FFLE3900UW
LAUNDRY CENTER
3.9 CU. FT. WASHER D.O.E.
5.5 CU. FT. DRYER D.O.E.
ELECTRIC
AVAILABLE
COLORS
White
PRODUCT DIMENSIONS
Height 76"
Width 27"
Depth 31-1/2"
MORE EASY-TO-USE FEATURES
10 Wash Cycles
Features 10 wash cycles to meet all of your
washing needs such as Delicate, Activewear,
Bulky and Colors.
6 Dry Cycles
Features 6 dry cycles to meet all of your drying
needs such as Delicate, Activewear, Bulky, and
Air Fluff.
4 Timed Dryer Cycles
Select your desired drying time limit that works
with your schedule.
Cycle Status Lights
Green LED lights keep you informed on when
the cycle is washing, rinsing, spinning and done.
End-of-Cycle Signal
Always know when your laundry is done with
the end-of-cycle beep.
SIGNATURE FEATURES
Excellent Cleaning
Performance
The movement of the agitator
gives you an excellent cleaning
performance to ensure your
clothes come out clean.
Largest Washer
Capacity
Fit more in every load with
3.9 cu. ft. washer capacity.
MaxFill™
MaxFill™ option allows for
the maximum water level
for the selected cycle.
Quick Wash
and Dry Cycles
Get a load done faster
with quick wash and
quick dry cycles.
frigidaire.com

FFLE3900UW
LAUNDRY CENTER
ELECTRIC
WASHER FEATURES
Washer Type Top Load
Total Capacity D.O.E. (Cu. Ft.) 3.9
Controls Ready-Select®
Washer Interior Stainless Steel
Vibration Control System Yes
Wash System Agitator
Fresh Water Rinse Yes
Water Level Adjustments 3
Bleach Dispenser / Detergent Dispenser Yes / No
Cycle Signal Yes
Agitate Speeds (Strokes / Min.) Variable
Spin Speeds (RPM) 850
WASH CYCLES
Wash Cycles 10
WASHER OPTIONS
Temperature Selections 3
Water Levels 3 Options
DRYER FEATURES
Total Capacity D.O.E. (Cu. Ft.) 5.5
Dryer Drum Interior Painted Steel
Cycle Signal Yes
Tumble Speed (RPM) 50
Lint Screen Yes
DRY CYCLES
Dry Cycles 6
DRYER OPTIONS
Temperature Selections 3
Dryness Level Selections 0
Timed Dry (Minutes) 15, 30, 60, 90
OPTIONAL ACCESSORIES
Mobile Home Installation Kit PN # 137067200
Drain Hose Extension Kit PN # 134592700
SPECIFICATIONS
Maximum Exhaust Duct Length1 (Ft.) 56
Power Supply Connection Location Middle Rear
Water Inlet Connection Location Right Rear
Voltage Rating 240V / 60Hz / 30A
Connected Load (kW Rating) @ 240 Volts 5.1
Amps @ 240 Volts 22
Heating Element @ 240 Volts (Watts) 4,500
Shipping Weight (Approx.) 275 Lbs.
1
Rigid metal duct preferred, semi-rigid optional and allow deductions for
elbows and vents. Refer to Installation Guide on web for additional information.
PRODUCT DIMENSIONS
A - Height 76"
B - Width 27"
C - Depth 31-1/2"
Depth with Door Open 90° 47-1/2"
B
A
C
•
10200 David Taylor Drive
USA
•
CANADA
5855 Terry Fox Way
•
Charlotte, NC 28262
•
Mississauga, ON L5V 3E4
•
1-800-FRIGIDAIRE
•
1-800-265-8352
•
frigidaire.com
•
frigidaire.ca
Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Specifications subject to change. Accessories information available on the web at frigidaire.com
© 2018 Electrolux Home Products, Inc.
FFLE3900U 03/18

FFLE3900UW
LAUNDRY CENTER
ELECTRIC
Front
27"
60" Power cord (rear)
9
17
5/8"
4" Exhaust
vent (rear)
3/8"
76"
Side
1
47
/2"
Alcove or Closet
Installation
Unit requires 1/8" minimum installation
clearance around sides and back of unit.
To achieve 1/8" minimum rear clearance,
unit MUST be vented straight back. Closet
installation requires additional 1" minimum
clearance between front of unit and vented
door. Door MUST be vented with 120 sq.
minimum louvered opening, equally
divided, located 3" from top and bottom
of door. A louvered door with equivalent
54
3/4"
1/8"
min. 1/8" min. 1/8" min.
air openings for full-length of door is
acceptable. Air openings MUST remain
unobstructed with door installed. For
additional installation details, refer to
Product Installation Guide on web.
1" min.
in.
1"
min.
H/C Water inlets
(rear) - 48" hose length
51
1/2"
Hose
length
beyond
clamp
Drain
hose
1
42
/2"
retention
clamp
(rear)
26"26"
31
1/2"
INSTALLATION SPECIFICATIONS
•
Product Shipping Weight (approx.) – 275 Lbs.
•
Designed for HOME USE only, not recommended for commercial application.
•
Single phase 3- or 4-wire cable, 240 Volt, 60 Hertz AC only electrical supply
with ground required on separate circuit fused on both sides of line.
•
Voltage Ratings – 240V / 60Hz / 30A
•
Amps @ 240 Volts = 22
•
Connected Load (kW Rating) @ 240 Volts = 5.1 kW
•
Unit MUST employ a 3-conductor NEMA 10-30 type SRDT or 4-conductor
NEMA 14-30 type SRDT or ST (as required), rated at 240 volt AC minimum,
30 amp power supply cord marked for use with clothes dryers (not supplied).
•
Grounding through neutral link prohibited in specific applications and certain
locales, requiring use of 4-wire system. (For detailed electrical requirements,
refer to Product Installation Guide on web.)
•
Always consult local and national electric & plumbing codes.
•
Can be installed in alcove or closet requiring 1/8" minimum installation clearance
around sides and back of unit. To achieve 1/8" minimum rear clearance, dryer
MUST be vented straight back. Closet installation requires additional 1" minimum
clearance between front of unit and vented door. Door MUST be vented with
120 sq. in. minimum louvered opening, equally divided, located 3" from top and
bottom of door. A louvered door with equivalent air openings for full-length of
door is acceptable. Air openings MUST remain unobstructed with door installed.
(For additional installation details, refer to Product Installation Guide on web.)
•
Do NOT install in area exposed to dripping water or outdoor weather
conditions; where gasoline or other flammables are kept or stored; or where
dryer comes in contact with curtains, drapes or anything that will obstruct
flow of combustion and ventilation air.
•
For garage installation, dryer MUST be located minimum 18" above floor.
•
Floor MUST be solid with 1/2" maximum slope. Do NOT install on carpeted
surface.
•
Dryer MUST exhaust to outside of building, NOT into any concealed space.
37"
•
Exhaust installation requires minimum 4"-diameter rigid or semi-rigid metal
duct with approved, unobstructed vent hood having swing-out damper(s).
If installing rigid metal duct (preferred), do not exceed MAXIMUM venting run
length of 56 ft., allow deductions for elbows and vents. If installing semi-rigid
metal duct, do not exceed MAXIMUM venting run length of 8 ft., always allow
deductions for elbows and vents (Refer to Product Installation Guide on web
for additional information). Do NOT use flexible plastic or metal foil duct and
use shortest run possible.
•
Flush-to-wall installation allows for 4-way exhausting — straight back, down,
left and right. While vertical exhausting is acceptable, certain circumstances
could affect dryer’s performance; and unit will be positioned 4-1/2" from wall.
(Flush-to-wall exhausting may be done by going below dryer, then sideways.)
•
H/C water faucets MUST be installed within 42" of washer’s water inlet and
MUST be 3/4" with threading for laundry hose connection to connect to
48" inlet hoses.
•
Water pressure MUST be between 20 and 120 psi with NOT more than 10 psi
pressure difference between hot and cold.
•
Drain standpipe requires diameter of 1-1/4" min. and height of 33" min. / 65" max.
above floor, capable of eliminating 17 gallons per minute. Attached 52" drain
hose can reach 65"-high standpipe.
•
Leveling legs supplied to level dryer properly and reduce excessive noise and
vibration.
•
For manufactured or mobile home installation optional Mobile Home Installation
Kit (PN # 137067200) required. (For specific installation details, refer to Product
Installation Guide on web.)
OPTIONAL ACCESSORIES
•
Mobile Home Installation Kit – (PN # 137067200).
•
Drain Hose Extension Kit – (PN # 134592700).
Dryer
Washer
Alcove or Closet Installation
Vented
closet
door
60"
sq.
60"
sq.
in.
in.
•
10200 David Taylor Drive
USA
•
CANADA
5855 Terry Fox Way
•
Charlotte, NC 28262
•
Mississauga, ON L5V 3E4
•
1-800-FRIGIDAIRE
•
1-800-265-8352
•
frigidaire.com
•
frigidaire.ca
Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Specifications subject to change. Accessories information available on the web at frigidaire.com
© 2018 Electrolux Home Products, Inc.
FFLE3900U 03/18