Friedrich PXSB23020, PXSB23030, PXSB26515, PXSB26520, PXSB26530 User Manual

...
Packaged Terminal Air Conditioners
SG Series
Our best PTAC ever. More efcient. More reliable. Ultra quiet. Greater guest comfort.
FRIEDRICH.COM THE EXPERTS IN ROOM AIR CONDITIONING
Friedrich SG Series PTAC offers the durability
and efciencies you’ve come to expect from
Friedrich, and more.
Improved performance and design enhancements combine to deliver our most efcient and reliable PTAC yet.
Advanced design for greater energy efciency
Series maximizes the internal surface area to deliver higher
efciencies
• EERs up to 13.0
Dependable performance begins with the highest quality materials and components
Stainless steel endplates on
the coils for better corrosion resistance
Galvanized, zinc-coated steel
wall sleeves brought together with durable construction and rigorous testing
Engineered for maximum guest comfort
Tangential fan provides quiet,
yet powerful airflow that quickly reaches all corners of the room
Two motor design for quieter
indoor sound levels
Thick insulation on the inner
walls reduce sound transfer into the room
Constant Fan mode produces
a steady stream of white noise in both cooling and heating modes that masks sound level changes when the compressor cycles on and off, and also masks outdoor noise.
2 | FRIEDRICH SG SERIES PTAC
Friedrich reliability is backed by an industry-leading 2-year parts and labor and 5-year limited warranty.
PARTS & LABOR
WARRANTY
See warranty documentation for full details.
LIMITED WARRANTY
Commercial grade quality PTAC utilizes a modular design
that provides easy access to key components
Key components can be easily accessed by your maintenance team so units can be removed, serviced and placed back in service faster.
Commercial grade quality components provide reliable performance in even the most extreme climates.
Easy to read and use digital controls
Reversible louvers for air path
modications
Easy-access, interchangeable antimicrobial air
lters (2)
DiamonBlue Advanced Corrosion Protection™ comes standard on all PTACs for long life in harsh coastal environments.
Indoor coil frost sensor protects compressor
Quiet, efcient rotary compressor mounted on large vibration isolators
Durable, powder
coat paint nish
Outdoor coil has Diamonblue Advanced Corrosion Protection® and stainless steel endplates
The tangential blower wheel creates a
wide path air ow that reaches the furthest
corner of the guest room more quietly than conventional fans.
Friedrich offers a complete line of PTACs–
Available in electric heat and heat pump models 7000 to 15000 Btus All capacities have multiple heater options 230 and 265V
Electric Heat
COOLING
7000-15000 Btu
EERs up to 13.0
ELECTRIC HEAT
8300-17000 Btu
EERs up to 13.0
Heat Pump
COOLING
7000-15000 Btu
EERs up to 13.0
REVERSE HEATING
6000-13300 Btu
Up to 3.6 COP
AUXILIARY ELECTRIC HEAT
8300-17000 Btu
Voltage 230V 265V Amps Heater Size
Receptacles
NEMA# Receptacle
NEMA#
Plug
5X THE SURFACE AREA = WIDER AIR PATH
RECEPTACLES AND FUSE TYPES
15 20 30 15 20 30
2.5 kW 3.5 kW 5.0 kW 2.5 kW 3.5 kW 5.0 kW
6-15R 6-20R 6-30R 7-15R 7-20R 7-30R
6-15P 6-20P 6-30P 7-15P 7-20P 7-30P
3
FEATURES
Durable & Reliable Construction
Stainless steel endplates reduce outdoor coil corrosion.
Galvanized zinc coated steel wall sleeve and steel base pan
undergo an 11-step preparation process, are powder coated with
a polyester nish and cured in an oven for exceptional durability.
Additional heating element bottom plate above an improved heat shield provides extra thermal protection.
Additional thermistor on the blower scroll outlet regulates internal temperature.
Factory run-tested units reduce problems in the eld.
Internal diagnostic program can alert maintenance to component
failures or operating problems. Fourteen numeric service error codes stored in memory facilitate rapid unit diagnostics.
Easy access lters simplify maintenance and extend the life of the product.
Room freeze protection initiates heat if temperature falls to 40°F in an unoccupied room.
Random compressor restart protects electrical systems from overload when power is restored.
Tamper-resistant, anodized stamped aluminum grille
withstands chalking and oxidation.
Break-proof control door design maintains the integrity of the unit.
Indoor coil frost sensor protects the compressor to lengthen the
life of the unit.
Diamonblue Technology protects the outdoor coil from harsh environments.
Warranty and Support
Industry leading warranty features 2-year full warranty on parts
and labor and 5-year limited warranty.
Nationwide service network and U.S. based Friedrich expert technical team ensures you get fast, knowledgeable service.
Energy Efcient & Energy Smart
Super-efcient refrigeration design with EERs up to 13.0 and
COP up to 3.6.
Exceptional FriedrichLink® energy management thermostats available (wired & wireless) with integrated occupancy
sensor, ve distinct energy presets and comprehensive remote
management capability.*
Advanced coil design adds more surface area leading to higher efficiencies.
Thicker steel inner-wall and foam construction decreases thermal transfer and energy loss.
Energy efcient heat pump models available in our complete line.
Electronic defrost control ensures more run time in efcient
heat pump mode.
Electronic temperature limiting to adjust low/high temperature range limits for reduced energy usage.
Slinger ring technology in condensate removal system cools the
coil and increases efciency.
Desk control ready to allow hotel owners to control units from a central location.
Sound Reduction Technology
Two permanently lubricated fan motors for added durability
and reduced sound levels indoors.
Quiet, efcient rotary compressor mounted with vibration isolators to keep the compressor running smoothly and quietly.
High-density insulation and steel inner wall block outdoor noise.
Tangential blower wheel creates a wide path air ow that
reaches the furthest corner of the guest room more quietly than conventional fans.
Comfort, Health & IAQ
Dehumidification removes up to 3.1 pints/hour of moisture in
cool mode to improve comfort and reduce the chance of mold and mildew growth.
Constant Fan mode provides continuous fan operation in cooling or heating modes to create a steady stream of white noise that masks sound level changes when the compressor cycles on/off.
Fresh air damper brings in fresh outside air when desired.
Intuitive unit controls are user friendly with easy-to-read
LED display that can show either set-point or actual room temperature as selected by owner.
Anti-microbial air lters are easy to access and washable.
Instant Heat on heat pump models quickly heats a room to the
desired temperature for increased comfort.
Even-heat monitoring checks room temperature and automatically adds heat boost if necessary.
Automatic periodic sampling of room temperature to ensure desired conditions are maintained.
Reversible indoor air louvers to easily change direction
of airow.
Ease of Maintenance & Installation
Modular product design ensures easy access to key components
for cleaning and repairs; including washable, lift-out air lters.
Remote thermostat pop-out wiring module allows easier wiring and unit change out without rewiring thermostat.
Standard heat output power cord comes attached to the unit.
Compact front is designed to preserve indoor oor space with a depth of 7¾ inches.
Faultless Sure-hold front cover system
securely attaches the front each time.
Inner wall service plate provides service access to tangential blower bearing without
having to open up the entire inner wall.
Unit may be installed ush with the oor.
* Energy management capability requires purchase of additional hardware and service fee.
4 | FRIEDRICH SG SERIES PTAC
Save big on energy without compromising guest comfort
FriedrichLink® Thermostats, the Energy Management Solution for Friedrich PTAC
Real Time Motion and Thermal Occupancy Sensor
Integrated Occupancy Sensor uses a combination of motion and thermal sensing technologies for accurate occupancy detection at all times - no need
to install additional devices such as door switches or sensors.
Wired or Wireless Installation
Wired or wireless connectivity with extensive conguration options deliver
full compatibility and easy integration with virtually any packaged HVAC system.
Friedrich’s EMRT1 and EMWRT1 thermostats use real-time motion and thermal occupancy detection to save energy.
When the room is unoccupied, the thermostat automatically adjusts the temperature to eliminate unneces­sary heating and cooling.
5 Energy Savings Presets
5 distinct energy saving modes make it easy to
choose the optimal energy saving settings for any property.
Remote Management*
Web-based remote management provides expansive
solutions for remote monitoring and conguration
from any computer connected to the internet.
Built-in Wireless Networking enables remote management without using or interfering with property’s existing wireless infrastructure. True mesh networking eliminates the need for additional networking equipment such as signal repeaters or multiple data collection boxes.
*Requires an optional “Online Connection Kit” and a one-time license fee. Optional Humidity Control Feature available through Remote Management. See accessories page 6.
Monitor room status and see the operation, occupancy and energy ef­ficiency status of each room.
Advanced Energy Saving Features
Fully congurable energy
saving modes maximize energy savings without compromising guest comfort.
Temperature setback automatically adjusts the temperature when the room is unoccupied in order to save energy.
Temperature recovery
calculates the setback temperature so that the desired temperature can
be restored within specied
time.
Setback optimization contin­uously monitors temperature recovery rate in the room and adjusts setback temperature to maximize energy savings.
Setback limits allow maximum and minimum room temperature to be set when the room is unoccupied.
Set point limits prevent guests from setting room temperature to extreme, energy-wasting levels.
Room status displays operation, occupancy and
energy efciency status of
each room.
Room detail displays temperature and occupancy changes in a room.
Energy reports monitor energy use and can even evaluate the performance of energy saving features.
Intuitive interface makes it easy to apply different settings to different rooms.
User management allows
conguration of custom
access permissions and
alert notication settings for
different users.
Built-in diagnostic tools
automatically send email alert
notications to hotel staff.
FriedrichLink® For Lodging
5
OPTIONAL ACCESSORIES
WALL SLEEVE PDXWSA
Galvanized steel is prepared in a multi-step process for stronger paint adhesion, then powder coated with a polyester finish and cured in an oven for exceptional
durability. The wall sleeve is insulated for thermal efciency and noise reduction.
SLEEVE DIMENSIONS: 16" H x 42" W x 13 3/4" D CUT OUT DIMENSIONS: 16 1/4" H x 42 1/4" W FRONT COVER DIMENSIONS: 16" H x 42" W x 7 3/4" D
DEEP WALL SLEEVES
PDXWSEX T18
For walls up to 17 1/2” deep.
PDXWSE XT 24
For walls up to 23 1/2” deep.
PDXWSEX T (Custom depth wall sleeve)
One-piece, extended wall sleeve with built-in bafe for walls from 13 1/4" to 25 1/2"
deep are available by special order.
SLEEVE EXTENSION RETROFIT KIT PXSE
2 1/4" sleeve extension attached to the room side of the sleeve to allow for the installation of a PD-series Friedrich PTAC in an 11 1/2" deep T-series sleeve.
DIGITAL REMOTE THERMOSTAT
Wall-mounted digital thermostats with two fan speeds.
Single stage cool / heat for PDE models. Single stage cool / dual stage heat for PDH models
Features backlit display and multiple conguration modes, available in wired and
wireless options.
RT6 Wired wall-mounted thermostat (can be battery or unit powered).
WRT1
Wireless wall-mounted thermostat (battery powered).
PDXWSA
Deep wall sleeve extension PDXWSEXT18 shown with weather panel in place
PXSE
RT6 WRT1
FRIEDRICHLINK® ENERGY MANAGEMENT THERMOSTATS
EMRT1
Wired thermostat with occupancy sensor.
EMWRT1
Wireless thermostat with occupancy sensor.
EMOCT EMRAF EMRHCF
Online connection kit. Remote access fee. Remote humidity control fee.
REMOTE THERMOSTAT ESCUTCHEON KIT PDX RTA
Kit contains escutcheons that can be placed over the factory control buttons
(recommended when a remote wall mounted thermostat is used as controls become inoperable). The escutcheon directs the user to the wall thermostat
for operation and retains the LED window to display error codes and diagnostic information. 10 pack.
CONDUIT KIT /JUNCTION BOX PXCJA
Hard wire conduit kit with junction box for 208/230V and 265V units (subbase not required). Kit includes a means of quick disconnect for easy removal of the chassis.
DISCONNECT SWITCH PXDS
EMRT1, EMWRT1 EMOCT
PDXRTA
PXCJA
PXDS
6 | FRIEDRICH SG SERIES PTAC
OPTIONAL ACCESSORIES
STANDARD GRILLE PXGA
Standard, stamped, anodized aluminum to resist chalking and oxidation.
ARCHITECTURAL GRILLES
Architectural grilles consist of heav y gauge 6063-T5 aluminum alloy.
PX AA Clear extruded aluminum. PXBG Beige acrylic enamel. PX SC Available in custom colors.
DECOR ATIVE SUBBASE (black)
PXSBA
Provides unit support for walls less than six inches thick. Includes leveling legs,
side ller panels and mounting brackets for electrical accessories. Accepts
circuit breaker, power disconnect switch and conduit kit.
ELECTRICAL SUBBASE
Provides unit support for walls less than six inches thick. Includes leveling legs, side
ller panels, mounting brackets, a plug-in receptacle and eld-wiring access. The sub-
base also includes electrical knockouts for power disconnect switch or circuit breaker.
PXSB23020 PXSB23030 PXSB26515 PXSB26520 PXSB26530
Electrical Subbase - 230V 15 & 20A Electrical Subbase - 230V 30A Electrical Subbase - 265V 15A Electrical Subbase - 265V 20A Electrical Subbase - 265V 30A
PXGA
PXAA
PXSBA
POWER CORDS
PXPC23015A LCDI 230V 15A Cord - 2.5 kW 67 in. PXPC23020A LCDI 230V 20A Cord - 3.5 kW 67 in. PXPC23030 LCDI 230V 30A Cord - 5.0 kW 67 in. PXPC26515A Non-LCDI 265V 15A Cord - 2.5 kW 27 1/2 in. PXPC26520A Non-LCDI 265V 20A Cord - 3.5 kW 27 1/2 in. PXPC26530 Non-LCDI 265V 30A Cord - 5.0 kW 27 1/2 in.
PXFTA
Antimicrobial air lters. 10 pack. Each PTAC requires 2 lters.
CONDENSATE DRAIN KIT
PXDR10
Attaches to the bottom of the wall sleeve for internal draining of condensate, or
to the rear wall sleeve ange for external draining. Recommended for all units to
remove excess condensate. 10 pack.
LATERAL DUCT ADAPTER PDXDA A
Attaches to the Friedrich PTAC/PTHP unit to direct up to 35% of the total airow to a
second room. The unit-mounted duct plenum features a front-mounted aluminum grille that has two positions to provide the most optimal air direction. The air may be directed to either the left or the right of the unit through the supplied 3 1/2" H x 7" W x 47" L plenum. Plenum may be cut to length by the installer. Kit includes duct plenum, front grille, 47" duct extension, duct discharge grille, duct end cap and all necessary mounting hardware.
Length
PXSB
PXPC
PXFTA
PXDR10
LATERAL DUCT EXTENSION PDXDEA
Additional 3 1/2" H x 7" W x 47" L plenum used with the LATERAL DUCT ADAPTER.
A maximum of three duct extensions may be used together. Note: Ducted airow
is reduced as duct length is increased.
POWER FRESH AIR DOOR KIT
PXPD*/PXPV
PXPD230 /PXPD265 for 230V & 265V units.
POWER FRESH AIR VENT KIT PXPV230 /PXPV265 for 230V & 265V units.
*Fan not included in PXPD.
PDXDAA and PDXDEA ship together
7
LISTED
SPECIFICATIONS
PTAC Electric Heat models
PDE07K PDE07R PDE09K PDE09R PDE12K PDE12R PDE15K PDE15R
PERFORMANCE DATA:
Cooling Btu 7200/7000 7200 9400/9200 9400 11800/11600 11800 14500/14200 14500
Cooling Watts 550/535 550 775/760 775 1015/1000 1015 1390/1365 1390
Energy Efciency Ratio, EER 13.0/13.0 13.0 12.1/12.1 12.1 11.6/11.6 11.6 10.4/10.4 10.4
Moisture Removal (pints/hr.) 1.7 1.7 2.1 2.1 2.7 2.7 3.1 3.1
Sensible Heat Ratio 0.86 0.86 0.85 0.85 0.75 0.75 0.67 0.67
ELECTRICAL DATA:
Voltage (1 PHASE, 60 Hz) 230/208 265 230/208 265 230/208 265 230/208 265
Volt Range 253-187 292-239 253-187 292-239 253-187 292-239 253-187 292-239
Current (Amps) 2.7/2.9 2.4 3.7/3.9 3.3 4.9/5.1 4.2 6.2/6.7 5.4
Power factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97
Compressor LRA 13.0 12.5 19.5 13.5 21.5 19.0 28.9 21.6
Compressor RLA 2.5 2.2 3.5 3.0 4.7 3.9 5.9 5.05
Outdoor Fan Motor, HP 0.080 0.080 0.080 0.080 0.086 0.086 0.086 0.086
AIRFLOW DATA:
Indoor CFM, HIGH 345/315 345 355/325 355 400/390 400 400/390 400
Indoor CFM, LOW 270/255 270 300/275 300 325/310 325 325/310 325
Vent CFM 75 75 75 75 75 75 75 75
PHYSICAL DATA:
Sleeve Dimensions (H x W x D) 16” x 42” x 13 3/4” (all models)
Dimensions with Front (H x W x D) 16”x 42”x 21 1/2” (all models)
Cut Out Dimensions (H x W x D) 16 1/4”x 42 1/4” (all models)
Net Weight (lbs.) 106 107 115 115 119 118 121 121
Shipping Weight (lbs.) 126 127 135 135 139 138 140 140
R-410A CHARGE (oz.) 23 23 24 24 36 36 36 36
Dimensions with Packaging (inches) 17 7/8" x 45" x 25 1/4" (all models)
Models ending in 'K' are 230/208V, models ending in 'R' are 265V
PTAC Heat Pump models
PDH07K PDH07R PDH09K PDH09R PDH12K PDH12R PDH15K PDH15R
PERFORMANCE DATA:
Cooling Btu 7200/7000 7200 9400/9200 9400 11800/11600 11800 14500/14200 14500
Cooling Watts 550/535 550 775/760 775 1015/1000 1015 1390/1365 1390
Energy Efcient Ratio, EER 13.0/13.0 13.0 12.1/12.1 12.1 11.6/11.6 11.6 10.4/10.4 10.4
Reverse Heating Btu 6000/5800 6000 8300/8100 8300 10600/10400 10600 13300/13000 13300
Heating Watts 485/470 485 695/675 695 910/895 910 1255/1225 1255
COP 3.6/3.6 3.6 3.5/3.5 3.5 3.4/3.4 3.4 3.1/3.1 3.1
Moisture Removal (pints/hr.) 1.7 1.7 2.1 2.1 2.7 2.7 3.1 3.1
SENSIBLE HEAT RATIO 0.86 0.86 0.85 0.85 0.75 0.75 0.67 0.67
ELECTRICAL DATA:
Voltage(1 PHASE, 60 Hz) 230/208 265 230/208 265 230/208 265 230/208 265
Volt Range 253-187 292-239 253-187 292-239 253-187 292-239 253-187 292-239
Current (Amps) 2.7/2.9 2.4 3.7/3.9 3.3 4.9/5.1 4.2 6.2/6.7 5.4
Reverse Heat. Amps 2.4/2.6 2.2 3.4/3.2 3.1 4.2/4.7 3.7 6.2/6.7 5.0
Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97
Compressor LRA 13.0 12.5 19.5 13.5 21.5 19.0 28.9 21.6
Compressor RLA 2.5 2.2 3.5 3.0 4.7 3.9 5.9 5.05
Outdoor Fan Motor, HP 0.080 0.080 0.080 0.080 0.086 0.086 0.086 0.086
AIRFLOW DATA:
Indoor CFM, HIGH 345/315 345 355/325 355 400/390 400 400/390 400
Indoor CFM, LOW 270/255 270 300/275 300 325/310 325 325/310 325
VENT CFM 75 75 75 75 75 75 75 75
PHYSICAL DATA:
Sleeve Dimensions (H x W x D) 16” x 42” x 13 3/4” (all models)
Dimensions with Front (H x W x D) 16”x 42”x 21 1/2” (all models)
Cut Out Dimensions (H x W x D) 16 1/4”x 42 1/4” (all models)
Net Weight (lbs.) 113 112 119 119 122 119 124 122
Shipping Weight (lbs.) 133 132 139 139 141 139 144 144
R-410A CHARGE (oz.) 34 34 34 34 36 36 39 39
Dimensions with Packaging (inches) 17 7/8" x 45" x 25 1/4" (all models)
Models ending in 'K' are 230/208V, models ending in 'R' are 265V
Due to continuing research in new energy-saving technology, specications are subject to change without notice. Warranty limited to installations in the United States, Puerto Rico, Mexico and Canada only. See warranty documentation for full details.
ULCDTP
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 www.friedrich.com
BRO_SGPTAC_COMM_2016 (Rev. 1) Printed in USA
Loading...