FRIGIDAIRE FFHN2740PP User Manual

T
U
R
N
Mounting Plate Screws
Mounting Plate Screw
Motor Gear
Timing
Gear
Water Fill Adjustment
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Type A with Run / Start Capacitor
Operating Time
Freezer Temperature
Refrigerator Temperature
Low Side Pressure
High Side Pressure (last 1/3 cycle)
Wattage (last 1/3 cycle) 30 to 50 50 to 70
Amps (running)
Base Voltage 115 vac (127 vac max)
65°F (18°C) Ambient 90°F (32°C) Ambient
90 to 100% 100%
-5° to 2°F
(-20° to -17°C)
34° to 39°F
(1° to 4°C)
-2 to 6 psig
(-14 to 41 kPa)
85 to 105 psig
(586 to 724 kPa)
-1° to 3°F
(-18° to -16°C)
34° to 39°F
(1° to 4°C)
-2 to 6 psig
(-14 to 41 kPa)
120 to 135 psig
(827 to 931 kPa)
.4 to .8 .7 to .9
DEFROST SPECIFICATIONS
Thermal Cutout Heater Defrost
Cabinet Size:
27’ & 28’ SD, 22’ CD
Cut-in Cut-out Watts Ohms Cut-out
110°F
(43.3°C)
135°F
(57.2°C)
500 26.5 39°F
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
Heater
Termination
(4°C)
CONDENSER FAN MOTOR
Watts RPM Amps
3.1
1100 CW
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage 115 vac
Variable Capacity Compressor (VCC) Diagnostics (select models) If test 38 fails, diagnose as follows:
Check at the connector from the power cord
harness into the inverter board, located in the machine compartment.
(PUR and WHT wires)
Is Inverter Board receiving 115 VAC from power supply?
Check voltage supply.
Check and repair power
cord harness wiring and connections.
CAUTION
All electrical parts and wiring must be shielded from torch ame. DO NOT allow torch to touch insulation; it will char at 200°F and ash ignite (burn) at 500°F. Excessive heat will distort the
plastic liner.
Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use
screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle.
Water Fill Volume: The water ll adjustment screw will change the ll time. One full turn is equal to 20cc (.68 oz.). The correct ll is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the ll volume must be checked.
FREEZER ICE MAKER INFORMATION
(Where Applicable)
SERVICE DATA SHEET
A01871001
FREEZER ICE MAKER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
ERROR CODES SPECIAL MODES
Display
FZ FF FZ FF
Interpretation Mode
-- OP Open FF Thermistor Manual Defrost d F FF ٨ and FF ٧ / same to deactivate
OP -- Open FZ Thermistor Display/
Showroom
-- SH- Sabbath Sb Sb FZ ٧ and FF ٨ / same to deactivate
SH --
SY CF
SY CE
Shorted FZ
Thermistor
UI to Main Control Board communication failure; on start up
UI Main Control Board communica­tion error;
System Diagnostic
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring. Contact TID before replacing main control board.
• Refer to Service Manual for additional information.
after a period in operation
SY EF Evaporator fan failure
Check at Inverter Board on
Compressor (BLK and RED wires)
yes
Is Inverter Board receiving 10-15 VAC and 1-5 VDC from Main Control Board?
no
Check at Main Control Board
Identify and repair damaged wires or
poor connections between Main Control Board and Inverter Board.
no
(BLK/WHT and RED/BLK wires)
Is Main Control Board sending 10-15 VAC and 1-5 VDC to Inverter Board?
yes
Display Activate/Deactivate
(press for up to 10 sec. simultaneously)
77 77 FZ ٨ and FF ٧ / Power-on-Reset (POR)
No FF or FZ display,
FZ ٨ and FZ ٧ / FF ٨ to deactivate
all UI LEDs on.
Remove inverter box from the
compressor and check resistance across compressor winding pairs as
yes yes
shown.
Is resistance across all winding pairs equal?
no
Replace Compressor and Inverter Board.
no
Replace Main Control Board.
VCC Resistance Check
Check resistance between terminals 1 and 2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
Check connections from Inverter
Board to Compressor
Are connections from Inverter Board to Compressor intact?
Identify and repair damaged wires or poor connections between Inverter Board and Compressor.
no
Replace Inverter Board
SYSTEM DIAGNOSTIC MODE
Activate: Press
Deactivate: Press
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air ow as appropriate to determine results of tests.
Test To activate test: Passing result
First Screen
--
Second Screen
--
Third Screen
--
2 Defrost Heater Press power on-off Defrost heater on when “on”; off when “off”.
3* FF Light
(Incandescent Models)
9* FZ Light
(Incandescent Models)
12 VCC Condenser Fan Press power on-off Fan running when “on”; stopped when “off”
13* FF Light
(LED Models)
38 VCC Compressor Press power on-off Compressor running when “on”; stopped when “off”
15 Evaporator Fan Press power on-off Stopped when “off”. Listen for speed change from “LO” to “HI”.
20* FZ Light
(LED Models)
22 Damper Press power on-off With inspection mirror, observe damper open when “OP”; closed when “CL”
23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open
24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open
29 FF Thermistor Activates automati-
30 FZ Thermistor Activates automati-
33 Ambient Thermis-
tor @ Main Board
39 Evaporator
Thermistor
34* Ambient Thermis-
tor @ UI
0- Firmware
Parameters
2- Main Board
Firmware
4- UI Firmware Press power on-off Displays digit sequence; record
yes
FZ
٨ and
FZ
٧ for up to 10 sec. simultaneously. Press
FF
٨ for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
FF
٨ to advance through tests.
Note: Silence alarm.
-- Blank UI display, no lights illuminated, no shadowing.
-- All LED lights on UI illuminated.
-- Blank UI display, no lights illuminated, no shadowing.
Press power on-off FF lights on when “on”; off when “off”
Press power on-off FZ lights on when “on”, off when “off”
Press power on-off FF lights on when “on”; off when “off”
Press power on-off FZ lights on when “on”, off when “off”
UI shows temperature sensed by FF thermistor; pass if within 10°F of
cally
temperature measured with gauge at FF thermistor location. “OP” if open; “SH” if short
UI shows temperature sensed by FZ thermistor; pass if within 10°F of
cally
temperature measured with gauge at FZ thermistor location. “OP” if open; “SH” if short
Activates automati­cally
UI shows temperature sensed at main board; pass if within +20°F/­10°F of temperature measured with gauge at main board location. “OP” if open; “SH” if short
Activates automati­cally
UI shows temperature sensed by evaporator thermistor; pass if within 10°F of temperature measured with gauge at evaporator thermistor location. “OP” if open; “SH” if short
Activates automati­cally
UI shows temperature sensed at UI; pass if within +20°F/-10°F of temperature measured with gauge at UI location. “OP” if open; “SH”
if short
Press power on-off Displays digit sequence; record
Press power on-off Displays digit sequence; record
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualied repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.
If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.
Wire Diagram A01831001