PRO SERIES | DUCTLESS SPLIT SYSTEMS
SINGLE ZONE • THE INSIDER® CONCEALED DUCTED HEAT PUMPS
Indoor unit is installed in the ceiling or furr down, totally concealed,
for unobtrusive installation.
Features
• Precision Inverter® technology
(variable speed compressor)
• Soft start compressor
• BLDC motor
• Cooling/Heating/Fan mode
• Dry mode
• 3 fan speeds
• Auto restart
• Auto changeover
• DiamonGold Advanced Corrosion
Protection™
• Control lock function on controller
• External Static Pressure Range
0-.40
Operates in extreme conditions
• Built-in low ambient, down to
5°F on 9k/12k/18k models, down
to -4°F on 24k/36k models
(Cooling mode)
• Low ambient operation down to
-4°F (Heating mode)
PRECISION
PARTS
WARRANTY
COMPRESSOR
WARRANTY
16 | FLOATING AIR® SERIES DUCTLESS
PRO SERIES SPECIFICATIONS
PERFORMANCE RATINGS Single Zone - The Insider
SYSTEM MODEL NO.
INDOOR MODEL
OUTDOOR MODEL
SPECIFICATIONS
CAPACITY COOLING (RATED) Btu
CAPACITY COOLING (MIN~MAX) Btu
CAPACITY HEATING @470F (RATED) Btu
CAPACITY HEATING @170F (RATED) Btu
CAPACITY HEATING (MIN~MAX) Btu
SENSIBLE HEAT RATIO
SEER
EER
COP (@47°F) .
HSPF
ENERGY STAR
MOISTURE REMOVAL Pts/h
AIRFLOW (LOW, MED, HIGH ) CFM
SOUND RATING - INDOOR H/M/L dB(A)
SOUND RATING - OUTDOOR dB(A)
OPERATING RANGE (COOLING) °F
OPERATING RANGE (HEATING) °F
EST. YEARLY OPERATING COST $
ELECTRICAL DATA
POWER SOURCE
MINIMUM AMPACITY A
COOLING WATTS W
COOLING AMPS
HEATING AMPS
MAX. TD FUSE/BREAKER A
POWER AND COMMUNICATION CABLE No. x AWG
REFRIGERATION SYSTEM
REFRIGERANT
COMPRESSOR TYPE
CONNECTIONS
LIQUID LINE O.D. in
SUCTION LINE O.D. in
FACTORY PRECHARGE ft
REFRIGERANT CHARGE oz
MIN./MAX. LINE LENGTH ft
MAX. HEIGHT DIFFERENCE ft
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X D in
NET WEIGHT lbs
SHIPPING WEIGHT lbs
OUTDOOR UNIT
W X H X D in
NET WEIGHT lbs
SHIPPING WEIGHT lbs
TOTAL NET WEIGHT lbs
TOTAL SHIPPING WEIGHT lbs
FPHD093 FPHD123 FPHD183 FPHD243 FPHD363
FPHFD09A3A FPHFD12A3A FPHFD18A3A FPHFD24A3A FPHSD36A3A
FPHFR09A3A FPHFR12A3A FPHFR18A3A FPHFR24A3A FPHFR36A3A
9000 12000 18000 24000 36000
4850-11600 5800-13100 8000-19200 8600-25200 12600-36800
9000 12000 18000 24000 36000
6200 8200 14700 19600 22000
4340-12280 6000-14400 7000-21200 7600-28400 15000-42600
76% 76% 76% 76% 76%
17 19 19 18 18
12 11 12.2 12.5 10.9
3.2 3.2 3.4 3.6 3
10.00 10.00 10.00 10.00 9.50
— — — — —
2 3 5 5.1 7.61
235/285/309 235/285/338 370/440/529 501/574/647 618/735/853
29/27/26 36/33/30 38/35/33 38/36/34 49/43/39
52 54 68 54 61
5-118 5-118 5-118 -4-118 -4-118
-4-75 -4-75 -4-75 -4-75 -4-75
53 72 124 169 376
230/208-60-1 230/208-60-1 230/208-60-1 230/208-60-1 230/208-60-1
23.0 23.0 23.0 23.0 4.6
750 1091 1610 2200 3300
3.7 4.8 7.0 8.6 14.4
4.1 4.8 7.3 8.7 15.2
20 30 30 30 50
4 x 14AWG 4 x 14AWG 4 x 14AWG 4 x 14AWG 4 x 14AWG
R410a R410a R410a R410a R410a
Rotary Rotary Rotary Rotary Rotary
Flare Flare Flare Flare Flare
1/4 1/4 1/4 3/8 3/8
3/8 3/8 1/2 5/8 3/4
25 25 25 25 25
33.5 45.9 56.5 75.3 111
25 25 25 25 25
82 82 82 164 164
42 1/2 x 11 1/4 x 22 1/4 42-1/2 x 22-1/4 x 11-1/4 53 x 22 1/4 x 11 46 x 34 1/4 x 13 3/8 61 x 16-1/8 x 37
39.7 39.7 49.6 70.5 112.5
46.3 47.4 56.2 81.6 132.4
37 x 25 x 16 1/2 37 x 25 x 16 1/2 39 x 17 3/4 x 28 3/4 43 x 36 1/4 x 18 1/8 43 x 36 1/4 x 18 1/8
75 75 108 155 192
85 82 117 166 215
107 108 108 214.5 262.5
123.5 121 158 245.5 305.4
™
Concealed Ducted Heat Pumps
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh.
For more information, visit w ww.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
17