Friedrich D25D User Manual

www.sylvane.com 1-800-934-9194
Dehumidifier
D25D, D50D, D70D
Installation and Operation Manual
Models
D25D Volts: 115/60Hz Capacity: 25 Pints Moisture Removal: 25 Pint/Day
D50D
D70D
920-198-10 (3-10)
Capacity: 50 Pints
Capacity: 70 Pints
Moisture Removal: 50 Pint/Day
Moisture Removal: 70 Pint/Day
www.sylvane.com 1-800-934-9194
920-198-10
Congratulations!
Thank you for your decision to purchase the Friedrich Dehumidier. Please read thoroughly of this Installation and Operation Manual.
THANK YOU, on behalf of our entire company,
for making such a wise purchase.
Table of Contents
DESCRIPTION OF COMPONENTS ....................................................................................................................................................................................... 3
FUNCTION EXPLANATION .................................................................................................................................................................................................... 3
INSTALLATION INSTRUCTIONS............................................................................................................................................................................................ 4
OPERATION INSTRUCTIONS ................................................................................................................................................................................................ 4
OPERATING DO'S AND DON'TS ...........................................................................................................................................................................................6
CONTINUOUS DRAINAGE ..................................................................................................................................................................................................... 8
MAINTENANCE ..................................................................................................................................................................................................................... 10
IN CASE OF EMERGENCY ................................................................................................................................................................................................... 11
2
www.sylvane.com 1-800-934-9194
DESCRIPTION OF COMPONENTS
Figure 1
AIR FILTER
MOIST AIR
INTAKE
CONTROL PANEL
920-198-10
DEHUMIDIFIED
DRY AIR VENT
HANDLE
DRAIN BUCKET
FUNCTION EXPLANATION
Figure 2
BUCKET FULL LAMP
LAMP LIGHTS WHEN DRAIN BUCKET IS FULL AND NEEDS TO BE EMPTIED.
FAN SPEED
HIGH/LOW
POWER
ON/OFF
DEFROST LAMP
LAMP LIGHTS WHEN UNIT IS DEFROSTING (SEE PAGE 5).
TIMERS
WHEN THE UNIT IS ON PRESS THE TIMER BUTTON TO DISPLAY THE POWER OFF TIMER. SELECT FROM 1-24 HOURS OF RUNNING TIME UNTIL THE UNIT SHUTS OFF AUTOMATICALLY. WHEN THE UNIT IS OFF PRESS THE TIMER BUTTON TO DISPLAY THE POWER ON TIMER. SELECT FROM 1-24 HOURS UNTIL THE UNIT WILL TURN ON AUTOMATICALLY.
ROLL CASTERS
DRAIN PUMP OUTLET
(ONLY ON 50 AND 70 PINT MODELS)
CURRENT TEMP / TIMER SET DISPLAY
WHEN THE UNIT IS RUNNING THE CURRENT TEMP IS DISPLAYED. WHEN THE TIMER BUTTON IS PRESSED THIS WINDOW DISPLAYS THE TIMER SETTING THEN REVERTS BACK TO THE TEMPERATURE AFTER 10 SECONDS.
CURRENT HUMIDITY DISPLAY
DISPLAYS THE CURRENT RELATIVE HUMIDITY (RH) IN THE ROOM. WHEN THE OR IS PRESSED THE HUMIDITY SETTING IS DISPLAYED.
SET HUMIDITY
ADJUST THE HUMIDITY % FROM 30% TO 90% RH BY PRESSING THE OR BUTTONS. HUMIDITY IS ADJUSTED IN 5% INCREMENTS.
CONTINUOUS
DRAINAGE OUTLET
°C/°F SELECTOR
PRESS THE °C/°F SWITCH BUTTONS IT WILL SWITCH BETWEEN °C AND °F.
FRD001
FRD002
3
www.sylvane.com 1-800-934-9194
920-198-10
INSTALLATION INSTRUCTIONS
Follow the steps below for unpacking and set up your unit.
STEP 1. Remove unit from carton and inspect.
STEP 2. Remove accessories from drain bucket.
STEP 3. Install Roll Casters (D25D models only) per installation
instructions below.
STEP 4. Set up unit in position with adequate clearance. Installation
of unit is complete.
Roll Caster Installation (D25D Models only)
STEP 1. Locate Roll Casters removed during STEP 2 above.
STEP 2. Lay unit on its side for ease of installation.
STEP 3. Insert Roll Casters in slots as shown (See Figure 3) until they
click into place.
Figure 3
ROLL CASTER
OPERATION INSTRUCTIONS
WARNING
Electrical Hazards
Do not fold power cord as shown at left.
Make sure the plug is placed fully and firmly into the receptacle.
Do not use multiple sockets as shown at left.
FRD031
STEP 4. Set the unit upright. Roll Caster installation is complete.
STEP 5. Allow unit to sit upright 1 hour before operating.
Allow 8 inches of space on all sides of the unit.
Figure 4
8’’
8’’
8’’
4
8’’
FRD032
Make sure the plug is clean.
After turning the unit off please take plug out of the receptacle.
Do not have wet hands when connecting the power plug.
Do not pull the power cord to avoid a broken cord, which can lead to danger.