance must be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to the health of personnel in the room in which it is installed.
Fryers must be installed in an area with an adequate air supply and adequate ventilation. Adequate distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank. Filters should be installed at an angle of 45º. Place a drip tray beneath the lowest edge of the filter. For U.S. installation, NFPA standard No. 96 states, “A minimum distance of 18 in. (450 mm) should be maintained between the flue outlet and the lower edge of the grease filter.”
Frymaster recommends that the minimum distance be 24 in. (600 mm) from the flue outlet to the bottom edge of the filter when the appliance consumes more than 120,000 BTU per hour.
For installations in the United States, information on construction and installation of ventilating hoods can be found in the NFPA standard cited above. A copy of the standard may be obtained from the National Fire Protection Association, Battery March Park, Quincy, MA 02269.
NATIONAL CODE REQUIREMENTS
The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped “NAT” only to natural gas, those stamped “PRO” only to propane gas, and those stamped “MFG” only to manufactured gas.
Installation shall be made with a gas connector that complies with national and local codes, and, where applicable, CE codes. Quick-disconnect devices, if used, shall likewise comply with national, local, and, if applicable, CE codes.
ELECTRICAL GROUNDING REQUIREMENTS
All electrically operated appliances must be grounded in accordance with all applicable national and local codes, and, where applicable, CE codes. All units (cord connected or permanently connected) should be connected to a grounded power supply system. A wiring diagram is located on the inside of the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages.
DANGER This appliance is equipped with a three-prong (grounding) plug for your protection against electrical shock, and must be plugged directly into a properly grounded three-prong receptacle. Do not cut, remove, or otherwise bypass the grounding prong on this plug!
2-2
DANGER This appliance requires electrical power for operation. Place the gas control valve in the OFF position in case of a prolonged power outage. Do not attempt to operate this appliance during a power outage.
AUSTRALIAN REQUIREMENTS
To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.
FCC COMPLIANCE
The user is cautioned that any changes or modifications to Frymaster computers not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Frymaster computers have been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While these devices are verified as Class A devices, they have been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
The user may find the booklet “How to Identify and Resolve Radio-TV Interference Problems” helpful. It is prepared by the Federal Communications Commission and is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions.
2.2 Caster/Leg Installation
Depending upon the specific configuration ordered, your fryer may have been shipped without installed casters or legs. DO NOT INSTALL THIS APPLIANCE WITHOUT CASTERS OR
LEGS. If the appliance requires the installation of casters or legs, install them in accordance with the instructions included in your accessory package.
2.3 Pre-Connection Preparations
DANGER
DO NOT connect this appliance to the gas supply before completing each step in this section.
After the fryer has been positioned under the exhaust hood, ensure the following has been accomplished:
1. Adequate means must be provided to limit the movement of fryers without depending upon the
gas line connections. If a flexible gas hose is used, a restraining cable must be connected at all times when the fryer is in use. The restraining cable and installation instructions are packed with the flexible hose in the accessories box that was shipped with your unit.
2-3
2. Single unit fryers must be stabilized by installing restraining chains on fryers equipped with
O
O
casters or anchor straps on fryers equipped with legs. Follow the instructions in the accessory pack to install the chains or straps.
DANGER Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over, and cause injury. The appliance area must be kept free and clear of combustible material at all times.
3. Level fryers equipped with legs by screwing out the legs approximately 1 inch then adjusting
them so that the fryer is level and at the proper height in the exhaust hood. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the hood be 24 in. (600 mm) when the appliance consumes more than 120,000 BTU per hour. NOTE: There are no built-in leveling devices on fryers equipped with casters. The floor where the fryer is to be installed must be level.
4. Test the fryer electrical system:
a. Plug the fryer electrical cord(s) into a grounded electrical receptacle.
b. Place the power switch in the ON position.
For fryers equipped with solid-state (analog) controls, verify that the power and heat
lights are lit.
For fryers having computer or digital displays, verify that the display indicates CYCL.
c. Place the fryer power switch in the OFF position. Verify that the power and heat lights are
out, or that the display is blank.
5. Refer to the data plate on the inside of the fryer door to determine if the fryer burner is
configured for the proper type of gas before connecting the fryer quick-disconnect device or piping from the gas supply line.
6. Verify the minimum and maximum gas supply pressures for the type of gas to be used in
accordance with the accompanying tables.
CE Standard
for Incoming Gas Pressures
for Fryers Manufactured After April 1999
Pressure
Gas
G20 20 2 x 3.40 2 x 3.40 7 mbar 7 mbar G25 20 or 25 2 x 3.40 2 x 3.40 10 mbar 10 mbar G30 28/30 or 50 2 x 2.05 2 x 2.05 17 mbar 17 mbar G31 37 or 50 2 x 2.05 2 x 2.05 20 mbar 20 mbar
(1) mbar = 10,2 mm H
(mbar)
Orifice Diameter Single
(1)
Vat
2
Dual
Vat
Regulator Pressure
Single
Vat
Dual
Vat
for Fryers Manufactured Through April 1999
Gas
G20 20 2 x 3.40 2 x 3.40 7 mbar 7 mbar G25 20 or 25 2 x 3.40 2 x 3.40 10 mbar 9 mbar G30 28/30 or 50 2 x 2.05 2 x 2.05 17 mbar 16,5 mbar G31 37 or 50 2 x 2.05 2 x 2.05 20,2 mbar 18,5 mbar
(1) mbar = 10,2 mm H
CE Standard
for Incoming Gas Pressures
Pressure
(mbar)
Orifice Diameter Single
(1)
Vat
2
Dual
Vat
Regulator Pressure
Single
Vat
Dual
Vat
2-4
Non-CE Standard
for Incoming Gas Pressures
Gas Minimum Maximum
Natural
LP
6" W.C.
1.49 kPa
14.93 mbar 11" W.C.
2.74 kPa
27.37 mbar
14" W.C.
3.48 kPa
34.84 mbar 14" W.C.
3.48 kPa
34.84 mbar
7. For fryers equipped with a FootPrint Pro system or basket lifts, plug the electrical cord(s) into a power receptacle behind the fryer.
2.4 Connection to Gas Line
DANGER Before connecting new pipe to this appliance, the pipe must be blown out thor­oughly to remove all foreign material. Foreign material in the burner and gas con­trols will cause improper and dangerous operation.
DANGER When pressure-testing incoming gas supply lines, disconnect the fryer from the gas line if the test pressure will be ½ PSIG (3.45 kPa, 13.84 inches W.C.) or greater to avoid damage to the fryer’s gas tubes and gas valve(s).
DANGER All connections must be sealed with a joint compound suitable for the gas being used and all connections must be tested with a solution of soapy water before light­ing any pilots.
Never use matches, candles, or any other ignition source to check for leaks. If gas odors are detected, shut off the gas supply to the appliance at the main shut-off valve and immediately contact the local gas company or an authorized service agency for service.
DANGER “Dry-firing” your unit will cause damage to the frypot and can cause a fire. Always ensure that melted shortening, cooking oil, or water is in the frypot before firing the unit.
The size of the gas line used for installation is very important. If the line is too small, the gas pressure at the burner manifold will be low. This may cause slow recovery and delayed ignition. The incoming gas supply line should be a minimum of 1½” (38 mm) in diameter. Refer to the chart on the following page for the minimum sizes of connection piping.
2-5
Gas Connection Pipe Sizes
(Minimum incoming pipe size should be 1 1/2" (41 mm))
4 or more
Gas Single Unit 2 - 3 Units
Natural
3/4" (22 mm)
1" (28 mm) 1 1/4" (36 mm)
units*
Propane 1/2" (15 mm) 3/4" (22 mm) 1" (28 mm) Manufactured 1" (28 mm) 1 1/4" (36 mm) 1 1/2" (41 mm)
* For distances of more than 20 feet (6 m) and/or more than 4 fittings or elbows, increase the connection by one pipe size. Units with four or more vats require two gas connections.
The Pro H55 Series gas fryer has received the CE mark for the countries and gas categories indicated in the table below. NOTE: The nominal heat input (QN) is 21kW except for AT, DE, LU and category 3P/B, which is 23kW.
COUNTRIES CATEGORIES GAS PRESSURE (MBAR)
AUSTRIA (AT) II2H3B/P BELGIUM (BE) DENMARK (DK) II2H3B/P
FRANCE (FR)
FINLAND (FI) II2H3B/P
GERMANY (DE)
GREECE (GR) II2H3+ ITALY (IT) II2H3+ IRELAND (IE) II2H3+ LUXEMBOURG (LU) II2E3B/P
NETHERLANDS (NL)
NORWAY (NO) I3B/P G30, G31 30 PORTUGAL (PT) II2H3+
SPAIN (ES)
SWEDEN (SE) II2H3B/P UNITED KINGDOM (UK) II2H3+
CE Approved Gas Categories by Country
G20 20
I2E(R)B G20, G25 20, 25
I3+ G30, G31 28-30, 37
II2Esi3+
II2Esi3P
II2ELL3B/P
I3P G31 50
II2L3P
II2L3B/P
II2H3+ II2H3P
G30, G31 50
G20 20 G30, G31 30 G20, G25 20, 25 G30, G31 28-30, 37 G20, G25 20, 25
G31 50
G20 20 G30, G31 30 G20, G25 20 G30, G31 50
G20 20 G30, G31 28-30, 37
G20 20 G30, G31 28-30, 37
G20 20 G30, G31 28-30, 37
G20 20 G30, G31 50
G25 25
G31 50
G25 25 G30, G31 30
G20 20 G30, G31 28-30, 37
G20 20 G30, G31 28-30, 37
G20 20
G31 37, 50
G20 20 G30, G31 30
G20 20 G30, G31 28-30, 37
CE Standard
Required airflow for the combustion air supply is 2m3/h per kW.
2-6
1. Connect the quick-disconnect hose to the fryer quick-disconnect fitting under the front of the fryer and to the building gas line.
NOTE: Some fryers are configured for a rigid connection to the gas supply line. These units are connected to the gas supply line at the rear of the unit.
When using thread compound, use very small amounts on male threads only. Use a pipe thread compound that is not affected by the chemical action of LP gases (Loctite™ PST56765 Sealant is one such compound). DO NOT apply compound to the first two threads. Doing so may allow some of the compound to enter the gas stream, resulting in clogging of burner orifices and/or the control valve.
2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks. A soap solution should be used for this purpose.
3. Close the fryer drain valve and fill the frypot with water and boil-out solution to the bottom OIL LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are described in the “Lighting Instructions” and “Boiling Out the Frypot” topics found in Chapter 3 of this manual.
DANGER “Dry-firing” your unit will cause damage to the frypot and can cause a fire. Always ensure that melted shortening, cooking oil, or water is in the frypot before firing your unit.
4. The burner manifold pressure should be checked at this time by the local gas company or an
authorized service agent. The tables below and on the following page list the burner manifold gas pressures for the various gas types that can be used with this equipment.
CE Standard
Burner Manifold Gas Pressures
for Fryers Manufactured After April 1999
Pressure (mbar)
Single
Gas
Natural Gas Lacq (G20) under 20 mbar
Natural Gas Groningue * (G25) under 25 mbar
Natural Gas Groningue (G25) under 20 mbar
Butane (G30) at 28/30 or 50 mbar
Propane (G31) under 37 or 50 mbar
* Belgian G25 = 7,0 mbar (single or dual)
Vat
77
10 10
10 10
17 17
20 20
Dual
Vat
CE Standard
Burner Manifold Gas Pressures
for Fryers Manufactured Through April 1999
Gas
Natural Gas Lacq (G20) under 20 mbar
Natural Gas Gronigue * (G25) under 25 mbar
Natural Gas Gronigue (G25) under 20 mbar
Butane (G30) at 28/30 or 50 mbar
Propane (G31) under 37 or 50 mbar
* Belgian G25 = 7,0 mbar (single) or 6,5 (dual)
2-7
Pressure (mbar)
Single
Vat
76,5
10 9
10 9
17 16,5
20,2 18,5
Dual
Vat