Frigidaire LRA08HZT10, LRA08HZT11, LRA12HZT20, LRA12HZT21, LRA12HZT210 Installation Guide

...
0 (0)
READ BEFORE INSTALLING UNiT
For SLO3 Air Conditoner (8K~12K BTU)
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp
edges that may be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to
move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over
an extended period of time.
metal fins of front and rear coils.
Make sure air conditioner does not fall during installation.
Tools and Parts:
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools
listed here.
TOOLS NEEDED
Flat-blade and Phillips screwdrivers
Level
Tape measure
o Drill and 3/16", 1/8"_ 3/32", or smaller drill bit
Through-the-wall Installation:
In addition to the tools listed above, the following tools are needed for through-the-wall installation.
TOOLS NEEDED
saw
1" (2.5 cm) or thicker lumber
caulk
#10 X 1" wood screws (7)
Parts Supplied
Check that all parts are included in parts package:
Hardware Qty. Hardware
#10 X 1/2" pan - head
Phillips screws
#10 X 3/4" round - headscrews
#10 X 1/4" pan - head
Phillips screws
Top channel
side curtains
5
2
Window sash seal
Foam seal
window lock bracket
Safety Lock
(for Vinyl-Clad window)
weather seals
(6"X3/4"X1/12")
Qty.
1
2
5
2020217A1407
Installation parts are supplied for double-hung windows up to 36" (91.4 cm) wide. A special Wide Window Kit is
available from your dealer or service center. See "Accessories."
Do not use any screws other than those specified here.
Location Requirements:
IMPORTANT:Observe all governing codes and ordinances. Check the location where air conditioner will be installed,
Proper installation is your responsibility, Make sure you have everything necessary for correct installation,
Grounded electrical outlet within 4 ft (122 cm) of where the power cord exits the air conditioner.
Free movement of air in room to be cooled.
A large enough opening for the air conditioner.
Adequate wall support for weight of air conditioner. Air conditioner weights between 70 and 85 Ibs (32 to 40 kgs).
Do not use an extension cord.
Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet Iouvers.(FIG.1 )
Window Installation:
Window opening measurements (FIG.2) :
26-7/8" to 36" (68.3 cm to 91.4 cm) opening width.
16-1/2" (41.9 cm) minimum opening height.
FIG.1 FIG.2
A
A. Cabinet louvers
r- J
[ !
A. 26-7/8" (68.3 cm) minimum
B. 16-1/2" (41.9 cm) minimum
Remove packaging material:
Remove and dispose of/recycle packaging materials. Remove tape and glue residue from surfaces before installing
the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water
and dry.
Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your air conditioner.
Handle the air conditioner gently.
1. Remove the air conditioner from the carton and place it on cardboard.
2. Remove 1 shipping screw from each side of the cabinet (FIG.3).
3. Remove front panel by removing 1 Phillips screw from each side of the front panel. Set screws aside and save
(FIG.4).
4. Pull on the handles to slide the air conditioner out of the cabinet. Place the air conditioner on cardboard (FIG.5).
Loading...
+ 4 hidden pages