ROOM AIR CONDITIONER SELECTOR GUIDE
COMMERCIAL GRADE RESIDENTIAL GRADE
®
Kühl
Kühl
®
+
Chill
Chill™+
Bold design and
exclusive features.
Description
Room size (sq. ft.) 100-2700 350-2700 100-1500 100-1500
OVERVIEW
Functions
Applications
Programmability to rival
central systems. Trusted
Friedrich durability.
Designer colors.
COOL
COMMERCIAL AND
RESIDENTIAL
All the performance and
durability of Kühl, plus
heating. Choose efcient
heat pump or toasty
electric heat.
Good value. Available
in a large range of cooling capacities.
24-hr. timer.
models with electric
HEAT/COOL COOL HEAT/COOL
COMMERCIAL AND
RESIDENTIAL
RESIDENTIAL AND LIGHT
COMMERCIAL
RESIDENTIAL AND LIGHT
Electronic controls Y Y Y Y
Timer
7-day with up to 4 settings per day*;
24 hr. timer
7-day with up to 4 settings per day*;
24-hr. timer
24 hr. 24-hr.
Remote control LCD LCD LCD LCD
Control with smart phone or computer with FriedrichLink
(accessory required)
Y Y
Auto-restart w/setting retention Y Y Y Y
Auto temp/ fan speed adjustment Y Y
Air ow directions 8 8 4 4
COMFORT & CONVENIENCE
Auto swing louvers All except CP05 Y
Optional color fronts Y Y
Steel inner wall and extra dense insulation Y Y
Vibration isolating design and components
TECHNOLOGY
Superior airflow design Y Y
SOUND REDUCTION
Y Y
Good value. Four
heat. 24-hr. timer.
COMMERCIAL
ENERGY STAR® models Y Y Y Y
Smart Grid capable Y Y
Environmentally friendly R-410A Y Y Y Y
Energy saver switch Y Y Y Y
EARTH FRIENDLY
RoHS compliant Y Y
Washable, antimicrobial air lter Y Y Y Y
Optional carbon lter Y Y
Check lter reminder Y Y
HEALTH
Superior fresh air intake/stale air exhaust Y Y
Stale air exhaust only,
all except CP05
Stale air exhaust only
EntryGard™ anti-intrustion protection Y Y Y Y
Insect barrier Y Y
SAFETY
Slideout chassis Y Y All except CP05 Y
Power cord direction Left or right Left or right Left or right Left or right
Thru-the-wall installation option Y Y All except CP05 Y
INSTALLATION
Window installation hardware Heavy duty
Heavy duty,
available as accessory
Standard Standard
2
Product Selection Tools
COOLING SIZING GUIDE
These tools are only a guide. Due to variations in room design, local climate and occupancy, larger areas may require the use of multiple units to provide the optimal cooling solution. Please consult your local authorized Friedrich distributor or the Friedrich Technical Assistance team for sizing or application assistance.
COOLING SIZING GUIDE The cooling guide to the right is based on normal room insulation, average
number of sun-exposed windows and two-person occupancy. HEATING SIZING INFORMATION
In heating mode, an energy efcient heat pump will generate slightly less
heating Btus than it would in cooling mode. However, in heating mode, heat pumps use approximately 1/3 the energy of resistance heat, making them an
excellent high efciency alternative. Back-up resistance heat ensures heat operation below 40� F outdoor temperatures for year ‘round comfort.
Common Window Types
Traditional wooden windows are typical in many residences built before 1965, but more modern windows are often constructed of aluminum or vinyl.
Many newer energy efcient windows like double-glazed windows actually
sandwich low conductance gas between two panes of glass. While Friedrich air conditioners may be used with this type of window, care should be taken not to break the seal between the two panes of glass during installation.
Depending on the style of window in the application, you may want to consider the cooling solutions in the adjacent chart. Professional installers may be able
to make eld adaptations, including removing all or part of a window to support
alternative types of air conditioning units. Professional installers should also be able to tell you about any local codes that may apply to your installation.
THRU-THE-WALL INSTALLATION Many models may be installed through a wall so long as the unit’s side vents are not blocked or covered in any way. See page 15, In-wall Installation max. depth.
Area to be conditioned in
sq. ft. Cooling Btu
100 - 150 5000
150 - 250 6000
250 - 300 7000
300 - 350 8000
350 - 400 9000
400 - 450 10000
450 - 550 12000
550 - 700 14000
700 - 1000 18000
1000 - 1200 21000
1200 - 1400 23000
1400 - 1600 25000
1600 - 1900 28000
1900 - 2700 36000
Cooling Solutions
WHICH AIR CONDITIONER
IS RIGHT FOR YOU?
Window Type Air Conditioner
Single/double hung Window, portable,
ductless
Slider Window, portable,
ductless
Casement Window, portable,
ductless
Vertical Casement Window, portable,
ductless
Awning Window, portable,
ductless
Hopper Window, portable,
ductless
Picture (non-opening) Thru-the-wall,
ductless
Single/double hung Slider
(Opens up or down) (Opens left to right, or right to left)
Awning Hopper Casement
(Cranks out) (Opens in) (Cranks out)
3
COMMERCIAL GRADE ROOM CONDITIONERS
FRIEDRICH KÜHL SERIES
4
QUALITY CONSTRUCTION
KÜHL
DURABILITY
KÜHL
TECHNOLOGY
KÜHL
The HIGHEST GRADE MATERIALS are used to build a product that will perform reliably season after season.
20 GAUGE STEEL cabinet will withstand years of
hard use.
SOLID SLEEVE TOP* keeps out falling debris,
which can obstruct the fan and prevent it from turning, thus damaging the unit.
VIBRATION AND NOISE ISOLATING TECHNOLOGY
Like two resiliant rings on motor mount, preventing metal-to-metal contact, that causes vibration and noise.
SOLID STEEL BLOWER WHEEL HOUSING
Constructed from solid steel for maximum sound reduction.
SCIENTIFIC REFRIGERATION DESIGN
For quieter performance.
* Feature not on Kühl SQ and EQ models
SUPERIOR COMPONENTS
RIFLED COPPER TUBING with greater surface
area for heat exchange, increases the efciency
of the coils, and improves the overall energy
efciency of the unit.
INSULATED PLENUM prevents outside air
intrusion.
ENTRYGARD
Steel retaining wire secures chassis to the sleeve
to deter ‘kick-in’ intrusion.
FIRM GRIP HANDLES make grasping the chassis
much easier during installation and removal.
ALUMINUM REAR GRILLE
protects the unit from damage and vandalism. No one else offers this feature.
ANTI-INTRUSION PROTECTION
CONTROL
What make’s Friedrich Kühl ultra premium?
Superior components like ROBUST,
COMMERCIAL GRADE FAN MOTORS
that run at a lower temperature than smaller fan motors prevent the unit from overheating and contribute to a longer life. FAN MOTORS ARE ALSO TOTALLY
ENCLOSED for maximum protection and
longer life.
HIGH EFFICIENCY COMPRESSORS
mounted on LARGE, VIBRATION-
ABSORBING GROMMETS create smooth,
quiet power.
Totally enclosed motor
5
tubing
Aluminum nsRied copper
Vibration-isolating grommets
High efciency
compressors
Loading...