IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualied
repair personnel only. Untrained persons should not attempt to
make repairs due to the possibility of electrical shock. Disconnect
power cord before servicing this appliance.
IMPORTANT
If any green/yellow grounding wires are removed during servicing,
they must be returned to their original position and properly secured.
PERFORMANCE
Ambient Temperature 70ºF 90ºF
Operating Time 100% 100%
Freezer Temperature 4 to -4ºF 4 to -4ºF
Low Side Pressure (cut-in) - -
Low Side Pressure (cut-o)
-7.02 to -3.94
PSIG
High Side Pressure 35 to 37 PSIG 51 to 56 PSIG
Wattage 32W 46.6W
Amps 0.4 0.61
Base Voltage 115V 115V
Refrigerant Charge 50g 50g
-6.63 to -4.65
PSIG
SERVICE DATA SHEET
A14365701
AUTOMATIC DEFROST UPRIGHT
FREEZER - R600a
The defrost period will vary dependent on the heater on time,
with a maximum of 60 minutes. There is a 7 minute idle (drip
time) time after the heater turns o before the evaporator fan
and compressor will turn on. During the defrosting period a
temperature sensor monitors the evaporator temperature and the
main control board turns the defrost heater o after the frost on
the evaporator has melted.
IMPORTANT: PLEASE RETURN THIS SHEET TO
ITS ORIGINAL LOCATION.
Specications subject to change without notice.
For complete performance data by model, refer to
service manual. Options shown are not necessar-
SERVICE MODE DIAGNOSTIC TESTS
Allows technicians to step through available tests to diagnose individual
electrical circuits.
NOTE: There is a magnetic switch located in the bottom front of the cabinet
(beside the green power on indicator light) and a permanent magnet is located
in a holder in the bottom of the door that work together to sense when the door
is opened and closed.
To Enter
Service Mode:
To manually exit
service mode:
To activate
manual defrost:
• Open the door.
• Using a permanent magnet, activate the magnetic
switch 4 times within 2 seconds, holding the forth
activation against the magnetic switch until a long beep
is heard and the interior AC LED Light bulb turns on.
• Move the magnet away from the magnetic switch.
The internal light will turn o indicating the unit is in
service mode.
NOTE: When service mode is entered, the green
power on indicator light will remain on.
• Using the permanent magnet, activate the magnetic
switch 2 times to terminate the current test and
activate the next test. Two beeps will sound conrming
the service mode has advanced to the next test.
• Test 1: Compressor and condenser fan:
The compressor and condenser fan turns ON as
soon as service mode is activated.
• Test 2: Defrost heater
NOTE: The defrost heater has a thermal fuse on
each side of the heater element. During the defrost
heater test the main board monitors the evaporator temperature and will automatically turn o
the defrost heater, if the evaporator temperature
exceeds a specied value to ensure the thermal
fuses are not permanently open circuited as they
are designed to operate.
• Test 3: AC LED bulb
CAUTION: DO NOT REPLACE THE AC LED BULB
WITH ANY BULB GREATER THAN 5 WATTS.
• Test 4: Evaporator Fan
• Using a permanent magnet, activate the magnetic
switch 4 times in 2 seconds, holding the forth activa-
tion against the magnetic switch until a long beep is
heard and the interior AC LED Light bulb turns on. The
unit will restart in normal operating mode.
• Unplug the unit from power and plug it back in to
power. The unit will restart in normal operating mode.
• The unit will automatically exit service mode if no
magnetic switch activation is detected after 10 minutes. The unit will restart in normal operating mode.
• Using a permanent magnet, activate the magnetic switch
5 times in 2 seconds, holding the fth activation against
the magnetic switch until ve short beeps are heard.
• The unit can enter in manual defrost only during
normal operating mode.
• The unit will not enter in manual defrost if already
in defrost mode.
• The unit will not enter manual defrost if the tem-
perature control knob is in the OFF position.
• The defrost heater has a thermal fuse on each side of
the heater element. During manual defrost, the main
board monitors the evaporator temperature and will
automatically turn o the defrost heater if the evaporator temperature exceeds a specied value to ensure
the thermal fuses are not permanently open circuited
as they are designed to operate.