/ Perfect Welding / Solar Energy / Perfect Charging
FRONIUS IG PLUS
/ The allrounder with maximum yield.
/ Fronius
MIX™ technology
/ HF transformer
switchover
/ WLAN
interface
/ Smart Grid
Ready
/ The Fronius IG Plus generation of inverters represents an evolution of the proven Fronius IG product family. Power
categories from 3.5 to 12 kW promise suitability for every possible system size. With a maximum efficiency of 95.9
%, the Fronius IG Plus range achieves one of the highest values for transformer inverters.
Technical daTa Fronius iG Plus (35 V-1, 50 V-1, 55 V-1, 60 V-1, 55 V-2)
inPuT daTa35 V-150 V-155 V-160 V-155 V-2
DC maximum power at cos φ = 13,710 W4,260 W5,260 W6,320 W5,260 W
Max. input current (I
Max. array short circuit current24.3 A27.9 A34.4 A41.3 A34.4 A
Min. input voltage (U
Feed-in start voltage (U
Nominal input voltage (U
Max. input voltage (U
MPP voltage range (U
Number of DC inputs6
ouTPuT daTa35 V-150 V-155 V-160 V-155 V-2
AC nominal output (P
Max. output power3,500 VA4,000 VA 5,000 VA6,000 VA5,000 VA
Max. output current (I
Grid connection (U
Min. output voltage (U
Max. output voltage (U
Frequency (f
Frequency range (f
Distortion factor< 3 %
Power factor (cos φ
)50 Hz / 60 Hz
r
) 16.2 A18.6 A22.9 A27.5 A22.9 A
dc max
) 230 V
dc min
)260 V
dc start
)370 V
dc,r
)600 V
dc max
– U
mpp min
)3,500 W4,000 W5,000 W6,000 W5,000 W
ac,r
)15.2 A17.4 A21.7 A26.1 A10.9 A
ac max
)1~NPE 230 V2~NPE 400 V / 230 V
ac,r
)180 V
ac min
)270 V
ac max
– f
)46 – 65 Hz
min
max
)0.75 – 1 ind. / cap.
ac,r
)230 – 500 V
mpp max
1)
General daTa35 V-150 V-155 V-160 V-155 V-2
Dimensions (height x width x depth)673 x 434 x 250 mm968 x 434 x 250 mm
Weight23.8 kg36.9 kg
Degree of protectionIP 54
Protection class1
Overvoltage category (DC / AC)2 / 3
Night-time consumptionca. 1 W
Inverter conceptHF transformer
CoolingRegulated air cooling
InstallationIndoor and outdoor installation
Ambient temperature rangefrom -20°C to +55°C
Permitted humidity0 % to 95 %
DC connection technologyScrew terminal connection 1.5 mm² – 16 mm²
AC connection technolog yScrew terminal connection 2.5 mm² – 35 mm²
Certicates and compliance with standards
Fronius IG Plus 55 V-1, Fronius IG Plus 55 V-2 and Fronius IG Plus 60 V-1 devices do not comply with the German medium-voltage directive. Fronius IG Plus 55 V-1 and Fronius IG Plus 60
V-1 are not certied in accordance with the German low-voltage directive. Further information regarding the availability of the inverters in your country can be found at www.fronius.com.
1)
country-specic 2) Please refer to the information in the operating instructions regarding correct installation of the inverter (e.g. IP 44 applies to Australia).
DIN V VDE V 0126-1-1, ÖVE / ÖNORM E 8001-4-712, UTE C15-712-1, EN 50438, G83, G59, C 10 / 11,
CER 06-190, CEI 0-21, AS 4777-1, AS 4777-2, AS 4777-3, VDE AR N 4105,
Generating systems on the medium-voltage network (BDEW)
2)
Page 2
Fronius iG Plus 50 V-1 eFFiciency curVeFronius iG Plus 50 V-1 TemPeraTure deraTinG
EFFICIENCY [%]
STANDARDISED OUTPUT POWER PAC/P
AC,R
89
88
90
91
92
93
96
00,10,20,30,40,50,60,70,80,91
■
230 V ■ 370 V ■ 500 V
94
95
OUTPUT POWER [W ]
AMBIENT TEMPERATURE [°C]
1.000
2.000
3.000
4.000
5.000
20
25
303540455055
230 V 370 V 500 V
Technical daTa Fronius iG Plus (35 V-1, 50 V-1, 55 V-1, 60 V-1, 55 V-2)
DC insulation measurementWarning/shutdown (depending on countr y setup) at R
Overload behaviourOperating point shift, power limitation
DC circuit breakerIntegrated
inTerFaces35 V-150 V-1 55 V-160 V-155 V-2
Optional with Fronius DatamanagerWLAN, Ethernet, Modbus TCP, 6 digital inputs, 4 digital inputs/outputs, Datalogger, Webserver
Further information regarding the availability of the inverters in your country can be found at www.fronius.com.
1)
and at U
mpp min
/ U
/ U
dc,r
mpp max.
55 V-2
< 600 kOhm
ISO
Page 3
Technical daTa Fronius iG Plus (60 V-3 / 80 V-3 / 100 V-3 / 120 V-3 / 150 V-3)
inPuT daTa60 V-380 V-3100 V-3 120 V-3150 V-3
DC maximum power at cos φ = 16,300 W7,3 60 W8 ,430 W10 ,59 0 W12,770 W
Max. input current (I
Max. array short circuit current41. 3 A48.0 A55.1 A69.3 A83.4 A
Min. input voltage (U
Feed-in start voltage (U
Nominal input voltage (U
Max. input voltage (U
MPP voltage range (U
Number of DC inputs6
ouTPuT daTa60 V-380 V-3100 V-3 120 V-3150 V-3
AC nominal output (P
Max. output power6,000 VA7,000 VA8,000 VA10,000 VA12,000 VA
Max. output current (I
Grid connection (U
Min. output voltage (U
Max. output voltage (U
Frequency (f
)50 Hz / 60 Hz
r
Frequency range (f
Distortion factor< 3 %
Power factor (cos φ
General daTa60 V-380 V-3100 V-3 120 V-3150 V-3
Dimensions (height x width x depth)1,263 x 434 x 250 mm
Weight49.2 kg
Degree of protectionIP 54
Protection class1
Overvoltage category (DC / AC)2 / 3
Night-time consumptionca. 1 W
Inverter conceptHF transformer
CoolingRegulated air cooling
InstallationIndoor and outdoor installation
Ambient temperature rangefrom -20°C to +55°C
Permitted humidity0 % to 95 %
DC connection technologyScrew terminal connection 1.5 mm² – 16 mm²
AC connection technolog yScrew terminal connection 2.5 mm² – 35 mm²
Certicates and compliance with standards
Fronius IG Plus 60 V-3 and Fronius IG Plus 80 V-3 devices do not comply with the German medium-voltage directive.
Further information regarding the availability of the inverters in your country can be found at www.fronius.com.
1)
country-specific
2)
Please refer to the information in the operating instructions regarding correct installation of the inverter (e.g. IG 44 applies to Australia).
) 27. 5 A32 .0 A36.7 A46.2 A55.6 A
dc max
) 230 V
dc min
)260 V
dc start
)370 V
dc,r
)600 V
dc max
– U
mpp min
)6,000 W7,000 W8,000 W10,000 W12,000 W
ac,r
)8.7 A10.2 A11.6 A14.5 A17.4 A
ac max
)3~NPE 400 V / 230 V
ac,r
)180 V
ac min
)270 V
ac max
– f
)46 – 65 Hz
min
max
)0.75 – 1 ind. / cap.
ac,r
)230 – 500 V
mpp max
1)
2)
DIN V VDE V 0126-1-1. ÖVE / ÖNORM E 8001-4-712. UTE C15-712-1. EN 50438. G83. G59. C 10 / 11.
CER 06-190. CEI 0-21. AS 4777-1. AS 4777-2. AS 4777-3. VDE AR N 4105.
Generating systems on the medium-voltage network (BDEW)
Broad 3-Phase inVerTer
ranGe From 6 Bis 12 KW!
Page 4
Fronius iG Plus 150 V-3 eFFiciency curVeFronius iG Plus 150 V-3 TemPeraTure deraTinG
OUTPUT POWER [W]
AMBIENT TEMPERATURE [°C]
1.000
3.000
5.000
7.000
9.000
11.000
13.000
2025303540455055
230 V 370 V 500 V
96
94
92
EFFICIENCY [%]
90
88
86
00,10,20,30,40,50,60,70,80,91
STANDARDISED OUTPUT POWER PAC/P
230 V ■ 370 V ■ 500 V
■
AC,R
Technical daTa Fronius iG Plus (60 V-3 / 80 V-3 / 100 V-3 / 120 V-3 / 150 V-3)
DC insulation measurementWarning/shutdown (depending on country setup) at R
Overload behaviourOperating point shift, power limitation
DC circuit breakerIntegrated
inTerFaces60 V-380 V-3100 V-3120 V-3150 V-3
Optional with Fronius DatamanagerWLAN, Ethernet, Modbus TCP, 6 digital inputs, 4 digital inputs/outputs, Datalogger, Webserver
Further information regarding the availability of the inverters in your country can be found at www.fronius.com.
1)
and at U
mpp min
/ U
/ U
dc,r
mpp max.
/ Perfect Welding / Solar Energy / Perfect Charging
WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF POSSIBILITY.
/ Whether welding technology, photovoltaics or battery charging technology − our goal is clearly defined: to be the innovation leader. With around
Fronius India Private Limited
GAT no 312, Nanekarwadi
Chakan, Taluka - Khed District
Pune 410501
India
pv-sales-india@fronius.com
www.fronius.in
3,300 employees worldwide, we shift the limits of what’s possible - our record of over 900 granted patents is testimony to this. While others progress
step by step, we innovate in leaps and bounds. Just as we’ve always done. The responsible use of our resources forms the basis of our corporate policy.
Further information about all Fronius products and our global sales partners and representatives can be found at www.fronius.com
Fronius Australia Pty Ltd.
90-92 Lambeck Drive
Tullamarine VIC 3043
Australia
pv-sales-australia@fronius.com
www.fronius.com.au