Fronius How to setup Fronius Sensors Quick Guide [EN]

HOW TO SETUP FRONIUS SENSOR BOX/CARD
FOR FRONIUS SNAPINVERTER (FRONIUS GALVO, PRIMO, SYMO, ECO)
© Fronius International GmbH
Version 1. 0 / 2019
Fronius Solar Energy
Fronius reserves all rights, in particular rights of reproduction, distribution and translation.
No part of this work may be reproduced in any way without the written consent of Fronius. It must not be saved, edited, reproduced or
distributed using any electrical or electronic system.
You are hereby reminded that the information published in this document, despite exercising the greatest of care in its preparation, is
subject to change and that neither the author nor Fronius can accept any legal liability.
Gender-specific wording refers equally to female and male form.
.
.............................................................................................................................................................................
Quick Guide: How to setup Fronius Sensor Box/Card
2/14
TABLE OF CONTENTS
1
SCOPE OF USE ...............................................................................................................................4
2
HOW TO CONNECT A FRONIUS SENSOR BOX/CARD INTO A FRONIUS SOLAR.NET LOOP4
3
FRONIUS SENSOR BOX/CARD TERMINAL OVERVIEW .............................................................5
4
DIGITAL INPUTS .............................................................................................................................6
5
ANALOG INPUT FOR CURRENT SIGNAL....................................................................................7
6
TEMPERATURE CHANNELS (T1 / T2) ...........................................................................................8
7
ANALOG INPUT FOR VOLTAGE SIGNAL .....................................................................................9
8
COMMISSIONING THE SENSOR BOX/CARD ............................................................................ 10
.............................................................................................................................................................................
Quick Guide: How to setup Fronius Sensor Box/Card
3/14
1 SCOPE OF USE
The Fronius Sensor Box/Card collects data from connected sensors and communicates this data to the
Fronius Datamanager Box/Card via the Fronius Solar.Net communication loop.
It is not possible to retrieve data directly from the Fronius Sensor Box/Card without a Fronius Datamanager
Box/Card to manage communication.
2 HOW TO CONNECT A FRONIUS SENSOR BOX/CARD INTO A
FRONIUS SOLAR.NET LOOP
SnapINverters come equipped with 2 RJ45 sockets labelled IN and OUT. The Ethernet cable connection
should always run from the OUT socket on one inverter, to the IN socket on the next inverter or Fronius
Sensor Box/Card.
RJ45 termination plugs (supplied with the Fronius Datamanager) must then be installed in the empty Solar
Net IN and OUT connection sockets at the start and end of the daisy chain.
Up to 99 slave inverters and up to 10 Fronius Sensor Boxes/Cards can be connected to a master inverter.
To maximise communication speed, the number of devices and cable lengths should be kept to a minimum.
.............................................................................................................................................................................
Quick Guide: How to setup Fronius Sensor Box/Card
4/14
3 FRONIUS SENSOR BOX/CARD TERMINAL OVERVIEW
(1) Power supply +5V for digital channel
(2) Digital input channel D1
(3) Digital input channel D2
(4) GND for digital channel
(5) Analog input for current signal
(6) Temperature measurement T1 (only for PT1000)
(7) Temperature measurement T2 (only for PT1000)
(8) Analog input for voltage signal (0-1000mV)
.............................................................................................................................................................................