Dryer Tech Data Sheet
This information is intended for Qualified Technicians Only.
CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING
Please Return This Sheet to its Envelope in the Product for Future Reference
READING ERROR CODES
1.Turn knob to third position from the left.
2.Press and hold SELECT and CANCEL simultaneously for six seconds. The buzzer will sound one time.
3.Immediately press and hold SELECT and CANCEL for six seconds. The control will enter Field Test Mode, the buzzer will sound three times, and the digit display will alternate between "Fld" and the firmware revision number (ex. "r03").
4.Rotate the cycle selector knob two turns clockwise. The error code will appear in the digit display.
Troubleshoot problem by using chart below.
To move on to the next code, press the Options button.
To clear code, press the Select button. Code will be cleared when mode is exited.
To exit this mode, simultaneously press and hold the Select and Cancel buttons for 6 seconds.
Error Code |
Label |
Description |
Solution |
E10 |
General EEPROM |
Problem with communication |
Clear code, exit mode and start dryer. If problem persists, replace electronic |
|
Fault |
between EEPROM and the |
control. |
|
|
microprocessor. |
|
E11 |
Checksum Error |
Problem with communications or |
Clear code, exit mode and start dryer. If problem persists, replace electronic |
|
|
memory did not check, one has |
control. |
|
|
become corrupted. |
|
E12 |
Non fatal R/W |
Problem reading or writing to the |
Clear code, exit mode and start dryer. If problem persists, replace electronic |
|
error |
memory or input/output. |
control. |
E24 |
Control NTC Short |
Control thermistor or its wiring is |
Remove wires from control thermistor. Measure resistance of thermistor. If |
|
Circuit |
shorted. |
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± |
|
|
|
10%), check wiring between thermistor and electronic control. If good, |
|
|
|
replace electronic control. |
E25 |
Control NTC Open |
Control thermistor or its wiring is |
Remove wires from control thermistor. Measure resistance of thermistor. If |
|
Circuit |
open. |
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± |
|
|
|
10%), check wiring between thermistor and electronic control. If good, |
|
|
|
replace electronic control. |
E4A |
Program Timeout |
The drying time has exceeded |
Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes. |
|
Fault |
program time for that cycle. |
Position cycle selector to NORMAL, temperature selector to HIGH HEAT |
|
|
|
and touch START. Check for anything that would extend dry times such as: |
|
|
|
no heat, restricted vent, blower fan blade broken or loose, dryer installed in |
|
|
|
closet with solid door, or bad connection in moisture sensor bar circuit or |
|
|
|
dirty bars. If dryer operates normally but code returns, replace electronic |
|
|
|
control. |
E5B |
Heater Fault (no |
Temperature reading of control |
Position cycle selector to NORMAL, temperature selector to HIGH HEAT |
|
heating) |
thermistor has not changed in a |
and touch START. Measure voltage across terminals on relay RL2 (heater |
|
|
certain amount of time. |
relay) on electronic control. If meter reads 240V on electric models and |
|
|
|
120V on gas models, replace electronic control. If meter reads zero, remove |
|
|
|
power from dryer. Disconnect wire going to NO terminal on the relay RL2. |
|
|
|
Reconnect power and measure voltage drop between terminal COM on |
|
|
|
relay RL2 and neutral. If meter reads zero, wire between incoming line and |
|
|
|
relay RL2 is open. If meter reads 120V, check the rest of the heater circuit. |
E68 |
Key (button) Struck |
One of the keys (buttons) is stuck |
Enter function test mode and perform key (button) test to determine which |
|
Fault |
closed (active). |
button is at fault. Carefully free the and perform the test again. If button is |
|
|
|
free but the key struck code still exists, replace electronic control. |
|
|
|
|
E8C |
Too many trips in a |
The safety (high limit) thermostat |
Check for blocked lint filter, blocked exhaust, air leaks around air duct, |
|
period of time. |
has tripped too many times within |
broken blower fan blades, worn or loose drum seals, dryer installed in closet |
|
|
a certain period of program time. |
with solid doors or door seal not correctly seated. |
|
|
|
|
EAF |
Watch Dog Reset |
Microcontroller has been reset by |
Clear code, exit mode and start dryer. If problem persists, replace electronic |
|
|
internal Watchdog timer. |
control. |
|
|
|
|
NOTE: During normal operation, the display may show: “LOC” - control lock is activated.
“PAU” - cycle has been interrupted.
137312700B (1202)
FUNCTION TEST SEQUENCE
1.Turn knob to sixth position from the left.
2.Press and hold SELECT and CANCEL simultaneously for six seconds. The buzzer will sound one time.
3.Immediately press and hold OPTIONS and CANCEL simultaneously for two seconds. The control will enter test mode, the buzzer will sound three times and all LEDs will rapidly flash.
After entering the test mode, the cycle selector knob can now be rotated to select the following tests:
Rotate the cycle selector knob clockwise from the starting position:
0 turns: |
All LEDs will flash. |
1 turn: |
Drive motor runs; heat source is on. Drying LED is lit. “H” and the control thermistor reading will toggle |
|
back and forth in the display. |
2 turns: |
Drive motor runs; heat source is off. Cool Down LED is lit and “AF” (Air Fluff) is displayed. |
3 turns: |
Drive motor runs; heat source is off. Drying and Cool Down LEDs are lit and numbers appear in the |
|
display showing moisture sensor readings. Opening the door (press in on door switch plunger) and placing |
|
a finger on the both moisture sense bars at the same time will make the numbers decrease. In controls that |
|
do not have a digit display, the More Dry LED should be ON. Opening the door (press in on door switch |
|
plunger) and placing a finger on the both moisture sense bars at the same time will make the Damp LED |
|
come on. |
4 turns: |
Drive motor runs; heat source is off. |
|
Key test: |
|
a. When the Temperature key is pressed, all the temperature LEDs should light. |
|
b. When the Dryness key is pressed, all the dryness level LEDs should light. |
|
c. When the Options or Select key is pressed, all the Option LEDs should light. |
|
d. When the Start/Pause key is pressed, all the cycle status LEDs should light. |
|
e. When the Cancel key is pressed, all the cycle status LED’s should light. |
5 turns: |
Drive motor runs; heat source is off. Cool Down LED is lit. Control thermistor reading is displayed. |
6 turns: |
Drive motor runs; heat source is on. Drying LED is lit. Control thermistor reading is displayed. |
7-11 turns: |
All LEDs will flash |
To EXIT test mode, press and hold the Select and Cancel buttons simultaneously for 6 seconds or disconnect power from dryer. Dryer will be reset for regular operation.
Feuille de données techniques de sécheuse
Ces renseignements ne s’adressent qu’à des techniciens qualifiés.
ATTENTION : DÉBRANCHEZ L’ALIMENTATION ÉLECTRIQUE AVANT D’EFFECTUER TOUT ENTRETIEN
Replacez cette feuille dans son enveloppe dans l’appareil pour référence ultérieure.
AFFICHER LES CODES D'ERREUR
1.Tournez le bouton jusqu'à la troisième position à partir de la gauche.
2.Maintenez simultanément enfoncés les boutons SELECT (Sélectionner) et CANCEL (Annuler) pendant 6 secondes. La sonnerie sonnera une fois.
3.Tout de suite après la sonnerie, appuyez simultanément sur les boutons SELECT (Sélectionner) et CANCEL (Annuler) et maintenez-les enfoncés pendant 6 secondes. Le tableau de commande entrera en mode Field Test (Essai pratique), la sonnerie sonnera 3 fois et l'afficheur fera alterner l'abréviation « Fld » et le numéro de révision du
microgiciel (ex. : « r03 »).
4.Tournez le bouton de sélecteur de programme deux tours vers la droite. Le code d'erreur apparaîtra dans l'afficheur.
Vérifier le problème en utilisant le tableau ci-dessous.
Pour passer au code suivant, appuyez sur le bouton Options.
Pour annuler un code, appuyez sur le bouton Sélectionner. Le code est annulé lorsqu’on quitte le mode.
Pour quitter ce mode, appuyez simultanément sur les boutons Sélectionner et Annuler et tenez-les enfoncés durant 6 secondes.
Code d’erreur |
Étiquette |
Description |
Solution |
E10 |
Défectuosité |
Problème de communication entre |
Annulez le code, quittez le mode et démarrez la sécheuse. Si le problème |
|
générale du |
le EEPROM et le |
persiste, remplacez la commande électronique. |
|
EEPROM. |
microprocesseur. |
|
E11 |
Erreur de total de |
Problème de communication ou la |
Annulez le code, quittez le mode et démarrez la sécheuse. Si le problème |
|
contrôle |
mémoire ne peut être vérifiée, l’un |
persiste, remplacez la commande électronique. |
|
|
ou l’autre est altéré. |
|
E12 |
Erreur non fatale |
Problème d’écriture ou de lecture |
Annulez le code, quittez le mode et démarrez la sécheuse. Si le problème |
|
R/W |
de la mémoire |
persiste, remplacez la commande électronique. |
E24 |
Commande CTN |
La commande de la thermistance |
Démontez les câbles de la commande de la thermistance. Mesurez-en la |
|
en court-circuit |
ou son câblage est en court- |
résistance. Si la lecture n’est pas de 50 K (± 10%), remplacez la |
|
|
circuit. |
thermistance. Si la lecture est de 50 K (± 10%), vérifiez le câblage entre la |
|
|
|
thermistance et la commande électronique. Si celui-ci est bon, remplacez la |
|
|
|
commande électronique. |
E25 |
Le circuit de la |
La commande de la thermistance |
Démontez les câbles de la commande de la thermistance. Mesurez-en la |
|
commande NTC |
ou son câblage est ouvert. |
résistance. Si la lecture n’est pas de 50 K (± 10%), remplacez la |
|
est ouvert |
|
thermistance. Si la lecture est de 50 K (± 10%), vérifiez le câblage entre la |
|
|
|
thermistance et la commande électronique. Si celui-ci est bon, remplacez la |
|
|
|
commande électronique. |
E4A |
Défectuosité de |
La durée de séchage a excédé la |
Appuyez sur les boutons Pause Annuler (Pause Cancel) et Sélectionner |
|
temps d’arrêt du |
durée du programme pour ce |
(Select) durant 6 secondes pour quitter les modes test. Placez le sélecteur |
|
programme |
cycle. |
de cycle à Normal, le sélecteur de température à Chaleur maximum (High |
|
|
|
Heat) et appuyez sur Démarrer (Start). Vérifiez tout ce qui est susceptible |
|
|
|
de prolonger la durée de séchage comme l’absence de chaleur, un évent |
|
|
|
obstrué, une pale de soufflerie brisée ou relâchée, la sécheuse installée |
|
|
|
dans une armoire avec une porte pleine ou mauvaise connexion dans le |
|
|
|
circuit de la barre de captage d’humidité ou barres sales. Si la sécheuse |
|
|
|
fonctionne normalement mais que les codes reviennent, remplacez la |
|
|
|
commande électronique. |
E5B |
Défectuosité de la |
La lecture de température de la |
Placez le sélecteur de cycle à Normal, le sélecteur de température à |
|
chaufferette |
commande de la thermistance n’a |
Chaleur maximum et appuyez sur Démarrer. Mesurez la tension entre les |
|
(absence de |
pas changé durant un certain laps |
bornes sur le relais RL2 (relais de la chaufferette) de la commande |
|
chaleur) |
de temps. |
électronique. Si la lecture des modèles électriques est 240 V et que celle |
|
|
|
des modèles à gaz est 120 V, remplacez la commande électronique. Si la |
|
|
|
lecture est zéro, coupez l’alimentation de la sécheuse. Débranchez le câble |
|
|
|
allant de la borne NO du relais RL2. Ré-alimentez et mesurez la baisse de |
|
|
|
tension entre la borne COM sur le relais RL2 et le neutre. Si la lecture est |
|
|
|
zéro, le câble entre le circuit d’entrée et le relais RL2 est ouvert. Si la |
|
|
|
lecture est 120V, vérifiez le reste du circuit de la chaufferette. |
E68 |
Défectuosité de |
L’une des touches (boutons) est |
Entrez le mode test de la fonction et effectuez un test de toucher (bouton) |
|
bouton (touche) |
coincée en position active. |
pour localiser le bouton défectueux. Dégagez prudemment et effectuez de |
|
coincé. |
|
nouveau le test. Si le bouton est dégagé mais que le code de touche |
|
|
|
coincée est toujours présent, remplacez la commande électronique. |
E8C |
Trop de |
Le thermostat de sécurité (limite |
Vérifiez si le filtre à charpie est obstrué, si une évacuation est obstruée, s’il |
|
déclenchements |
supérieure) déclenche trop |
existe une fuite d’air autour du conduit d’évacuation, des pales de |
|
durant un laps de |
souvent durant une certaine |
ventilateur brisées, des joints d’étanchéité du tambour usés ou lâches, et |
|
temps. |
période de durée du programme. |
toute sécheuse installée dans une armoire avec des portes pleines ou un |
|
|
|
joint de porte incorrectement fixé. |
EAF |
Remise à zéro de |
Le microcontrôleur a été remis à |
Annulez le code, quittez le mode et démarrez la sécheuse. Si le problème |
|
la minuterie de |
zéro par la minuterie de |
persiste, remplacez la commande électronique. |
|
surveillance |
surveillance. |
|
137312700A 1003