INSTALLATION INSTRUCTIONS
FOR INTERNAL DRAIN KIT
(IDK)
Apply Sealer to
the bottom of
the Drain Plate
Wall Sleeve
Drill a .625"
diameter
hole here
Sleeve
Base
0.5" In
from edge
Drill a .625"
diameter
hole in the
Dimple
1. DRILL A .625" DIAMETER HOLE IN THE BOTTOM OF THE SLEEVE BASE TO THE
DIMENSIONS SHOWN.
2. APPLY A SILICONE TYPE OF SEALER TO THE OUTSIDE BOTTOM EDGES OF THE
DRAIN PLATE.
3. INSERT THE DRAIN TUBE INTO THE HOLE AND PRESS THE DRAIN PLATE DOWN TO
FORM A WATERTIGHT SEAL AGAINST THE SLEEVE BASE.
4. DRILL A .625" DIAMETER HOLE IN THE BOTTOM OF THE BASE PAN AS SHOWN
IN THE ILLUSTRATION. THIS HOLE ALLOWS CONDENSATE TO ENTER THE WALL
SLEEVE WHERE IT TRAVELS TO THE DRAIN KIT FOR DISPOSAL.
bottom of
the basepan
4.75" From
back of
basepan
616-197-01 (10-04)

INSTRUCCIONES PARA LA
INSTALACION DEL IDK
(KIT DE DESAGÜE)
Aplique el sellador al
extremo de los bordes
inferiores del desagüe
Gabinete
Taldre un hueco
ce 0.625" aquí
Base del Gabinete
.5" del borde
derecho del
cogegotas al
hueco
4.75" de
Taldre un
hueco de .625"
in la base del
Hoyuelo
1. TALADRE UN HUECO DE .625" EN LA BASE DEL GABINETE, A LAS DISTANCIAS
INDICADAS.
2. APLIQUE UN SELLADOR DEL TIPO DE LOS DE SILICONA AL EXTREMO DE LOS
BORDES INFERIORES DEL DESAGÜE.
3. INSERTE EL TUBO DE DRENAJE DENTRO DEL HUECO Y PRESIONE EL DESAGÜE
HACIA ABAJO PARA QUE SELLE BIEN CONLA BASE DEL GABINETE, EVITANDO LAS
FILTRACIONES DE AGUA.
4. TALDRE UN HUECO DE .625" EN LA BASE DEL CHASIS TAL COMO SE MUESTRA
ARRIBA. ESTE HUECO PERMITE QUE LA CONDENSACION VAYA A LA BASE DEL
GABINETE DONDE SE EVACUA A TRAVES DEL KIT DE DESAGÜE.
cogegotas del
chasis
la parte
posterior del
cogegotas
616-197-01 (10-04)

INSTRUCTIONS D’INSTALLATION
POUR LE KIT D'ÉVACUATION DE
LA CONDENSATION (IDK)
Appliquer du mastic
sur le fond du plateau
d'évacuation
Enveloppe
Percer un trou
de 0.625" ici
Plateau de
l'enveloppe
Percer un
trou de 0.625"
pouces au
Fossette
1. PERCER UN TROU DE 0.625" POUCES AU FOND DU PLATEAU DE L'ENVELOPPE
COMME MONTRÉ DANS L'ILLUSTRATION.
2. APPLIQUER DU MASTIC AUX SILICONES SUR LES BORDS EXTERNES DU PLATEAU
D’ÉVACUATION.
fond du
plateau
0.5" pouces
à partir du
coté
4.75"
pouces à
partir de
l'arrière du
plateau
3. INSÉRER LE TUBE D’ÉVACUATION DANS LE TROU ET APPUYER SUR LE PLATEAU
D’ÉVACUATION POUR AVOIR UN JOINT ÉTANCHE À L'EAU.
4. PERCER UN TROU DE 0.625" POUCES AU FOND DU PLATEAU COMME MONTRÉ
DANS D'ILLUSTRATION. CE TROU PERMET QUE LA CONDENSATION RENTRE DANS
L'ENVELOPPE OÙ ELLE S'ÉVACUE À TRAVERS DU KIT D'ÉVACUATION.
616-197-01 (10-04)

FRIEDRICH AIR CONDITIONING CO.
Post Office Box 1540 · San Antonio, Texas 78295-1540
4200 N. Pan Am Expressway · San Antonio, Texas 78218-5212
(210) 357-4400 · FAX (210) 357-4480
www.friedrich.com
Printed in the U.S.A.
616-197-01 (10-04)