Do not install and use your portable air conditioner
unit before carefully reading this instruction guide.
Please retain this manual brochure for product
warranty and future reference
CAUTION
Operate this unit in an ambient of 89°F or less.
The heating function of the unit should be operated
in an indoor ambient temperature between 44°F
and 73°F.
Clean air lter periodically to enjoy the most
efcient cooling.
When the unit is shut off, please wait at least 3.5
minutes before restarting; this is to prevent the
compressor from being damaged.
This unit is for indoor cooling, heating and
dehumidifying.
When turning on the unit, the fan will operate
but the compressor will start up after the cooling
alarm ashes for three minutes.
In heating function, the heating alarm will ash for
3.5 minutes before the compressor and fan start
up.
If you have fuses, they should be of the time
delay type. Before you install or relocate this unit,
be sure that the amperage rating of the circuit
breaker or time delay fuse does not exceed the
amp rating listed in Table 1.
Tab le
1.
MODEL
P08SA, P10SA,
P12SA
CIRCUIT
RATING
TIME
AMPVO LT
15
OR
DELAY
FUSE
1255-15P
REQUIRED
WALL
RECEPTACLE
NEMA
NO.
2
INTRODUCTION
Congratulations on your purchase and welcome to Friedrich!
ZoneAire® Compact: PORTABLE AIR CONDITIONER
The Air Conditioner has been designed and manufactured to the highest standards of modern engineering.
Our product not only provides you a remote control to operate all of the functions easily and conveniently but
also includes the following benets:
• 3-IN-1 SYSTEM: Offers cooling, dehumidication and bonus heat for year-round
and comfort.
• Innovative design: One side offers cooling, simply turn the unit around and attach the hose for heating.
• Easy-roll casters.
• Built-in hose storage.
• Dual, easy-access antimicrobial nylon lters
• Electronic control pad provides easy identifying icons for simplified user operation
• 24-hour programmable timer for cooling, heating and dehumidication modes
• Unique Sleep Control function – Increases temperature 2 degrees every 4 hours
• LCD remote control
conditioning
3
UNPACKING INSTRUCTIONS
UNPACKING INSTRUCTIONS
1. Place the unit in the correct upright position before unpacking.
2. Cut the two packing straps.
3. Slide the carton in an upward motion and it will release from the base.
4. Grip the carry handles located on either sides of the unit and carefully lift until it slides out of the foam
base.
5. Remove the hot air outlet to take out the exhaust hose and (upper/lower) hose adapters.
6. Install the exhaust hose on the unit before operating the unit.
CONTENTS
CONTENTS
1. Portable air conditioner unit
2. Remote control (1 pc)
3. A-type window kit
4. Upper/ Lower hose adapters
5. Joint tube
6. Exhaust hose (1 pc)
7. Batteries (2 pcs)
8. User Manual (1 pc)
4
PARTS
1. Control panel
2. Remote control receiver
3. Adjusting Dials
4. Adjustable air vent
5. Joint tube
6. Exhaust hose
7. Upside drain hole
8. Cool air inlet
9. Cool air lter
10. Hot air inlet
11. Hot air lter
12. Downside drain hole
5
DISPLAY FUNCTIONS
: LED DISPLAY
: POWER
: MODE
: TIMER
: SLEEP mode
1. FUNCTIONS Key Description:
POWER (On/ Off Key) :
- Standby mode (Default)
- Turn On/ Off the unit
- Turn on the unit, the indicator lights on.
- Turn of the unit to standby mode, the indicator lights off.
2. MODE (Functions switch key) : the switching cycle is Cooling (Default) > Dehumidifying > Heating,
and back to Cooling again.
COOLING/Heating/ Dehumidication Modes:
The indicator light turns blue for cooling, red for heating, and green for dehumidication>
If the compressor shuts down, the indicator blinks.
The display window shows setting temperature on screen.
3. TEMPERATURE REGULATION Knob (UP/Down)
- Rotate the dial in clockwise direction; the value will increase 1ºC/1ºF per scale. The maximum
value is 30ºC/86ºF (25ºC/77ºF). Rotate the dial in a counter-clockwise direction to decrease the
value 1ºC/1ºF per scale. The minimum value is 17ºC/63ºF(15ºC/59ºF).
- In DEHUMIDIFYING mode, the dial is inactive.
4. PROGRAMMABLE TIMER
- Press the key to activate the timer, the indicator lights on; press the key again to cancel
the timer setting, the indicator light will turn off.
- While the unit is operating or in standby, press the key and rotate the dial in clockwise/
counter-clockwise direction to set the Auto-Off time from 0 to 24 hours.
- During the TIMER mode, press and hold the key for 1 second, the time increases continuously
- To set the time, press the key before rotating the dial . The display will ash the on/ off time
during setting and show the time setting on screen.
6
DISPLAY FUNCTIONS
5. L.E.D. DISPLAY
The display indicates the current setting temperature or the timer setting. When the set temperature or
the timer is adjusted, the new setting is shown then the display returns the current set temperature.
The display is also used to show error codes should a fault occur, see TROUBLE SHOOTING.
6. FAN SPEED
Rotate the dial in clockwise direcon, the speed changes from F1 (Low) → F2 (Medium) → F3 (High)
→ AU (Auto)
Rotate the dial in counter-clockwise direcon, the speed changes backwards from AU (Auto) → F3 (High)
→ F2 (Medium) → F1 (Low)
In COOLING mode, fan speeds are available from F1 (Low), F2 (Medium), and F3 (High) to AU (Auto).
Default fan speed is in F2 (Medium) speed. Rotate the knob to F1 (Low) → F2 (Medium) → F3 (High)
→ AU (Auto) fan speed.
If “AUTO” is selected (During cooling funcon),”HIGH” or “MEDIUM” or “LOW” will be selected automacally
according to the dierence between seng temperature and ambient temperature.
7. TIMER MODE
TIMER scale: from 0 to 24 hours.
- Use the TIMER to set the Auto-O me during operang or in Stand-By mode
- While seng the TIMER, use the key or the dial is available to adjust to the desired me.
- With each press of the TIMER key, the value on the display will increase from”00”→”01”……→ to”24”
and back to “00” again.
- Set the Auto- On / Auto- O mer:
- Press the key to preset the Auto-O mer, and the display will ash the seng me. The display will
return to show operang mode aer 5 seconds.
- Press the key before the preset me to cancel the Auto-O mer, and the unit will be turned o directly.
- While seng the Auto-On mer, you can preset the funcons at the same me.
- Press the key to set the Auto-On mer. Aer seng up, the display shows the rest of me.
- Press the key before the preset me to cancel the Auto-On mer, and the unit will be turned on directly
- Aer seng up the Auto-On mer, the unit is sll available to be controlled or be switched to other funcons.
7
DISPLAY FUNCTIONS
8. SLEEP CONTROL FUNCTION
In “Sleep” mode, your unit will automacally go into low fan speed allowing the temperature to slowly dri up
(in cooling) or down (in heang). See below:
- While in cooling mode, press the SLEEP key to set the temperature. It increases 2°F after an hour
and at most increases 4°F after 2 hours.
- While in heating mode, press the SLEEP key to set the temperature. It decreases 2°F after hour and
at most decreases 4°F after 2 hours.
- Press the SLEEP key again to cancel the seng.
9. ALARM
When the water tank is full,”E4” will be displayed on the display panel. To resume operaon, please remove the
rubber cap of the drain hose to drain out the water rstly. The E4 warning will disappear aer draining, and then
you can restart the unit by pressing the POWER key.
8
REMOTE CONTROL FUNCTIONS
Instruction for the operating keys:
When a remote control signal is transmitted, a transmission icon on the display ashes once, indicating the
signal has been transmitted.
9
REMOTE CONTROL FUNCTIONS
1. Transmission window
2. Liquid crystal display
3. Mode select key:
Select from among the three functions: cooling, heating and dehumidifying. The fast key function
indicates the above operating modes in a cycle when the key is pressed without being released.
However, the transmission icon will not appear until the key is released and the conrmed mode is
transmitted.
4. Setting keys for room temperature:
The set temperature will rise by 1°F when the key is pressed once and the set temperature will
fall by 1°F when the key is pressed once. Both keys have the fast key function and can make the set
temperature rise or fall continuously when the keys are pressed without release.
5. Power key:
When this key is pressed, the memorized modes and other information about temperature, speed,
direction of airow, sleep, etc., in the remote control will be transmitted to the unit and it will operate
correspondingly. When the key is pressed again, the main unit will stop immediately.
6. Sleep key
When this key is pressed, the air ow of the unit changes into sleep mode (low speed).
(1) Press “SLEEP” key, set sleep function; press again, and cancel sleep setting.
(2) The temperature will increase 2°F half an hour after setting sleep function, and will
increase at most 4°F every two hours after that.
(3) When the main power supply is cut off, the sleep function setting will be cancelled
automatically.
(4) When you turn off the unit, sleep function setting will be cancelled automatically.
10