Frigidaire FFMV162LQ, FFMV162LS, FFMV162LW, FFMV164LS, FMV152KB Technical Sheet

...
MICROWAVE OVEN TECH SHEET
CAUTION
Disconnect from Electrical Supply Before Servicing Unit
PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID PROSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
A. Do not operate or allow the oven to be
B. Make the following safety checks on all
ovens to be serviced before activating the Magnetron or other microwave source, and make repairs as necessary.
1. Interlock operating.
2. Proper door closing.
3. Seal and sealing surfaces ( Arcing, wear and other damage.)
4. Damage to or loosening of hinges
and latch.
5. Evidence of dropping or abuse.
C. Before turning on microwave power for
any service test or inspection within the microwave generating compartments.
check the magnetron. Waveguide or transmission line. And cavity for proper alignment, integrity and connection.
D. Any detective or mis-adjusted
components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired. replaced. or adjusted by producers.
designed in this manual before the oven Is released to the owner.
E. A microwave leakage check to v erify
Compliance with the Federal performance Standard should be performed on each oven prior to release to the owner.
F. Do not attempt to operate the oven if the
door glass is broken.
Parts Layout
Schematic Diagram
Warning : Power must be disconnected before servicing this appliance
Wiring Diagram
Warning : Power must be disconnected before servicing this appliance
NOTE: Door is open
Made in china
MODEL NO. :
NOTE: For servicing replacement use 16GA,105 C thermoplastic covered wire
except for high voltage leads or as noted on special leads.
1
12
RD-5
BR-22
OG-18
GN-23
GY-26
BL-25
BK-24
WH-31
YW-32
BK-17 WH-15
T/TABLE MOTOR
FAN MOTOR
WH-16
YW-7
WH-15
OG-18
WH-16
BL-20 YW-6 BK-17
OVEN LAMP
GN-23
BL-20
YW-19 YW-21
COOKTOP LAMP
WH-12 BK-10
POWER RELAY
WH-30 GN-28 YW-29 OG-27 BL-25
VENT MOTOR
CAVITY THERMOSTAT
BK-2
BK-1
BK-2 BK-3
MGT THERMOSTAT
BOTTOM THERMOSTAT
BK-4
BK-3
GY-26 BK-24
HOOD THERMOSTATA
OG-27
WH-31
YW-32
DOOR SENSING SWITCH
YW-7
YW-6
PRIMARY SWITCH
BK-4
BK-8
MONITOR SWITCH
WH-11
WH-9
YW-29
GN-28
MOTOR CONDENSER
BK
WH
BK
WH
GND
NOISE FILTER
BK-1
WH-12
OUT IN
BK
WH
POWER CORD
WH-11
BK-10
WH-9
BK-8
H.V.TRANS
H.V.CAPACITOR
MGT TUBE
FA
F
H.V.DIODE
WH
RD
RD
RD
P C B
PK:PINK
GN:GREEN
BL:BLUE
YW:YELLOW
RD:RED BK:BLACK
GY:GREY
WH:WHITE
OG:ORANGE
BR:BROWN
GROUND HARNESS LEADS PARTS LEADS
OVEN THERMOSTAT
VENT MOTOR
MOTOR CONDENSER
NOISE FILTER
OVEN LAMP
H.V.CAPACITOR
MAGNETRON
H.V.TRANSFORMER
FAN MOTOR
HOOD THERMOSTAT
BOTTOM THERMOSTAT
PRIMARY SWITCH
DOOR SENSING SWITCH
MONITOR SWITCH
COOK TOP LAMPS
T/TABLE MOTOR
H.V.DIODE
MAGNETRON THERMOSTATA
VENT RELAY
HI (RY5)
7
VENT MOTOR
T.P.
LOW
(RY4)
ON
(RY3)
L.V.T
SUB
RELAY
(RELAY 1)
LAMP RELAY
1
8
HOOD THERMAL
CUT-OUT
(40/70)
9
MOTOR
CAPACITOR
6
COOKTOP LAMP
L
L
3
4
L
OVEN LAMP
120V
FAN MOTOR
FM
120V TURNTABLE MOTOR
TTM
12
POWER RELAY
(RELAY 2)
MAGNETRON
H.V. CAPACITOR
11
F
FA
H.V. TRANS
H.V.DIODE
22 BR
10 BK
8 BK
7 YW
18 OG
15 WH
16 WH
17 BK
6 YW20 BL
19 YW
21 YW
23 GN
29 YW
28 GN
30 WH
5 RD
26 GY
25 BL
24 BK
32 YW
31 WH
27 OG
SWITCH (BOTTOM)
SENSE
DOOR
CAVITY THERMAL CUT-OUT
(110/0)
MGT THERMAL
CUT-OUT
(1
6
0/
95
)
BOTTOM THERMAL
CUT-OUT
(1
2
0/
0
)
PK:PINK
GN:GREEN
BL:BLUE
YW:YELLOW
RD:RED
BK:BLACK
GY:GREY
WH:WHITE
OG:ORANGE
BR:BROWN
INTERLOCK ( UPPER)
PRIMARY
SINGLE PHASE
POWER SUPPLY :
ONLY
FILTER ASS'Y
FUSE
BK
WH
GN
GN
1 BK
2 BK
3 BK
4 BK
CONTROL P.W.B. ASS'Y
12 WH
11 WH
9 WH
MONITOR INTERLOOK SWITCH
3. Measure resistance .( ohm meter scale: Rx1000)
Filament winding Primary winding to ground
Primary winding Secondary winding
Transformer
from the outlet before removing the
Disconnect the power supply cord
7. Normal temperature rise for this model is 9.9 C to 10.3 C at ‘HIGH’. NOTE 1: Variations or errors in the test procedure will cause a variance in the temperature rise.
SWITCH
Component tests
Switch Chart
CHECK BY
DOOR
CAUTION MICROWAVE RADIATION
DOOR CLOSE
Primary Interlock
Disconnect the wires at the Primary Interlock Switch. Check from the common terminal to the normally opened terminal.
_
+
Door sensing Interlock
Disconnect the wires at the s ensing interlock Switch. Check from the common terminal and Normally closed terminal
_
+
Monitor Interlock
Disconnect the wires at the Monitor Switch. Check from the common terminal and Normally closed terminal .
+
_
( ) CONTINUITY ( ) NO CONTINUITY
_
+
DOOR OPEN
L
N
Primary Interlock Switch
Door Sensing Switch
Monitor Interlock Switch
DOOR CLOSE
L
N
Primary Interlock Switch
Door Sensing Switch
Monitor Interlock Switch
Note: These Diagrams are not intended to show a complete circuit, they represent the position of switches
during “DOOR OPEN” and “DOOR CLOSED”. (continuity checks only)
OUTPUT POWER OF MAGNETRON
PERSONNEL SHOULD NOT ALLOW EXPOSURE TO MICROWAVE RADIATION FROM MICROWAVE GENERATOR OTHER PARTS CONDUCTING MICROWAVE ENERGY.
The output power of the magnetron can be measured by performing a water temperature rise test. Equipment needed: * Two 1-liter cylindrical borosilicate glass vessel (Outside diameter 190 mm) * One glass thermometer with mercury column NOTE: Check line voltage under load. Low voltage will lower the magnetron output.
Make all temperature and time tests with accurate equipment.
1. Fill the one liter glass vessel with water.
2. Stir water in glass vessel with thermometer, and record glass vessel’s temperature (“T1”, 10 1 C).
+
_
3. After moving the water into another glass vessel, place it in the center of the cooki ng tray. Set the oven to high power and operate for 47 seconds exactly. ( 3 seconds included as a holding time of magnetron oscillation)
4. When heating is finished, stir the water again with the thermometer and measure the temperature ( “T2”).
5. Subtract T1 from T2. This will give you the water temperaturerise. ( T )
6. The output power is obtained by the following formula; Output = 4.187x1000x T+0.55xMcx(T2-T0)
42
45 : Heating Times (sec)
( 3 seconds included as a holding t ime of magnetron oscillation.)
4.187 : Coefficient for wate r 1000 : Water ( cc )
T : Temperature Rise (T2-T1)
T0 : Room Temperature
Mc : Cylindrical borosilicate glass weight
Additional power test should be made if temperature rise is marginal.
NOTE 2: Output power in watts is computed by multiplying the temperature rise (step 5) by a factor
of 91 times the of centigrade temperature.
WARNING
Personal injury/Product Hazard
outer cabinet from the unit. Discharge the high voltage capacitor and remove the lead wires from The primary winding of the high voltage transformer before conducting any of the following tests. Conduct all operation tests with 1 liter of water in the oven. Conduct a microwave energy test
after performing any test or repairs to the microwave. Check that all wire leads are in the Correct position before operating The microwave oven. Grasp wire connectors when removing the wire leads from microwave parts.
Failure to follow these instructions may result in electrical shock or other Personal injury or in product damage.
High voltage components
Components
Secondary Terminal
Filament Terminals
Primary Terminal
Magnetron
Cooling Fins
Capacitor
Diode
Some inexpensive Meters may indicate Infinite resistance in both directions
Ventilation Motor
Test
1. Remove wire leads.
2. Measure resistance .( ohm meter scale: Rx1)
Filament winding to ground
1. Remove wire leads. Install the magnetron seal in the correct position .Check that the seal is in good condition.
2. Measure resistance .( ohm meter scale: Rx1)
Filament winding
3. Measure resistance .( ohm meter scale: Rx1000)
Filament to chassis
1. Remove wire leads.
2. Measure resistance .( ohm meter scale: Rx1000)
Terminal to terminal
Terminal to case
1. Measure continuity. Forward .( ohm meter scale: Rx1000)
2. Measure continuity. Reverse .( ohm meter scale: Rx1000)
1. Remove wire leads.
2. Measure resistance .( ohm meter scale: Rx1) 2 level: White and Blue wire
Results
Approx. 0.334+2% ohm. Approx. 118.7+2% ohm. 0 ohm..
Normal: Infinite.
Normal: Infinite.
Normal: Less than 1 ohm
Normal: Infinite.
Normal: Momentarily indicates several
ohm, and then gradually returns to infinite.
Normal: Infinite.
Normal: Continuity. Abnormal: Infinite.
Normal: Infinite. Abnormal: Continuity.
Approximately 35.2 ohms
T/Table Motor
Fan Motor
Other component tests
1. Remove wire leads.
2. Measure resistance. ( ohm meter scale: Rx1000)
Normal: Approximately: 3.3k ohms
1. Remove wire leads.
2. Measure resistance. ( ohm meter scale: Rx1)
Normal: Approximately: 97.4 ohms
MODEL NO. :
p/n 316495069
(C)/FMV152K; C/FFMV162L;C/FFMV164L
(C)/FMV152K; C/FFMV162L;C/FFMV164L
Loading...