Friedrich PDE07K3SG Installation

Model PXGA
Installation Instructions
STANDARD LOUVER
For Use With Packaged Terminal Units
Please read these instructions completely before attempting installation.
NOTE: These instructions apply to the Packaged Terminal Unit Standard Louver Installation Kit ONLY. Refer to chassis Installation/Operation manual and Wall Sleeve Installation Instructions for additional information.
Check box for parts listed in Figure 1.
Installation
1. Remove the center support and weatherboard if still installed in the sleeve.
2. Insert six plastic grommets into the louver openings from the outside of the louver as shown in Figure 2.
3. Insert two #8 x 3/8” sheet metal screws (provided) in the top two outside edge plastic grommets, and tighten them half way into the grommets.
Figure 1
Quantity
1 6 6
Figure 2
Parts List - Standard Louver
Description
Stamped Aluminum Louver Plastic Grommets #8 x 3/8" Sheet Metal Screws
Plastic Handles
CAUTION: Bodily injury can be caused by louvers falling from a building during installation. It is recommended that a safety line be attached to the louver and to an anchor point inside the building during installation.
4. Grasp the louver by the attached plastic handles. Position it with the condensate drain knockouts fac­ing down. From inside the building, maneuver the louver through the wall sleeve and pull it toward you until the screw heads are inserted into the keyhole slots at the top of the wall sleeve. Tighten the two screws completely.
5. Insert the remaining screws into the remaining holes and tighten securely.
Stamped Louver
Stamped Louver
Knockout For Drain Opening
Grommet
#8 x 3/8"
Sheet Metal Screw
Wall Sleeve
920-122-00 (3-07)
Models PXAA / PXBG / PXSC
Installation Instructions
ARCHITECTURAL LOUVER
For Use With Packaged Terminal Units
Please read these instructions completely before attempting installation.
NOTE: These instructions apply to the Packaged Terminal Unit Architectural Louver Installation Kit ONLY. Refer to chassis Installation/Operation manual and Wall Sleeve Installation Instructions for additional information.
Check box for parts listed in Figure 1.
Figure 1
Quantity
1 4 4 4
Parts list - Architectural Louver
Description
Architectural Louver #10-24 x 1" Threaded Metal Studs #10-24 Hex Nuts 7/32" I.D. Flat Washers
Installation
1. Screw a threaded metal stud into each of the holes at the four corners of the louver.
Figure 2
Louver
2. From inside the building, grasp the louver at the vertical supports and maneuver the louver through the wall sleeve. Pull towards you until the threaded studs are inserted into the four holes of the wall sleeve.
CAUTION: Bodily injury can be caused by louvers falling from a building during installation. It is recommended that a safety line be attached to the louver and an anchor point inside the building during installation.
3. While holding the louver with one hand, start washers and nuts on each of the four studs. Tighten the nuts securely.