Frigidaire FFAP5033W1 User Manual

A l l about the
Use & Care
of your
Important Safety Instructions
..............................................................
Location
How It Works Dehumidifier Features
Operating Instructions......................................... 4-9
......................................................33
Dehumidifier
TABLE OF CONTENTS
Care And Cleaning...............................................10
Storage .............................................................. 10
Normal Sounds
Before You Call ................................................... 12
4..........................................
Major Appliance Limited Warranty ........................ 13
11....................................................
16120100A12915
www.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352
Important Safety Instructions
NOTE:
This USE & CARE MANUAL provides specific operating instructions for your model. Use the dehumidifier only as instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance.
WARNING
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
Grounding type wall receptacle
Power supply cord with 3-prong grounding plug
Do not, under any circumstances, cut, remove, or bypass the grounding prong.
WARNING
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings. Discard water from bucket. Water is not potable and cannot be used for drinking.
For Your Safety
WARNING
For your safety and protection, this dehumidifier is equipped with a three-prong grounding plug on the power cord. Do not, under any circumstances, cut or remove the round ground prong from the plug.
Your dehumidifier must be plugged directly into a properly grounded and polarized three-prong receptacle. lf the wall receptacle you intend to use will not accept a three-prong plug, or if you are not sure the outlet is adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper outlet according to the National Electrical Code and applicable local codes and ordinances. Do not use an extension cord or an adapter plug.
Never unplug the dehumidifier by pulling on the power cord. Always grip the plug firmly and pull straight out from the receptacle.
Do not pinch, bend, or knot the power cord.
Electrical Information
WARNING
Destroy the carton, plastic bags, and any packing materials immediately after the dehumidifier is unpacked. Children should never use these items for play. Do not leave children unattended in an area where the appliance is operating. Do not allow them to sit or stand on the appliance. 7KLVDSSOLDQFHLVQRWLQWHQGHGIRUXVHE\SHUVRQVLQFOXGLQJFKLOGUHQZLWKUHGXFHGSK\VLFDOVHQVRU\RUPHQWDOFDSDELOLWLHVRUODFNRIH[SHULHQFH
and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
&KLOGUHQVKRXOGEHVXSHUYLVHGWRHQVXUHWKDWWKH\GRQRWSOD\ZLWKWKHDSSOLDQFH
Child Safety Precautions
SAFETY PRECAUTIONS
This dehumidifier contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs. Do not insert or place fingers or objects into the air discharge area or back grille of the unit. Do not start or stop the dehumidifier by unplugging the power cord or turning off the power at the electrical box. Do not cut or damage the power cord. Do not pull on the power cord. If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer. In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized Electrolux servicer. Do not operate the dehumidifier with wet hands. Do not drink any water from the dehumidifier.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The appliance shall be installed in accordance with national wiring regulations.
DANGER! Avoid Serious Injury or Death
SAFETY PRECAUTIONS
Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups. Do not climb on or place objects on the unit. Do not hang objects off the unit. Do not place containers with liquids on the unit. Turn off the dehumidifier at the power source when it will not be used for an extended period of time. Operate the unit with air filter in place. Do not block or cover the intake grille, discharge area and outlet ports. Ensure that any electrical/electronic equipment is one yard away from the unit. Do not use or store flammable gases near the unit.
2019 Electrolux Home Products, Inc. All rights reserved.
CAUTION! Avoid Injury or damage to the unit or other property
2
Location & How It Works
Location
Do not Block at least 24"
12"
How It Works
Wiring Diagram
Selecting a Location
IMPORTANT:
1. Dehumidifier must be operated in an enclosed area to be most effective. Close all doors, windows, and other outside openings to the room. The effectiveness of the dehumidifier depends on the rate at which new moisture-laden air enters the room.
2. Place dehumidifier in a location that does not restrict the airflow of the air intake and air outlet.
3. A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. lt may be necessary to install a second dehumidifier in the enclosed area for satisfactory drying.
4. The dehumidifier must be installed on a level floor that will support it with a full bucket of water.
12"
5. There should be a minimum of 12 inches clearance around the dehumidifier. The unit will produce heat while in operation and should not be operated in an enclosed small space like a closet.
When the unit is started, the fan begins to pull moisture-laden air across the dehumidifying coils. The coils condense or draw moisture from the air, and air flows through the air outlet louvers into the room as dry, warm air. Moisture removed from air is collected in a bucket on the front of the dehumidifier.
The unit is designed to operate between 41 °F (5 °C), and 89 °F (32 °C). The unit will not work properly if the temperature is out of this temperature range, or the performance of the unit will fall greatly.
The "Compressor" circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping.
Make sure the tank is fitted correctly otherwise unit will not turn on.
16020100001654
Notes:
This symbol indicates the element is optional, the actual shape shall prevail
COMP.
CAPACITOR
BLUE
BLUE
BLACK
3803
BLACK(or BLUE)
COMP.
OverLoad Protector
RED
Y/G
M
S
WHITE(OR BLUE OR BLACK)(N)
Y/G(or GREEN)
POWER
BLACK(OR BROWN OR RED)(L)
Notes:
Display and Fan's conntors must be match the actual indicates.
BLUE
FAN
CAPACITOR
~
OPTIONAL
CN2
,21
M
C
DC POWER BOARD
RED
BLACK
Y/G
BROWN
FAN
Y/G
CN1
RED
WHITE
BLACK(or BLUE)
P4
CN4
P9 P6
MAIN BOARD
P10
P7
P8
RED
TOP
M
STEP
TOUCH/LIGHT
PANEL
WIFI
HUMI.
WATER
PIPE
WIFI
SENSOR
SWITCHTEMP.
CN10
CN3
CN1
CN2
(or CN6/CN6A/CN6B/CN6C/CN10)
CN14
P1
P2
13
3 1
POWER BOARD
CN1
CN5
CN11
CN12
CN5
SWITCH
CN7
CN2
DISPLAY BOARD
CN10
(or CN13)
SWITCH
CN6B
CN15
12
1 2
2019 Electrolux Home Products, Inc. All rights reserved.
3
Dehumidifier Features & Operating Instructions
Dehumidifier Features
CHECK FILTER
RESET BUTTON
ELECTRONIC CONTROL
Before you begin, thoroughly familiarize yourself with the control panel and all its functions (as shown below).
BUCKET FULL
INDICATOR
SETS
TIMER
ADJUSTS
HUMIDITY
Operating Instructions
Allow the unit to reach room temperature before operating. To begin operating the dehumidifier, follow these steps:
NOTE:
Unit must be upright for one hour prior to operating.
1. Plug the power cord into a properly grounded 115 volt AC outlet.
DISPLAYS
HUMIDITY
SETS FAN
SPEED
TURNS UNIT
ON OR OFF
PUMP
FEATURE
NOTE:
If the "BUCKET FULL" light is on, remove the bucket and re-install to reset the float switch.
2019 Electrolux Home Products, Inc. All rights reserved.
4
Loading...
+ 9 hidden pages