Friedrich P12sa Owner's Manual

ZoneAire® Compact
Portable Air Conditioner with Heat
OWNER’S MANUAL P08SA / P10SA / P12SA
TABLE OF C
Important Safety Guidelines ______________ 2
Introduction ___________________________ 3
Unpacking Instructions & Contents ________ 4
Parts ________________________________ 5
Display Functions ______________________ 6
Remote Control Functions _______________ 9
Drain Pipe ___________________________ 12
Maintenance & Cleaning _______________ 13
Installation __________________________ 14
Troubleshooting ______________________ 16
ONTENTS
98081002_02
IMPORTANT SAFETY GUIDELINES
IMPORTANT
Do not install and use your portable air conditioner unit before carefully reading this instruction guide.
Please retain this manual brochure for product warranty and future reference
CAUTION Operate this unit in an ambient of 89°F or less. The heating function of the unit should be operated
in an indoor ambient temperature between 44°F and 73°F.
Clean air lter periodically to enjoy the most efcient cooling.
When the unit is shut off, please wait at least 3.5 minutes before restarting; this is to prevent the compressor from being damaged.
This unit is for indoor cooling, heating and dehumidifying.
When turning on the unit, the fan will operate but the compressor will start up after the cooling
alarm ashes for three minutes. In heating function, the heating alarm will ash for
3.5 minutes before the compressor and fan start up.
If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in Table 1.
Tab le
1.
MODEL
P08SA, P10SA, P12SA
CIRCUIT
RATING
TIME
AMP VO LT
15
OR
DELAY
FUSE
125 5-15P
REQUIRED
WALL
RECEPTACLE
NEMA
NO.
2
INTRODUCTION
Congratulations on your purchase and welcome to Friedrich!
ZoneAire® Compact: PORTABLE AIR CONDITIONER
The Air Conditioner has been designed and manufactured to the highest standards of modern engineering.
Our product not only provides you a remote control to operate all of the functions easily and conveniently but
also includes the following benets:
3-IN-1 SYSTEM: Offers cooling, dehumidication and bonus heat for year-round and comfort.
Innovative design: One side offers cooling, simply turn the unit around and attach the hose for heating.
• Easy-roll casters.
• Built-in hose storage.
Dual, easy-access antimicrobial nylon lters
• Electronic control pad provides easy identifying icons for simplified user operation
24-hour programmable timer for cooling, heating and dehumidication modes
• Unique Sleep Control function – Increases temperature 2 degrees every 4 hours
• LCD remote control
conditioning
3
UNPACKING INSTRUCTIONS
UNPACKING INSTRUCTIONS
1. Place the unit in the correct upright position before unpacking.
2. Cut the two packing straps.
3. Slide the carton in an upward motion and it will release from the base.
4. Grip the carry handles located on either sides of the unit and carefully lift until it slides out of the foam
base.
5. Remove the hot air outlet to take out the exhaust hose and (upper/lower) hose adapters.
6. Install the exhaust hose on the unit before operating the unit.
CONTENTS
CONTENTS
1. Portable air conditioner unit
2. Remote control (1 pc)
3. A-type window kit
4. Upper/ Lower hose adapters
5. Joint tube
6. Exhaust hose (1 pc)
7. Batteries (2 pcs)
8. User Manual (1 pc)
4
PARTS
1. Control panel
2. Remote control receiver
3. Adjusting Dials
4. Adjustable air vent
5. Joint tube
6. Exhaust hose
7. Upside drain hole
8. Cool air inlet
9. Cool air lter
10. Hot air inlet
11. Hot air lter
12. Downside drain hole
5
DISPLAY FUNCTIONS
: LED DISPLAY
: POWER
: MODE
: TIMER
: SLEEP mode
1. FUNCTIONS Key Description:
POWER (On/ Off Key) :
- Standby mode (Default)
- Turn On/ Off the unit
- Turn on the unit, the indicator lights on.
- Turn of the unit to standby mode, the indicator lights off.
2. MODE (Functions switch key) : the switching cycle is Cooling (Default) > Dehumidifying > Heating,
and back to Cooling again.
COOLING/Heating/ Dehumidication Modes:
The indicator light turns blue for cooling, red for heating, and green for dehumidication> If the compressor shuts down, the indicator blinks. The display window shows setting temperature on screen.
3. TEMPERATURE REGULATION Knob (UP/Down)
- Rotate the dial in clockwise direction; the value will increase 1ºC/1ºF per scale. The maximum value is 30ºC/86ºF (25ºC/77ºF). Rotate the dial in a counter-clockwise direction to decrease the value 1ºC/1ºF per scale. The minimum value is 17ºC/63ºF(15ºC/59ºF).
- In DEHUMIDIFYING mode, the dial is inactive.
4. PROGRAMMABLE TIMER
- Press the key to activate the timer, the indicator lights on; press the key again to cancel the timer setting, the indicator light will turn off.
- While the unit is operating or in standby, press the key and rotate the dial in clockwise/ counter-clockwise direction to set the Auto-Off time from 0 to 24 hours.
- During the TIMER mode, press and hold the key for 1 second, the time increases continuously
- To set the time, press the key before rotating the dial . The display will ash the on/ off time during setting and show the time setting on screen.
6
DISPLAY FUNCTIONS
5. L.E.D. DISPLAY
The display indicates the current setting temperature or the timer setting. When the set temperature or
the timer is adjusted, the new setting is shown then the display returns the current set temperature.
The display is also used to show error codes should a fault occur, see TROUBLE SHOOTING.
6. FAN SPEED
Rotate the dial in clockwise direcon, the speed changes from F1 (Low) → F2 (Medium) → F3 (High) → AU (Auto)
Rotate the dial in counter-clockwise direcon, the speed changes backwards from AU (Auto) → F3 (High) → F2 (Medium) → F1 (Low) In COOLING mode, fan speeds are available from F1 (Low), F2 (Medium), and F3 (High) to AU (Auto). Default fan speed is in F2 (Medium) speed. Rotate the knob to F1 (Low) → F2 (Medium) → F3 (High) → AU (Auto) fan speed.
If “AUTO” is selected (During cooling funcon),”HIGH” or “MEDIUM” or “LOW” will be selected automacally
according to the dierence between seng temperature and ambient temperature.
7. TIMER MODE
TIMER scale: from 0 to 24 hours.
- Use the TIMER to set the Auto-O me during operang or in Stand-By mode
- While seng the TIMER, use the key or the dial is available to adjust to the desired me.
- With each press of the TIMER key, the value on the display will increase from”00”→”01”……→ to”24”
and back to “00” again.
- Set the Auto- On / Auto- O mer:
- Press the key to preset the Auto-O mer, and the display will ash the seng me. The display will
return to show operang mode aer 5 seconds.
- Press the key before the preset me to cancel the Auto-O mer, and the unit will be turned o directly.
- While seng the Auto-On mer, you can preset the funcons at the same me.
- Press the key to set the Auto-On mer. Aer seng up, the display shows the rest of me.
- Press the key before the preset me to cancel the Auto-On mer, and the unit will be turned on directly
- Aer seng up the Auto-On mer, the unit is sll available to be controlled or be switched to other funcons.
7
DISPLAY FUNCTIONS
8. SLEEP CONTROL FUNCTION
In “Sleep” mode, your unit will automacally go into low fan speed allowing the temperature to slowly dri up (in cooling) or down (in heang). See below:
- While in cooling mode, press the SLEEP key to set the temperature. It increases 2°F after an hour and at most increases 4°F after 2 hours.
- While in heating mode, press the SLEEP key to set the temperature. It decreases 2°F after hour and at most decreases 4°F after 2 hours.
- Press the SLEEP key again to cancel the seng.
9. ALARM
When the water tank is full,”E4” will be displayed on the display panel. To resume operaon, please remove the rubber cap of the drain hose to drain out the water rstly. The E4 warning will disappear aer draining, and then you can restart the unit by pressing the POWER key.
8
REMOTE CONTROL FUNCTIONS
Instruction for the operating keys:
When a remote control signal is transmitted, a transmission icon on the display ashes once, indicating the
signal has been transmitted.
9
REMOTE CONTROL FUNCTIONS
1. Transmission window
2. Liquid crystal display
3. Mode select key:
Select from among the three functions: cooling, heating and dehumidifying. The fast key function
indicates the above operating modes in a cycle when the key is pressed without being released.
However, the transmission icon will not appear until the key is released and the conrmed mode is
transmitted.
4. Setting keys for room temperature:
The set temperature will rise by 1°F when the key is pressed once and the set temperature will fall by 1°F when the key is pressed once. Both keys have the fast key function and can make the set temperature rise or fall continuously when the keys are pressed without release.
5. Power key:
When this key is pressed, the memorized modes and other information about temperature, speed,
direction of airow, sleep, etc., in the remote control will be transmitted to the unit and it will operate
correspondingly. When the key is pressed again, the main unit will stop immediately.
6. Sleep key
When this key is pressed, the air ow of the unit changes into sleep mode (low speed).
(1) Press “SLEEP” key, set sleep function; press again, and cancel sleep setting.
(2) The temperature will increase 2°F half an hour after setting sleep function, and will increase at most 4°F every two hours after that.
(3) When the main power supply is cut off, the sleep function setting will be cancelled
automatically.
(4) When you turn off the unit, sleep function setting will be cancelled automatically.
10
Loading...
+ 22 hidden pages