PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
T
U
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
CONTROL SETTING
Type A with Run / Start
65°F (18°C) Ambient 90°F (32°C) Ambient
Capacitor
Operating Time
90 to 100% 100%
Freezer Temperature -5° to 2°F (-20° to -17°C) -1° to 3°F (-18° to -16°C)
Refrigerator Temperature 34° to 39°F (1° to 4°C) 34° to 39°F (1° to 4°C)
Low Side Pressure -2 to 6 psig ( -14 to 41 kPa) -2 to 6 psig (-14 to 41 kPa)
High Side Pressure (last 1/3
cycle)
85 to 105 psig (586 to 724 kPa) 120 to 135 psig (827 to 931
kPa)
Wattage (last 1/3 cycle) 30 to 50 50 to 70
Amps (running)
.4 to .8 .7 to .9
Base Voltage 115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
26’ & 28’ SD, 23’ CD
Thermostat Heater
Cut-in Cut-out Watts Ohms
25°F (-4°C) 47°F
500 26.5
(8°C)
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run
time.
CONDENSER FAN MOTOR
Watts RPM Amps
3.1 1100 CW Opposite Shaft 0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage 115 vac
FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1 Green / Yellow Ground
2 Yellow Water Valve
3 Black Line
4 Light Blue Neutral
NO
NC
NEUTRAL
RED
LINE
BLK
MOUNTING
PLATE
BRN
MOTOR
BLK
P-3
P-1
THERMAL
CUT-OUT
CE MAKER
I
GRN / YEL
MOLD
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch
to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive
heat will distort the plastic liner.
POWER
ICE MAKER
RED
MOLD HEATER
165 WATTS
ICE MAKER
HOLD
SWITCH
C
BLK
NO
NC
RED
LT. BLUE
THERMOSTAT
NO
NC
C
WATER FILL
SWITCH
BLU
C
SHUTOFF
SWITCH
YELLOW
LT. BLUE
ICE MAKER
P-4
WATER VALVE
P-2
SERVICE DATA SHEET
242321500
ICE & WATER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
Error Codes Special Modes
Display
FZ FF FZ FF
Interpretation Mode
-- OP Open FF Thermistor Manual Defrost d F + and - / same to deactivate
OP -- Open FZ Thermistor Display / Showroom 77 77 ٨ and - / Power-on-Reset (POR)
-- SH Shorted FF Ther mistor Sabbath Sb Sb ٧ and + / same to deactivate
Shorted FZ Thermistor System Diagnostic No FF or FZ dis-
SH --
SY CF
SY CE
UI to Main Control
Board communication
failure; on start up
UI Main Control
Board communication
error; after a period
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing
components.
• Determine whether failure is caused by the component, main control board or
wiring. Contact TID before replacing main control board.
• Refer to Service Manual for additional information.
in operation
SY EF Evaporator Fan
Failure
Variable Capacity Compressor (VCC) Diagnostics (select models)
If test 38 fails, diagnose as follows:
→ Check at the connector from the power cord
harness into the inverter board, located in
the machine compartment.
(PUR and WHT wires)
Is Inverter Board receiving 115 VAC
from power supply?
no
• Check voltage supply.
• Check and repair power
cord harness wiring and
connections.
→ Check at Inverter Board on
Compressor
(BLK and RED wires)
yes
Is Inverter Board receiving 10-15
VAC and 1-5 VDC from Main
Control Board?
no
→ Check at Main Control Board
(BLK/WHT and RED/BLK wires)
Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?
yes
Identify and repair damaged wires or
poor connections between Main Control
Board and Inverter Board.
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling: Remove cover by inserting screwdriver in notch at bot-
tom and prying cover from housing. Use screwdriver to rotate motor
gear counterclockwise until holding switch circuit is completed. All
components of ice maker should function to complete the cycle.
Water Fill Volume: The water fill adjustment screw will change the
fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is
102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the
fill volume must be checked.
Display Activate/Deactivate
(press for up to 10 sec. simultaneously)
٨ and ٧/ + to deactivate
play, all UI LEDs on.
→ Remove inverter box from the
compressor and check resistance
across compressor winding pairs as
yes yes
shown.
Is resistance across all winding
pairs equal?
no
Replace Compressor and
Inverter Board.
no
Replace Main Control Board.
VCC Resistance Check
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
→ Check connections from Inverter
Board to Compressor
Are connections from Inverter
Board to Compressor intact?
no
Identify and repair damaged
wires or poor connections
between Inverter Board and
Compressor.
Replace Inverter Board
yes
System Diagnostic Mode
Activate:
Deactivate:
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air ow as appropriate to determine results of tests.
Test To activate test: Passing result
-- First Screen -- All LED lights on UI illuminated
-- Second Screen -- All segments on UI temperature displays illuminated
-- Third Screen -- Blank UI display, no lights illuminated, no shadowing; “-” and “+”
28 Dispenser Paddle Press disp. paddle “on” on UI when depressed; “off” when released
1* Standard
Compressor
2 Defrost Heater Set Defrost limit switch must be closed; verify “CL” in test 26.
3 FF Light Set With FF door open, FF lights on when “on”; off when “off”
8 Water Valve
(Dispenser)
9 FZ Light Set With FZ door open, FZ lights on when “on”, off when “off”
10 Auger Motor Set FF door must be closed.
11 Cube/Crush
Solenoid
41* Perfect Temp
Drawer (PTD)
12* VCC Condenser
Fan
38* VCC Compressor Set Compressor running when “on”; stopped when “off”
15 Evaporator Fan Set Fan running for minimum of 10 sec. when “LO” or “HI”; stopped when
36 Ice Chute Door Depress ice chute
22 Damper Set With inspection mirror, observe damper open when “OP”; closed when “CL”
23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open
24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open
26 Defrost Limit Switch Activates automati-
29 FF Thermistor
Mid-level
30 FZ Thermistor Activates automati-
33 Ambient Thermistor
@ Main Board
35* FF Thermistor
Upper-Level
34* Ambient Thermistor
@ UI
0- Firmware
Parameters
2- Main Board
Firmware
4- UI Firmware Set Displays digit sequence; record
Press ٨ and ٧ for up to 10 sec. simultaneously.
Press + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.
blinking on FF display side to show location.
Set Compressor running when “on”; stopped when “off”
Feel for heat from defrost heater when “on”.
If “OP” in test 26, heater will not activate.
Set FF door must be closed.
Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off”
Motor running when “on”; motor stopped when “off”
Set FF door must be closed. Do not leave solenoid in activated state.
Solenoid activated when “on”; deactivated when “off”
Set PTD UI illuminated when “on”, off when “off”
Set Fan running when “on”; stopped when “off”
“off”. Feedback failure if fan starts but runs less than 10 sec. Listen for
speed change from “LO” to “HI”.
“OP” on UI when manually opened; “CL” when closed. Or, using “power
door or set
on-off”, “OP” on UI when solenoid activated, “CL” when deactivated
“CL” on UI when closed; “OP” when open
cally
Activates automatically
UI shows temperature sensed by FF thermistor; pass if within 10°F of
temperature measured with gauge at mid-level FF thermistor location.
“OP-” if open; “SH-” if short
UI shows temperature sensed by FZ thermistor; pass if within 10°F of tempera-
cally
ture measured with gage at FZ thermistor location.
“OP” if open; “SH” if short
Activates automatically
UI shows temperature sensed at main board; pass if within +20°F/-
10°F of temperature measured with gauge at main board location.
“OP” if open; “SH” if short
Activates automatically
UI shows temperature sensed by upper level FF thermistor; pass if
within 10°F of temperature measured with gauge at upper-level FF
thermistor location. “OP¯” if open; “SH¯” if short
Activates automatically
UI shows temperature sensed at UI; pass if within +20°F/-10°F of temperature measured with gauge at UI location. “OP” if open; “SH” if short
Set Displays digit sequence; record
Set Displays digit sequence; record
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should
not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing
this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.