Frigidaire FAQG7021LW, FAQG7111LW, FAQE7021LB, FAQE7011LB Wiring Diagram

Dryer Tech Data Sheet

This information is intended for Qualified Technicians Only.

CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING

Please Return This Sheet to its Envelope in the Product for Future Reference

READING ERROR CODES

1.Turn knob to third position from the left.

2.Press and hold SELECT and CANCEL simultaneously for six seconds. The buzzer will sound one time.

3.Immediately press and hold SELECT and CANCEL for six seconds. The control will enter Field Test Mode, the buzzer will sound three times, and the digit display will alternate between "Fld" and the firmware revision number (ex. "r03").

4.Rotate the cycle selector knob two turns clockwise. The error code will appear in the digit display.

Troubleshoot problem by using chart below.

To move on to the next code, press the Options button.

To clear code, press the Select button. Code will be cleared when mode is exited.

To exit this mode, simultaneously press and hold the Select and Cancel buttons for 6 seconds.

Error Code

Label

Description

Solution

E10

General EEPROM

Problem with communication

Clear code, exit mode and start dryer. If problem persists, replace electronic

 

Fault

between EEPROM and the

control.

 

 

microprocessor.

 

E11

Checksum Error

Problem with communications or

Clear code, exit mode and start dryer. If problem persists, replace electronic

 

 

memory did not check, one has

control.

 

 

become corrupted.

 

E12

Non fatal R/W

Problem reading or writing to the

Clear code, exit mode and start dryer. If problem persists, replace electronic

 

error

memory or input/output.

control.

E24

Control NTC Short

Control thermistor or its wiring is

Remove wires from control thermistor. Measure resistance of thermistor. If

 

Circuit

shorted.

reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (±

 

 

 

10%), check wiring between thermistor and electronic control. If good,

 

 

 

replace electronic control.

E25

Control NTC Open

Control thermistor or its wiring is

Remove wires from control thermistor. Measure resistance of thermistor. If

 

Circuit

open.

reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (±

 

 

 

10%), check wiring between thermistor and electronic control. If good,

 

 

 

replace electronic control.

E4A

Program Timeout

The drying time has exceeded

Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes.

 

Fault

program time for that cycle.

Position cycle selector to NORMAL, temperature selector to HIGH HEAT

 

 

 

and touch START. Check for anything that would extend dry times such as:

 

 

 

no heat, restricted vent, blower fan blade broken or loose, dryer installed in

 

 

 

closet with solid door, or bad connection in moisture sensor bar circuit or

 

 

 

dirty bars. If dryer operates normally but code returns, replace electronic

 

 

 

control.

E5B

Heater Fault (no

Temperature reading of control

Position cycle selector to NORMAL, temperature selector to HIGH HEAT

 

heating)

thermistor has not changed in a

and touch START. Measure voltage across terminals on relay RL2 (heater

 

 

certain amount of time.

relay) on electronic control. If meter reads 240V on electric models and

 

 

 

120V on gas models, replace electronic control. If meter reads zero, remove

 

 

 

power from dryer. Disconnect wire going to NO terminal on the relay RL2.

 

 

 

Reconnect power and measure voltage drop between terminal COM on

 

 

 

relay RL2 and neutral. If meter reads zero, wire between incoming line and

 

 

 

relay RL2 is open. If meter reads 120V, check the rest of the heater circuit.

E68

Key (button) Struck

One of the keys (buttons) is stuck

Enter function test mode and perform key (button) test to determine which

 

Fault

closed (active).

button is at fault. Carefully free the and perform the test again. If button is

 

 

 

free but the key struck code still exists, replace electronic control.

 

 

 

 

E8C

Too many trips in a

The safety (high limit) thermostat

Check for blocked lint filter, blocked exhaust, air leaks around air duct,

 

period of time.

has tripped too many times within

broken blower fan blades, worn or loose drum seals, dryer installed in closet

 

 

a certain period of program time.

with solid doors or door seal not correctly seated.

 

 

 

 

EAF

Watch Dog Reset

Microcontroller has been reset by

Clear code, exit mode and start dryer. If problem persists, replace electronic

 

 

internal Watchdog timer.

control.

 

 

 

 

NOTE: During normal operation, the display may show: “LOC” - control lock is activated.

PAU” - cycle has been interrupted.

137312700B (1202)

FUNCTION TEST SEQUENCE

1.Turn knob to sixth position from the left.

2.Press and hold SELECT and CANCEL simultaneously for six seconds. The buzzer will sound one time.

3.Immediately press and hold OPTIONS and CANCEL simultaneously for two seconds. The control will enter test mode, the buzzer will sound three times and all LEDs will rapidly flash.

After entering the test mode, the cycle selector knob can now be rotated to select the following tests:

Rotate the cycle selector knob clockwise from the starting position:

0 turns:

All LEDs will flash.

1 turn:

Drive motor runs; heat source is on. Drying LED is lit. “H” and the control thermistor reading will toggle

 

back and forth in the display.

2 turns:

Drive motor runs; heat source is off. Cool Down LED is lit and “AF” (Air Fluff) is displayed.

3 turns:

Drive motor runs; heat source is off. Drying and Cool Down LEDs are lit and numbers appear in the

 

display showing moisture sensor readings. Opening the door (press in on door switch plunger) and placing

 

a finger on the both moisture sense bars at the same time will make the numbers decrease. In controls that

 

do not have a digit display, the More Dry LED should be ON. Opening the door (press in on door switch

 

plunger) and placing a finger on the both moisture sense bars at the same time will make the Damp LED

 

come on.

4 turns:

Drive motor runs; heat source is off.

 

Key test:

 

a. When the Temperature key is pressed, all the temperature LEDs should light.

 

b. When the Dryness key is pressed, all the dryness level LEDs should light.

 

c. When the Options or Select key is pressed, all the Option LEDs should light.

 

d. When the Start/Pause key is pressed, all the cycle status LEDs should light.

 

e. When the Cancel key is pressed, all the cycle status LED’s should light.

5 turns:

Drive motor runs; heat source is off. Cool Down LED is lit. Control thermistor reading is displayed.

6 turns:

Drive motor runs; heat source is on. Drying LED is lit. Control thermistor reading is displayed.

7-11 turns:

All LEDs will flash

To EXIT test mode, press and hold the Select and Cancel buttons simultaneously for 6 seconds or disconnect power from dryer. Dryer will be reset for regular operation.

Feuille de données techniques de sécheuse

Ces renseignements ne s’adressent qu’à des techniciens qualifiés.

ATTENTION : DÉBRANCHEZ L’ALIMENTATION ÉLECTRIQUE AVANT D’EFFECTUER TOUT ENTRETIEN

Replacez cette feuille dans son enveloppe dans l’appareil pour référence ultérieure.

AFFICHER LES CODES D'ERREUR

1.Tournez le bouton jusqu'à la troisième position à partir de la gauche.

2.Maintenez simultanément enfoncés les boutons SELECT (Sélectionner) et CANCEL (Annuler) pendant 6 secondes. La sonnerie sonnera une fois.

3.Tout de suite après la sonnerie, appuyez simultanément sur les boutons SELECT (Sélectionner) et CANCEL (Annuler) et maintenez-les enfoncés pendant 6 secondes. Le tableau de commande entrera en mode Field Test (Essai pratique), la sonnerie sonnera 3 fois et l'afficheur fera alterner l'abréviation « Fld » et le numéro de révision du

microgiciel (ex. : « r03 »).

4.Tournez le bouton de sélecteur de programme deux tours vers la droite. Le code d'erreur apparaîtra dans l'afficheur.

Vérifier le problème en utilisant le tableau ci-dessous.

Pour passer au code suivant, appuyez sur le bouton Options.

Pour annuler un code, appuyez sur le bouton Sélectionner. Le code est annulé lorsqu’on quitte le mode.

Pour quitter ce mode, appuyez simultanément sur les boutons Sélectionner et Annuler et tenez-les enfoncés durant 6 secondes.

Code d’erreur

Étiquette

Description

Solution

E10

Défectuosité

Problème de communication entre

Annulez le code, quittez le mode et démarrez la sécheuse. Si le problème

 

générale du

le EEPROM et le

persiste, remplacez la commande électronique.

 

EEPROM.

microprocesseur.

 

E11

Erreur de total de

Problème de communication ou la

Annulez le code, quittez le mode et démarrez la sécheuse. Si le problème

 

contrôle

mémoire ne peut être vérifiée, l’un

persiste, remplacez la commande électronique.

 

 

ou l’autre est altéré.

 

E12

Erreur non fatale

Problème d’écriture ou de lecture

Annulez le code, quittez le mode et démarrez la sécheuse. Si le problème

 

R/W

de la mémoire

persiste, remplacez la commande électronique.

E24

Commande CTN

La commande de la thermistance

Démontez les câbles de la commande de la thermistance. Mesurez-en la

 

en court-circuit

ou son câblage est en court-

résistance. Si la lecture n’est pas de 50 K (± 10%), remplacez la

 

 

circuit.

thermistance. Si la lecture est de 50 K (± 10%), vérifiez le câblage entre la

 

 

 

thermistance et la commande électronique. Si celui-ci est bon, remplacez la

 

 

 

commande électronique.

E25

Le circuit de la

La commande de la thermistance

Démontez les câbles de la commande de la thermistance. Mesurez-en la

 

commande NTC

ou son câblage est ouvert.

résistance. Si la lecture n’est pas de 50 K (± 10%), remplacez la

 

est ouvert

 

thermistance. Si la lecture est de 50 K (± 10%), vérifiez le câblage entre la

 

 

 

thermistance et la commande électronique. Si celui-ci est bon, remplacez la

 

 

 

commande électronique.

E4A

Défectuosité de

La durée de séchage a excédé la

Appuyez sur les boutons Pause Annuler (Pause Cancel) et Sélectionner

 

temps d’arrêt du

durée du programme pour ce

(Select) durant 6 secondes pour quitter les modes test. Placez le sélecteur

 

programme

cycle.

de cycle à Normal, le sélecteur de température à Chaleur maximum (High

 

 

 

Heat) et appuyez sur Démarrer (Start). Vérifiez tout ce qui est susceptible

 

 

 

de prolonger la durée de séchage comme l’absence de chaleur, un évent

 

 

 

obstrué, une pale de soufflerie brisée ou relâchée, la sécheuse installée

 

 

 

dans une armoire avec une porte pleine ou mauvaise connexion dans le

 

 

 

circuit de la barre de captage d’humidité ou barres sales. Si la sécheuse

 

 

 

fonctionne normalement mais que les codes reviennent, remplacez la

 

 

 

commande électronique.

E5B

Défectuosité de la

La lecture de température de la

Placez le sélecteur de cycle à Normal, le sélecteur de température à

 

chaufferette

commande de la thermistance n’a

Chaleur maximum et appuyez sur Démarrer. Mesurez la tension entre les

 

(absence de

pas changé durant un certain laps

bornes sur le relais RL2 (relais de la chaufferette) de la commande

 

chaleur)

de temps.

électronique. Si la lecture des modèles électriques est 240 V et que celle

 

 

 

des modèles à gaz est 120 V, remplacez la commande électronique. Si la

 

 

 

lecture est zéro, coupez l’alimentation de la sécheuse. Débranchez le câble

 

 

 

allant de la borne NO du relais RL2. Ré-alimentez et mesurez la baisse de

 

 

 

tension entre la borne COM sur le relais RL2 et le neutre. Si la lecture est

 

 

 

zéro, le câble entre le circuit d’entrée et le relais RL2 est ouvert. Si la

 

 

 

lecture est 120V, vérifiez le reste du circuit de la chaufferette.

E68

Défectuosité de

L’une des touches (boutons) est

Entrez le mode test de la fonction et effectuez un test de toucher (bouton)

 

bouton (touche)

coincée en position active.

pour localiser le bouton défectueux. Dégagez prudemment et effectuez de

 

coincé.

 

nouveau le test. Si le bouton est dégagé mais que le code de touche

 

 

 

coincée est toujours présent, remplacez la commande électronique.

E8C

Trop de

Le thermostat de sécurité (limite

Vérifiez si le filtre à charpie est obstrué, si une évacuation est obstruée, s’il

 

déclenchements

supérieure) déclenche trop

existe une fuite d’air autour du conduit d’évacuation, des pales de

 

durant un laps de

souvent durant une certaine

ventilateur brisées, des joints d’étanchéité du tambour usés ou lâches, et

 

temps.

période de durée du programme.

toute sécheuse installée dans une armoire avec des portes pleines ou un

 

 

 

joint de porte incorrectement fixé.

EAF

Remise à zéro de

Le microcontrôleur a été remis à

Annulez le code, quittez le mode et démarrez la sécheuse. Si le problème

 

la minuterie de

zéro par la minuterie de

persiste, remplacez la commande électronique.

 

surveillance

surveillance.

 

137312700A 1003

Loading...
+ 5 hidden pages